3all environmental impact and business enabling green benefits that

Similar documents
Hbusiness enabling green benefits that the A G SI offers to its

3Com Switch 4800G/H3C 5500-EI 24-Port and 48-Port switches

Hewlett-Packard* E4800G 24-Port and 48-Port switches were

Lab Testing Summary Report

H3C S5800 Series and S5820X Switches were evaluated by

Lab Testing Summary Report

3Com Switch 7906E/H3C S7506E was evaluated by Miercom under

Hewlett-Packard s ProCurve 1810 Series Switches were evaluated

Hewlett-Packard* A5800 Series and A5820 Switches were

Hewlett-Packard* A7506 Ethernet Switch was evaluated by

Hewlett-Packard s ProCurve 2520 Series Switches were evaluated

Hewlett Packard s ProCurve 5406zl switch was evaluated by

Huawei Technologies requested Miercom evaluate the

Huawei Technologies engaged Miercom to evaluate the S2700-EI

Huawei Technologies engaged Miercom to conduct an evaluation

Cisco engaged Miercom to verify the performance and advanced

Huawei Technologies engaged Miercom to evaluate several series

Huawei Technologies engaged Miercom to conduct an

WildPackets TimeLine network recorder featuring the OmniPeek

Dell Networking S6000

Aruba Networks engaged Miercom to provide an independent

Huawei Technologies engaged Miercom to evaluate the S12700

CSince XenDesktop 4 Enterprise and Platinum editions offer many other

Huawei Technologies engaged Miercom to evaluate the S9300

Performance & Interoperability Dell Networking 7000 and 8100 Switch Series

Summary. Controller. Product. Category: Vendor Tested: a rate. Sonus Network while. Report scenarios. uses 48VDC NBS9000.

Lab Testing Summary Report

Sonus Networks engaged Miercom to evaluate the call handling

Lab Testing Summary Report

Sonus Networks submitted their SBC 5100 Session Border

Red Condor had. during. testing. Vx Technology high availability. AntiSpam,

Lab Testing Summary Report

Lab Testing Summary Report

The Greening of Services

LabTest Report. Cisco Nexus 3064

Cisco Nexus 6004 Switch Performance Validation

TECHNOLOGY BRIEF. 10 Gigabit Ethernet Technology Brief

Data Center 40GE Switch Study. Cisco Nexus 9508 DR L. 24 February 2014 Report DR140126L

Choosing the Right Solution for Strategic Deployment of Encryption

HP environmental messaging

Gigabit Managed Ethernet Switch

3Com SuperStack 3 Switch and 48-Port Stackable Switches

Gigabit Managed Ethernet Switch

Gigabit Managed Ethernet Switch

Lab Testing Summary Report

2018 NETGEAR Sustainability Report

Seamless Cloud Connectivity. for your business

PSGS-2610F L2+ Managed GbE PoE Switch

GS-1626G Web Smart+ GbE Switch

Dell Networking S6000

T H E TOLLY. No September Dell PowerConnect 3348 vs. 3Com SuperStack 3

1-Gigabit TCP Offload Engine

Raytheon s Strategic IT Energy and Resource Management Program

Dell Networking S6000

Cisco Nexus 3548 Switch Performance Validation December 2012

Energy Solutions for Buildings

HP workstations environmental performance

QuickSpecs. Models. Standard Features Server Support. HP Integrity PCI-e 2-port 10GbE Cu Adapter. HP Integrity PCI-e 2-port 10GbE LR Adapter.

Gigabit EasySmart Switches

GS1900 Series 8/10/16/24/48-port GbE Smart Managed Switch

for Power Energy and

1588v2 Performance Validation for Mobile Backhaul May Executive Summary. Case Study

Lab Test Report DR100401D. Cisco Nexus 5010 and Arista 7124S

FGS-2616X L2+ Managed GbE Fiber Switches

TOLLY. Nortel, Inc. Ethernet Routing Switch 5000 Series. Test Summary

SAE-PE QSFP-NMS

Lab Testing Summary Report

24-Port: 20 x (100/1000M) SFP + 4 x Combo (10/100/1000T or 100/1000M SFP)

Metaswitch engaged Miercom for an evaluation of the Perimeta

Security Testing Summary of Konica Minolta bizhub vcare 2.8 Device Management and Communications System and Various bizhub Products

Who says world-class high performance computing (HPC) should be reserved for large research centers? The Cray CX1 supercomputer makes HPC performance

Thinner. Greener. Better Computing.

Effective energy management services for all your needs

MRV Communications Inspiring Optical Networks for over 20 Years

CARBON FOOTPRINT MONITORING THROUGH INNOVATION

3COM OFFICECONNECT MANAGED GIGABIT POE SWITCH

GS-2610G L2+ Managed GbE Switch

Highlights. VoIP and UC Friendly Advanced L2 QoS, Economical and Flexible POE supporting 802.3af and 802.3at

Milestone Certified Solution

NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter. HP NC510F PCIe 10 Gigabit Server Adapter

MS Series: Ethernet Power Study

Energy Action Plan 2015

Selection Guide Industry-standard Servers

Deploying Gigabit Ethernet to the Desktop: Drivers and Applications

NSG50/100/200 Nebula Cloud Managed Security Gateway

EP s approach to Power & Energy efficiency in DCs & paradigms

HPE Energy Efficiency Certification Service

VMware Technology Overview. Leverage Nextiva Video Management Solution with VMware Virtualization Technology

Green IT (ICT) (Accredited by British Computer Society)

Emulex OCe11102-N and Mellanox ConnectX-3 EN on Windows Server 2008 R2

Cisco Unified Computing System Delivering on Cisco's Unified Computing Vision

TEL2813/IS2820 Security Management

2012 Innovation Awards Application

Cisco EnergyWise: Power Management Without Borders

Highlights. Fully Managed Managing multiple ipecs switches from a single intuitive graphic user interface

3COM H3C REDUNDANT POWER SYSTEMS

Server room guide helps energy managers reduce server consumption

The European Programme for Energy Efficiency in Data Centres: The Code of Conduct

Deutsche Telekom s Smart Energy Activities. Metering Billing/CRM Europe 2012 I October 2012

Network With Us Contemporary Controls

Transcription:

Lab Testing Summary Report January 2010 Report 100103 Product Category: Power Efficient Switches Vendor Tested: Products Tested: Baseline Plus Switch 2952 Key findings and conclusions: 3Com Baseline Plus Switch 2952 with 52 GbE ports consumed 28% less power than the Industry Average consumption for comparable products Energy efficient architecture uses 65nm silicon technology to lower power consumption Effective management GUI allows administration of power saving options for all ports, by schedules or usage IMC Platform supports management and network monitoring including power consumption statistics Com Enterprise Class Baseline Plus Switch 2952 with 52 GbE was evaluated by Miercom under the Certified Green Program for power consumption and energy efficiency. We analyzed the over- 3all environmental impact and business enabling green benefits that the 2952 switch offers to its customers. In hands-on-testing and analysis of 3Com Baseline Plus Switch 2952 (48 10/100/1000 Mbps auto sensing and four 1GbE SFP ports), the switch proved to afford customers a highly economical, manageable and energy efficient Layer 2 switching solution. Utilizing the latest silicon technology and energy efficient design, the 2952 Smart Switch Series leverages its green features to promote environmentally sound network practices. The 2952 switch is operational with default settings and can also be configured using a web browser GUI. The GUI has an Energy Saving option which enables port scheduling to work at variable speeds during specific times of a day as needed by the business. In addition, the switch will power down the idle ports not running any traffic resulting in additional power savings. As shown in Figure 1, 3Com Baseline Plus Switch 2952 has an annual (continued on page 3) Figure 1: 3Com Baseline Plus Switch 2952 Annual Energy Cost All Ports Loaded, Annual Use Estimate $100 $80 $90 $60 $65 $40 $20 $0 3Com 2952 Switch SUT Annual Cost Industry Average Industry Average Annual Cost Annual cost for the Baseline Plus Switch 2952 was calculated to be $65 for 52 ports as compared to the Industry Average of $90. This is a 28% cost savings for power consumption alone. See the Business Case section on page 5 for additional details and calculations.

Test Bed Diagram IP Load Generators Switch Under Test (SUT) Environmental Measurement Tools Dranetz Encore 61000 Power Analyzer Ixia 1600T and XM2 Multifunction Chassis 3Com Baseline Plus Switch 2952 52-Port Switch Miercom Industry Average Green Calculator Fluke Scope Meter Portable Heat and Power Analyzer How We Did It The 3Com Baseline Plus Switch 2952 was evaluated for environmental impact by looking at the individual components as well as its special features and capabilities. Testing focused on the power consumption and efficiency of the product. A full audit was conducted to analyze the overall product specific environmental impact. Lab testing was conducted for power consumption under load. Measurements and audit results were verified with site survey assessments. The 3Com Baseline Plus Switch 2952 was configured and tested using 48 10/100/1000 Base-T ports and 4 SFP 1GbE ports. We measured power consumption changes by scheduling the independent ports for power down and configuring them for rate changes via GUI. In addition, we measured the power consumption at idle with no traffic, no links, partial load and full load. Measuring Power Consumption: The power consumption of 3Com Baseline Plus Switch 2952 was measured with varying network and link loads that a switch would typically experience in a real-world deployment. Power consumption was measured using a Dranetz Encore 61000 Power Analyzer from Dranetz-BMI (www.dranetz-bmi.com). The SUT was loaded with traffic at various rates and packet sizes in accordance with RFC 2544 Benchmarking Methodology for Network Interconnect Development. Power consumption measurements were taken during system boot-up, idle, and with 70% and 100% load. Power consumption was measured, while running Layer 2 traffic from an XM2 and 1600T traffic generators from Ixia (www.ixiacom.com). Traffic was applied to each of the 1 GbE ports while stressing the product with the features it supports. All power measurements were taken at 110 volts and 60 Hz frequency. Frequency was also regulated at 50Hz and 60Hz to test actual power provided in other countries. In addition, power measurements were also taken for varying frame size from small to jumbo size to analyze any change in power consumption. Miercom recognizes Ixia as an industry leader in energy efficiency testing of networking equipment. Ixia s unique approach utilizes coordination of energy measurements with network traffic load allowing energy consumption to be graphed against network traffic volume. Real-world traffic is generated by Ixia s test platform and test applications, principally IxNetwork for layer 2-3 routing and switching traffic and IxLoad for layer 4-7 application traffic. Environmental Analysis: Miercom's environmental review of the 3Com Baseline Plus Switch 2952 also entailed an examination of the 3Com company-wide and product-specific environmental impact reduction efforts. Analysis includes comparisons to industry averages for competitive products that were also tested. Copyright 2010 Miercom Energy Efficient Switches Page 2

(continued from page 1) running cost of $65 under the Business Case described on page 5. This reflects a 28% savings when comparing costs for switches that are configured with 52 1GbE ports. The cost analysis is described on page 5 under Business Case. Power Efficiency Power measurements were taken with different Layer 2 frame sizes and traffic loads. The effect of the various traffic sizes on the power consumption was measured. Baseline Plus Switch 2952 was loaded with 70% and 100% traffic. As shown in Figure 2, the power consumption at idle state with all links up registered 59.27 watts. With 70% 512 byte load, the watts used increased to 59.94. At 100% load there was an increase of 1.03 watts for a total 60.3 watts. We took additional measurements for power consumption using different frame sizes and found that when using Jumbo frames (9216 bytes), the power consumption was 59.88 watts, an increase of only 0.61 from idle without traffic. We noted that an increase in the frame size caused the power consumption to decrease as shown in Figure 2. A Web based management GUI provides access to dynamic port speed throttling for the Baseline Plus Switch 2952. This feature can reduce the load on the processor, for example, a schedule can be created to change the load to a lower rate on all 52 ports in order to reduce the power consumption. See Figure 3 for more details. The 3Com Baseline Plus Switch 2952 used 30% less power than the Industry Average (IA) of similar 52 port GbE switches. At 100% load with 512-byte packets, the IA was 85.2 watts, while Baseline Plus Switch 2952 consumed 60.3 watts. At 70% load 59.9 watts was used. See Figure 5 on page 5. The total annual power consumption by Baseline Plus was calculated to be 519.67 watts compared to Industry Average of 719 watts. 3Com Baseline Plus Switch 2952 used 1.15 watts power per port as compared to Industry Average of 1.64 watts per port at full load. The Business Case described on page 5 shows that deploying 3Com baseline switches in a network can reduce energy bills by 28%. Product Efficiency The 3Com Baseline Plus Switch 2952 with 48 1GbE ports and 4 SFP fiber uplinks can provide greater media flexibility for data transport and achieve greater distance connectivity. The Switch 2952 is easily manageable via a web browser interface for configuration, monitoring and administration. Features include LACP (Link Aggregation Control Protocol) for automated device grouping, which helps to prevent traffic bottlenecks. Integration with 3Com Intelligent Management Center (IMC) Platform provides all basic tools needed to manage and monitor a network including the power consumption at each node. IMC delivers full Fault-management, Configuration, Accounting, Performance and Security) FCAPS solution and can be used to map the network topology, with indicators for connected devices and port locations. Figure 2: 3Com Baseline Plus Switch 2952 Power Profile 48 1Gbps ports, at specified frame size and load Watts 62.0 61.5 61.0 60.5 60.0 59.5 59.0 58.5 58.0 59.27 61.19 61.72 60.30 59.94 59.87 Frame Size (Bytes) Frame Size (Bytes) 60.13 59.68 64 51512 151508 929216 59.88 Idle (No Traffic) 70% Load 100 % Load The Power Profile shows the energy consumed while using different frame sizes and traffic loads. Power with all links up and without traffic was 59.27 watts. This was gradually increased as Layer 2 traffic was added to the switch. With an increase in frame size and throughput, the power consumed decreased. Copyright 2010 Miercom Energy Efficient Switches Page 3

Figure 3: Management Interface with Energy Savings Settings Using the intuitive built-in web interface, an administrator can use the Energy Saving option to modify the ports for low bit-rate or shutdown by time-of-day. Ports can easily be set to low speed or shutdown at pre-scheduled times. The 3Com Baseline Plus Switch 2952 uses 65nm silicon to improve the green capabilities of the switch with lower power consumption. Switch 2952 has an auto-idle power down mode which can also decrease energy consumption. New security features are supported including SSL to encrypt all HTTP traffic for secure access to browser based management. The switches also include automatic DoS protection. Quality of Service offerings allows traffic prioritization and classification of real time traffic into eight priority levels mapped to eight queues. The web interface GUI as shown in Figure 3 has all the ports listed to allow an administrator to schedule ports to work at low bit-rate or even power off when not in use. This is another energy saving capability in the network. Baseline Plus Switch 2952 offers a switching capacity of 104 Gbps loading the same with 100% traffic. We measured the power consumed for jumbo frame size and found it uses 25.3% less Watts/Gbps than the Industry Average as shown in Figure 4 on page 4. Business Processes 3Com strives to reduce landfill waste, by reducing the physical size of their products and simplified packaging. Paperless documentation is now available online, further reducing materials used and facilitating recycling activities. 3Com demonstrates their commitment to the environment when planning and designing 3Com facilities and operations. 3Com implements recycling and waste reduction programs, energy management systems for controlling light and heat, a global print-on-demand system for marketing and sales materials, all part of eliminating and reducing landfill waste. 3Com employs technologies that enable employees to work remotely, reducing travel and damaging emissions. IMC controls multiple devices from a central remote location and allows the administration of all devices on the network. Remote backup, mass configuration changes and other similar functions can all be performed without Figure 4: 3Com Baseline Plus Switch 2952 Power Efficiency Watts/Gbps 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 1.15 1.54 Frame Size = 9208 Bytes 3Com Baseline Plus 2952 Industry Average A comparison of the power consumption relative to performance throughput for the switch under test compared to the Industry Average (IA). The Baseline Plus Switch 2952 uses 25% less watts than the IA. Copyright 2010 Miercom Energy Efficient Switches Page 4

traveling to various locations. Carbon foot print is again being reduced. Green Innovation All 3Com products are designed with the latest silicon technology. The 3Com s Baseline Plus Switch 2952 uses 65nm technology, providing enhanced performance without increasing power usage. This has led to 31% savings from the previous generation 90nm silicon. In addition to reducing power consumption, heat generation and cooling requirements, the built-in dual speed cooling fans run at a lower speed and reduce the amount of energy that fans require. 3Com also uses texture mapping rather than printing, electroplating or bronzing to reduce materials used in product manufacturing. Recyclable materials are used whenever possible in component manufacturing. Shipping by sea rather than air is 3Com s preferred choice for global distribution of products, reducing overall impact on the environment. Affiliations and Standards As a Contributing Member of the Green Grid, 3Com is involved in efforts to standardize methods for measuring energy efficiency. Through membership, 3Com is able to vote on initiatives that compliment participation in the Watts Figure 5: 3Com Baseline Plus Switch 2952 Power Consumption 48 port switch, 512-byte frame size, at specified load 80 70 60 50 40 30 20 70.0 79.0 80.0 59.27 59.94 60.30 Idle 70% 100% Load Layer 2 2952 SFP Plus Industry Average IEEE 802.3 Ethernet working group s activities, especially its IEEE P802.3az Energy-efficient Ethernet Task Force. As an ENERGY STAR partner, 3Com is part of a global effort to help customers realize money savings and protect the environment through energy-efficient products and practices. 3Com products comply with both the European Union s RoHS and China-RoHS directives, which regulates and restricts the use of hazardous materials in the manufacturing of electrical and electronic products. Business Case Figure 1 shows an annual savings of $25 for Switch 2952 compared to the IA. The annual costs were compared to a typical switch being used with varying traffic from idle to the maximum line rate. The Annual Use Estimate (AUE) is based on a duty cycle of 12 hours per work day each week. During those 60 hours approximately 10 hours will be running at 100% load while the remaining 50 hours will run at 70% load. Weekends and the remaining 12 hours per day are considered as idle/ready for a total of 108 hours per week. To calculate the annual cost, multiply the kilowatts by total yearly hours; and multiply this result by the cost factor of 12.5 cents per kwh. Certified Green Miercom conducts environmental analysis on products using holistic view, considering power efficiency, manufacturing, and other factors which are part of the product and its lifecycle. Power consumption and power efficiency are very important metrics for comparing products and are typically all that are discussed in other organizations green reports. We believe a more comprehensive approach, which reveals true business case savings to customers for the other environmental benefits a vendor s product may afford, is a better approach. Competitive indexing with industry average is achieved by comparing measured results from products in a given class. This comparison allows a single view of the annual cost for power consumption of a product, and comparison information that will help the user understand if the evaluated product affords an overall advantage for power efficiency. Copyright 2010 Miercom Energy Efficient Switches Page 5

Miercom Certified Green The energy-saving attributes of the 3Com Baseline Plus Switch 2952 were evaluated by Miercom in accordance with the Certified Green Testing Methodology. The product met the required criteria to achieve the Miercom Certified Green Award. Based on our hands-on testing and the verified representations made by 3Com, Miercom confirms that 3Com Baseline Plus Switch 2952 is designed to provide effective and environmentally sound networking solutions. Baseline Plus Switch 2952 gives customers a highly economical, manageable and energy efficient Layer 2 switching solution. Utilizing the latest silicon technology and energy efficient design, the 2952 leverages its green features to promote environmentally sound network practices. Baseline Plus Switch 2952 350 Campus Drive Marlborough, MA 1-800-975-7682 www.3com.com About Miercom s Product Testing Services Hundreds of product-comparison analyses have been published over the years in such leading network trade periodicals as Network World, Business Communications Review - NoJitter, Communications News, xchange, Internet Telephony and other leading publications. Miercom s reputation as the leading, independent product test center is unquestioned. Miercom s private test services include competitive product analyses, as well as individual product evaluations. Miercom features comprehensive certification and test programs including: Certified Interoperable, Certified Reliable, Certified Secure and Certified Green. Products may also be evaluated under the NetWORKS As Advertised program, the industry s most thorough and trusted assessment for product usability and performance. Report 100103 reviews@miercom.com www.miercom.com Before printing, please consider electronic distribution Product names or services mentioned in this report are registered trademarks of their respective owners. Miercom makes every effort to ensure that information contained within our reports is accurate and complete, but is not liable for any errors, inaccuracies or missions. Miercom is not liable for damages arising out of or related to the information contained within this report. Consult with professional services such as Miercom Consulting for specific customer needs analysis. Copyright 2010 Miercom Energy Efficient Switches Page 6