Din Mounted Smart LonWorks Router

Similar documents
Next Generation Intelligent Lon EIA/ANSI 709 Router Datasheet

CNSEISK 5, 8 & 16- Port Copper and Fibre Sub Miniature Ethernet 10/100 Switches

10BASE-T/ 10BASE-FL or 100BASE-TX/100BASE-FX compliant. Auto-negotiated data rate and flow control on twisted-pair ports

BACnet/IP to BACnet MS/TP Router

- for Niagara. elitedali Multidrop Connectivity Kit/AX Datasheet

SmartRouters Optionally with Bus Diagnostics RTRS RTRSD

LON-module for MULTICAL 601

LON Module for Variable Speed Drive

- for Niagara. elitedali Connectivity Kit/N4 Datasheet. Introduction

Easylon Network Components

It's not just about the building s structure, It's about the substance, Its impact on the people and the environment it shares

Easylon Interfaces. Connecting to LonWorks and CEA Networks. Interfaces + High performance network access

FEATURES DESCRIPTION MODEL 110B. Power Supply

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Smart Lighting Controls

INSTALLATION INSTRUCTIONS

PCI Interface + Manual

IntesisBox LON - KNX

Easylon For Automation with LonWorks Interfaces Connecting to LonWorks Software LonWorks Data Access Network Components From Repeater to Terminator

1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1

PG AC Modbus TCP to LonWorks Protocol Converter

LONWORKS Plug-In Software

USB Interface+ User Manual

PXR11 PXR12. System controllers DESIGO PX

controller data sheet JACE 8000 PRODUCT DEFINITION

USB Interface+ User Manual

5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

IntesisBox Modbus Server - LON

NodeBuilder 3.1 Development Tool Model 10020

MicroTech II Applied TM Rooftop Unit Controller and Self-Contained Unit Controller BACnet TM MSTP Communication Module

Cabling Installation - Procedures

6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots

Mounting and Operating Instructions EB EN. Electric Actuators with LON Interface. Type 5824 without Type 5825 with fail-safe action

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

EC-BOS-8 Multi-protocol Web Building Controller

Compact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE

EC-BOS-8 Multi-protocol Web Building Controller

Technical Datasheet clima RCM-FC 1. Product description

MicroTech II TM Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet TM Communication Module BACnet/IP

PLC - LonWorks Programmable Fieldbus Controller 16-bit CPU

MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet Communication Module MS/TP

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

HPT300 POWER CONVERT MODULE USER MANUAL

EXOcompact. Freely programmable controller

Excel 500 XCL5010 CONTROL SYSTEM

Fieldbus Extender for DeviceNet

Island bus expansion module

Technical Datasheet clima RCM-CC

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual

LX Series Remote Input/Output (I/O) Controller

RCM Room Command Module New Style

LONWORKS. TPT Twisted Pair Transceiver Module User s Guide. Revision 3. C o r p o r a t i o n C

SHEET. AI-FR Series Redundant Fibre Ring Hubs. AI-FR Series. Compatible with the baseband 2.5 Mbps ARCNET network

IQ-SBS LCU Series Installation Instructions

LonScanner TM Protocol Analyzer User's Guide

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Installation and Maintenance Manual IM 968-4

MODEL 1600 FEATURES DESCRIPTION WIRING AND INSTALLATION NETWORK DISPLAY

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description

Anybus Communicator for LonWorksLWTool

MicroTech II Applied Rooftop Unit Controller and Self-Contained Unit Controller BACnet Communication Module BACnet/IP

TAC Xenta 280 UC-01 UC-02 UC-03

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

NTC G LTE Cat M1 / NB1 Industrial IoT Serial Modem

Quick Start Installation Guide

Pyxos FT EVK User s Guide

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Content. Product Description

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Satchwell MicroNet. Building Management System MicroNet 50 Series

SG72A COMMUNICATION MODULES USER MANUAL

Acti 9 iem3000 Series Energy Meters Functions and characteristics

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

VT992 1U External Power Supply for MTCA Systems, Quad 1200 W

Manual Release 09/2002. cm-lon FOR LOGO! Communication with LOGO! with LON systems

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

MOXA TCC-120/120I User s Guide

Viessmann and Vitotronic are trademarks of Viessmann Werke GmbH & Co KG registered in the United States and other countries.

DOMOTICA ED EDIFICI INTELLIGENTI UNIVERSITA DI URBINO

EX-RC1 Remote I/O Adapter

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

Pyxos FT Network Chip 11500R

controller data sheet JACE 8000 PRODUCT DEFINITION HARDWARE SPECIFICATIONS

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

MicroTech II Chiller Unit Controller LonWorks Communication Module

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

LONMANAGER NSS-10 MODEL

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

Technical Datasheet clima BSK4-F / BSK4-F230 NK mêççìåí=çéëåêáéíáçå

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

PGR-3200 MANUAL INSULATION MONITOR

RS485 MODBUS Module 6RO

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

i.lon SmartServer Models 7210xR-4xx, , 72160, and Description Programmable

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Transcription:

Din Mounted Smart LonWorks Router Features Compact Din Rail Mounted 24V AC/DC and 230V AC powered LonMark, LNS compliant Echelon RTR10 based Optional Trend configuration available, on request Transparent media and channel support Choice of four routing algorithms allowing trade off between ease of installation and network performance Improves system reliability by physically isolating one channel from another Reduces development cost by providing easy to fit solution On Board selectable Lon network terminators save cost of purchasing external devices Unlimited number of network variables forwarded Up to 2.5ms delay through router at 10MHz operation. Reset and Service buttons provided with power LED and service LED's for both sides of the router Available with following transceivers types: 39Kb/s RS485 (data rate adjustable via Lon Network tools) 78Kb/s twisted pair Free topology transceiver (FTT 10A), LPT 10/11 network compatible 1.25Mb/s twisted pair transformer isolated transceiver (TPT/XF 1250) CE, RoHS Description The LonWorks DIN router uses RTR 10 core technology to create an intelligent Lon router fully compatible with Echelon s LNS and LonMaker network management tools. These devices can be powered from either Mains 220/240 VAC or 24 VAC. These routers can be supplied with TP/FT10 03/06/09 1 v0.9

transceivers which are also capable of being connected to LPT 10 (Link Power Transceiver) networks. Caution: Installation by qualified personnel only. Observe established engineering procedures and CNS s published data. Be careful when connecting power! For additional information regarding use of these products please, refer to CNS LonWorks Router Guide and CNS LonWorks Din Router Installation Guide. Please note that CNS supplies a complete range of Lon Network Infrastructure Products (NIP s) and Internet Lon Network Infrastructure Products (INIP s) including Physical Layer Repeaters, Lon Terminators, Lon/IP 852 & Lon/ WiFi 852 Routers please visit our web site www.control network solutions.co.uk for more information. Lon routers are used for the following reasons; Active failure elimination Extension of transmission channels in physical dimensions and number of nodes Coupling of different transmission media Enhancement of network reliability by supplying additional signals paths Logical network segmentation Logical signal filtering Signal amplification and regeneration Please note that CNS supplies a complete range of Lon Network Infrastructure Products (NIP s) and Internet Lon Network Infrastructure Products (INIP s) including Physical Layer Repeaters, Universal Terminators, Lon/IP 852 & Lon/ WiFi 852 Routers please visit our web site www.control network solutions.co.uk for more information. Specifications Mechanical Unit is suitable for fitting on DIN 46277 and DIN EN 50022 mounting rails Overall Width 105mm Overall Height 86mm Overall Depth 58mm 22/05/2009 2 v0.9

Front Panel Din Router 22/05/2009 3 v0.9

Connector Assignments Dip Switch Positions for Setting Bus Termination Warning when using LonRepeater modules with internal termination, make sure that the network is not inadvertently terminated multiple times as this will cause network communication failures. It maybe better and more cost effective overall, to use external LonTerminators such as CNS s DIN mountable LonTerminatorIII s to avoid this installation problem. Please observe the guidelines concerning the cable length and recommended cable types, published by Echelon Corporation and the LONMARK Interoperability Association. 22/05/2009 4 v0.9

LED Status Descriptions Electrical Certification CE, RoHS Reference documents for installation and network topology issues; Echelon LonWorks FTT 10A Transceiver User s Guide, 078 0198 01D Echelon LPT 11 Link Power Transceiver User s Guide, 078 0198 01A Echelon Twisted Pair Transceiver User s Guide, 078 0025 01C 22/05/2009 5 v0.9

Ordering Information CNSRTRS/A/B, where A & B represent the transceiver options. Transceiver Type options FTT10A = 1, TPT1250 = 2, RS485 = 3 Example; CNSRTRS/1/1 = Side A transceiver FTT10 to Side B transceiver FTT10 Router Contact Control Network Solutions Ltd Studio 7, Intec 2, Intec Business Park, Wade Road, BASINGSTOKE, Hampshire, RG24 8AG, England Tel: +44 (0) 1256 818700 Fax: +44 (0) 1256 812520 Email: cns@control network solutions.co.uk Web: www. control network solutions.co.uk No part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, in part or in whole, without prior permission of Control Network Solutions. We reserve the right to make changes without notice to any products herein as part of its continued product development and improvements. We do not assume any liability arising out of the application or use of any product or circuit described herein. Lon, LonWorks, LNS, RTR 10, FTT 10A are all trademarks of Echelon Corporation. 22/05/2009 6 v0.9