PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Similar documents
PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 16 ATEX E088 X, IECEx BVS X. Operating Instructions

Type Quickstart

Type ME43. Quickstart

Type Quickstart (from device Version 2)

SolConeX extra-low voltage flange socket

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

B63/ NS MS. EtherNet/IP LINK

Electronic Temperature Controller. Instruction Manual Version

Metal Position Switch

Installation manual plugs and connectors with screw connection (16/32 A)

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Technical Manual Room temperature controller

MDM 011-Z1 Regen Resistor

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Type Operating Instructions - Software. Bedienungsanleitung - Software Manuel d utilisation - Logiciel

Installation Instruction. HART Add-On Module

Type MS04. Redox potential sensor cube. Operating Instructions

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V


SolConeX Wall-Mounted Socket, 16 A

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

GRP Flameproof Visual Signal Xenon or Steady LED

Operating Instructions

Operating Instructions

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

NXT4 Three phase meter for commercial, industrial and advanced residential applications

Product manual plug, sockets and coupler 16 A.- Z0251

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

TEMPERIX S Clamp. FAFNIR GmbH Schnackenburgallee 149 c Hamburg Germany

Mounting and Operating Instructions EB EN. Electric Actuators Type 5824 without fail-safe action Type 5825 with fail-safe action

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Type Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions

HST -S1 Switching element (Translation of Original Manual)

Lucid arena pro LED luminaire

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

MANUAL Surge Protectors

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

MINI MCR-SL-CVS NC

PHOENIX CONTACT - 05/2007

Quick Start Guide MHM CC-PBF-EN, Rev 1 April Emerson A0701PBU. Emerson 701P SmartPower Module - Blue

Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

Operating instructions. Switching amplifier DN0210 DN / / 2015

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

ETD-BL-1T-OFF-CC- 10S

Operating Instructions

Expansion module EM-BAC-MOD-01. Installation manual

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SUBCON-PLUS-PROFIB...

Intrinsically safe batch controller Batching Master 110i

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Installation Instructions

MC 11 EB-2 Power supply cabinet with external bus, AC version

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Operating instructions IO-Link master CabinetLine AL19xx

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

CMC III Temperature/Humidity Sensor

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

Accessories for stand-alone gird inverter SMART LOAD 6000

MANUAL. Document Version 1.0/March SLIMdrive-500

MANUAL LML-P, LML-S, LML-Ex

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

IECEx Certificate of Conformity

PHOENIX CONTACT - 01/2008

Operating instructions

M E M O R A N D U M I.S.

Operating instructions. Speed monitor D / / 2014

ISG Isolated DIN Rail Mount Signal Conditioner Issue: Revision A Technical User Manual

Technical Manual Sensor / Switch actuator 1/1gang; 2/1gang; 2/2gang

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Installation and safety instructions for devices for conveying air/gas mixtures

CMC III Universal Sensor

MINI MCR-SL-MUX-V8-FLK 16

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners. User manual

Transcription:

, Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple: Type 1058 Operating Instructions Bedienungsanleitung Manuel d utilisation

We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert Werke GmbH & Co. KG, 2003-2018 Operating Instructions 1805/14_EU-EN_00803973 / Original DE

Table of Contents: 1 OPERATING INSTRUCTIONS...4 1.1 Symbols... 4 2 INTENDED USE...5 2.1 Approval... 5 3 GENERAL SAFETY INSTRUCTIONS...6 4 GENERAL INFORMATION...7 4.1 Contact addresses... 7 4.2 Warranty... 7 4.3 Information on the Internet... 7 4.4 Conformity and standards... 7 5 APPLICATION CONDITIONS FOR THE UNITS...8 6 TECHNICAL DATA...8 6.1 Identification (example)...8 7 INSTALLATION AND START-UP...9 7.1 Safety Instructions... 9 7.2 Installation... 9 7.3 Start-Up...10 8 MAINTENANCE AND REPAIRS...10 8.1 Troubleshooting...10 9 ACCESSORIES...11 10 TRANSPORT, STORAGE, DISPOSAL...11 3

Operating instructions 1 OPERATING INSTRUCTIONS The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. WARNING! The operating instructions contain important safety information! Failure to observe these instructions may result in hazardous situations. The operating instructions must be read and understood. Carefully read the operating instructions before using the device. In particular observe the chapter entitled 2 Intended Use, and 3 General Safety Instructions as well as the chapter entitled 5 Application Conditions for the units. 1.1 Symbols To identify important information, the following symbols are used in the operating instructions: DANGER! WARNING! Warns of a potentially dangerous situation! Failure to observe the warning may result in serious injuries or death. CAUTION! Warns of a possible danger! Failure to observe the warning may result in moderately serious or minor injuries. NOTE! Warns of damage to property! designates additional significant information, tips and recommendations. refers to information in these operating instructions or in other documentation. designates instructions for risk prevention. designates a procedure which you must carry out. Warns of an immediate danger! Failure to observe the warning may result in a fatal or serious injury. 4

Intended Use 2 INTENDED USE WARNING! The device may only be used for the applications indicated in the chapter Operating conditions for the devices, and only in connection with third-party devices or components recommended or approved by Bürkert. Observe the instructions in this operating manual, as well as the conditions of use and permissible data specified in the chapter Operating conditions for the devices. The proper and safe function of the system depends on proper transport, storage and installation, and on careful operation and maintenance. The type 1058 equipment protection fuse is used to protect small electrical consumers, e.g. electromagnets for valve control in areas subject to explosion for application in explosion group IIC, category 2 (see data on the approval plate). Any other utilisation, or a utilisation going beyond this use will be regarded as improper. Bürkert will accept no liability for any damage resulting from such use. The user must bear all the risk alone. 2.1 Approval The approval is only valid if the modules and components authorized by Bürkert are used as described in these operating instructions. The equipment protection fuse Type 1058 may be used only in combination with the additional components released by Bürkert, otherwise the approval will be voided! If any unauthorized changes are made to the device, modules or components, the approval will also be voided. The EC type-examination certificate PTB ATEX 2064 U respectively was issued by the PTB (Physikalisch Technische Bundesanstalt) Bundesallee 100 38116 Braunschweig Production is audited by: CE 0102 PTB (Physikalisch Technische Bundesanstalt) Bundesallee 100 38116 Braunschweig 5

General Safety Instructions 3 GENERAL SAFETY INSTRUCTIONS These safety instructions do not make allowance for any contingencies and events which may arise during the installation, operation and maintenance of the devices. local safety regulations, whereby the operator is responsible for their compliance, by the installation personnel too. DANGER! Danger of explosion! The device is a sealed system. If used in the EX area, there is a danger of explosion if the system is opened during operation! The system must not be disassembled during operation. Electrical power supply in the system! Acute risk of injury from hazardous structure-borne voltage! Risk of damage to the device due to short circuit! Work on the electrical system may only be carried out by qualified electricians. Before starting work, switch off the power supply and secure to prevent it being switched on again! Observe the applicable accident prevention and safety regulations for electrical devices! DANGER! Danger high pressure! There is a serious risk of injury when reaching into the system. Only skilled and instructed personnel may work on the system with suitable tools. Before disconnecting lines and valves, switch off the pressure and bleed the lines. During installation note the direction of flow. Observe applicable accident prevention and safety regulations for pressurised devices! After an interruption in the power supply or fluid supply, ensure that the process is restarted in a defined or controlled manner! General hazards! Unintentional activation or unauthorised impairment of the system may cause general hazardous situations through to physical injury. Take appropriate measures to prevent the system from being accidentally actuated! Do not make any unauthorised changes to the system. Non-observance of the generally acknowledged safety rules may cause general hazardous situations through to physical injury. Observe the generally acknowledged safety rules for resource planning and operation of the device. 6

General Safety Instructions Operate the device in perfect working order only and in accordance with the operating instructions. 4 GENERAL INFORMATION 4.1 Contact addresses Germany Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10 91 111 Fax + 49 (0) 7940-10 91 448 E-mail: info@de.buerkert.com 4.3 Information on the Internet The operating instructions and data sheets for Bürkert products can be found on the Internet at: www.burkert.com 4.4 Conformity and standards The applied standards, which verify conformity with the EC Directives, can be found on the EC-Type Examination Certificate. The following standards were used to evaluate the equipment protection fuse of Type 1058: EN 60079-0:2012/A11:2013 EN 60079-18:2015 International Contact addresses can be found on the final pages of the printed operating instructions. And also on the Internet at: www.burkert.com 4.2 Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions. 7

Application Conditions for the units 5 APPLICATION CONDITIONS FOR THE UNITS GEFAHR! 6.1 Identification (example) Danger of explosion! The equipment protection fuse must be installed in a housing. The housing must comply with a suitable ignition protection type according to EN 60079-0. When installing the fuse as an Ex component in a complete Ex device, the following must be checked and assessed when the fuse has been installed: Surface temperature of the fuse, Clearance and creepage distances from the fuse to surrounding conductive parts. The equipment protection fuse must be attached and electrically connected to the clamping lugs using cheese-head screws M4 and secured with circlips to prevent them from working loose. Fig. 1: 74653 Ingelfingen 1058-*,***A PE65 ******** 250V F PTB 01 ATEX 2064 U II 2G Ex mb IIC Gb Ex mb IIC Gb 0102 1 2 3 4 5 Example of a type label, equipment protection fuse Type 1058 6 6 TECHNICAL DATA Explosion protection Ex mb II C GB Rated voltage 250 V Rated current 0.032... 4A Breaking capacity 1500 A, 250 V Ambient temperature 40...+70 C Melting behaviour F to IEC 60127-2/1 Pos. Description 1 Type identification with nominal current and Ex code 2 Bürkert identification number, nominal voltage and melting behavior 3 ATEX, certificate author and certificate number 4 ATEX, identification of the Ex protection 5 IECEx, certificate author and certificate number 6 IECEx, identification of the Ex protection 8

Installation and Start-up 7 INSTALLATION AND START-UP 7.1 Safety Instructions DANGER! Danger of explosion! The device is a sealed system. If used in the EX area, there is a danger of explosion if the system is opened during operation! The system must not be disassembled during operation. Danger of explosion caused by electrostatic charge! If there is a sudden discharge from electrostatically charged devices or persons, there is a danger of explosion in the EX area. Take appropriate measures to prevent electrostatic charges in the EX area. Clean the device surface by gently wiping it with a damp or antistatic cloth Risk of electric shock! Acute risk of injury from hazardous structure-borne voltage! Risk of damage to the device due to short circuit! Work on the electrical system may only be carried out by qualified electricians. Before starting work, switch off the power supply and secure to prevent it being switched on again! Observe the applicable accident prevention and safety regulations for electrical devices! Only fit the equipment protection fuse when undamaged and clean! To be noted when using the type 1058 equipment protection fuse the characteristic values on the equipment protection fuse! 7.2 Installation cheese-head screws M4 Fix the equipment protection fuse to the spring washers clamping straps with two cheese-head screws (M4). This also provides electrical connection. The spring washers prevent the screws loosening. clamping straps Observe the stipulated tightening torque of the connection terminals to which the equipment protection fuse is attached. 9

Maintenance and Repairs 7.3 Start-Up WARNING! Danger due to improper operation! Improper operation may result in injuries as well as damage to the device and the area around it. Before start-up, ensure that the operating personnel are familiar with and completely understand the contents of the operating instructions. In particular observe the safety instructions and intended use. The device/the equipment may be started by adequately trained personnel only. Before start-up, ensure that the equipment protection fuse has been fitted according to regulations, the equipment protection fuse is not damaged, the connecting area is clean, the connection has been properly made, all screws are fully tightened. 8 MAINTENANCE AND REPAIRS DANGER! Danger - improper repairs! Hazards due to improper service, repair and maintenance work. Have the device repaired by the manufacturer only! No repairs or modifications must be made to the type 1058 equipment protection fuses. Defective equipment protection fuses must be replaced. Observe the valid national conditions in the country where used. 8.1 Troubleshooting In the event of malfunctions, make sure that the device has been installed according to the instructions, the connection has been made properly, the device is not damaged, the pipelines are free. 10

Transport, Storage, Disposal 9 ACCESSORIES Available versions of the equipment protection fuse Type 1058: Version Order No. 0,050A 300254 0,063A 300255 0,080A 300256 0,100A 300257 0,125A 300258 0,160A 300259 0,200A 300260 0,250A 300261 0,315A 300262 0,400A 300263 0,500A 300264 1,000A 300265 1,250A 300266 1,600A 300267 10 TRANSPORT, STORAGE, DISPOSAL NOTE! Transport damages! Inadequately protected equipment may be damaged during transport. During transportation protect the device against wet and dirt in shock-resistant packaging. Avoid exceeding or dropping below the allowable storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature -40 +55 C. Damage to the environment caused by device components contaminated with media. Ensure the device and packaging are disposed of in an environmentally sound manner. Observe applicable regulations relating to refuse disposal and the environment. 11

www.burkert.com