Telecontrol and Automation Systems

Similar documents
Sturdy and Powerful ACOS 750

Modular Two-Wire Telecontrol System

IDS SAS. Station Automation System for Complex Applications

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PM572, PM573, PM582, PM583, PM585, PM590, PM591, PM592

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

PM572, PM573, PM582, PM583, PM585, PM590, PM591, PM592

General information Engineering with Programming package. Display with display

CPU 1214C. Overview. Design. The compact CPU 1214C has:

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SICAM RTUs Ready for the Future

Station Automation based on IEC 61850

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Remote Terminal Unit ER1000 APPLICATION FEATURES

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

JUMO mtron T Measuring, Control, and Automation System

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

PLC PFC200 Controller PFC200 CS 2ETH RS

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Bilfinger Mauell GmbH. smartrtu ME 4012 PA-N

Intelligent Positioning Drive GEL 6111 CANopen, PROFIBUS DP, Ethernet etc.

Automation Unit TM 1703 ACP. SICAM 1703 flexible for all applications. Answers for energy.

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

APP 700 Technical Specification

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

mark150s mark150/485s DDC controllers Summary

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

RIC PROGRAMMABLE INTELLIGENT CONTROLLER

IMIO100 IMIO105. DDC controllers. Summary

FIeldbus. Sense it! Connect it! Bus it! Solve it! /03

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Analog output 520AOD01 Data sheet

KS 108 flexible Compact PLC with touch operating screen

Supply voltage. Input current. Encoder supply. Memory

ABB 520BID01 Binary Input datasheet

LT : Suitable platforms for harsh environments

General information. Supply voltage

Sub-Station Station. Secondary Sub. Sub- Distribution. Network. Distribution Panel. Distribution. Panel

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

SIPLUS CPU 313C-2DP. Function

Product type designation. General information. Supply voltage. Input current

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Industrial Automation with PLC. LM MICRO SERIES PLC Selection Guide

QUINT-PS/ 1AC/24DC/ 5

General information. Supply voltage. Input current

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

NTX Series Product Comparison

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

ACOS 300. Reliable protection for network and constructions in medium- and high voltage

TIM 3V- IE ADVANCED. Function

VariTrans P The Problem The variety of tasks results in a large number of different devices.

Scout-S Station Controller

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

MINER-S Station Controller. Substation Automation

extending the boundaries of technology evolution of proven technology FEATURES

Technical Information Fieldgate SFG500

CPU 412H. Function. Parameterizable properties

FEATURES DESCRIPTION FEATURES

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

CM592 PROFIBUS Communication Module

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

DI572 Digital Input Module

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

DI561 Digital Input Module

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Preconfigured SCADA solution: Easy & Powerful

Transcription:

Telecontrol and Automation Systems

Telecontrol and Automation Systems IDS telemetry and automation systems are characterized by highest electro-magnetic immunity, powerful PLC-functionality and multiple data transmission possibilities. Different structures with a uniform software platform offer the possibility to build open and scaleable telemetry, automation and communication networks. Engineering can be quickly and easily done via a graphic tool. IDS telecontrol and automation units are designed for the supply and disposal industry, for industrial infrastructure applications and for transportation systems. In addition, they are used as field and station controllers in all voltage levels of electricity networks. With a broad array of products the IDS telecontrol and automation technology meets all demands. For extensive applications with complex communication structures the offers a modular, The following table shows the differences between the systems: System Construction 6 HE-rack, compact unit, compact unit modular modular Single-point typ.: 1.024/ signals 1) max. 2.048 128 2) 16 Single-point commands 1) typ.: 1.024/ 128 2) 4 Analog max. 2.048 Inputs 64 2) 4 Analog Outputs 16 2) Serial ports max. 64 max. 4 2 Networkinterfaces max. 9 max. 2 1 freely scaleable telemetry and automation unit. The modular telemetry and automation system is suitable for applications with a limited amount of information. For small sized tasks the units with its fixed data amount is the best choice. Compatibility between the product lines, and is guaranteed within the telemetry and automation systems and to the IDS HIGH-LEIT control system. All systems have the following standard component fitting: power supply module with galvanic isolation of input and system voltage for different power feeds CPU with RISC-processors type PowerPC own floating point arithmetic and high-precision quartz oscillator real time clock, watch-dog timer, buffered Flash-RAM 1), and also process double-point signals and commands 2) under consideration of combination possibilities and maximum system limitations

buffering of process information with dial-up and radio services, respectively in case of failure of communication path, in fixed time intervals or event-driven There are various applications for the automation: volume control systems, hydro power plant automation, gas controller setting and control of water treatment plants. Automatisation The systems IDS50, and have an integrated soft PLC acc. to IEC 61131-3, which provides extensive capabilities for telemetry and inter communication. In the entire communication network - also within complex, hierarchically structured telemetry networks - a direct and unrestricted access to the objects of the IEC 60870-5-101/104 standard is possible. Thus not only access to all object types and qualities, e.g. time stamp, quality attributes, is given but also the efforts for parameterization are significantly reduced. For creation of PLC programs the languages defined in IEC 61131-3 are available: LD (ladder diagram) IL (instruction list) SFC (sequential function chart) FBD (function block diagram) CP (contact plan) ST (structured text)

Communication, Engineering and Diagnosis Communication The CPU modules of all types provide as per standard already 4 () respectively 2 (IDS 650/) serial communication ports as well as one Ethernet port. Via the communication modules CC88A () and CC68A () the number of interfaces for each unit can easily be extended by 4 respectively 2 serial communication ports and one Ethernet port per module. The standard modules support the following communication protocols: IEC 60870-5-101 IEC 60870-5-103 IEC 60870-5-104 IEC 61850 (only and ) Modbus RTU Profibus DP (only ) IDS-protocol Classic telecontrol communication structures WT WT Front-end processor Modem Modem analog ISDN/GSM Interface to supervisory control system Leased line Modem Dial-up and radio / / Moreover, for a great number of proprietary protocols are available with additional communication modules including the emulation of the procedure to interface with a variety of third party systems. For the telemetry communication, for example, the protocol families AEG SEAB, Siemens SINAUT or TELEGYR TG 80x and for PLC communication Siemens 3964R protocols are supported. In total, IDS has realized more than 150 3rd party protocols. The communication within the telemetry network is done per standard with the protocol IEC 60870-5- 101/104 server and client via analog and digital leased lines as well as dial-up and radio connections. To connect stations which are difficult to reach also GSM, GPRS and UMTS data services can be used with special modems. Besides the telemetry protocols IDS telecontrol and automation systems also support various field communication protocols. Protection devices can be connected via IEC 60870-5-103 protocol, intelligent process peripheral systems via the Modbus-RTU protocol. In order to connect peripheral units directly, IDS additionally supports Profibus DP and FMS protocols. A LCD-terminal DI104 can be integrated in all systems for local display of operational data. To ensure an optimum communication, IDS systems are characterized by special telemetry functionalities: Buffering of process information for dial-up and radio services, respectively in case of communication failure in fixed time intervals or eventdriven. Realisation of multi-way communication (diversification) and use as communication node (master and sub-master unit) event-driven transmission of measured values with integrated general polling; alternatively cyclic measured value transmission event-driven transmission of status, commands and setpoints; adjustable transmission priorities

Front-end processor Firewall Interface to supervisory system network based communication structures LAN/WAN IEC 60870-5-104 Firewall Internet Firewall Leased line (optional) Mobile service provider GPRS Radio link mit GPRS Modem mit GPRS Modem Engineering and Diagnosis Configuration and parameterization of the entire IDS telemetry network can be done at superior positioned systems ( sub-master station, master station) with the SCADA system IDS HIGH-LEIT. Furthermore, the engineering tool provides extensive diagnostic functions. The telegram traffic can be monitored, recorded (tracing) and simulated. To ensure a comprehensive documentation of the system, also connection plans and test reports can be generated. The units can be commissioned either centralized via a graphic engineering tool or directly at site. The engineering tool offers various functions to make commissioning quick and easy and without special technological knowledge. IDS telecontrol stations with simple connection to the telecontrol master station can be fully set into operation with just a few mouse clicks. All necessary settings are queried in clear dialogues and sent to the unit at a touch of a button. IDS telecontrol and automation units have integrated service functions for test purposes and self-diagnosis of all modules. The functional and status check is also possible via in-built LEDs. An internal watch-dog timer with potential-free contact monitors the functionality and system voltages. In case of failure an automatic restart is done.

Series Overview The modular and freely scalable telecontrol and automation system combines compact dimensions with a robust industrial design. All components are integrated as pluggable modules into a metal housing. This installation-friendly solutions makes the a easy to configure and expandable system. The basic systems are suitable for direct installation in 19" racks and for wall mounting. has the following characteristics: basic racks for the incorporation of a power supply module, a CPU and 5, 9 or 16 pluggable communication and/or I/O modules by cascading of several racks units with up to 2.048 I/Os can be realized process connection is done at the front via pluggable screw terminals function and status indication directly on the CPU module via LED command output modules (1, 1.5 and 2-pole) provide a 1 out of n check and can be optionally equipped with field loop check The integration of all components into a metal housing provides a ready-to-use and installation friendly automation and telemetry unit in compact construction and robust industrial design. The unit is suitable for top-hat rail as well as wall mounting.

has the following special characteristic features: rack for incorporation of one power supply module, one CPU, one communication module and 4 or 8 I/O modules power supply module with different inputs and galvanic isolation of input and system voltages The compact telecontrol and automation system offers a fixed signal and interface scale. The I/O amount is designed to cover monitoring, control and automation requirements of typical small-scale plants of the water, sewage, gas and electricity industries. The solid plastic housing is space-saving and suitable for top-hat rail mounting. process connection at the module front via pluggable screw terminals function and status indication on an optional available intelligent display module via LED command output module (1, 1.5 or 2-pole) offers the following features: power supply module with galvanic isolation of input and system voltages process connection at bottom and top side via screw terminals function and status indication via LED

The IDS System technology stands for a concept which offers above all functionality and safety to the user. Universality with regard to communication and construction types with uniform software platform enable the construction of open and free scalable telecontrol, automation and communication networks. The integration of 3rd party equipment is easily possible at all levels and in all directions. The compatibility of the series, and is granted within automation and telemetry networks and towards IDS HIGH-LEIT SCADA systems. The IDS telecontrol and automation systems are designed for the utility industry, industrial infrastructure applications and transportation systems. Moreover, they are used as bay and station controllers at all voltage levels of electricity networks. IDS GmbH Nobelstraße 18 D-76275 Ettlingen Phone +49 72 43 218-0 Fax +49 72 43 218-1 00 E-Mail info@ids.de Internet www.ids.de Technical changes reserved VPM.10317.11095

Technical Data Telecontrol and Automation Systems Module type Module Module properties designation Power supply modules PS8HA Power supply 110...230 V AC/DC PS8LB Power supply 24...60 V DC Central processing module CU88A Automation and communication; 4 x RS232; 1 x Ethernet (10/100 Base TX) Communication modules CC88A Communication; 4 x RS232; 1 x Ethernet (10/100 Base-TX) CC86A Communication; 4 x RS232 OC88A Fiber optic cable; 4 x FO interfaces; 1 x Ethernet (10/100 Base-TX or 100 Base-FX) OC86A Fiber optic cable; 3 x FO interfaces EC86A Ethernet Controller; 1 x Ethernet (10/100 Base-TX) PC86A Profibus Controller (FMS/ DP); 1 x RS485 FM81A Leased-line modem; 50 Bit/s...1,200 bits/s; HD/VD DM81A Dial-up modem, analog; max. 33,600 bits/s I/O modules DI85A Digital input module, 32 inputs; 24...60 V DC; time stamp: 1 ms DI84A Digital input module, 16 inputs; 24...230 V DC; time stamp: 10 ms DI84B Digital input module, 16 inputs.; 24...230 V DC; time stamp: 1 ms DO85A Digital output module, 32 outputs; 24 60 V DC, max. 200 ma DO84A Digital output module, 16 outputs; 230 V; max. 6 A DO83B Digital output module, 8 outputs; 230 V; 8 A CO83A Command output module, High Power 8 outputs; 230 V; max. 1,000 VA CO83B Command output module, High Power 8 outputs.; 230 V; max. 2,000 VA AI83A Analog input module, 8 inputs; ±25 ma; resol.: 16 bits AI82A Analog input module, 4 inputs; ±25 ma; resol.: 16 bits AI83B Analog input module, 8 inputs; ±25 ma; resol.: 16 bits AO82A Analog output module, 4 outputs; 0...20 ma; 4...20 ma or 0...24 ma; resolution: 12 bits CI84A Counter input module, Low Frequency, 16 inputs; max. 25 Hz CI83A Counter input module, Low Frequency, 8 inputs; max. 50 Hz CI83B Counter input module, High Frequency, 8 inputs; max. 50 Hz; battery backed CI82A Counter input module, High Frequency, 4 inputs; max. 5 khz MS8AA Measuring system; 100 V; 1 A, 2 A, 5 A; synchro-check Mechanical design Ambient conditions Screening metal house for direct installation in cubicles Module rack 850A: 239 W x 266 H x 128 D mm Module rack 850B: 321 W x 266 H x 128 D mm Module rack 850C: 483 W x 266 H x 128 D mm Basic systems D/E/F/... for more than 18 communication or I/O modules by coupling several module racks Ambient temperature -20... 70 C Air humidity < 95 % (non-condensing) Insulation test acc. to IEC 60255-5 Power-frequency withstand voltage: 2.5 kv; 50 Hz; 1 min Surge voltage: 5 kv; 1.2/50 µs; 0.5 J EMC (Electromagnetic Interference resistance acc. to EN 55024:1998/IEC 61326:2002 compatibility) IEC 60870-2-1 levels 3 and 4 Emitted interference acc. to EN 55022:2000/IEC 61326:2002/IEC 60870-2-1 Class A Equipment safety acc. to IEC 61010-1 Technical changes reserved

Module type Module Module properties designation Power supply modules PS6HA Power supply 230 V AC/DC PS6HB Power supply 110 V DC PS6LA Power supply 24...60 V DC Central processing module CU68A Automation and communication; 2 x RS232; 1 x Ethernet (10/100 Base-TX) Communication modules CC68A Communication; 2 x RS232/RS485; 1 x Ethernet (10/100 Base TX) OI62A Fiber optic cable; 2 x FO interface FM61B Leased-line modem; 150...1,200 bits/s; HD/VD DM61B Dial-up modem, analog; max. 33,600 bits/s I/O modules DI64A Digital input module, 16 inputs; 24...230 V DC; time stamp 10 ms DI64B Digital input module, 16 inputs; 24...230 V DC; time stamp 1 ms DO64A Digital output module, 16 outputs; 230 V; max. 4 A IO63A Digital input/output module; 8 inp./4 outp.; 24...60 V DC; 230 V; max. 4 A CO61A Command input/output module; 8 inp.; 2 outp.; 24...230 V DC; max. 500 VA AI63A Analog input module; 8 inp.; ± 25 ma; resolution: 16 bits AO61A Analog output module; 2 outp.; 0...20 ma, 0...24 ma, 4...20 ma; resolution: 12 bits Mechanical design Ambient conditions Insulation test acc. to IEC 60255-5 Screening metal housing for installation on top-hat rail Module rack 650A: 210 W x 120 H x 110 D mm Module rack 650B: 290 W x 120 H x 110 D mm Ambient temperature -20... 70 C Air humidity <95% (non-condensing) Power-frequency withstand voltage: 2.5 kv; 50 Hz; 1 min Surge voltage : 5 kv; 1.2 / 50 µs; 0.5 J EMC (Electromagnetic Interference resistance acc. to EN 55024:1998/IEC 61326:2002 compatibility) IEC 60870-2-1 levels 3 and 4 Emitted interference acc. to EN 55022:2000/IEC 61326:2002/IEC 60870-2-1 Class A Equipment safety acc. to IEC 61010-1 Module type Power supply Central processing module Communication interfaces I/O modules Mechanical design Ambient conditions Module properties 24...60 V DC or 230 V AC Automation and communication 2 x RS232 1 x Ethernet 16 digital inputs, 24...60 V DC; time stamp: 10 ms 4 digital outputs, 24...60 V DC; max. 200 ma 4 analog inputs; ± 25 ma ma, 16-bit resolution. Robust plastic housing for installation on top-hat rail 70 W x 105 H x 115 D mm Ambient temperature -20... 70 C Air humidity <95% (non-condensing) Insulation test acc. to IEC 60255-5 Power-frequency withstand voltage: 2.5 kv; 50 Hz; 1 min Surge voltage : 5 kv; 1.2 / 50 µs; 0.5 J EMC (Electromagnetic Interference resistance acc. to EN 55024:1998/IEC 61326:2002 compatibility) IEC 60870-2-1 levels 3 and 4 Emitted interference acc. to EN 55022:2000/IEC 61326:2002/IEC 60870-2-1 Class A Equipment safety acc. to IEC 61010-1 Technical changes reserved VPM.10318.11095 IDS GmbH Nobelstraße 18 D-76275 Ettlingen Phone +49 72 43 218-0 Fax +49 72 43 218-1 00 E-Mail info@ids.de Internet www.ids.de