LIFE SAFETY PRODUCTS

Similar documents
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Camden - Key Switches

Digital Keypad Introduction

LOCKNETICS Access Controls. Credentials. Access Controls. ibutton Readers

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

212iL Rev. 1.1

Installation Instructions 4291 and 4292 Keypads

SkimGard TM DEMO KITS. ATM Looby CARD READERS. Building Access. Access Control. Cellular Gateway. Instructional Decals. ATM Access Control Catalog

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

ecna-5 D-Cinema Automation System

GV-EL124S Electric Strike

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

DG-800 Stand-Alone Proximity Reader Instruction Manual

INTELLIKEY. Mini-DCU Installation Manual GENIUS AT YOUR FINGERTIPS. 1 rev

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

DAK1-ATS1. Features. Accessories. Options

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

TELEPHONES & CABINETS

2000 Series e/em Style Keypad Installation and Programming Manual

KP2000E/EM Series Style Keypad

RFID/Digital Access Control Keypad

Quick Start Installation Guide

Two Door Controller GEN-045

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Pegasus HC Lighting Control Panel

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

YOU FOR CHOOSING UNITEC PARTS COMPANY UNITEC PARTS COMPANY

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

Tek-ENTRY Telephone Entry System. Specification Sheets Submittal Package. as of 10/4/2010

AirTest Model CN9000 Series Sensor Controller

SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

THIS FORM IS THE PURCHASE ORDER. DO NOT SEND A COVER P.O. DUPLICATED ORDERS CANNOT BE RETURNED. Technology/Description

ATM Lobby Access Control

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

DCU Installation Manual

Waterproof. Keypad/Reader/Controller

DOLXFD1000B. Waterproof Access Control/Reader

232iLM Keypad Installation and Programming Instructions

W3-M. Metal waterproof standalone access control/reader. User Manual

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices

User Manual. PCKeypad Wireless Keypad

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Rev 1.00

PAC1 Door Access Controller

PAC1 Door Access Controller

January 2019 PRICE SCHEDULE A 2.0 Access Control Devices

Connecting a Cisco Input Module

W3-H Waterproof Keypad/Reader/Controller

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

ACTsmart2 Product Range Operating and Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

Innovative POWER Solutions

AS Keypad User Manual

K44 Code lock. Technical manual

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com

Key Switch. Document version: 1.5 (Updated 02 May 2017)

SAVE THESE INSTRUCTIONS

791/793 Easy Entry Keypads

Connecting a Cisco Reader Module

Smart Ocean Smart Rim Lock Data Sheet

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

DSK-XXXXC DSK-XXXXP. Telephone Entry Door Intercom

Fingerprint Access Control F1. User Manual

PAC2 Dual Door Access Controller

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Single Door Standalone Access Control User Manual

8000 Series: Installation Supplement R2-1-12

PRO3200 Professional Modular Access Control Hardware

Aperio. Wireless Possibilities for Online Access Control. Key Features: Warranty: Technical Information: 48 Aperio

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

LED Design Lighting STANDARD Products Inc. All Rights Reserved. Rev. March 22, 2018.

SKE Series. 12-Pad. Installation & Instruction Manual. Essex Electronics, Inc KEY-LESS fax keyless.

Aluminum Mailboxes - Standard System

CATALOGUE D45 High performance door entry system

SAVE THESE INSTRUCTIONS

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR-

Specification Sheet: HT SERIES

TOUCHLOCK compact. Ins-182 Date code:

4C Std Horizontal Mailboxes - cont. on pgs 14-19

SK-1011-SQ Digital Access Keypad with 5A Relay Output

Distributed Power Series

9212i INSTALLATION. Stand-Alone Keypad. Instructions

MAXIMA + Series ROTARY LEVEL CONTROL

INSTALLATION INSTRUCTIONS

Transcription:

TM DynaLockSM For Life 8000 Series Standard & Custom Consoles LIFE SAFETY PRODUCTS F U L L Y I N T E G R A T E D S E C U R I T Y S Y S T E M S E l e c t r o m a g n e t i c L o c k s C o n t r o l s P o w e r S u p p l i e s

8000 Series Standard Consoles General Description The 8000SF Series Standard Slope Front Console is designed to provide basic remote monitoring and control of doors equipped with electromagnetic locks, electric strikes or other similar electronic locking devices. The Console may be ordered with up to 12 individual zones, each consisting of one red and one green LED indicator and one toggle switch. The LED s provide remote lock and/or door status indication when triggered by a dry contact closure from an external signal switch included in the locking device or elsewhere on the door or system (i.e. door position contact, alarm sensor, etc.). The toggle switches may be specified as either maintained or momentary action and provide SPDT dry contacts for lock control or other remote control functions. The Console is housed in a low profile, slope-front metal enclosure with a powder coated black front panel. It may be specified to operate on 12 or 24VDC input power. RED LED GREEN LED No. of Stations A B C TOGGLE SWITCH 1-3 6.5 8.3 3.0 4-5 10.0 8.3 3.0 C 6-8 14.0 8.3 3.0 9-12 17.0 8.3 3.0 B A Note: All dimensions shown in inches. Accessories LK LABEL KIT Kit includes engraved adhesive backed nameplates to number stations 1 thru 12 and five nameplates to label functions SECURE, UNSECURE, CLOSED, OPEN and RELEASE as required. (Order Separately) Notes 1. 2. If the LED s are labeled SECURE and UNSECURE DynaLock maglocks should include the DYN or HSM option to control the LED s. If the LED s are labeled CLOSED and OPEN DynaLock maglocks should include the DSM option to control the LED s. Part Number Configuration 80XXSF - XX - XXX Number Of Stations 01-12 Toggle Switch Function MOM = Momentary Action MAINT = Maintained Action LED Operating Voltage 12 = 12VDC 24 = 24VDC 2

TM DynaLockSM For Life 8000 Series Standard Consoles Typical System Wiring 12 or 24VDC Input 2 5 5 8002SF Standard Slope Front Console Door #1 (Magnetic Lock) Door #2 (Electric Strike) Doors require door status switch or lock status sensor for LED indicator monitoring. Specifications Input Power: Monitoring: Control: 12 or 24VDC @ 0.100 Amps per station. Two (2) LED indicators per station - One (1) Red and One (1) Green. One SPDT toggle switch per station. May be either momentary or maintained action, as ordered. Output contacts rating: 2 Amps @ 30VDC. 3

8000 Series Custom Consoles General Description 8000 Series Custom Consoles are specially fabricated to customer requirements. The factory must be consulted for specific pricing, delivery and performance specifications. All Consoles, regardless of configuration, share common monitoring and control functions. DynaLock has developed a universal control module to perform these functions. It satisfies the majority of installations, keeps initial cost to a minimum and facilitates service. Please refer to page 7 Custom Console Quotation Questionnaire before contacting DynaLock for a price quotation. Enclosure/Panel Styles Custom Slope Front (CSF) Custom consoles are available in four enclosure styles. The style selected may be based on customer preference or dictated by space required for custom options. CSF - Custom Slope Front Series are capable of performing additional control and monitoring functions with increased station capacity beyond the standard SF Series. DT - Desk Top Series are furnished in blue turretstyle cabinets with brushed aluminum front panels. Cabinet size and shape are configured to reflect console function. Desk Top (DT) WM - Wall Mount Series front panels are furnished in a brushed aluminum finish and include a removable steel back-box. Size will vary by number of stations and options selected. RM - Rack Mount Series consoles are furnished on standard 19 wide brushed aluminum panels, less backbox. Size will vary by number of stations and options selected. Note: Console style availability may be limited by the number of station spaces selected. Refer to the selection guide on page 5 to configure a custom console with the features desired. Based on your selection DynaLock will confirm enclosure style availability. Wall Mount (WM) Rack Mount (RM) 4

TM DynaLockSM 8000 Series Custom Consoles Individual Station Configuration Selection Select one station configuration - all stations must be identical. CONTROL ONLY MONITORING & CONTROL MONITORING ONLY For Life T TL1 TL2 TL3 L1 L2 L3 Optional Master Control Stations Console may include one/each of the three options. MASTER ALARM MASTER OVERRIDE MASTER LOCKOUT MA MOT MOK MOC MLT MLK MLC Allow Two Station Spaces Red LED is console power ON indicator. Audible is used to indicate a violation condition and includes a audible mute toggle switch. Allow Two Station Spaces Select one style of Master Override switch: Toggle Keyswitch Mortise Cylinder Master Override releases all stations simultaneously. Allow Two Station Spaces Select one style of Master Lockout switch: Toggle Keyswitch Mortise Cylinder Master Lockout disables all individual station toggle switches. 5

8000 Series Custom Consoles Custom Console Part Number Configuration Example: 8006 CSF - 24 - TL2 - MA - MOC Number Of Stations Optional Master Control Stations Individual Station Configuration Console Operating Voltage 12 = 12VDC 24 = 24VDC Enclosure/Panel Style 6

TM DynaLockSM 8000 Series Custom Consoles 8000 Series Custom Console Quotation Questionnaire For Life Complete the following questionnaire. Copy and fax it to DynaLock s Sales Engineering Department for a prompt price and delivery quotation. Refer to pages 4 and 5 for further information. Style of Console: o CSF Type of electric lock(s) to be controlled: Input Voltage: 12V 24V Number of Stations: RM Electromagnetic With delay egress DT Electric Deadbolt Fail-Safe Fail-Secure WM Electric Strike Fail-Safe Fail-Secure Locks to be controlled have the following options: o Door Status o Lock Status o Anti-Tamper Console to: o Control/Monitor Control Only Monitor Only Individual Station Type: T TL1 TL2 TL3 L1 L2 L3 Type of Control Switch: Maintained Contact Momentary Contact Light color preferences from top to bottom: (Red, Green, Yellow). (T) (M) (B) Master Alarm Station with Audible (MA): Yes No If Yes Audible Signals: Door Status (open) Lock Status (unlocked) Delay Egress (3101B lock) Standard: Audible will sound when condition occurs and continue until condition is corrected. Other - Explain: Master Alarm Station includes mute switch to silence audible (audible will silence but will be overridden with new alarm condition) and red power ON LED. Master Override: MOT MOK MOC Master Lockout: MLT MLK MLC System Description of Operation: Type on a separate page. 7

Featuring DynaLife Lifetime Warranty DYNALOCK CORPORATION 705 EMMETT STREET, PO BOX 2728, BRISTOL, CT 06011-2728 PHONE: 877-DYNALOCK / FAX: 860-585-0338 E-MAIL: INFO@DYNALOCK.COM / WEBSITE: WWW.DYNALOCK.COM 3/08