PowerFlex 700S Drives with Phase II Control (4.002)

Similar documents
DriveTools SP v4.03 Software Patch

Drive Software Wizards v1.3

PowerFlex 700H Drive Firmware (Revision )

Drive Software Wizards v2.2

Drive Software Wizards v2.3

PowerFlex 7-Class Human Interface Module Series A Firmware v3.010

DriveTools SP v5.03 Software Patch

1203-SSS Smart Self-powered Serial Converter Firmware v3.006

1203-SSS Smart Self-powered Serial Converter Firmware v3.007

20-WIM-Nx DPI Wireless Interface Module Firmware v1.003

20-COMM-M Modbus/TCP Adapter Firmware v2.001

1203-EN1 EtherNet/IP-to-SCANport Module Firmware v1.005

PowerFlex 20-HIM-A6 and 20-HIM-C6S HIM Firmware Revision 1.006

20-COMM-B BACnet MS/TP Adapter Firmware v1.002

PowerFlex 753 Drives (revision 8.002)

20-COMM-P Profibus Adapter Firmware v1.006

20-COMM-E EtherNet/IP Adapter Firmware v4.001

PowerFlex 753 Drives (revision 9.002)

PowerFlex 753 Drives (revision 1.009)

PowerFlex 753 Drives (revision )

PowerFlex 753 Drives (revision )

20-COMM-H RS485 HVAC Adapter Firmware Revision 2.010

PowerFlex 753 Drives (revision 1.007)

Ferrite Core for Internal DPI Cables on PowerFlex 700S Frame 3 and 4 Drives

20-COMM-H RS485 HVAC Adapter Firmware Revision 2.009

PowerFlex 753 Drives (revision 1.010)

22-COMM-B BACnet MS/TP Adapter Firmware v1.003

PowerFlex 755 Drives (revision 4.002)

PowerFlex 753 Drives (revision 1.011)

PowerFlex 753 Drives (revision 6.003)

PowerFlex 700 Drive w/vector Control Option (Revision 9.001)

PowerFlex 755 Drives (revision 2.009)

PowerFlex 755 Drives (revision )

PowerFlex 400 Drive Firmware Version 7.01

PowerFlex 700 AC Drive with Vector Control Option, Firmware Revision

PowerFlex 700H Drive Firmware Revision

PowerFlex 70 Drive with Enhanced Control Option Firmware 4.001

20-COMM-E EtherNet/IP Adapter Firmware Revision 4.002

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

Drive Software Wizards v3.2

PowerFlex 755 Drives (revision 3.005)

PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

DriveTools SP v5.05 Software Patch

PowerFlex 400 AC Drive Guide Specification

Drive Software Wizards Version 3.10

Regulator Board Installation Instructions for WebPak 3000 Version 1.x Drives

PowerFlex 700S and 700H Frame 11 Replacement Power Structures

DriveTools SP Version 5.06 Software Patch

GV3000/SE AC Drive Quick Reference Version 6.06

XM Firmware Revision 3

XM Firmware Revision 4

ControlNet-to-DeviceNet Linking Device

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

Allen-Bradley. PowerFlex DSI Communication Adapters. DeviceNet (22-COMM-D) EtherNet/IP (22-COMM-E) PROFIBUS (22-COMM-P) RS-232 DF1 Module (22-SCM-232)

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

PowerFlex 700 Power Jumpers

ControlLogix Configurable Flowmeter Module Firmware Revision 2.4

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

PowerFlex 700S and 700H Frame 13 Replacement Power Structures

ControlNet Comm Glass Fiber Adapter Kit

PowerFlex 755. Adjustable Frequency AC Drive. Drive Description. Contents. Conformity to Standards

PRODUCT PROFILE. PowerFlex 700 AC Drive. Powerful Performance. Flexible Control. Excellent Performance

For Classroom Use Only! Flying Start PowerFlex 755 AC Drives

SynchLink Board for PowerFlex 700S Drives with Phase II Control

ControlLogix EtherNet/IP Bridge Module

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

Bus Regulation. PowerFlex 755 AC Drives. For Classroom Use Only!

DriveLogix 5730 Controller (13.20)

Allen-Bradley Bulletin 1336/1336VT Firmware Feature/Compatibility

PowerFlex DC Stand-Alone Regulator (SAR) Power Interface Circuit Board

Reliance GV3000 Drive Registers

Release Notes. GML Commander Software Release v4.03. Enhancements. GML Commander v4.03 includes the following enhancements and corrections:

PowerFlex 700H Sample Specification

PowerFlex 755 AC Drive

PowerFlex DC Stand-Alone Regulator (SAR) Switching Power Supply Circuit Board

PowerFlex 700S / 700H Adjustable Frequency AC Drives

PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board

PowerFlex DC Stand-Alone Regulator (SAR) In-Rush Limiting Resistor

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

PowerFlex 40 Sample Specification

Adjustable Frequency AC Drive

ControlLogix Controllers Revision 14

EtherNet/IP Adapter. 20-COMM-E FRN 2.xxx. User Manual. AB Drives

PowerFlex 700H Adjustable Frequency AC Drive. Programming Manual V1.xxx 5.002

S-curve Creation with an Ultra3000 Indexer

PowerFlex 700S Power Jumpers Frames 1 6

Basic Drive Programming PowerFlex 755 Basic Start Up

1336 PLUS II Quick Start Guide

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

ControlNet Adapters. User Manual. 20-COMM-C (coax) 20-COMM-Q (fiber) FRN 1.xxx

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

DriveGuard. Safe-Off Option for PowerFlex 700S Phase II AC Drives. User Manual.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Drive Application Software Application Set

Time-based Position Capture Algorithm

Enhanced, Protected, Ethernet, and ControlNet PLC-5 Firmware

InView Firmware Update

Logix5000 Control Systems: Connect a PanelView Plus Terminal over an EtherNet/IP Network

Unico 2400 Drive Faults Descriptions and Causes Dec. 2016

Transcription:

Release Notes PowerFlex 700S Drives with Phase II Control (4.002) These release notes correspond to major revision (4), minor revision (2) of firmware for PowerFlex 700S drives with Phase II control. Introduction The following information is included in this document: For information about: See page: Determining Firmware Revision Level 1 Firmware Upgrades 2 Enhancements 2 Corrected Anomalies 5 Known Anomalies 6 Restrictions 8 Rockwell Automation Support 11 Installation Assistance 11 New Product Satisfaction Return 11 Determining Firmware Revision Level To determine the firmware version for a PowerFlex 700S drive, view parameters 314 [VPL Firmware Rev] and 315 [VPL Build Number]. The firmware version is the combination of the data in these parameters. Example: Firmware Version 4.002.01 Firmware revision from parameter 314 [VPL Firmware Rev] Firmware build number from parameter 315 [VPL Build Number]

2 PowerFlex 700S Drives with Phase II Control (4.002) Firmware Upgrades This section describes procedures for upgrading your firmware: When updating firmware version 1.xx to version 2.xx or higher, boot code v1.06 must be flashed into the drive. Use the following procedure to upgrade the boot code along with the application code: Upgrading from version 1.12 (or before 2.xx release) 1. Flash 700S2bt01_06.bin using 1203-SSS Series B and HyperTerminal. 2. Cycle the power (automatically). 3. HIM displays "No System Application..." error message - ignore this error. 4. Flash 700S2ap04_002.bin using 1203-SSS Series B and HyperTerminal. 5. Cycle the power (automatically). 6. HIM displays as normal. If upgrading firmware version after version 2.xx (i.e., v2.03), upgrading the application firmware only is required. Enhancements This section describes the enhancements included in this revision: Added PCCC N-File Function to Software Control Bar This function has been added to allow drive control via the Control Bar from DriveExecutive and the ability to use the available DriveTools SP Wizards when controlling a PowerFlex 700S Phase II drive with DriveLogix using all DriveLogix communications options. Added Full DPI Configuration Support This new configuration allows a drive to support all Automatic Device Configuration (previously, Automatic Device Replacement) requirements. Added Support for Frame 14 Drive This firmware revision supports the new frame 14 rating; 690 volts AC input, 1500 amps.

PowerFlex 700S Drives with Phase II Control (4.002) 3 Added New RideThru Alarm (F92) This feature provides a RideThru (F92) alarm when the drive is in a Ride Through condition and parameter 406 [Power Loss Mode] is set to 0 Coast or 5 Flux Only. When in a RideThru alarm state the HIM displays the alarm icon (bell), the alarm queue displays F92 and bit 27 Reserved of parameter 328 [Alarm Status 3] is set. Bits 8, 9 and 21 of Parameter 513 [V/Hz Mode Config] now Run Read Only The firmware has been updated to inhibit changing bits 8 BusGain Comp, 9 ReflWaveComp and 21 VltMinorLpEn while the drive is in run mode. Prevent Automatic Tach Switch in Permanent Magnet Mode With this firmware revision, bit16 Auto Tach Sw of parameter 153 [Control Options] cannot be set when the drive is in the Permanent Magnet mode (Par 485 [Motor Ctrl Mode] = 2 PMag Motor ), thus, not allowing a switch to another feedback device (i.e. another encoder or sensorless feedback). Improved the Fast Flux Up Function and Flux Current (Id) Reference This enhancement improved the fast flux up performance and the transition from a fast flux up reference to rated flux reference. Motor Control Test Point Parameters now Updated in Task 1 With this enhancement the Motor Control test point parameters (466, 467, 468, 473, 474, 475 and 476) are now updated in Task 1 (the fastest VPL interrupt routine), providing more meaningful data. Enhanced Slip Tuning for High Inertia Motors The Slip Tune function was enhanced to improve slip tuning for high inertia motors. Changed the Turn-Off Point for the Analog Output Scale Parameters The turn-off point (minimum value) of the Analog Output Scale parameters (835 and 842) has been changed from +/-0.001 to +/-0.0001. This change allows you to monitor a smaller analog output value.

4 PowerFlex 700S Drives with Phase II Control (4.002) Enhanced Processor Utilization The Processor utilization was improved in order to provide more time for FOC/Encoder modes for frames 1-6. Note: This change had previously been implemented for the high horse power drives (frame 9 and up). Minimum Value of Parameter 415 [BusReg/Brake Ref] Changed to 100.0 for 600V Drives The minimum value of parameter 415 [BusReg/Brake Ref] has been changed from 110.5 to 100.0 when 600V is selected on a 600V/690V AC input, frame 5 and above drive. This change provides the ability to adjust the dynamic brake turn on voltage level in order to prevent bus over voltages for shared bus applications when 690V, frames 5 and above drives, are used in combination with frame 4 and lower drives. Miscellaneous Database Changes The following database changes were made for this firmware revision: The maximum value of parameter 2 [Motor NP FLA] has been changed from 2000 to 3000 amps to accommodate frame 14 drives. Note: This value is calculated by the drive. The maximum value of parameter 7 [Motor Poles] has been changed from 60 to 128. This change allows the drive to use higher pole count motors. Parameters 48 [Spd Ref Bypass2] and 916 [SL Clr Events] are now recallable. This change now saves the link for these parameters. Added the following Fault Test Point selections to parameter 329 [Fault TP Sel]: 24 ElpsSec.mSec, Elapsed time in seconds and milliseconds since the last power up 25 ElpsMin.Sec, Elapsed time in minutes and seconds since the last power up 26 ElpsHour.Min, Elapsed time in hours and minutes since the last power up 27 ElpsDay.Hour, Elapsed time in days and hours since the last power up The default value for parameter 370 [HiHp InPhsLs Cfg] was changed from 3 Flt RampStop to 2 FltCoastStop. The maximum value of parameter 400 [Rated Amps] has been changed from 2500 to 3000 amps to accommodate frame 14 drives.

PowerFlex 700S Drives with Phase II Control (4.002) 5 Added Motor Control test point selection 163 Flux Up Time to parameters 466 [MC TP1 Select] and 473 [MC TP2 Select]. The Motor Control test point allows you to see the flux up time for both Fast Flux Up and standard flux conditions. Corrected Anomalies This section describes the anomalies corrected in this revision: HiHp Drv OvrLoad Fault (F71) Occurs when Saving to EEPROM while Drive is Running The high horse power drives would experience a HiHP Drv OvrLoad (F71) fault when manually invoking the EEPROM function while the drive is running. This firmware revision corrects this anomaly. Improved Thermal Regulator Behavior for PowerFlex 700L Drives The behavior of the thermal regulator has been improved to support PowerFlex 700L drives. Incorrect Torque Reference Calculation in Permanent Magnet Mode The torque reference calculation for Permanent Magnet Motor control mode has been corrected in this firmware revision to provide a more accurate torque current. Inv Otemp Trip (F15) Occurs During 600/690V AC Frame 12 Drive Power Up This firmware revision provides a different power up time for the 600/690V AC frame 12 drive to correct an erroneous Inv Otemp Trip fault (F15). Motion Homing Position Error in Rotary Mode and Registration Problem This firmware corrects an anomaly that caused the drive to look for the Armed bit when it should be looking for the Found bit (Lgx73742). Over Junction Temperature at 2 khz Carrier Frequency with PowerFlex 700L Drive The junction temperature calculation for the PF700L did not correctly compensate for a change in carrier frequency from 4 KHz to 2 KHz. This anomaly has been corrected with this firmware revision.

6 PowerFlex 700S Drives with Phase II Control (4.002) Ramp to Stop, Current Limit Stop and Coast to Stop Fault Response Not Functioning This anomaly prevented faults that could be configured as 2 FltCoastStop, 3 Flt RampStop or 4 FltCurLimStp from responding with the corresponding action (i.e., coast to stop, ramp to stop or current limit stop) when the corresponding fault occurred. This anomaly has been corrected in this firmware revision. The default value for parameter 370 was changed from 3 Flt RampStop to 2 FltCoastStop in order to maintain the functionality that was present in earlier firmware releases. Skip Band Anomalies with Zero and Negative Set Points in V/Hz Mode This anomaly caused the drive to ignore the minimum value when a zero value was set between the maximum and minimum skip frequency values when the drive is running in V/Hz mode. The firmware has been corrected to recognize a zero value set between the maximum and minimum skip frequency values. Save HIM Password into EEPROM after Power Down The anomaly where the HIM password was deleted when power was cycled to the drive has been corrected in this firmware version. When utilized, the HIM password will now be saved into EEPROM when the drive is powered down. Known Anomalies This firmware revision contains the following known anomalies: DriveTools SP Alarm Message when Connecting to PowerFlex 700S Phase II Drive with DriveLogix The following alarm message displays in DriveTools SP v4.002 and earlier when connecting to a PowerFlex 700S Phase II drive with DriveLogix via the Ethernet: "The peripheral device port number (0) is invalid. Valid port number range from 1 to 7." This anomaly can be prevented by completing the following: 1. From the Drive menu, select Create Database. 2. When the database has been created, shut down DriveTools SP. 3. Restart DriveTools SP and reconnect to the drive.

PowerFlex 700S Drives with Phase II Control (4.002) 7 Instantaneous Overcurrent Fault (F27) May Occur when Saving to EEPROM on High Horsepower Drives An instantaneous over current fault ( Inst Overcurrent - F27) may occur when saving to EEPROM from the HIM or DriveExecutive while the drive is running on high horsepower drives (frames 9-14). Note: The drive automatically saves all parameter values to EEPROM. MC Firmware Fault (F30) Occurs when Downloading Parameters from HIM after Flash Upgrade to Firmware v3.001 and Higher At drive start up, an MC Firmware (F30) fault will occur for drive frame sizes 9-13 if the following conditions are met: You have flash upgraded to firmware v3.001 or higher, You have downloaded parameters to the drive from an earlier firmware version via the HIM, and Parameter 551 [CurrFdbk AdjTime] is set to a value less than 5 In this case, parameter 551 must be set to the correct value. The correct values are: Frame 9, set P551 to 5 Frame 10, set P551 to 33 Frame 11, set P551 to 34 Frame 12, set P551 to 33 Frame 13, set P551 to 40 Frames 1-6, P551 should be set to 0 With firmware version 3.001 or higher, the drive will automatically set the correct value for the drive. This is completed at power up, provided the value was not changed manually. Parameter 414 [Brake/Bus Cnfg] Incorrectly Set after Start Up Wizard Completes When the PowerFlex 700S Phase II Start Up Wizard is run, the drive correctly sets bit 2 Bus Ref High and 3 Bus Reg En of parameter 414 [Brake/Bus Cnfg], but does not set this parameter back to the previous settings (if different) when the wizard is complete. Parameter 554 [LED Status] Not Functioning Properly Parameter 554 [LED Status], bit 15 DL ComActive, does not work.

8 PowerFlex 700S Drives with Phase II Control (4.002) SynchLink Does Not Reset Properly when SL Reset Bit is Set Setting bit 3 SL Reset of parameter 904 [SL Node Cnfg] in PowerFlex 700S Phase II drives does not appear to reset SynchLink properly for DriveLogix Motion control. A power cycle is required to reset SynchLink so that the CST master is set and DriveLogix Motion control works or to reset the Timekeeper. Trend Functions May Cause Drive to Stop Running When using the trend functions, a PowerFlex 700S drive may stop running. The power to the drive must be cycled in order to correct this condition. If the DriveLogix option is present the 5730 controller may lose its program. Restrictions The following restrictions apply to this revision of firmware: Clearing the Find Home Bit in Parameter 741 [Position Status] If bit 24 Find Home in parameter 740 [Position Control] is set, bit 15 Homed in parameter 741 [Position Status] remains set until a start command is issued. Current Draw Down with Multi-Motor Drive Operation When using a PowerFlex 700S drive to run multiple motors, the drive must be sized in order to provide the total current required to run the connected motors plus the current required to line start any disconnected motors. If the drive s total current rating is not capable of providing the total current described above, the motor speed may slow, possibly to zero, and re-accelerate the motors back to the set speed when line starting a disconnected motor. DC Bus Overvoltage Fault (Fault 24) for High Horsepower Drives A DC Bus overvoltage fault may occur for high horsepower drives when executing a flying start within 2 seconds of a commanded stop with no or light loads. Homing to a Switch and Then to a Marker Not Functional with DriveLogix When using the Homing function with a PowerFlex 700S Phase II drive with DriveLogix, you can either Home to a Switch or Home to a Marker. However, you cannot Home to a Switch and a Marker in the same command.

PowerFlex 700S Drives with Phase II Control (4.002) 9 Motion Registration Input Limited to Digital Input 1 or Registration Input 0 The Registration input to the drive is limited to Digital Input 1 and Registration Input 0. Therefore, the RSLogix MAR (Motion Arm Registration) instruction will not function properly if Registration Input 1 is used. Operating Mode Configuration Parameters Should Not be Changed The following parameters should not be changed by a user: 510 [FVC Mode Config] 511 [FVC2 Mode Config] 512 [PMag Mode Config] 513 [V/Hz Mode Config] Position Control Bits Not Available for Controller The following bits were added to parameters 740 [Position Control] and 741 [Position Status] as part of the Position Control Static Assembly for firmware version 3.01. [Position Control] bit 24 "Find Home" bit 25 "Pos Redefine" bit 26 "Home Dir" bit 27 "Return Home" bit 28 "Home Switch" bit 29 "Home Marker" [Position Status] bit 13 "Home Required" bit 14 "Homing" bit 15 "Homed" However, these bits were not added to the Controller side of the Static Assembly. Therefore, the controller cannot connect to these bits when using the Position Control Communication Format via the static assembly. If it is necessary to have a controller connect to these bits, the User Defined or Custom User Defined Communication format or explicit messaging must be used.

10 PowerFlex 700S Drives with Phase II Control (4.002) Speed Limited Adjustable Torque (SLAT) Bits Not Available for Controller Bits 7 "SLAT Minimum" and 8 "SLAT Maximum" were added to parameter 110 [Speed/TorqueMode] as part of the Speed Control Static Assembly for firmware version 3.01. However, these bits were not added to the Controller side of the Static Assembly. Therefore, the controller cannot connect to bits 7 and 8 when using the Speed Control Communication Format. If it is necessary to have a controller connect to these bits, the User Defined or Custom User Defined Communication format or explicit messaging must be used.

PowerFlex 700S Drives with Phase II Control (4.002) 11 Rockwell Automation Support Rockwell Automation provides technical information on the web to assist you in using our products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com. Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation, please review the information that's contained in this document. You can also contact a special Customer Support number for initial help in getting your module up and running: United States 1.440.646.3223 Monday Friday, 8am 5pm EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues. New Product Satisfaction Return Rockwell tests all of our products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned: United States Outside United States Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process. Please contact your local Rockwell Automation representative for return procedure.

Notes: U.S. Allen-Bradley Drives Technical Support - Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: support@drives.ra.rockwell.com, Online: www.ab.com/support/abdrives www.rockwellautomation.com Power, Control and Information Solutions Headquarters Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 Publication 20D-RN036A-EN-P December 2007 Copyright 2007 Rockwell Automation, Inc. All rights reserved. Printed in USA.