Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Similar documents
Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Industry leading low energy evaporative fresh air cooling.

High Efficient Data Center Cooling

Green IT Project: The Business Case

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Next Generation DCP Optimization using MV VSDs

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Ecotel Free Cool 5-15kW

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Variable Speed Drives

Designing Ultra-Efficient Building Cooling Systems

Rack cooling solutions for high density racks management, from 10 to 75 kw

Switch to Perfection

MSYS 4480 AC Systems Winter 2015

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Variable Speed Drives

The new generation of dedicated HVAC drives

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

Data Center Energy Savings By the numbers

Nominee: Prefabricated, Pre Assembled Data Centre Modules by Schneider Electric

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Chiller Replacement and System Strategy. Colin Berry Account Manager

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Altivar 212 Drive. A variable speed AC drive for 1 to 100 HP, three-phase asynchronous motors. Make the most of your energy SM

Liebert DCW CATALOGUE

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Data Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1

IT Air Conditioning Units

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Retro-Commissioning Report

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

Air-Cooled Series R Chiller

Thermal management. Thermal management

Dykin Engineering Part & Services Sdn. Bhd.

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Energy Action Plan 2015

Improving the climate for data centers

ENCLOSURE HEAT DISSIPATION

Dedicated to HVAC business VLT Drives

FCU (FREE COOLING UNIT)

Presentation. Guaranteed Energy Savings Performance Project

INNOVATE DESIGN APPLY.

Total Modular Data Centre Solutions

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

INNOVATE DESIGN APPLY.

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Data Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala

Achieving Operational Excellence

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

Your choice for wall and panel mounted AC drives. Emotron FDU & VFX IP20/21 up to 132 kw

Energy Saving in Cleanrooms

Silicon Valley Power Data Center Program Rebate Application

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

FLORIDA STATE UNIVERSITY MASTER PLAN 10 Utilities

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

SMARTER BUILDING. Give your buildings a new dimension Scalable solutions for energy and asset management

Committed to Energy Efficiency

ABB i-bus KNX AC/S Application Controller

Table of Contents. Executive Summary Site and Unit Background Chiller Chiller Appendix... 11

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

District Cooling Marches on in Dubai The Emirates Towers Case Study

PROCESS COOLING STUDY WORKSHEET

The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER

Your data center s hidden source of revenue

Case study on Green Data Center. Reliance Jio Infocomm Limited

Building Tune-Up Program Application

Invitation for Expression of Interest (Eol) to Participate as an ACT-Shop Pilot Project

Data Center Optimized Controls

E e n rgy g y St S ud u y y Pr P og o r g ams December 2011

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

where we are, where we could be, how we can get there. 12/14/2011

HIGH DENSITY RACK COOLING CHOICES

MOLLIER DIAGRAM CAN BE IMPROVED!

MEASURE MONITOR UNDERSTAND

Driving Proactive Facility Operations with Automated HVAC Diagnostics

A BSRIA Guide. Free Cooling Systems BG 8/2004 FREE COOLING SYSTEMS BSRIA By Tom De Saulles. Supported by

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

Efficiency of Data Center cooling

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

multi-utility metering a total systems approach

4-step Chiller and Heat Pump Controller

Case Study The University of Warwick

Transcription:

Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

The power behind the data Private and public businesses, from banks to supermarkets, to telecommunications companies and internet providers depend on data centres for gathering, storing and managing vast volumes of data in a reliable, efficient and secure way, powering everything from online shopping transactions through to storage and retrieval of hospital records. Any form of data loss can have a disastrous impact on the business. As such, data centres suffer high operating and maintenance costs. Not surprisingly, they require massive amounts of power to keep them running smoothly and efficiently. The everincreasing demand for computing power has a significant impact: with the new technologies, between 20-22 kw of power is required for each single rack, compared to 4-5 kw normally needed in the past. In the future, these environments will become one of the main consumers of power in the world. With the continued growth of the internet and electronic banking, the need to deliver data storage solutions that also help improve energy efficiency and the levels of power used within such a centre has never been greater. All of which affects plant costs: the electrical and mechanical aspects of a new office building usually equal to 15 percent of the investment, but with a data centre this value increases to 70 percent. CRC Energy Efficiency Scheme Data centres that consume more than 6 GWh/year and use a half-hourly meter, must register for the CRC Energy Efficiency Scheme - a mandatory scheme to promote energy efficiency and reduce carbon emissions. CRC Energy Efficiency Scheme is a UK based cap and trade scheme, similar to the EU ETS scheme, and is the UK government s preferred method when it comes to controlling emissions. Although revenue neutral to the Exchequer, CRC Energy Efficiency Scheme will have cash flow implications for qualifying organisations. An energy saving of 5% will be needed to cover the average cost of administration within an organisation. CRCs treat whole sections of economy as a single entity and set targets for group rather than individual companies. Each organisation is allocated an agreed number of carbon credits which decreases over time. Those individual organisations that can reduce their emissions easily are able to sell their credits to those organisations who have not met their targets. The cost of carbon credits will be paid back to participating organisations. However, payment will be based upon a league table of energy efficiency performance. Those organisations able to reduce their consumption the greatest receive the initial cost plus an additional 10% in year one and those at the bottom of the table get their initial cost minus 10%. This rises to +/ 50% by year five. 2 The power behind the data l A guide to using variable speed drives and motors in data centres

Because many pump and fan systems run at less than full capacity for much of the time, variable speed drives can produce huge savings. If a 100 kw fan is throttled by 20%, for example, the investment in a variable speed drive will have a payback of typically six months based on continuous operation. Benefits of variable speed drives Commercial Reduced energy consumption from 20 to 50 percent Fast payback from six months Reduced CO 2 emissions Enhanced Capital Allowance (ECA) Interest-free loan from the Carbon Trust Contribute to meeting Carbon Reduction Commitment (CRC) Variable speed drives Data centre running costs can be significantly reduced by as much as 50 percent with variable speed drives from ABB. These devices control the flow of pumps and air conditioning fans to eliminate the energy waste that is common with conventional pump and fan control methods. Typical savings Typical data centre may have approx. 70 fixed speed motor applications. Average power per motor is 7.5 kw. Typical motor power could be > 0.5 MW. Typical running costs could be > 450 k per annum Typical financial savings could be > 20% i.e 90 k per annum. Payback < 2 years. How variable speed drives work Many existing pump and fan systems are based on throttling arrangements: the motor is driven at full speed and then the flow of liquid or gas is regulated by valves, vanes or similar throttling mechanisms. Throttling the output in this way wastes energy. An AC drive can increase the system s efficiency by adjusting the motor speed to the correct operation point and eliminating the need for throttling. A small reduction in speed can make a big difference in energy consumption. A centrifugal pump or fan running at 80% speed consumes only half as much energy as a unit running at full speed. This is because the power required to run a pump or fan changes with the cube of the speed. Technical Lower maintenance costs Starting, stopping and braking can easily be programmed to reduce stress on mechanical equipment Increases equipment life and reduces maintenance requirements for pumps, motors and pipework Easily retrofitted into an installation Real time clock Can easily set up programmes with different running speeds at different times or on different days Low harmonic solutions available as part of installation design Who benefits from variable speed drives and motors Financial controller Significantly reduced energy bills Rapid return on investment Access to Carbon Trust loans Qualify for Enhanced Capital Allowance (ECA) Contributing to Carbon Reduction Commitment (CRC) obligation Lower maintenance costs Substantial contribution to environment by lower CO 2 emissions Facilities manager Gain control of air conditioning costs Easily retrofit VSD to installation Maintenance engineer Reduced maintenance on pumps and fans, hence lower costs Adjusting speed according to demand saves wear and tear on pumps, fans and motors The power behind the data l A guide to using variable speed drives and motors in data centres 3

Data centre applications for variable speed drives Challenges facing air conditioning As the servers are always operating around the clock, one of the highest operating costs is the air conditioning, which is normally set to 20 C and requires one watt per watt used in computing functions. Air conditioning is used to control the temperature and humidity in the data centre. The recommended temperature range is between 20 to 25 C (68 to 75 F) and humidity range of 40 to 55% with a maximum dew point of 17 C as optimal for data centre conditions. The electrical power consumed by the servers heats the air in the data centre. Unless the heat is removed, the ambient temperature will rise, resulting in electronic equipment malfunction. By controlling the air temperature, the server components at the board level are kept within the manufacturer s specified temperature/humidity range. Air conditioning systems help control humidity by cooling the return space air below the dew point. Too much humidity, and water may begin to condense on internal components. In case of a dry atmosphere, ancillary humidification systems may add water vapour if the humidity is too low, which can result in static electricity discharge problems which may damage components. ABB s electrical solutions for data centres Low voltage switchboards MNS system ipdus (Power Distribution Units) Active filters Power factor correction ipdus (Power Distribution Units) Remote power panel Power measurement Automation switchboards Variable speed drives PLC Control gear Air-isolated medium voltage switchboards Dry-type transformers i-bus EIB/KNX High-efficiency motors Variable speed drives 4 Data centre applications for variable speed drives l A guide to using variable speed drives and motors in data centres

Supply fan (A) Room air quality is controlled by changing the speed of the supply fan according to the CO 2 content of the exhaust air. The outdoor air damper will be opened when the fan is started. Operation is enabled when the damper is fully open (damper end switch). Accurate control to keep desired air quality/co 2 content Reduced maintenance of mechanical equipment such as belts and bearings due to reduced operating speeds and AC drive soft starting and stopping Easier to maintain low noise levels Approximately 30% reduction in CO 2 emissions and energy Return fan (B) Room pressure is controlled by changing the speed of the return fan according to the exhaust duct pressure. Return fan keeps up constant pressure in the exhaust duct by using PID control. Exhaust air dampers will be opened when the fan is started. Operation is enabled when damper is fully open (damper end switch). Accurate control to keep desired duct pressure Reduced maintenance of mechanical equipment such as belts and bearings due to reduced operating speeds and AC drives soft starting and stopping Easier to maintain low noise levels Approximately 30% reduction in CO 2 emissions and energy C Liquid cooler fans (C) Liquid cooler fans are controlled according to the temperature of the condenser water outlet. Condenser water temperature is kept constant with PID control. To prevent unnecessary cooling, liquid cooler fans are not started until the condenser water pump exceeds maximum speed. If water temperature falls too low, circulation can be stopped with a solenoid valve. Fans can also be programmed to run fixed speed for a certain time, for example once a week, to avoid condensation in the motors. B Easier to maintain low noise levels Accurate control to keep desired condenser water temperature Approximately 15% reduction in CO 2 emissions and energy A Data centre applications for variable speed drives l A guide to using variable speed drives and motors in data centres 5

Condenser water pump (D) Condenser water pump is controlled with a PID controller according to the temperature of the condenser water. Operation is enabled when the chilled water pump and the chiller compressor are running. Accurate control to keep desired condenser water temperature Elimination of water hammer due to soft starting and stopping Reduced pump and pipe sizes Approximately 25% reduction in CO 2 emissions and energy Chilled water pump (F) Chilled water pump circulates chilled water in a cooling coil according to the temperature of the supply air. Operation is enabled when the duct temperature rises above a preset level and chiller compressor is running. Accurate control to keep desired duct temperature Elimination of water hammer due to soft starting and stopping Reduced pump and pipe sizes Approximately 25% reduction in CO 2 emissions and energy Chiller compressor (E) The need for chilled water or CO 2 cooled racks can lead to space problems for one square metre of technical space, one square metre of plant space is required plus two square metres of ancillary and accommodation space. This excludes any main substation(s) that may be required. An AC drive optimizes compressor motor speed to actual cooling demand. The compressor is controlled according to the temperature of the chilled water. The compressor s minimum speed is 60 per cent of its normal speed. Operation is enabled when chilled water pump and condenser water pump are running. Approximately 20% - 50% energy reduction Reduced peak demand charges Elimination of water hammer or hydraulic shock due to soft starting and stopping Increased chiller life Tighter chilled water temperature control Reduced maintenance demand Approximately 20% reduction in CO 2 emissions and energy E F D 6 Data centre applications for variable speed drives l A guide to using variable speed drives and motors in data centres

Life cycle support The drive for the future When you choose an ABB drive, you automatically become part of the most comprehensive product life cycle management scheme in the industry. Product life cycle management model The life cycle management model divides a product s life cycle into four phases: active, classic, limited and obsolete. Each phase has different implications for the end user in terms of services and support provided. In the active phase the end user benefits from warranty options and a full range of life cycle services, spare parts and maintenance materials. This phase ends when the volume production of a particular product ends and the classic phase starts. In addition to offerings available in active phase, end users may migrate to new technology by using upgrade and retrofit solutions providing improved performance and extension of the life cycle. After the classic phase products enter the limited phase and end users are recommended to start planning a transfer to new technology before product support ceases. Spare part services continue as long as components and materials are available, and throughout the course of time the use of reconditioned parts increases. A product is transferred to the obsolete phase when it is no longer possible to provide life cycle services within reasonable cost or the old technology is no longer available. Benefits of product life cycle management Product life cycle management maximizes the value of equipment and maintenance investments by: ensuring spare part and competence availability throughout the life cycle enabling efficient product support & maintenance for improved reliability adding functionality to the initial product by following the upgrade path providing a smooth transition to new technology at the end of a product s life cycle helping the end user to decide when an upgrade, retrofit or replacement is required ABB s life cycle management model ensures that the required product support is always available and paves the way for a smooth transition to a new product at the end of the life cycle. A drive product will remain current for about 5 to 10* years, known as the active phase. After this, service support will remain available for a further 5 to 15 years, the classic phase. Through contact with ABB you will be kept up to date with the support plans for your drive. At the end of the product life, you will be recommended an appropriate replacement. The old drive will be removed and recycled in accordance with local regulations. * Dependent on size of drive Life cycle support l A guide to using variable speed drives and motors in data centres 7

Contact us ABB Limited Daresbury Park Daresbury Warrington Cheshire WA4 4BT Tel: +44 (0) 1925 741 111 Fax: +44 (0) 1925 741 212 www.abb.co.uk/energy Notes: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Ref: Data Centre brochure/nov 2009/2,000 Copyright 2009 ABB All rights reserved Printed in UK (11.2009)