This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

Similar documents
This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

This Datasheet for the IC660BBD022. Block 24Vdc Source I/O 16 Circuits, 2/3 Wire Sensor Compatible

This Datasheet for the IC660BBS103. Block 115Vac/125Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit.

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Shown with terminal block Supports diagnostic point fault contacts in the logic program

Analog Input, 16-Bit Thermocouple Module

VersaMax* Analog Input, 16-Bit Thermocouple Module

This Datasheet is for the IC693ALG390. Memory Backup and Backup Battery.

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

PLC Racks IC697CHS782/783


This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect

PACSystems RX7i IC698CHS009/119

PV Rapid Shutdown device

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

GE Fanuc IC694ALG391. Rx3i PacSystem

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

User's Guide. Model W 3-in-1 Switching DC Power Supply

GE Fanuc IC694ALG221. Rx3i PacSystem

16-Channel Digital Output Module 120Vac/dc

Digital ac/dc (24V) Input Module

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

PACSystems* RX3i IC694ALG232

PACSystems* RX3i IC694ALG233

Analog Voltage Combination Module

GFK-2415A March Type of sensor connection

Installation Instructions

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

GE Fanuc IC695ALG708. Rx3i PacSystem

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Junos WebApp Secure 5.0 Hardware Guide

EX-RC1 Remote I/O Adapter

INSTALLATION MANUAL SLI 50 INVERTER

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

IC693 PLC IC693ACC350, IC693ACC340/341

PS/IO Circuit Board Retrofit

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

This Datasheet for the IC660BSM120. BUS Switching Module 115Vac/125Vdc.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Installation Instructions

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

This Datasheet for the IC670MDL VAC 16 Pt. Input Grouped.

PACSystems* RX3i IC695PSA140

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

This Datasheet for the IC670MDL VAC 8 Pt. Isolated Input.

EX-RC1 Remote I/O Adapter

MT8050iE series. Installation Instruction (1) (2)

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

PACSystems RX3i IC695PSA140

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

Installation Instructions

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

DMC-1000 Chassis-Based Media Converter

Technical Manual SMART TRAC PS Card

CTI 2552-A 8-CHANNEL ISOLATED RTD INPUT MODULE INSTALLATION AND OPERATION GUIDE. Ver. 1.2 CTI Part #

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

Installing the Cisco AS5400XM Universal Gateway

Power Supply and Fan Module Installation

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

V E62B Snap-in I/O Module

DESIGN SPECIFICATION # R1 Model AHRS-500 P/N ARINC 407 TO ARINC 429 ADAPTOR CTRL # /17/96

Dell SC7020 Storage Controller Getting Started Guide

Operation and Maintenance Manual

Site Preparation CHAPTER

32-Channel Analogue Input Module Differential Input

Installation Job Aid for Ethernet Routing Switch 3600 Series

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.

S66 Series Electronic Fan Speed Control

InView Marquee Message Display

General Specifications. P2-08THM Analog Input

Tempco Instruction Manual

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

ICS Regent. Thermocouple Input Assembly. Input Module, Mux, Termination Panel and Cable (T3431-IM, T3431-Mux, T3431-TP and T3431-CA) PD-6024

Power Supply Installation

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Specifications, Installation, and Operating Instructions

Trusted High Integrity Power Supply System ( Vac and 24 Vdc)

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

PanelView Plus/VersaView CE Terminals and Display Modules

User safety and equipment protection guidelines

Transcription:

This Datasheet for the IC660BBA101 Block 115Vac/125Vdc RTD Input 6 Channels http://www.qualitrol.com/shop/p-14423-ic660bba101.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-30 module. For further information, please contact Qualitrol Technical Support at 1-800-784-9385 support@qualitrol.com

Description RTD Input blocks monitor temperature inputs from Resistive Temperature Detectors (RTDs). Two RTD blocks are available: 15 VAC/125 VDC RTD Block (IC66*BBA101) 24/48 VDC RTD Block (IC66*BBA021) They are identical except for the power supply. RTD Input (115VAC/125VDC.1A Max) Features An RTD Input block has six input circuits, in three groups of two circuits each. Group to group isolation is 300 volts. Each input can be used with platinum, nickel, or copper RTDs. Input data for each circuit is linearized according to the type of RTD selected. Input data is reported to the CPU in engineering units of tenths of degrees Celsius, tenths of degrees Fahrenheit, tenths of Ohms, or counts. Additional configurable features include: Alarm thresholds RTD resistance Alpha type Linearization Input filter time RTD blocks are factory-calibrated; there is no need for subsequent recalibration. In addition, the block s automatic diagnostics can pinpoint the cause of installation and run-time errors: Input Short detection Internal Fault detection Wiring Error detection Open Wire detection Overrange and Underrange input indication High and Low input alarms Fault reporting can be enabled or disabled circuit-by-circuit. Using this Datasheet This datasheet summarizes information about block installation, configuration, and diagnostics. Your primary reference should be the Discrete and Analog Blocks User s Manual. It includes detailed instructions for block installation and configuration. For additional information about systems and communications, including bus specifications, refer to the I/O System and Communications Manual. Specifications Catalog Numbers 115 VAC/125 VDC RTD Block Terminal Assembly Electronics Assembly 24/48 VDC RTD Block Terminal Assembly Electronics Assembly Block Specifications Size (height x width x depth) Weight LEDs (I/O Block) Block to Block Isolation Group to Group Isolation Heat Dissipation IC66*BBA101 IC66*TBA101 IC66*EBA101 C66*BBA021 IC66*TBA021 IC66*EBA021 8.83 (22.44cm) x 3.34 (8.48cm) x 3.91 (9.93cm) 4 lbs. (1.8 kg) Unit OK, I/O Enabled 1500V 300V 7W maximum Block 115VAC 125VDC 24/48VDC supply voltage (@ 7W) 93-132 VAC 47-63 Hz 105-145 VDC 10% max. ripple supply dropout time 1 cycle 10ms 10ms Input Specifications Input resolution Absolute accuracy (at 25 C)* Platinum or Nickel 10W Copper: Input update frequency Input filter ranges (per block) RTD linearization Resistance measurement range Diagnostics 0.1 C +/-0.5 C typical, +/-1.0 C maximum +/-5 C typical, +/-10 C maximum Once every 400ms, 800ms, or 1600ms 400ms, 800ms, 1600ms 18-56 VDC 10% max. ripple Platinum (DIN 43760), Nickel (DIN 43760), Copper, Linear 0 to 5000 Ohms Input shorted, Internal fault, Wiring error, Open wire, Overrange, Underrange, High Alarm, Low Alarm Refer to GFK-0867 for product standards and general specifications. *In the presence of severe RF interference (IEC 801-3, 10 V/m), accuracy may be degraded to +/- (0.5% of full scale reading, plus 0.5% of reading). Compatibility Hand-held Monitor IC66*HHM501D, version 3.5 (or later) is required. For an IC697 series PLC, the CPU may be rel. 1 (IC697CPU731 or 771) or later. The bus controller may be rel. 1 (IC697BEM731) or later. For an IC600 series PLC, the CPU must be rev. 105 or later. For a IC600 series Plus PLC, rev. 110 or later is required. The programming software must be Logicmaster 6 rel. 4.02 or later. For an IC550 series PLC, the CPU must be rev. 3.0 or later. The programming software must be rel. 2.01 or later. 1

Installation Instructions Carefully inspect all shipping containers for damage. If any equipment is damaged, notify the delivery service immediately. Save the damaged shipping container for inspection by the delivery service. After unpacking the equipment, record all serial numbers. Save the shipping containers and packing material in case it is necessary to transport or ship any part of the system. Block Mounting Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave at least 2 inches of space between blocks. Mount the block by drilling two screw or bolt holes for 8-32 hardware. Position the block so that the notches in the upper and lower flanges line up with the mounting holes. Mount the block using 8-32 screws. Use star washers to provide ground integrity. Grounding The block s mounting screws must not be used as the only means of grounding the block. Connect the green ground screw on the block to a reliable ground system using a short wire lead, minimum size AWG #12 (avg 3.3mm 2 in cross-section). Warning If mounting screws do not make good ground connection and the ground screw is not connected to a reliable ground, the block is not grounded. Electrical shock hazard exists. Death or personal injury may result. Block Wiring Do not overtorque the terminal screws. Recommended torque for all terminals is 6 in/lb (.678 N/M). Serial Bus Wiring Terminals 1 to 4 are for the serial bus. These terminals accept one AWG #12 wire (avg 3.3mm 2 cross-section) or two AWG #14 wires (each avg 2.1mm 2 in cross-section). The minimum recommended wire size is AWG #22 (avg.36mm 2 in cross-section). Terminals 1-4 can also accommodate spade or ring terminals up to 0.27 inch (6.85mm) wide with a minimum opening for a #6 screw, and up to 0.20 inch (5.1mm) depth from the screw center to the back barrier. Be sure unshielded wire ends are not longer than 2 inches (5 cm). Using one of the cable types recommended in the System and Communications User s Manual, connect the serial bus to terminals 1-4. 1 2 3 4 SERIAL 1 SERIAL 2 SHIELD IN SHIELD OUT If the block is at either end of the bus, connect a terminating resistor of the appropriate type (see the System and Communications User s Manual for details) across its Serial 1 and Serial 2 terminals. Terminating Resistor Serial 1 Serial 2 Shield In Shield Out Start of Bus End of Bus Terminating Resistor Serial 1 Serial 2 Shield In Shield Out Field Wiring Terminals 5 to 32 are for field devices. They take a single wire up to AWG #14 (avg 2.1mm 2 in cross-section). Minimum recommended size is AWG #20 (avg.54mm 2 in cross-section). Wiring for Block For block power, connect the power source to terminals 6 and 7. For an AC block, connect the AC source to the HOT terminal and neutral to the NEUT terminal. For a DC block, connect the DC source to the DC+ terminal and the return to the DC- terminal. The ground (GND) terminal (5) is for block safety. It is connected to the block chassis. Wiring for Input Devices There are 4 terminals available for each input device: a,,, and input. Connect RTDs between the and terminals. The input is used for lead wire compensation of a 3-wire RTD. For a 3-wire RTD, connect the third wire to the terminal. For 2-wire RTDs, short the terminal to the terminal. 2-WIRE RTD 3-WIRE RTD 2-WIRE RTD 3-WIRE RTD RED BLK BLK 5 GND 6 7 8 NC 9 10 11 12 13 14 15 16 22 23 24 25 31 32 17 18 19 20 21 26 27 28 29 30 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Each circuit also has a terminal for shield termination, if desired. This terminal is internally connected to the block chassis and to the input power safety ground terminal. 2

Noise Suppression If noise spikes exceeding 4000 volts will be present in the system, additional noise suppression is needed to protect the block. This can be provided by physically separating and shielding the RTD input leads from any noise source. Alternatively, metal oxide varistors can be installed between and GND. See the I/O System and Communications Manual and Discrete and Analog Blocks User s Manual for additional information. Removing an Electronics Assembly The block s Electronics Assembly can be replaced with a compatible model without removing field wiring or reconfiguring the block. Retaining Screws (Qty. 2) Electronics Assembly Block Operation For each pair of inputs, a multiplexer switches the A/D converter between the RTD inputs and internal reference resistors that are used for self-calibration. The following diagram shows one pair of inputs. RTD RTD Isolated DC MUX Rectifier / Regulator A/D Converter AMP Current Source Reference Resistors Transformer SVFC Quad Regulator Processor Input Serial Bus Terminal Assembly Connector Pins 1. Unscrew the retaining screws at the top and bottom of the block. 2. Using a Block Puller (IC660BLM507), engage the tabs in the first vent slots. Move the tool to the center of the block and squeeze the handle. 3. Pull the Electronics Assembly upward. Warning If power is applied to the field terminals, power is also exposed on the connector pins at the base of the Terminal Assembly, and electrical shock hazard exists. Do not touch the connector pins! Death or injury may result. Inserting an Electronics Assembly 1. Align the Electronics Assembly in the guides and push down firmly. Caution Do not exert excessive force; it may damage the block. 2. If unusual resistance is met, remove the Electronics Assembly. If power is applied to the block, DO NOT TOUCH THE CONNECTOR PINS! Inspect the Terminal Assembly, connector receptacle, and connector edge board (on the Electronics Assembly). Be sure the keying matches. Remove any obstacles and reinsert the Electronics Assembly. Pay close attention to the alignment of the guide pins. 3. Secure the Electronics Assembly with the screws on the top and bottom of the Terminal Assembly. Note: If the Electronics Assembly has been removed from a block for some length of time, contaminants may have built up on the exposed connector pins. After the block is reassembled, these contaminants could affect the accuracy of measurements. When reassembling the block, push the Electronics Assembly in and out a few times to assure a fresh mating surface. -couplers isolate the control and clock signals; a small transformer isolates the circuit power. A synchronous voltage-to-frequency converter changes the measured signals to the proportional frequency sent via an opto-coupler to the processor. The processor s frequency counter converts this synchronous frequency to a 16-bit binary number. The processor corrects each input measurement for lead resistance and for internal offset and gain drifts as it converts the input to an ohmic value. This value is either reported as is, or linearized according to the RTD type selected and converted to a value in degrees. The per channel update rate (input filter time) is preset. It may be 400, 800, or 1600 milliseconds. These selections provide 14, 15, or 16 bit resolution of the measurement. LEDs The block's Unit OK and I/O Enabled LEDs show its operating status: Unit OK I/O Meaning Enabled ON ON Block functioning, CPU communicating ON OFF Block functioning No CPU communications for 3 bus scans ON Blinking Block functioning, Circuit forced Blinking ON Circuit fault, CPU communicating Blinking OFF Circuit fault No CPU communications for 3 bus scans Alternate Blinking Circuit fault, Circuit forced Synchronous Blinking No CPU communications - block number conflict OFF OFF No block power, or block faulty 3

Diagnostics The block s advanced diagnostics provide the messages listed below. Fault messages can be cleared from the Hand-held Monitor or the CPU. Input Shorted: Input circuit measurement below the minimum expected for RTD type. May indicate a fault in the wiring or in the RTD. Internal Fault: One or more of the internal auto-calibration readings for a pair of channels is out of tolerance. The block reports a value of zero for each channel of the faulty pair. The block s Electronics Assembly should be replaced. Wiring Error: Connections between the RTD and the block s Terminal Assembly are incorrect. This may cause faulty input data to be reported. Field wiring should be changed to match the wiring diagram indicated on the block s faceplate. Open Wire: Less current than expected for the input type on that circuit. An Open Wire diagnostic may also mean that the input circuit excitation current is not present. The RTD may be missing or faulty, or the RTD is not connected to the block. Overrange: The Celsius or Fahrenheit input value exceeds expected maximum positive value (limits are 850 C or 1562 F for platinum, 250 C or 482 F for nickel, +3276.7 C or +3276.7 F otherwise). This only occurs when converting to units of temperature. Underrange: The Celsius or Fahrenheit value exceeds expected maximum negative value (limits are -200 C or -328 F for platinum, - 60 C or -76 F for nickel, -3276.7 C or -3276.7 F otherwise). Low Alarm/High Alarm: Individual low and high alarm thresholds can be configured for each input. If an input reaches one of its alarm thresholds, the block reports a Low Alarm or High Alarm diagnostic. The diagnostic is triggered upon reaching the limit and is repeated until circuit faults are cleared. Configuration First, the block must be configured with a Hand-held Monitor to: Enter its Device Number (serial bus address). Enter its Reference Number (required only for IC600 and IC550 series PLCs only). Note: If a block is configured offline, it must be properly grounded and have a 75 Ohm resistor installed across its Serial 1 and Serial 2 terminals. See the Discrete and Analog I/O Blocks User s Manual for instructions. The rest of the features can be configured either using a Hand-held Monitor, or by sending a Write Configuration datagram to the block from the host. Feature Circuit or Block Factory Setting Selections Device Number Block null 0 to 31 (a number must be selected) Reference Address Block none Depends on host CPU type Baud Rate Block 153.6 std 153.6 std, 153.6 ext, 76.8, 38.4 Kbd Channel Active Circuit yes yes, no Report Faults Circuit yes yes/no Linearization Circuit Platinum Platinum, Nickel, Copper, Linear RTD Resistance Circuit 100.0 Ohms 5.0-2000.0 Ohms Alpha Type Circuit 0.003850 0.00100-0.007000 Low Alarm Circuit -200 C -32,767 to +32,767 or 0 to +65,535 High Alarm Circuit +800 C -32,767 to +32,767 or 0 to +65,535 Input Filter Time Block 1600ms 400, 800, 1600ms Units Block Celsius Celsius, Fahrenheit, Ohms, counts Configuration Protection Block disabled enabled, disabled 4