VS-LC101/ VS-LC102 RS-232 command set

Similar documents
Planar Simplicity Series

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A

PRE32 RS232 protocol v1.21 Tomas Andersson

Specification. For. Serial Interface DN-T645/625

Specification. for. Serial Interface DN-C635

Control Codes. Viewing control state (Get control command) Controlling (Set control command) Command. No. Command type Command Value range

Analyzing the command string for switch to input #

Application Note BDLxxxx RS232 SERIAL INTERFACE COMMUNICATION PROTOCOL (SICP V1.82)

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam UDP411 BD Player

Subject Server vs Display Protocol Using UART Report Number Author Project Version 3.00 Remarks This document is for Internal Use.

Venstar Thermostat Adapter

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam BDP100/300 BD Players

Fohhn-Net Technical Manual

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam Solo Movie 2.1 and 5.1

Custom Installation Notes: Serial programming interface for Arcam A/V processors & receivers

Russound Dual Tuners (ST2, ST2-XM, ST2-XM2, and ST2S)


Custom Installation Notes IP/Serial programming interface and IR remote control commands for the SA10/SA20 integrated amplifier

FLAT WIDE DISPLAY FWD-50PX1. PROTOCOL MANUAL (USER CONTROL ONLY) 1st Edition

Generic RS232 protocol

C628 Enhanced JPEG Module. User Manual

Logosol Joystick Node LS-731

CLOCKAUDIO. MR88 Automatic Microphone Mixer RS232 Programming Version 4.2

User Manual. Multi-display Control Module Protocol MCS. dedicated KVM switch and rackmount screen technology

EWBS Receiving Module Communication specifications

Developer Notes INSTEON Thermostat v012. Developer Notes. INSTEON Thermostat. Revision History

INSTEON Hidden Door Sensor

[DP19] DN-500CD. Serial Command Protocol Guide

Description of communication protocols of Txxxx series

Modbus/TCP is supported on some controllers. See QCI-AN028 Modbus TCP.

EX-HDU HDMI, AUDIO & USB EXTENSION

USB-SD MP3 Module Manual

The power to engage. RS-232 PROTOCOL for CTOUCH. RS 232 protocol for CTOUCH Laser Air + V3.12. CTOUCHimPD914V170913

ambient XC RS232 Control Command Specification

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

C1098 JPEG Module User Manual

Central Management Software for NVR-915 / NVR-1615 CV5-M256

User Module. Modbus TCP2RTU. Application note

Serial Interface Communication Protocol

JMY504M User's Manual

JMY505G User's Manual

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 3 Art. no.:

POWERLINC PROGRAMMING MANUAL v1.2a

Communication Protocol/ Data Sheet

$GDSWLYH0LFUR6\VWHPV

RS-232 Control of the Advantage EQ281/8, EQ282/8 and Advantage SMS200

Serial Communication Control Interface User s Manual

The RS-485 user manual for B800 series communication

DMTME Multimeters. Communication protocol. Technical specification V1.2 ABB

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC

RS 232 protocol for CTOUCH Runner, CTOUCH Leddura, CTOUCH Leddura xt,

20 Channel MP3 Sound Board. User s Manual. Model: FN-BC20

ShenZhen Top Create Electronic Co.,Ltd. Website: Tel: CJ - CAM User Manual.

The MMDVM Specification ( )

CTT MODBUS-RTU COMMUNICATION PROTOCOL TEMPERATURE MONITOR DEVICE

Micro Module Shutter. Micro Module Shutter

Blaupunkt ( DMS?? ) Page 1 of 13

1. Implemented CM11 protocol

VP 729 Command Sets. 4 command update for Geometry Diagonal Projection 5 Add error code

SwitchLinc 2-Wire Dimmer (RF Only) (2474DWH - Dev 0x01 / Sub 0x24)

Device: MOD This document Version: 1.0. Matches module version: v1. Date: 24 February Description: MP3 Audio Module

Conto D2 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION

CAN / RS485. Product Description. Technical Reference Note. Interface Adapter. Special Features

1. HOST- Connect USB flash or HDD for saving recoded video file or still image 2. DC- DC 5V power supply. 3. HDMI IN- HDMI input.

Technical Specification. Third Party Control Protocol. AV Revolution

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam T32 Tuner

FNL Modbus TCP Interface

Chapter 2 Number System

S1V3034x Series Message Protocol Specification S1V3034x S1V3S344 S1V3G340

LORD MANUAL. Wireless Sensor Networks LXRS Data Communications Protocol

SPBUS PROTOCOL SPECIFICATION

RFID MODULE Mifare Reader / Writer SL030 User Manual Version 2.4 Nov 2011 StrongLink

C6820 Enhanced JPEG Module. User Manual V2.0. Release Note: 1. Feb 8, 2007 official released v Nov 16, 2007 released V2.0

The Ensoniq EPS/EPS16+/ASR-10 Bank Format

XS S ERIES TM PMB US TM O PTION C ARD

Dell 7609WU RS232 Protocol Document

SmartWatch Eco/Eco Compact

Optris CT/ CTlaser/ CTvideo communication interface

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

Matrix Switching System User Manual. Matrix Routing Switch. HDMI 4x4 HX-44 V.2012HX44.00

Standard H.264 DVR Setup Guide

FW UPGRADE SPECIFICATION

EX-HDU HDMI, AUDIO & USB EXTENSION

Home Automation, Inc. Omni-Link. Serial Protocol Description

CE4DMID01 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION

1. Summary. 2. Module Application Instruction. 1.2.Features. 1.3.Application Specification Description

FHD492-XV and FHD552-XV

General Remote Interface Description. en General Remote Interface Description

960H H.264 DVR Setup Guide

RCP+ Commands for Advanced Integration Package Bosch Video IP. Specification

CaMate Series User s Manual

FN-BC04 MP3 Sound Module with 10W Amplifier. User s Manual

Russound Controllers. RNET Protocol & Specifications RS-232 Communication. Document version

IF96017 MODBUS COMMUNICATION PROTOCOL

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

Blue v2 INSPIRE DVR RANGE USER MANUAL

Communication Protocol Reference Manual

Project Editor 1.2 User s Guide

D-ILA Projector. DLA-Z1 Series DLA-RS4500 Series. External Command Communication Specification

OPTRIS CT/CTL communication interface

Transcription:

VS-LC101/ VS-LC102 RS-232 command set No Issue Date Description Apply Firmware 1 2015/09/14 First version. v3.1.5.28 2 2018/04/27 1. RS-232 command(control Protocol) will respond ACK 2. RC pass-through control will respond ACK/NAK v3.3.5.28 *Notice: 1. The RS-232 command list is for VS-LC101/ VS-LC102. 2. The yellow highlight means the latest update. 3. The blue highlight means the deleted item.

1 Protocol Type No. Protocol FW Version Description RC(Remote control) pass-through protocol is used for an external device 1 RC Pass-Through Protocol FW before v3.3.5.28 that want to simulate as an infrared remote controller. The operation transition with RC data field of the protocol is the same as from the infrared remote controller The CaptureVision station can be controlled from an external controller 2 Control Protocol FW after v3.3.5.28(incl.) through a serial RS-232 connection. Control protocol is used for the communication between the CaptureVision station and controller. 2 Configuration Transmit Method: Asynchronous Interface Half Duplex Serial Communication Baud rate: 9600 Start bit: 1 Bit Flow control: none Data length: 8 Bit Stop bit: 1 Bit

3 Hardware

4 Connection

5 RC Pass-Through Protocol 5.1 Communication 5.1.1 PC or Controller send a command with 4Byte to CaptureVision Station 5.1.2 CaptureVision Statio has Return command (FW after v3.3.5.28(incl.) will send ACK) 5.2 Command (Controller send to CaptureVision Satation) Name Byte count Hex Description Header (Start Command) 1 0x36 Remote control pass-through protocol RC Lendth 1 0x01 Length is a byte counter in RC data field RC code 1 Please refer to RC code tab for more information End 1 0x0D End code of command 5.3 Response (CaptureVision to Controller) Name Byte count Hex Description ACK/NAK 1 ACK: 0x06 NAK: 0x15 ACK: The command is accepted in the CaptureVision Station. NAK: The command is not accepted in the CaptureVision Station. End 1 0x0D End code of response

6 RC code Funtion RC Code (Hex) Remark Power off 0x0a 1. Power Off Lumens CaptureVision 2. This command can't power on Lumens CaptureVision) Trigger ouput resolution auto scan 0x25 This command acts as the [Resolution] function on IR Remote Controller which is to trigger Output resolution auto scan and find the best resolution for the display. A 0x22 IR remote controller "A" key B 0x3f IR remote controller "B" key C 0x20 IR remote controller "C" key D 0x24 IR remote controller "D" key Number 0 Record layout 1 / Number 1 Record layout 2 / Number 2 Record layout 3 / Number 3 Record layout 4 / Number 4 Record layout 5 / Number 5 0x28 0x2a 0x2b 0x2c 0x36 0x1d Normal: NA IP Camera image enlarged: Call CameraPreset 0 Normal: Switch to Record layout 1 P Camera image enlarged: Call CameraPreset 1 Normal: Switch to Record layout 2 P Camera image enlarged: Call CameraPreset 2 Normal: Switch to Record layout 3 P Camera image enlarged: Call CameraPreset 3 Normal: Switch to Record layout 4 P Camera image enlarged: Call CameraPreset 4 Normal: Switch to Record layout 5 P Camera image enlarged: Call CameraPreset 5 Record layout 6 / Number 6 0x34 Normal: Switch to Record layout 6

Funtion RC Code (Hex) Remark P Camera image enlarged: Call CameraPreset 6 Record layout 7 / Number 7 Record layout 8 / Number 8 0x3c 0x0b Normal: Switch to Record layout 7 IP Camera image enlarged: Call CameraPreset 7 Normal: Switch to Record layout 8 P Camera image enlarged: Call CameraPreset 8 Record layout 9 / Number 9 0x0f Normal: Switch to Record layout 9 P Camera image enlarged: Call CameraPreset 9 Record Start 0x1a Snapshot 0x18 Menu 0x19 Exit 0x0c Call Preview Layout Windows 0x00 Up 0x08 Left 0x07 Right 0x06 Down 0x09 OK 0x1c Back 0x0c Aspect 0x0e Aspect function on the IR remote control Volume Up 0x03 Volume Down 0x02 Channel Up 0x1b Channel Down 0x0d

Funtion RC Code (Hex) Remark Mute 0x4c Information 0x11 Call record Layout Window 0x16 Play 0x14 Pause 0x17 Record Stop / Playback Stop 0x1f Last Course 0x13 Next Course 0x15 Last knowledge mark 0x10 Next knowledge mark 0x12 Save Camera Preset 0x30 IP Camera image enlarged: Save Camera Preset Camera Zoom + 0x3e Camera Zoom - 0x2e Display Layout 1 0x40 Switch to Display Layout 1 Display Layout 2 0x41 Switch to Display Layout 2 Display Layout 3 0x42 Switch to Display Layout 3 Display Layout 4 0x43 Switch to Display Layout 4 Display Layout 5 0x44 Switch to Display Layout 5 Display Layout 6 0x45 Switch to Display Layout 6 Display Layout 7 0x46 Switch to Display Layout 7 Display Layout 8 0x47 Switch to Display Layout 8 Display Layout 9 0x48 Switch to Display Layout 9

7 Control Protocol 7.1 Communication 7.1.1 PC or Controller send a command with Header 0x55 to CaptureVision Station. 7.1.2 CaptureVision Station has Return command 7.1.3 FW after v3.3.5.28(incl.) supports Control Protocol 7.2 Command (Controller send to CaptureVision Satation) Name Byte count Hex Description Header (Start Command) 1 0x55 Header 0x36 can be recognized as Control Protocol Ectender Header 1 0xff reserved for future use. Lendth 1 0x0n Length is a byte counter from address to checksum field. Counter = address 1 byte+action 1 byte+command 2 bytes+parameter 1 byte+checksum 1 byte Total length = 6 bytes Address 1 0x01 Identification of device. Range is 0x01 ~ 0xff.(0 is reserved) *Address is reserved for future use. Don t care Action 1 Pls refer to 2.2 Action Description Pls refer to 2.2 Action Description Command 2 Pls refer to 2.1 Command Parameters n Follow the command. Checksum 1 End 1 0x0d End code of command Checksum is a byte sum.add the data that from length to parameters field as unsigned binary numbers, discarding any overflow bits.

7.3 Action Description Command / Response Command Get 0x67 Command Set 0x73 Response ACK 0x06 Name Hex Description Query operation for the CaptureVision station. Please refer to "Action Get" Tab Set operation for the CaptureVision station. Please refer to "Action Set" Tab When the CaptureVision station receives the protocol data correctly and executes the correspond command successfully. It replaces the action field with ACK in the received protocol format and return to controller. Response NAK 0x15 When the CaptureVision station receives the protocol data correctly but there are something wrong while the CaptureVision station executes the correspond command. It replaces the action field with NAK in the received protocol format and return to controller. 7.4 Response (CaptureVision Station response to Controller) 7.4.1 If the Hex and format of the command are correct, it will reply the ACK or NAK with original format. 7.4.2 If the format is not recognized or the command is incorrect(e.g. wrong Checksum), the Response will be 0x15 0x0D

8 Action Set 8.1 Set Action Command List Command Power PW 0x50 0x57 Power control Record RC 0x52 0x43 Record Pause record PS 0x50 0x53 Pause record Stop record SP 0x53 0x50 Stop record Record Layout LO 0x4c 0x4f Record Layout control Display Layout DP 0x44 0x50 Display Layout control Audio Volume AV 0x41 0x56 Audio volume control Audio Mute AM 0x41 0x4d Autdio mue control 8.2 Power Command PW 0x50 0x57 Parameter 0 0x30 8.3 Record Command RC 0x52 0x43 Start record process Parameter No need Parameter 8.4 Pause Command PS 0x50 0x53 Pause record process Parameter No need Parameter Power off No Power on command due to the hardware limitation.

8.5 Stop Record Command SP 0x53 0x50 Stop record process Parameter No need Parameter 8.6 Record Layout Command LO 0x4c 0x4f Set Record Layout ID Parameter 0x01~0x09 Record Layout ID 8.7 Display Layout Command DP 0x44 0x50 Set Display Layout ID Parameter 0x01~0x09 Display Layout ID *Display command is not supported with display/record layout synchronization enabled 8.8 Audio Volume Command code AV 0x41 0x56 Set audio volume Parameter 1 I 0x49 Set input volume O 0x4f Set output volume 1 0x31 Input: HDMI1; Output: Line out/hdmi out Parameter 2 2 0x32 Input: HDMI2; Output: None 3 x033 Input: JACK1(Line In 1); Output: None 4 0x34 Input: JACK2 (Line In 2); Output: None Parameter 3 0x00 ~0x7d Audio volume(0~50)

8.9 Audio Mute Command code AM 0x41 0x4d Set audio mute / unmute I 0x49 Set input volume Parameter 1 O 0x4f Set output volume 1 0x31 Input: HDMI1; Output: Line out/hdmi out 2 0x32 Input: HDMI2; Output: None Parameter 2 3 x033 Input: JACK1 (Line In 1); Output: None 4 0x34 Input: JACK2; Output: None 0 0x30 Audio unmute Parameter 3 1 0x31 Audio mute

9 Action Get 9.1 Get Action Command List Command Status ST 0x53 0x54 System status Record Layout LO 0x4c 0x4f Record Layout Display Layout DP 0x44 0x50 Display Layout Audio Volume AV 0x41 0x56 Audio volume 9.2 Status Command ST 0x53 0x54 Get system status Response Parameter 0 0x30 Uninitialize 1 0x31 Ready 2 0x32 Stopped 3 0x33 Streaming 4 0x34 Paused 5 0x35 Waiting (stay in Waiting state while web administrator and director login) 9.3 Record Layout Command LO 0x4c 0x4f Set Record Layout ID Parameter 0x01~0x09 Record Layout ID 9.4 Display Layout Command DP 0x44 0x50 Set Display Layout ID Parameter 0x01~0x09 Display Layout ID *Display command is not supported with display/record layout synchronization enabled

9.5 Audio Volume Command code AV 0x41 0x56 Get audio volume Command/Respons I 0x49 Get input volume Parameter 1 O 0x4f Get output volume 1 0x31 Input: HDMI1; Output: Line out/hdmi out Command/Respons 2 0x32 Input: HDMI2; Output: None Parameter 2 3 x033 Input: JACK1 (Line In 1); Output: None 4 0x34 Input: JACK2 (Line In 2);; Output: None Respons Parameter 3 0x00 ~0x7d Audio volume(0~50)

10 Control Example 10.1 Start Record Header Extended Length Address Action Header Command Parameters Checksum End Send - Record Start 0x55 0xff 0x05 0x01 0x73 0x52 0x43 0x0e 0x0d Response - Success (ACK) 0x55 0xff 0x05 0x01 0x06 0x52 0x43 0xa1 0x0d Response - Failed (NAK) 0x55 0xff 0x05 0x01 0x15 0x52 0x43 0xb0 0x0d 10.2 Set Record Layout ID 1 Header Extended Length Address Action Command Parameters Checksum End Header Send - Set Record Layout ID 1 0x55 0xff 0x06 0x01 0x73 0x4c 0x4f 0x01 0x16 0x0d Response - Success (ACK) 0x55 0xff 0x06 0x01 0x06 0x4c 0x4f 0x01 0xa9 0x0d Response - Failed (NAK) 0x55 0xff 0x06 0x01 0x15 0x4c 0x4f 0x01 0cb8 0x0d 10.3 Get System status of CaptureVision Station Header Extended Length Address Action Header Command Parameters Checksum End Send - Get System Status 0x55 0xff 0x05 0x01 0x67 0x53 0x54 0x14 0x0d Response - ACK, System is ready 0x55 0xff 0x06 0x01 0x06 0x53 0x54 0x31 0xe5 0x0d Response - Failed (NAK) 0x55 0xff 0x05 0x01 0x15 0x53 0x54 0xc2 0x0d 10.4 Get Record Layout ID of CaptureVision Station Header Extended Length Address Action Header Command Parameters Checksum End Send - Record Layout ID 0x55 0xff 0x05 0x01 0x67 0x4c 0x4f 0x08 0x0d Response - ACK, Record Layout ID 0x55 0xff 0x06 0x01 0x06 0x4c 0x4f 0x01 0xa9 0x0d

is 1 Response - Failed (NAK) 0x55 0xff 0x05 0x01 0x15 0x4c 0x4f 0xb6 0x0d 10.5 Set Audio Line In 1 Mute Header Extended Header Send - Set Audio Line In 1 Mute 0x55 0xff 0x08 0x01 0x73 0x41 0x4d Response - Success (ACK) 0x55 0xff 0x08 0x01 0x06 0x41 0x4d Response - Failed (NAK) 0x55 0xff 0x08 0x01 0x15 0x41 0x4d Length Address Action Command Parameters Checksum End 0x49 0x31 0x49 0x31 0x49 0x31 x033 x033 x033 0xb7 0x4a 0c59 0x0d 0x0d 0x0d