S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

Similar documents
First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Siemens Drives & PLCs

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Readme SiVArc V14 SP1 Update 6

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

PD PA AP How To Configure Maxum II TimeServer Access

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started.

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Optional package printer driver V1.4

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

ST (6ES7132-6FD00-0BB1)

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

SIMATIC. Working with STEP 7. Introduction to STEP 1. The SIMATIC Manager 2. Programming with Symbols. Creating a Program in 4

Quick Start powermanager SENTRON. Software Quick Start powermanager. Introduction. Installation. Starting the project 3

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC NET. S TeleControl MSC300_Library program block library. Block library for TCSB (V3) WDC_S7_300_... (FB92) 2 UDT_WDC_PARAM (UDT91) 3

Siemens Drives & PLCs

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7

First Steps with S7-PDIAG and ProAgent

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

COMOS. Operations MRO. Introduction 1. Maintenance objects 2. "General maintenance" plugins 3. "Events" plugin 4. "Resources" plugin 5


COMOS. Lifecycle 3D Integration Operation. Publisher 1. COMOS PDMS Integration 2. Material management 3. COMOS 3D viewing 4.

Sample project Filling Station SIMATIC. STEP 7 Professional / WinCC Advanced V11 for Sample project Filling Station. Overview of the Getting.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

Siemens Automation Products

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

Transcription:

Getting Started - Commissioning a CPU Introduction 1 31xC: Closed-loop control Preparation 2 SIMATIC S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control Learning units 3 Further Information 4 Getting Started 08/2011 A5E00105534-03

Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the relevant information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E00105534-03 P 09/2011 Copyright Siemens AG 2011. Technical data subject to change

Table of contents 1 Introduction... 5 2 Preparation... 7 3 Learning units... 11 3.1 1. Step: Installing the sample project...11 3.2 2. Step: Linking to the user program...12 3.3 3. Step: Setting parameters...13 3.4 4. Step: Trial run...13 4 Further Information... 15 Getting Started, 08/2011, A5E00105534-03 3

Table of contents 4 Getting Started, 08/2011, A5E00105534-03

Introduction 1 Contents of this Getting Started Manual The practical sample in this Getting Started manual takes you through four steps, showing you how to commission a fully functional application. You are going to learn how to determine and configure application-dependent data and how to operate a control circuit. This process will take one to two hours, depending on your experience. Getting Started, 08/2011, A5E00105534-03 5

Introduction 6 Getting Started, 08/2011, A5E00105534-03

Preparation 2 Scope These instructions apply to the following CPUs: CPU SIMATIC Micro Memory Card required for operation? 313C Yes V3.3 313C-2 PtP yes V3.3 313C-2 DP yes V3.3 314C-2 PtP yes V3.3 314C-2 DP yes V3.3 314C-2 PN/DP yes V3.3 As of firmware version The order number can be found in the manuals, e.g. the operating instructions CPU 31xC and CPU 31x: Installation (http://support.automation.siemens.com/ww/view/en/13008499). Getting Started, 08/2011, A5E00105534-03 7

Preparation Requirements You have an S7-300 station consisting of a power supply module and a CPU 313C or 314C. STEP 7 as of V5.5 is correctly installed on your PG. The table below shows the STEP 7 version you need for each CPU. CPU STEP 7 version 313C STEP 7 as of V5.5 + SP1 or STEP 7 as of V5.3 + SP2 with HSP 203 313C-2 PtP STEP 7 as of V5.5 + SP1 or STEP 7 as of V5.3 + SP2 with HSP 204 313C-2 DP STEP 7 as of V5.5 + SP1 or STEP 7 as of V5.3 + SP2 with HSP 203 314C-2 PtP STEP 7 as of V5.5 + SP1 or STEP 7 as of V5.3 + SP2 with HSP 204 314C-2 DP STEP 7 as of V5.5 + SP1 or STEP 7 as of V5.3 + SP2 with HSP 203 314C-2 PN/DP STEP 7 as of V5.5 with HSP 191 You have downloaded the sample projects from the Internet or have the CD of sample projects included with the Technological Functions operating instructions. You have set up a project for the S7-300 station. The PG is connected to the CPU. The CPU is correctly connected to a power supply. I/O wiring is not required for this sample. WARNING Operation of an S7-300 as part of plants or systems is subject to special rules and regulations, which depend on its field of application. Please make sure that you adhere to the applicable safety and accident prevention regulations, for example IEC 204 (emergency stop systems). You risk severe injury, or damage to machines and equipment if you ignore these regulations. Ensure the S7-300 is completely disconnected before wiring! You can come into contact with live wires if the PS 307 power supply module is turned on or the PS power supply cable is connected to the main power supply. 8 Getting Started, 08/2011, A5E00105534-03

Preparation Layout of the example 1 2 3 1 2 3 4 5 6 7 7 6 5 4 Power supply ON/OFF Mode selector Mounting rail Programming device with STEP 7 software PG cable Connecting cable Clamp for strain relief Figure 2-1 Overview of sample layout Getting Started, 08/2011, A5E00105534-03 9

Preparation 10 Getting Started, 08/2011, A5E00105534-03

Learning units 3 3.1 1. Step: Installing the sample project Introduction When installing the sample project, you have the following options: Installing from CD 1. Take the CD out of the Technological Functions operating instructions. 2. Start the installation program on the CD by double-clicking on the SETUP.EXE file in the SETUP folder. The installation program is started. 3. Now follow the instructions in the installation program. Installing from the Internet 1. Open the directory with the sample projects. 2. Start the installation program by double-clicking the SETUP.EXE file. The installation program is started. 3. Now follow the instructions in the installation program. Getting Started, 08/2011, A5E00105534-03 11

Learning units 3.2 2. Step: Linking to the user program 3.2 2. Step: Linking to the user program Procedure 1. Open the project "ZDt26_04_TF 31xC_PID" in the catalog... \Siemens\STEP7\Examples via "File > Open... > Sample projects" in SIMATIC Manager. A window, divided into two sections, opens showing the title of the project. 2. Double-click the S7 program "Controlling 2 CONT_C". The "Sources", "Blocks" and "Symbols" folders are displayed in the right-hand window. 3. Double-click on the "Blocks" container. All blocks of the S7 program are displayed. 4. With the exception of system data, copy all the blocks to your project under "SIMATIC 300 Station > CPU 3xx > S7 Program > Blocks". Block Name (in the toolbar) Description OB 100 RESTART Restart OB OB 35 CYC_INT5 Time-controlled OB 100 ms SFB 41 CONT_C Continuous-action PID controller FB 100 PROC_C Control circuit for continuous controller DB 100 DI_PROC_C Instance DB for PROC_C DB 101 DI_CONT_C Instance DB for CONT_C VAT1 VAT1 Variable table 12 Getting Started, 08/2011, A5E00105534-03

Learning units 3.3 3. Step: Setting parameters 3.3 3. Step: Setting parameters Procedure 1. Start the parameter assignment interface with SIMATIC/STEP7/PID Control Parameter Assignment. The input dialog "PID Control" is displayed. 2. In PID control, open your project with "File > Open". Select instance DB 101 for SFB 41. Acknowledge the dialog with "OK". You are returned to the parameter assignment screen form. The configured parameters are displayed. Changes to this sample program are not required. 3. Close the parameter assignment screen form with "File > Close". The parameter assignment screen form is closed. 4. In SIMATIC Manager, select "SIMATIC 300 Station > CPU 3xx > S7 Program > Blocks". All blocks of the S7 program are displayed. 5. Download all of the S7 blocks it contains to your CPU via "PLC > Download" (CPU in STOP mode). The program and configuration are downloaded from the PG to the CPU. 3.4 4. Step: Trial run Procedure 1. In the "Blocks" directory, double-click on the variable table "VAT1" in your project. The variable table for monitoring and modifying is displayed. 2. Go online with "PLC > Connect to > Configured CPU". At the bottom right, you will see that the CPU is set to "STOP" mode. 3. Activate monitoring with "Variable > Monitor". The current values of the addresses are displayed in the "Status Value" column. 4. Switch the CPU to RUN. At the bottom right, you will see that the CPU is set to "RUN" mode. The controller is started. 5. Modify the setpoint "SP_INT". You can monitor the output value "OUTV" that is proportional to the setpoint "SP_INT". 6. Call the STEP 7 tool PID Control (see step 3). Select instance DB 101 and click "Online" mode. In the "Test" menu, select and start the "Curve plotter" function. You can view the graphic profile of some of the control variables (actual value, setpoint, control offset, etc.). Getting Started, 08/2011, A5E00105534-03 13

Learning units 3.4 4. Step: Trial run 14 Getting Started, 08/2011, A5E00105534-03

Further Information 4 Diagnostics/Correction of Errors Incorrect operator input or inconsistent configuration data may lead to errors. For information on how to analyze such errors and messages, refer to the S7-300 documentation. Example: The "ZEn26_04_TF 31xC_PID" project contains further samples you can use for orientation. You can customize all samples according to your personal applications. Getting Started, 08/2011, A5E00105534-03 15

Further Information 16 Getting Started, 08/2011, A5E00105534-03