Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products. Sheetal Kochavara Systems Engineer, EMC Corporation

Similar documents
VMware with CLARiiON. Sheetal Kochavara

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Business Continuity for Microsoft Applications

Introduction to Using EMC Celerra with VMware vsphere 4

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution. Enabled by EMC Celerra and Linux using FCP and NFS. Reference Architecture

ESX Server Storage II

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

EMC SAN Copy Command Line Interfaces

VMware ESX Server Using EMC CLARiiON Storage Systems Solutions Guide

VMware ESX Server Using EMC Symmetrix Storage Systems Solutions Guide

EMC Integrated Infrastructure for VMware. Business Continuity

VMware vsphere with ESX 4.1 and vcenter 4.1

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15

ADC0063 How KMD Designed its Virtual Infrastructure for a High-Availability Environment. Alan Madsen KMD, System Engineer

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

EMC Virtual Infrastructure for Microsoft Exchange 2007

Storage Compatibility Guide for ESX Server 3.0

Using EMC Celerra Storage with VMware vsphere and VMware Infrastructure

Configuring and Managing Virtual Storage

Rrootshell Technologiiss Pvt Ltd.

E EMC. EMC Storage and Information Infrastructure Expert for Technology Architects

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S

VMware vsphere with ESX 4 and vcenter

Johnson Controls, Inc. Managing your Virtual Infrastructure Level 3. Phillip Cramer Manager Windows Server Environment

EMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA

VMware vsphere 5.5 Advanced Administration

By the end of the class, attendees will have learned the skills, and best practices of virtualization. Attendees

Storage / SAN Compatibility Guide For ESX Server 3.x

VMware Overview VMware Infrastructure 3: Install and Configure Rev C Copyright 2007 VMware, Inc. All rights reserved.

VMware - VMware vsphere: Install, Configure, Manage [V6.7]

EMC Plugins for VMware vsphere

Transitioning Exchange 2003 to VMware Virtual Exchange 2007 Using EMC CLARiiON or EMC Celerra

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

Information Storage and Management

EMC Business Continuity for Oracle Database 11g

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ]

VMware vsphere: Install, Configure, Manage (vsphere ICM 6.7)

White Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft

Best Practices for designing Farms and Clusters

Disaster Recovery of Microsoft Exchange Server 2007 on EMC Celerra iscsi using EMC Replication Manager and VMware vcenter Site Recovery Manager

Introduction to the CX700

EMC Virtual Architecture for Microsoft SharePoint Server Reference Architecture

EMC Exam E VNX Solutions Specialist Exam for Implementation Engineers Version: 9.0 [ Total Questions: 411 ]

EMC Solutions for Oracle Database 10g/11g for Midsize Enterprises EMC Celerra NS Series Multi-Protocol Storage System

Virtualizing Oracle Database 10g/11g on VMware Infrastructure

EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S

Virtualizing Microsoft Exchange Server 2010 with NetApp and VMware

VMware vsphere with ESX 6 and vcenter 6

VMware vsphere 6.5 Boot Camp

Storage / SAN Compatibility Guide For ESX Server 3.5 and ESX Server 3i

Complete Data Protection for VMware Virtual Environments

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

"Charting the Course... VMware vsphere 6.7 Boot Camp. Course Summary

EMC Backup and Recovery for Microsoft SQL Server

INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5

VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S

The Virtualization Transformation

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture.

DATA PROTECTION IN A ROBO ENVIRONMENT

EMC Symmetrix DMX Series The High End Platform. Tom Gorodecki EMC

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

PAC532 iscsi and NAS in ESX Server 3.0. Andy Banta Senior Storage Engineer VMware

Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems

Exploring Options for Virtualized Disaster Recovery

Availability & Resource

Reference Architecture

Vmware VCP-310. VMware Certified Professional on VI3.

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005

EMC Celerra Unified Storage Platforms

Exam4Tests. Latest exam questions & answers help you to pass IT exam test easily

Increase Scalability for Virtual Desktops with EMC Symmetrix FAST VP and VMware VAAI

Exam Name: Technology Architect Solutions Design Exam

VCP410 VMware vsphere Cue Cards

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Overview. Prerequisites. VMware vsphere 6.5 Optimize, Upgrade, Troubleshoot

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

VMware vsphere 4. Architecture VMware Inc. All rights reserved

EMC RECOVERPOINT/EX Applied Technology

Setup for Failover Clustering and Microsoft Cluster Service

EMC Corporation. Tony Takazawa Vice President, EMC Investor Relations. August 5, 2008

Recommendations for Aligning VMFS Partitions

Future Datacenter. Žaneta Findrik Nöthig Presales Manager. David Hanáček vspecialist Technical Lead

VMware vsphere 6.5: Install, Configure, Manage (5 Days)

EMC Celerra CNS with CLARiiON Storage

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March

Replication is the process of creating an

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

Improving Blade Economics with Virtualization

Virtual Volumes FAQs First Published On: Last Updated On:

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

VMware vsphere: Fast Track [V6.7] (VWVSFT)

Copyright 2012 EMC Corporation. All rights reserved.

Chapter 11. SnapProtect Technology

EMC CLARiiON CX3 UltraScale Series The Proven Midrange Storage

Transcription:

Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products Sheetal Kochavara Systems Engineer, EMC Corporation

Agenda Overview of EMC Hardware and Software Best practices with VMware ESX 3.0.x and ESX 2.5.x Connectivity Performance Business Continuity and Backup Customer Case Study

EMC Symmetrix DMX Hardware Series Industry's Broadest and Most Powerful High-end Storage Family DMX-3 INCREMENTAL SCALABILITY DMX-2 DMX800 DMX1000 Architecture Performance Availability Functionality Economics Revolutionary and extensible Proven market leadership Continuous comprehensive Industry s broadest suite Optimized TCO

EMC CLARiiON Hardware Series 2 0 0 5 C L A R i i O N F A M I L Y 2 0 0 6 C L A R i i O N F A M I L Y C O M P L E T E R A N G E O F A F F O R D A B L E A N D E A S Y - T O - U S E S T O R A G E P L A T F O R M S CLARiiON Disk Library CLARiiON CLARiiON CLARiiON CLARiiON AX SeriesDisk Library CX SeriesAX Series CLARiiON CX3 UltraScale Series DL210 DL7X0 AX150DL310 CX300 DL7X0 CX500AX100 CX700 AX150i CX300i CX500i AX100i CX3-20/ CX3-20C CX3-40/ CX3-40C CX3-80 Proven software functionality

EMC Celerra Hardware Series Broadest Range of NAS Products NS350 NS500 NS700 NS40 NS704 NS80 NS500G NS700G NS40G NS704G NS80G NSX High availability Advanced clustering High availability Advanced clustering Advanced clustering One or two Data Movers Four Data Movers One or two Data Movers Four Data Movers Four to eight X-Blades Upgradeable to gateway Upgradeable to gateway NAS gateway to SAN NAS gateway to SAN NAS gateway to SAN Integrated CLARiiON Integrated CLARiiON CLARiiON, Symmetrix CLARiiON, Symmetrix CLARiiON, Symmetrix

EMC Array Software Symmetrix CLARiiON Celerra Management ControlCenter Navisphere Manager Celerra Manager Symm CLI Performance Analyzer Navisphere CLI Navisphere Analyzer - Performance Monitoring Navisphere Quality Server Manager Aggregate software Metavolumes Optimizer MetaLUNs LUN Migration Virtual provisioning Volume Manager Replication TimeFinder Snap SnapView Snapshots SnapSure TimeFinder BCVs SnapView Clones IP replication TimeFinder Mirror MirrorView/S - Celerra Replicator SRDF/S MirrorView/A SAN replication SRDF/A and SRDF/AR SAN Copy - SRDF\SRDF/A Open Replicator - MirrorView/S

Agenda Overview of EMC Hardware and Software Best practices with VMware ESX 3.0.x and ESX 2.5.x Connectivity Performance Business Continuity and Backup Customer Case Study

Connectivity - Boot from SAN ESX boot from SAN (Fibre Channel (FC)) Use RAID 1/RAID 1/0 (highest level of availability) Use RAID 5 (optimal capacity/performance ratio) Boot LUN size (Service Console swap space) iscsi boot using hardware initiator (Q4-06/Q1-07) RDM supported with ESX 3.x boot Virtual Machines (VMs) VM boot from SAN (FC and iscsi) CLARiiON and Celerra iscsi ESX iscsi software-initiator supported Support for hardware initiator Q4-06/Q1-07 OS/application Use RAID 1/RAID 1/0(highest level of availability) Use RAID 5 (optimal capacity/performance ratio) Each VM has it s own swap space for ESX 3.x Place swap with OS (default settings) ESX Server ESX Boot VMs VMs VM Boot

Connectivity - Boot from SAN (contd. ) Celerra NFS boot options Boot ESX from local device, SAN or iscsi Boot and provision storage for VMs from Celerra using NFS Requirement for VMotion/DRS/VMware HA NFS version 3 over TCP only (no version 2, no UDP) Use RAID 5 or RAID 1 Place swap files on SAN, iscsi or local storage Be careful when using lower-tier (e.g. ATA) disks for boot Targeted for sequential I/O workload Swap file I/O characteristics is random Separate LUN(s) for templates, ISO images Can use iscsi, NFS or ATA

Connectivity Multipathing\Failover (Fibre Channel) VMware s native multipath software Symmetrix (Fixed policy) CLARiiON (MRU policy) Zoning Single initiator (HBA) zoning Static load balancing for Symmetrix Balance load across FAs and HBAs Online Code Upgrades supported CLARiiON Recommended that each HBA have access to both SPs H B A 0 0 1 2 3 SP A VMware ESX Server H B A 1 0 1 2 3 SP B Mirrored Cache

Single SP access to each HBA issue for active-passive arrays H B A 0 VMware ESX Server 1 H B A 1 LUN configured as VMFS vmdk1 vmdk2 H B A 0 VMware ESX Server 2 H B A 1 0 1 2 3 CONTROLLER A 0 1 2 3 CONTROLLER B Mirrored Cache

Connectivity Multipathing\Failover (CLARiiON iscsi) VMware s native multipath software CLARiiON (MRU policy) Enable NIC Teaming Common termination point Use dedicated Vswitches/VLANs iscsi traffic iscsi Hardware initiator Each HBA have access to both SPs Online Code Upgrades supported NIC Teaming SP A HN BI AC 01 0 1 2 3 VMware ESX Server HN BI AC 12 0 1 2 3 SP B Mirrored Cache

Connectivity Multipathing\Failover (NFS and Celerra iscsi) VMware s native multipath software Fail-safe network implementation iscsi and NFS Use dedicated Vswitches and/or VLANs iscsi traffic Internal locking protocol [NFS] Lease-based Protects against data corruption Security [NFS] Standard AUTH_UNIX/AUTH_HOST security NIC Teaming Failsafe Network N I C 1 VMware ESX Server N I C 2 0 1 2 3 Celerra Data Mover Mirrored Cache

Performance Considerations (Fibre Channel and iscsi) Configuration for LUN Layout Avoid using same set of disks for different applications I/O characteristics LUNs should be sized according to anticipated I/O workload Recommended LUN size should be less or equal to 500GB Option to spread load across multiple physical disks for capacity and expansion for application data volumes Symmetrix Metavolumes, CLARiiON MetaLUNs or Celerra Striped Volumes Maximum LUNs per VirtualCenter farm or cluster Dependent on number of ESX servers and VM workload

Performance Considerations (Fibre Channel and iscsi) ( Contd.) Configuration for VM OS/application Use VMFS volumes to avoid increase in LUN count Fibre Channel recommendations Maximum 16 ESX servers and 32 I/O-intensive VMs per VMFS volume Recommended: Each VMFS volume should not contain more that 10-15 VMs To avoid SCSI-reservation issues and queuing Factor in number and type of back-end disks Reserve space for VMware snapshots See replication best practices for VMFS volumes (slide 23) iscsi recommendations Half the number of VMs that are recommended for Fibre Channel

Performance Considerations (Fibre Channel and iscsi) ( Contd.) Managing data for I/O intensive application Separate LUNs for OS/app and application data Use RDM or present the entire VMFS volume (virtual disk) to the VM Follow best practice recommendations for a physical server Align application data disks at Virtual Machine Level for ESX 3.x For VMFS and RDM virtual disks Use VirtualCenter to create VMFS volumes for filesystem alignment

Tests conducted on misaligned and aligned VMFS volumes 10-12% increase in throughout Throug h p ut ( M B/sec) 180 160 140 120 100 80 60 40 Seq Writes Seq Reads Random Writes Random Reads Throug h p ut ( M B /s e c ) 200 180 160 140 120 100 80 60 40 Seq Writes Seq Reads Random Writes Random Reads 20 20 0 1 4 8 16 32 64 72 128 0 1 4 8 16 32 64 72 128 IO size (KB) IO size (KB) VMFS Misaligned - RAID 5 VMFS aligned to 64K - RAID 5

Celerra Performance Considerations (NFS) Use TCP mount options with read and write buffer size=32k Use VLAN for ESX Storage interfaces Avoid VM swapping to NFS volumes Edit VM config file to add sched.swap.dir Place swap on SAN, iscsi or local 8 NFS mounts per ESX Server allowed by default. To increase: Select host from inventory, right-click Advanced Settings, select NFS Adjust NFS.MaxVolumes

Array-based Replication and ESX Server Interoperability Symmetrix and CLARiiON replication products are supported with RDMs and VMFS volumes Guest operating system images, as well as the application data, can be replicated Both VMFS and RDM volumes, the replica can be presented to the same ESX Server with ESX 3.x For ESX 2.5.x, only replicas of RDM volumes can be presented back to the same ESX server Allows one VM to use the production LUN, and another VM on the same ESX Server to access the replica ESX Server HARDWARE SOFTWARE Replica of Windows app data Linux app data VMware: Virtualization layer x86 architecture Windows app data CLARiiON

Array-based Fibre Channel Replication Considerations VMFS or RDM for application data? Use VMFS if: You wish to administer less LUNs, easy provisioning of VM Replicate entire VMFS volume along with all its virtual disks Crash-consistent replica if not all virtual disks are application quiesced Support for VMware snapshots is required Using VMware Consolidate Backup (VCB) Using VirtualCenter cloning Use RDM [physical compatibility mode] if: Replicating application data to and from a physical to virtual infrastructure SAN Replication software tools to run inside virtual machines admsnap, admhost etc. No support for VMware snapshots For virtual machine clustering between physical servers Online expansion using arraybased expansion technology

Array-based Fibre Channel Replication Considerations (Contd.) Use array-based consistency technology Groups of multiple LUNs Replicate OS\application and application data LUNs Applications distributed across many LUNs e.g. databases, volume managers (VMFS spanning) Flush buffers Host, disk, database buffers before replication Use EMC-based tools to flush disk buffers Replication of VM OS images Replica crash-consistent if VM not powered down

Array-based iscsi Replication Considerations CLARiiON iscsi ESX iscsi software and hardware (Q4-06/Q1-07) initiator Replication granularity entire VMFS volume Similar replication considerations as Fibre Channel VM iscsi software initiator Replication granularity VM virtual disk Replica presented to a different VM (same or different ESX server) Celerra iscsi ESX iscsi software and hardware (Q4-06/Q1-07) initiator Use Celerra Replicator (RDM volumes) Support for Replication Manager/SE (RDM only) VM iscsi software initiator Replication granularity VM virtual disk Support for Replication Manager/SE

Array-based Replication NFS Considerations Integration with array replication technologies Symmetrix SRDF/S, SRDF/A, CLARiiON MirrorView/S Celerra Replicator offers asynchronous volume based option Replication granularity is entire NFS volume Snapsure can be used with NFS for checkpoints Replication granularity is entire NFS volume

Implementing array-based replication of VMFS volumes with ESX 3.0 Replica assigned to different ESX server For both local and remote array-based replication Recommended Set the LVM.EnableResignature parameter to 0 Set the LVM.Disallowsnapshotlun to 0 Within VirtualCenter, place destination ESX server in a different datacenter object Local Replication (application data volume) Ensure that the target VMFS is not accessed No command to un-mount a VMFS volume Remote Replication Destination VM is not powered on unless there is a disaster

Agenda Overview of EMC Hardware and array-based software Best practices for implementing EMC storage with VMware ESX 3.0.x Connectivity Performance Business Continuity and Backup Customer Case Study

Case Study - Customer consolidation About ABC Corporation Headquarters in Pennsylvania, US IT service department Applications SQL Server Web servers File Share Servers Home grown applications Initial environment CLARiiON running on VMware ESX 2.5.x Host-level Virtual Machine Backup

Requirements Need for more Virtual Machines (servers) running of Windows 2003 and Windows 2000 Required another SAN array for running other OSs and applications Maxed out the capacity of their existing CLARiiON system Wanted to deploy ESX 3.0 in the environment VMware Distributed scheduling VMware High Availability Needed a remote replication solution for disaster recovery at a remote site 20 miles apart from primary site

Implementation Three VMware ESX 3.0 servers HP DL580 (G4) servers Total: 10 Windows virtual machines Proposed CX3-20 at the primary site with 60 drives Virtual Machines booting from CLARiiON LUNs configured as VMFS volumes Host LUN ID is identical across all ESX servers Shared across the 3 ESX servers for VMotion, VMware HA, DRS MirrorView/A for disaster recovery to another CX3-20 system 20 miles from primary site Cisco 9216i over T3 line ( FC over IP) Replicating SQL Database RPO ~ 4 hours

LUN Layout for VMware ESX Data Volume: 668 GB Log Volume 400 GB Boot Volume: 133 GB

HARDWARE SOFTWARE HARDWARE SOFTWARE Final Implementation Diagram CX3-20 Production ESX servers VMware: Virtualization layer Intel architecture HARDWARE SOFTWARE VMware: Virtualization layer Intel architecture VMware: Virtualization layer Intel architecture Production CLARiiON Boot Data Log MirrorView Asynchronous [20 miles] Cisco MDS 9216i Cisco MDS 9216i CX3-20 Secondary CLARiiON Remote replica of Boot Remote replica of Data Remote replica of Log Disaster Recovery ESX servers HARDWARE SOFTWARE VMware: Virtualization layer Intel architecture HARDWARE SOFTWARE VMware: Virtualization layer Consistency Group

Customer s Future Plans Current Backup strategy includes individual VM backup Incremental Backup during the week Full Backup on the weekend Looking at VMware Consolidated Backup Looking at installing SnapView on the remote CX3-20 system Take Snapshots of their target MirrorView/A volumes For test and development

References Data Migrations and Data Vaulting using EMC Open Replicator, EMC SAN Copy 11:45 12:45 (11/08/2006) Introduction to Networked Storage Performance in a Virtualized environment 3:15 4:15 (11/07/2006) VMware ESX server and Storage Architecture Best Practices for Performance, Backup and Disaster Recovery 4:45 5:45 (11/08/2006) EMC Documentation on vmware.com VMware ESX Server Using EMC Symmetrix Storage Systems VMware ESX Server Using EMC CLARiiON Storage Systems CLARiiON and VMware integration whitepaper Celerra FAQ document

Presentation Download Please remember to complete your session evaluation form and return it to the room monitors as you exit the session The presentation for this session can be downloaded at http://www.vmware.com/vmtn/vmworld/sessions/ Enter the following to download (case-sensitive): Username: cbv_rep Password: cbvfor9v9r