INSTALLATION INSTRUCTIONS

Similar documents
Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

QUICK START. Installation & Programming Guide

hubbell-automation.com

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

SAVE THESE INSTRUCTIONS

MAXIMA + Series ROTARY LEVEL CONTROL

ORB TM 4-20 ma Input Box Installation & Operation Manual

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

SAVE THESE INSTRUCTIONS

MAXIMA+ Series Rotary Level Indicator

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ETC Installation Guide

Specifications, Installation, and Operating Instructions

Dual Relay Luminaire Control Module Wiring and installation manual Light is OSRAM

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Temperature. Power requirements. Weight. Dimensions

CMSA-100 Manual. Cinema Media Server Automation

SNAP Lighting Control Panel

Model DMX8DIM Installation and Operations Manual

OZONE SWITCH Model OS-6. OS-6 Features

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

SECTION DISCONNECT SWITCHES

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

USER GUIDE. Stand-Alone Version

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

ICS Entrance Management Sign Installation Guide. Version 1.0

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Quick Start Guide TS 870 ATS

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

4 Channel Contact Closure DIN Fiber Link System

TCNM-ACBB1 Installation Manual

8 Channel Contact Closure DIN Fiber Link System

6222 Two Door Module Technical Operations Manual

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Documentation Supplement for Marine Smart-UPS SRT5KRMXLIM, SRT6KRMXLIM External Battery Pack SRT192RMBPM

PowerLogic High Density Metering System 1-Meter Enclosure

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

IMPORTANT SAFETY INSTRUCTIONS

Installation, Operation and Maintenance Manual

ZC Series Zone Monitoring Controllers

Model HM-535 Power Supply Installation and Service Instructions

PV Rapid Shutdown device

Installation Instructions

Unison Echo Room Controller

Single Phase Systems-North American PC125/PC420 Series

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

DTMF-4HC. DTMF decoder board with four high current relays. Copyright 2004 Intuitive Circuits, LLC

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

Satellite INSTALLATION GUIDE

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Multi Unit Enclosed Meter

Installation Notes TII Model 341 Protector

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

M215 (M215-60) Safety

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

M215-Z Safety Information (M LL-IG-ZC)

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

LC8 CONTROLLER BOARD INSTALLATION AND MAINTENANCE MANUAL (IMM) p/n 52280T rev 11/08/05

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

Thermometer / Barometer System

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

TC-9102 Series Surface Mount Temperature Controllers

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide

Quick Start Guide TS A

NCH-1000 (Multiple Breaker Types) Installation Instructions

SAVE THESE INSTRUCTIONS

P216 Series Condenser Fan Speed Controller

Installation Instructions & User Manual

M250 (M LL) Safety

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Instruction Sheet WPC 2000 Option 1

Universal Safety Photo Eye UL MONITORED DEVICE

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Model 7705 Control Module

Model 305e OEM CO 2 concentration sensor

Resolver to Digital Expansion Board

ASCO 920 Remote Control (RC) Switches

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

Distributed Power Series

Transcription:

LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation. The mounting location should be selected and prepared based on the application. All electrical wiring and mounting hardware (i.e. electrical mounting box, conduit, etc.) should be prepared with consideration of the requirements outlined in the wiring and mounting diagrams below. These instructions include information as follows: Description Product Configurations Enclosure Mounting Installing Individual Relay Cards Connecting Panel Power Connecting Lighting Loads Connecting Low Voltage Inputs Operating the Panel Troubleshooting Panel Specifications Panel Load Schedule Form PRECAUTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION - RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn off power at the circuit breaker before installing or servicing unit. Never wire energized electrical components. NOTICE: For installation by a licensed electrician in accordance with National and/or local Electrical Codes and the following instructions. CAUTION: USE COPPER CONDUCTOR ONLY. Be sure to read and understand all instructions before installing or servicing unit For Indoor use only. Do not use outdoors. Do not mount near gas or electric heaters. Disconnect switch or a circuit breaker must be provided and marked as the disconnecting device. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Confirm that device ratings are suitable for application prior to installation. No user serviceable parts contained inside unit. Refer all service related questions to the factory. All servicing shall be performed by qualified service personnel. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. Use only approved materials and components (i.e. twist on connectors, electrical box, etc.) as appropriate for installation. NOTICE: Do not install if product appears to be damaged. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this equipment for other than intended use. SAVE THESE INSTRUCTIONS! 9601 Dessau Road, Building One Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215 www.hubbell-automation.com 3301B 11.13.2015

DESCRIPTION The CX Panel is shipped in one package. Panels are configured with all 16 or 24 relays of the same type installed or with space only for relays to be installed in the field. The relays are mounted with lighting circuit terminals in the high voltage area. The low voltage control inputs are located in the low voltage area of the panel. The following information describes the CX 16 and 24 relay panel installation. For programming information, refer to the CX Panel Quick Start Guide provided as a separate document with the Panel. PRODUCT CONFIGURATION Relay Model CX Relay Spaces Input Voltage Housing Relay Quantity Relay Type Options 16 16 Relay Spaces 24 24 Relay Spaces 2 120-208-220-277VAC 3 347VAC S Surface NEMA 1 00 No relays 16 16 Relays Installed 24 24 Relays Installed 2N 20A, 1P, N/O Elect Held 3L 30A, 1P, Latching TN 20A, 2P, N/O Elect Held TC 20A, 2P, N/C Elect Held SP Space Only M Master S Secondary Example: CX162S162NM - CX 16 Relay Panel, 120-277VAC universal input, with 16 20A/1P N/O Electrically Held Relays installed in NEMA 1 Surface Mount Master Panel. Panels are available fully populated with a single relay type or with SP option (Space Only) to allow for field installation of individual relays. This is the methodology to provide for panels with a mix of more than one type of relay. Relays can be ordered separately as follows: Relay Model Relay Type CXR 2N 20A, 1P, NO, Elect Held 120/277VAC 3L 30A, 1P, Latching, 120/277/20A 347VAC TN 20A, 2P, NO Elect Held, 208/240/480VAC TC 20A, 2P, NC Elect Held, 208/240/480VAC ENCLOSURE MOUNTING Typically the CX panel is installed near the circuit breaker panel or in the ceiling of the room containing the lighting circuits to be controlled. Select an appropriate location that meets the environmental conditions listed in the specification section of this document. The panel interior is divided into high voltage and low voltage areas as shown in Figure 1 on page 3. Select an appropriate location for incoming line voltage panel power, branch circuits to be controlled and low voltage input wiring. The housing is supplied with conduit knock-outs labeled to indicate line or low voltage wiring use. All terminations within the panel enclosure require installation by a licensed electrician in accordance with National and/or local Electrical Codes. Page 2

FIGURE 1- CX PANEL INTERIOR Locate the enclosure on the mounting surface and use a level to ensure that it is properly oriented and aligned. Secure the enclosure to the mounting surface with hardware as appropriate for the application using the three keyed mounting holes located near the top corners and in the center bottom of the enclosure as shown below in Figure 2. FIGURE 2 - ENCLOSURE MOUNTING HOLES Page 3

INSTALLING INDIVIDUAL RELAY CARDS Relay Panels are most commonly shipped with all relay cards installed. If the project requires different types of relays installed in the same panel then the relays are supplied separately and they will require field installation. In this application reference the applicable Relay Installation Instructions supplied with the individual Relay Cards on how to install relays. Caution: ALWAYS remove supply power to the Panel control Transformer prior to making any connections between relay boards and panel processor board. Failure to do so may result in personnel injury, damage to the panel, and void its warranty CONNECTING PANEL POWER The panel is designed to operate on 120, 208, 240, or 277VAC for input voltage 2 designator or 347VAC for input voltage 3 designator. Panel input power is supplied to the power supply located in the upper center of the panel as shown in Figure 1 on page 3. With the power turned off, route the dedicated panel power supply leads to the transformer and connect them to the appropriate system voltage specific leads. Connect the power supply ground lead to the panel chassis grounding lug. A label indicating this ground lug is located adjacent to the connection location. Caution: When power is applied to the transformer, the unused transformer leads become electrified. Cap unused transformer leads with wire nuts to prevent electrical shorting. CONNECTING LIGHTING LOADS With the power turned off, route the lighting system line and load leads through the high voltage area of the panel shown in Figure 1 on page 3. Connect line and load leads for each lighting load to the output terminals of the appropriate relay as delineated in the project plans and/or Panel Load Schedule. Notice: As a general rule, the panel is shipped with relays installed and electrically connected at their input control side. If, however, relays must be installed, reference the applicable Relay Installation Instructions supplied with the individual Relay Cards on how to install relays. Caution: Prior to making any connections to the relay outputs, verify that none of the loads are shorted. Failure to do so may result in personnel injury, damage to the panel, and void its warranty Notice: If no Panel Load Schedule exists, use the Panel Load Schedule Form supplied in the clear plastic pocket inside the Panel Door to record the lighting circuit relay assignments while connecting the relays CONNECTING LOW VOLTAGE INPUTS Bring the low voltage wiring for the contact inputs in through the knockouts in the low voltage wiring area where indicated in Figure 1 on page 3. The CX 4 Relay Panel supports six inputs and the CX 8 Relay Panel supports 12 inputs. Inputs are software configurable through programming to support momentary switches, maintained switches (latching), motion sensors, or photocells. Each Relay Card includes one low voltage input. The panel mother board includes 2 Auxiliary Inputs for the CX 4 Relay Panel and 4 Auxiliary Inputs for the CX 8 Relay Panel. These inputs may be connected prior to programming. Inputs may be connected to any terminal location regardless of final control programming. Connect contact closure input devices to the input terminals using 18 AWG wire. Notice: Use the Panel Load Schedule Form supplied in the clear plastic pocket inside the Panel Door to record the low voltage input types while making connections. Page 4

Low Voltage Control Diagrams shown in Figure 3 below are for use with Hubbell ControlsInput Devices ONLY. Diagrams may not apply to input devices from other manufacturers. FIGURE 3 - LOW VOLTAGE INPUT WIRING DIAGRAMS OPERATING THE PANEL The User Interface control ribbon cable is supplied connected between the User Interface Ribbon Cable Connector on the Mother Board and the User Interface Module that is attached to the panel door. The red indicator in the cable should align with the Pin 1designation. The green ground jumper is supplied connected between the panel door and the panel housing ground lug, labeled GND. Provide control power to the panel and restore power to the lighting circuits at the source circuit breakers. The panel will take a few moments to initialize during which time the User Interface screen on the front of the panel door will initiate and display the clock, date, and time zone un-programmed factory defaults. Inside the panel the Mother board power status LED will show continuous green. The Relay board status LED will turn on green for approximately 2 seconds and then go off. Push, but do not hold the Relay Manual Control button on each relay card to operate each relay to test functionality. The Relay State Status LED will turn on red when the relay is energized and be off when the relay is unenergized. The panel is now fully functional and ready to control the lighting loads. FIGURE 4 - PANEL START-UP CONTROLS Page 5

TROUBLESHOOTING A blinking green Relay board status LED indicates that communication has not been properly established for this card. Contact Hubbell ControlsTechnical Service at (800) 888-8006 for assistance and replacement as required. A complete Troubleshooting Guide is contained in the CX Panel User Manual provided as a downloadable document at www.hubbell-automation.com. CX PANEL SPECIFICATIONS Panel Input Power Requirements: o Input Voltage 2 designator 100VA, 120-277VAC universal o Input Voltage 3 designator 100VA, 347-480VAC universal Overall Dimensions: o Surface mount, 20 W x 24 H x 3.5 D. Relay Load Ratings: o CXR2N 120/277VAC, Electrically Held, N/O, 20Amps, HID and Fluorescent Ballast 15Amps, Fluorescent Electronic Ballast 16 Amps, Tungsten (120V only) 15 Amps, 3/4HP at 120V and 277V, o CXR3L 120/277/347VAC, Latching, 30Amps, HID and Fluorescent Ballast at 120/277 VAC, Fluorescent Electronic Ballast 16 Amps, and 20A mps Tungsten at 120VAC, 1HP at 120V, and 20Amps, HID and Fluorescent Ballast at 347V o CXRTN 208/240/480VAC, Electrically Held, N/O, 20Amps, HID, Ballast, 2HP o CXR2C 120/277VAC, Electrically Held, N/C, 20Amps, HID and Fluorescent Ballast 15Amps Fluorescent Electronic Ballast 16 Amps, Tungsten (120V only) 15 Amps, 3/4HP at 120V and 277V, o CXRTC 208/240/480VAC, Electrically Held, N/C, 20Amps, HID, Ballast, 2HP Low Voltage Inputs: o CX 16-Relay Panel 20 available inputs o CX 24-Relay panel 30 available inputs. o Low Voltage Switches 2 or 3 wire momentary or maintained style, with or without LED indication. LED indication support is LED ON when switch is active and LED OFF when switch is inactive. Green ON with Red OFF indication is not supported. o Motion Sensor Input Three wire 24 VDC o Photocell Three wire 24VDC power, 0-10V DC control input. Output Relay Contacts o Two each for 16-Relay panel only Dry Contact Output, NO/NC, 24V AC/DC, 50mA o Three each for 24-Relay panel only Dry Contact Output, NO/NC, 24V AC/DC, 50mA Operating Environment: o Indoor Use Only; 0 to 50 C; Relative Humidity: 0 90% non-condensing. PANEL LOAD SCHEDULE FORM A Panel Load Schedule Form is supplied in the clear plastic pocket inside the Panel Door to record the lighting circuit relay assignments while connecting the relays. Low voltage input types and assignments should also be recorded on the form. Page 6 72-00517 Rev. A