Connecting UniOP to Moeller Easy800

Similar documents
Connecting UniOP to Fatek Controllers with Facon Protocol

Connecting UniOP to Omron PLCs with the FINS Protocol

Connecting UniOP to Unidrive SP with Modbus CMP Protocol

Connecting UniOP as a Modbus Slave

Connecting UniOP to CoDeSys Controllers via Ethernet

Connecting UniOP as Modbus/TCP Server

Connecting UniOP Using Generic Modbus RTU

Mitsubishi FX Ethernet Driver for JMobile

Profibus DP Driver for JMobile

Connecting UniOP to Galil/Yaskawa controllers

Connecting UniOP to Beckhoff ADS Ethernet

Modbus TCP Server Driver for JMobile

ABB Modbus RTU Driver for JMobile

Panasonic FP Serial Driver for JMobile

CANopen HMI Communication Driver for JMobile

Control Techniques Unidrive - Modbus CMP Ethernet Driver for JMobile

ROC Plus Communication Driver for JMobile

Getting started with UniOP and CoDeSys integrated controller

Omron FINS Ethernet Driver for JMobile

Updating Systems Components in UniOP Series 400 Products

Connecting UniOP to Datalogic Barcode Readers

Getting started with JMobile Suite

The UniDataExchanger is a tool that allows an easier handling of the file transfer to and from UniOP operator panels. Contents

CODESYS V2.3 Ethernet Driver for JMobile

Mitsubishi FX Driver for JMobile

Contents 1. Introduction

Newsletter. Communicate and Stay in Control. In This Issue

Ethernet Connectivity for UniOP

CODESYS V3 Ethernet Driver for JMobile

Connecting UniOP to Modbus/TCP

Modbus TCP Driver for JMobile

Connecting UniOP to Simatic S7 Profibus

UniOP Command Summary

Simatic S7 Ethernet driver for JMobile

CREATING PANEL APPLICATIONS

Reliance. Johnson Controls communication driver version 1.5.4

Update Service for EASY-SOFT

Pass-Through Function

Analog Devices Driver Kepware, Inc.

Using UniOP HMI panels with Galil controllers

ALLEN-BRADLEY MICROLOGIX / SLC500 & EASON 2000 FAMILY

KNX TP/IP Communication Driver for JMobile

Omron Toolbus Driver Help Kepware Technologies

Lufkin Modbus Serial Driver Help Kepware Technologies

Version 2.4

Cutler-Hammer ELC Serial Driver Help Kepware Technologies

Mettler Toledo Serial Driver Help Kepware Technologies

DEB Setup Video. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

17 Configuring a BM85 In this chapter

Things to Try If You Have Problems

Yokogawa HR Driver PTC Inc. All Rights Reserved.

Fuji Flex Driver Help Kepware Technologies

Getting Started with UniOP B Series Panels

Modbus ASCII Serial Device Driver Help 2009 Kepware Technologies

Connecting UniOP to Profibus DP TI

Application Note EXOR UniOP etop HMI and Designer

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

CDN Series Displays with Profibus-DP ELEN UNI-TXT (ND) protocol PARAMETRIZATION OF PROFIBUS-DP COMMUNICATION INTERFACE

MultiPort USB User Manual

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

Mitsubishi Serial Driver Help Kepware Technologies

List of Technical Notes

Mitsubishi FX Net Driver PTC Inc. All Rights Reserved.

GEM80 & ewon Setup Quick Guide

Contrex M-Series Driver Help Kepware Technologies

Leica LP C (Laser Printer for Cassettes) System Requirement & Specifications

Contents. IDEC Communication Driver. Driver for Serial communication with Devices using the IDEC MicroSmart Communication Protocol INTRODUCTION...

TOSLINE-S20/S20LP. S20 Loader (for Windows) User's Manual

Allen-Bradley Micro800 Series

Modbus RTU/TCP Installation and Programming Guide PC3400 Particle Counter

MODBUS Protocol for MiCOM P30 Series

AutomationDirect Application Note Connecting an EZ-Touch panel to a Entivity (Think & Do) Studio/Live WinPLC

TECHNICAL NOTE TNOI35

UniOP epad03 and epad04

Philips P8/PC20 Driver PTC Inc. All Rights Reserved.

Connecting UniOP to Simatic S7 MPI

Connecting UniOP to K-M Profibus DP

UniOP CP01R-04, CP05R-04 and CP01F-02

NMEA 0183 driver for JMobile

Mettler Toledo Driver PTC Inc. All Rights Reserved.

SIMATIC S7 MPI Direct Driver

OPERATOR INTERFACE PRODUCTS APPLICATION NOTE

Fisher ROC Serial Driver Help Kepware Technologies

Control with UniOP. Tech-note PN# tn137-2.doc - 29/07/ Ver Contents

JMobile Suite User Manual

Modbus Remote Communication Protocol for REM 54_. Technical Description

Error Messages

Title: Can I use Ethernet to read and write values to my HMI?

UniOP with Siemens S5 PLC's using 3964R

INTRODUCTION... 2 GENERAL INFORMATION... 3 DEVICE CHARACTERISTICS... 3 LINK CHARACTERISTICS... 3 DRIVER CHARACTERISTICS... 4 CONFORMANCE TESTING...

Control Characters used in DirectNET

Yaskawa Electric MP900 Series Driver

Modbus Unsolicited Serial Driver PTC Inc. All Rights Reserved.

Data Logger Soft Ver 3.0a. Operating Manual

CTI 2573-MOD and CTI 2573-TCM2 SERIAL DEVICE INTERFACE ADAPTER INSTALLATION AND OPERATION GUIDE Version 2.4

Citect for Windows Driver Specification Extract

Designer Modem Communication US Robotics Sportster Modems

Schneider Electric TSX07/37/57 Series Unitelway Driver

Yokogawa YS100 Driver PTC Inc. All Rights Reserved.

D0 DCM Module Setup Direct

Transcription:

Connecting UniOP to Moeller Easy800 This Technical Note contains all the information required to connect the UniOP panels to a Moeller Easy800 controller. Sitek S.p.A. Tn189 Ver. 1.01

Copyright 2008 Sitek S.p.A. Verona, Italy Subject to change without notice The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided as is without warranty of any kind. Third-party brands and names are the property of their respective owners. www.uniop.com Connecting UniOP to Moeller Easy800 2

Contents 1 Introduction...4 2 Setting-up the Communication with Designer...5 3 Data Field Properties...6 3.1 HW - 7 Day Time Switch and HY - Year Time Switch...6 Appendix A. - Communication Status Codes...9 Appendix B. Technical Data and Connection Information...10 Connecting UniOP to Moeller Easy800 3

1 Introduction To create a Designer project for Moeller Easy800, select the driver Moeller easy800 from the list of available communication drivers in the Select Controller dialog box. The Moeller Easy800 driver is associated to the Designer file D32uplc193.dll. Note: In case the Moeller Easy 800 is not shown in the list, make sure that the file D32uplc193.dll is present in the Designer folder and then press the Refresh button. Starting from the version 5.07 4.07 the Moeller Easy 800 communication driver supports also access to HW - 7 Day Time switch and HY - Year Time switch. Connecting UniOP to Moeller Easy800 4

2 Setting-up the Communication with Designer Communication parameters for serial communication can be adjusted by clicking the PLC Comm... button. The default communication parameters are set to 19200, N, 8, 1. Figure 1 Controller Setup Dialog Box Access Multiple PLC s Slave ID The protocol allows the connection of multiple controllers to one operator panel. To set-up multiple connections, check Access Multiple PLC s checkbox and enter Slave ID Address for all controllers. Slave ID is the node of the PLC and allows the protocol to reads variable in a sub-network. Note that if Stand alone mode is set in controller the Slave ID is 0 Figure 2 - EASY SOFT Connecting UniOP to Moeller Easy800 5

3 Data Field Properties The Data Field Properties dialog box is shown in Figure 3 below. The Object combo box contains all the objects in the controller s memory available for use with the HMI panel. Figure 3 - Data Field Properties Dialog Box 3.1 HW - 7 Day Time Switch and HY - Year Time Switch Note: Version 5.07 4.07 or higher of the communication driver is required to access the controller data described in this chapter. The Data Field Properties dialog box is shown in Figure 3 below. Select 7 Day Switch FB HW or Year Time switch FB HY. The FB Field combo box contains all the objects in the controller s memory available for use with the HMI panel. Connecting UniOP to Moeller Easy800 6

Figure 4 - Data Field Properties Dialog Box related to 7 Day Switch FB HW Figure 5 - Data Field Properties Dialog Box related to Year Time Switch HY The access to the Channels depends on the configuration stored in the controller. The HMI panel cannot access to Channels that have not been defined in the controller memory. A Write operation targeting a Channel not defined in the controller memory will not be acknowledged by the controller itself and HMI will report a communication error code 04 in System Menu. Connecting UniOP to Moeller Easy800 7

Figure 6 - HW 7 Day Switch Figure 7 HY Year Time switch Connecting UniOP to Moeller Easy800 8

Appendix A. - Communication Status Codes The System Menu shows the current communication status of the panel. A message and a numeric error code report the communication status. The message describes the current communication status. The number shows the code of the current communication error or, if the communication is correct, the code of the last error encountered. When the error code 0 is shown, it means there have been no communication errors since this system startup. Code Description Notes 00 No error There are no communication errors and there have been no errors since start-up. 04 Response error PLC s frame is illegally formed, or PLC returned a NAK response. 05 Timeout error Indicates a Time Out in communication. The communication line has been broken or the modem has had a power fail. 06 Reception buffer overrun UniOP has received a frame whose length exceeds UniOP s reception buffer size. 07 Internal failure This should never happen. It indicates a hardware problem or software low-level problem. 11 Line error Indicates that communication parameters settings are not matching on UniOP s side and modem s side. 12 Checksum error Indicates that the checksum received in PLC s response frame does not match checksum calculated from received data. Connecting UniOP to Moeller Easy800 9

Appendix B. Technical Data and Connection Information Default transmission parameters are set as follows: Transmission speed: 19200 Start bits: 1 Data length: 8 Parity: no Stop bits: 1 Flow Control: none When operating a PLC network, the HMI panel is connected to only one PLC using a RS-232 link. All other PLCs in the network are daisy-chained using the EasyNet network. Please, refer to the manufacturer s documentation for details on the operation of the EasyNet network. Connecting UniOP to Moeller Easy800 10