E (sensor) is given by; Object Size

Similar documents
Electromagnetic waves and power spectrum. Rays. Rays. CS348B Lecture 4 Pat Hanrahan, Spring 2002

Measuring Light: Radiometry and Cameras

Measuring Light: Radiometry and Photometry

Radiometry. Computer Graphics CMU /15-662, Fall 2015

Measuring Light: Radiometry and Photometry

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

INFOGR Computer Graphics. J. Bikker - April-July Lecture 10: Shading Models. Welcome!

Design Verification and Analysis Tools in TracePro. Presented by : Lambda Research Corporation 25 Porter Rd. Littleton, MA

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

Understanding Variability

Spectral Color and Radiometry

Optics Part 1. Vern Lindberg. March 5, 2013

MODELING LED LIGHTING COLOR EFFECTS IN MODERN OPTICAL ANALYSIS SOFTWARE LED Professional Magazine Webinar 10/27/2015

Introduction to Computer Vision. Introduction CMPSCI 591A/691A CMPSCI 570/670. Image Formation

Introduction to color science

Mu lt i s p e c t r a l

4. A bulb has a luminous flux of 2400 lm. What is the luminous intensity of the bulb?

Investigation of an Alternative Method for Measuring the Spectral Irradiance of a High-Powered Focused Light Source

CS-184: Computer Graphics. Today. Lecture 22: Radiometry! James O Brien University of California, Berkeley! V2014-S

Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question

Radiometry (From Intro to Optics, Pedrotti 1-4) Radiometry is measurement of Emag radiation (light) Consider a small spherical source Assume a black

Cameras and Radiometry. Last lecture in a nutshell. Conversion Euclidean -> Homogenous -> Euclidean. Affine Camera Model. Simplified Camera Models

WAVELENGTH MANAGEMENT

Photometric Stereo.

Integrating Sphere Uniform Light Source Applications

Announcements. Lighting. Camera s sensor. HW1 has been posted See links on web page for readings on color. Intro Computer Vision.

GEOG 4110/5100 Advanced Remote Sensing Lecture 2

Philpot & Philipson: Remote Sensing Fundamentals Interactions 3.1 W.D. Philpot, Cornell University, Fall 12

WAVELENGTH MANAGEMENT

Radiometry & BRDFs CS295, Spring 2017 Shuang Zhao

OPSE FINAL EXAM Fall CLOSED BOOK. Two pages (front/back of both pages) of equations are allowed.

NPaboutBlueLightfromCN-NCvsIECTR62778:2014

Rays and Throughput. The Light Field. Page 1

Introduction to Computer Vision. Week 8, Fall 2010 Instructor: Prof. Ko Nishino

The Elements of Colour

Lighting. Camera s sensor. Lambertian Surface BRDF

Reflectance & Lighting

CS667 Lecture Notes: Radiometry

Radiometry and reflectance

CENG 477 Introduction to Computer Graphics. Ray Tracing: Shading

Light Field = Radiance(Ray)

Light Tec Scattering measurements guideline

Capturing light. Source: A. Efros

Throughput of an Optical Instrument II: Physical measurements, Source, Optics. Q4- Number of 500 nm photons per second generated at source

Formulas of possible interest

The Light Field. Last lecture: Radiometry and photometry

Accurate LED Source Modeling using TracePro

Diffraction Challenge Problem Solutions

High Speed Digital Microscope

Reflective Illumination for DMS 803 / 505

Engineered Diffusers Intensity vs Irradiance

OPPA European Social Fund Prague & EU: We invest in your future.

Global Illumination The Game of Light Transport. Jian Huang

CS6670: Computer Vision

Light Tec Scattering measurements guideline

Light Tec Scattering measurements guideline

Global Illumination. CMPT 361 Introduction to Computer Graphics Torsten Möller. Machiraju/Zhang/Möller

2.710 Optics Spring 09 Solutions to Problem Set #1 Posted Wednesday, Feb. 18, 2009

Color and Shading. Color. Shapiro and Stockman, Chapter 6. Color and Machine Vision. Color and Perception

Light and reflection

Photobiological Measurement Per IEC Solutions Overview. Gooch and Housego (Orlando)

ratio of the volume under the 2D MTF of a lens to the volume under the 2D MTF of a diffraction limited

ISP Series. Integrating spheres for all applications. We bring quality to light.

Image Formation: Light and Shading. Introduction to Computer Vision CSE 152 Lecture 3

Physical Optics. You can observe a lot just by watching. Yogi Berra ( )

Chapter 8: Physical Optics

CS 5625 Lec 2: Shading Models

Lecture 1 Image Formation.

Paths, diffuse interreflections, caching and radiometry. D.A. Forsyth

Calibration of Recorded Digital Counts to Radiance

Ray Tracing: Special Topics CSCI 4239/5239 Advanced Computer Graphics Spring 2018

Light and reflection

Physics 202 Homework 9

ams AG TAOS Inc. is now The technical content of this TAOS document is still valid. Contact information:

Computer Vision. The image formation process

CS5670: Computer Vision

Lecture 22: Basic Image Formation CAP 5415

Estimating the wavelength composition of scene illumination from image data is an

BLACKOUT FLEX BB TECHNICAL DATA SHEET » ARTICLE CODE» WIDTH» LENGTH» WEIGHT » COMPOSITION » FLAME RESISTANCE » AVAILABLE COLOURS.

Source Four Zoom 15-30

Radiance. Radiance properties. Radiance properties. Computer Graphics (Fall 2008)

Light Tec Scattering measurements guideline

Application of a Model to Evaluate Infrared Exposure Limits in Aluminum Foundries Based on Threshold Temperature in the Range of nm

Image Diode APPLICATIONS KEY ATTRIBUTES

Color to Binary Vision. The assignment Irfanview: A good utility Two parts: More challenging (Extra Credit) Lighting.

(0, 1, 1) (0, 1, 1) (0, 1, 0) What is light? What is color? Terminology

Reprint (R30) Accurate Chromaticity Measurements of Lighting Components. Reprinted with permission from Craig J. Coley The Communications Repair depot

Color. Reading: Optional reading: Chapter 6, Forsyth & Ponce. Chapter 4 of Wandell, Foundations of Vision, Sinauer, 1995 has a good treatment of this.

Why does a visual system need color? Color. Why does a visual system need color? (an incomplete list ) Lecture outline. Reading: Optional reading:

Draft SPOTS Standard Part III (7)

CinCam CCD - Technical Data -

CS6670: Computer Vision

Optimization of optical systems for LED spot lights concerning the color uniformity

ETC. Source Four jr Zoom. Ellipsoidal Series. Source Four jr Zoom. Connector Designation

Council for Optical Radiation Measurements (CORM) 2016 Annual Technical Conference May 15 18, 2016, Gaithersburg, MD

Chapter 36. Diffraction. Copyright 2014 John Wiley & Sons, Inc. All rights reserved.

x ~ Hemispheric Lighting

ETC. Source Four Zoom Ellipsoidal Series. Source Four Zoom. Connector Designation

Overview. Radiometry and Photometry. Foundations of Computer Graphics (Spring 2012)

Announcements. Radiometry and Sources, Shadows, and Shading

Transcription:

A P P L I C A T I O N N O T E S Practical Radiometry It is often necessary to estimate the response of a camera under given lighting conditions, or perhaps to estimate lighting requirements for a particular camera. To assist with these calculations a number of examples are given below for common problems. It should be recognized that very accurate calculations are difficult; it is often better to start with a simple estimate and then fine tune the set up experimentally. A conversion table is provided to enable different measurement units to be compared; all calculations are carried out using radiometric SI units (see the CCD technology primer in this data book). 1. Magnification and Resolution The camera system is to be set up such that each pixel in the CCD sensor corresponds to a set feature size on the object. What is the required magnification of the camera? The answer depends on the pixel size, the focal length of the camera lens, f, the distance from the object to the lens, OD and the distance from the lens to the image, ID. (Please see Figure 1.) The magnification can be given by: size of image ID f m = = = size of object OD OD when the focal length of the lens is much smaller than OD this can be simplified to m =f/odandhence the required OD is given by OD = f / m. The required magnification is m = 10µm / 1mm = 0.01, Example: pixel size = 10µm x 10µm focal length of lens = 55mm object feature size = 1mm hence OD = 55 / 0.01 = 5.5m f 2. Camera Output with Monochromatic Light Source I have a monochromatic light source, such as a green phosphorous screen in an image intensifier. (Please see Figure 2.) What is the output from the camera? The answer depends on the responsivity of the camera, the camera lens and the distance, from the object to the lens. It conveniently turns out that for an image formed by an optical system in which the losses are negligible, the radiance of the image is the same as that of the object. This may sound counterintuitive since it is well known that when a lens is used to focus an image on a screen its brightness to the observer increases as the magnification is decreased. However, if the image is observed directly by the eye, its brightness appears unchanged. This is because when the magnification is decreased, the flux per unit area is increased, but the total solid angle is also increased in such a way that the radiance remains constant. Therefore, given the radiance of an object L (object), the radiance of the image is essentially the same, subject to losses in the lens characterized by T r, the radiance transmittance. In order to calculate the irradiance at the sensor it is then a simple matter to multiply the radiance by the solid angle subtended by the lens at the sensor. This will depend on the diameter of the lens, and if an iris is employed to stop down the lens, it will depend on the diameter of the iris, d. The solid angle subtended at the sensor is the ratio of the active lens area ( 1/4 π d 2 ) to ID. Hence, by expressing ID in terms of the magnification, and the iris diameter in terms of the f-number, the irradiance, of the sensor E (sensor) is given by; E ( sensor) = T L π m ( ) [( )( )] ( ) r object W 2 2 2 f /# m + 1 when the magnification is small, this simplifies to E (sensor) =Tr L (object) / (2( f/#)) 2 Image Size Figure 1. Example 1 ID OD Object Size Example: radiance(object) = 2 µw cm -2 Sr -1 f/# = 1.4 assume a perfect lens T r = 1 required magnification = 0.01 The irradiance at the sensor is therefore = 0.8µW/cm 2. 03-36-00008-00 DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023 325 www.dalsa.com DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746 ISO 9001

Application Notes For product information and updates visit www.dalsa.com O/P Example: Figure 2. Example 2 Camera Irradiance Radiance line rate of camera (LVAL) = 1.5kHz wavelength = 546nm Phosphor Screen The output from the camera will depend on its responsivity at the wavelength of interest and the integration time of the sensor. First, we refer to the performance characteristics of the camera to find the peak responsivity. Consider an example camera giving 126 DN/(nJ/cm 2 ), measured at 800nm. This determines the output of the camera for a given radiant energy density. The next step is to relate this information to the wavelength of interest. We refer to the spectral responsivity curve for the camera s sensor. The responsivity at the wavelength of interest (546nm) is found to be lower than that at the wavelength used to characterize the camera (800nm) by 58%. Hence the responsivity for the camera at 546nm is reduced by 58% to 53DN/(nJ/cm 2 ) for the analogue and digital cameras respectively. The camera is to be operated at a line rate of 1.5kHz, corresponding to an integration time of 0.67ms. The radiant energy density at the sensor is simply the irradiance (a power density) multiplied by the integration time, which in this case gives 0.54nJ/cm 2. Therefore the output from the camera (without a lens) would be 29DN. 3. Convert photometric to radiometric units - Monochromatic Suppose that in the last example the source had been characterized by a luminosity of 4 ASB (apostlib), a photometric unit. Before calculating the camera output it is necessary to convert this to an SI radiometric unit. We refer to conversion Table 1 to find that 1 ASB is equivalent to 0.318 lux / Steradian, which can be converted to radiance with the knowledge that 1 lux is equivalent to 1.49µW/m 2 of monochromatic light at 546nm. Hence, 4 ASB becomes 1.9µW cm -2 sr -1, which is roughly the same as that used in the previous example. The same basic idea is valid for the conversion of other photometric units. 4. Illumination of Object - Monochromatic Consider the case where the phosphorous screen in example 2 were replaced by a diffuse plane, illuminated by a monochromatic light source. The plane surface, or object is face-on to the camera, while the normal to the surface makes an angle ϕ with the light source. If the source is a point source it will radiate in all directions. In reality, the light source will probably incorporate a back reflector and a diffuser to provide an extended, uniform illumination source. It is important to ensure that the light source is aimed towards the object otherwise the irradiance can become very sensitive to the angle. Even in this case, the irradiance is reduced as ϕ grows larger. For an object a distance LS from the light source of diameter s, the average irradiance over a small area of the object is given by s E = L () ( ) COS ϕ π 2 source ( object) (W.m -2 ) 4 LS Assuming that the object reflects this equally into a full hemisphere (Lambertian surface) it can be shown that the radiance of the object with a reflectivity R, is given by R L = E ( object) ( object) π (W.m-2.sr -1 ) This value is used in place of the radiance of the light source in Example 2. Example: L(source) = 2µW cm -2 sr -1 R = 56% s = 5cm LS = 0.5m ϕ = 45 degrees 326 DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023 03-36-00008-00 ISO 9001 DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746 www.dalsa.com

For product information and updates visit www.dalsa.com Application Notes In this example (please see Figure 3), the radiance of the object = 2 µwcm -2 sr -1, giving the same result as in Example 2. O/P Figure 3. Example 4 Camera Light Source 5. Light Source Requirements - Polychromatic When the light source is polychromatic the full spectral response of the camera has to be taken into account. In simple terms, this amounts to repeating the monochromatic calculation for each wavelength in the range of interest. To do this accurately involves integration over the spectrum, which is probably more conveniently carried out by computer. Nevertheless, it is often sufficient to arrive at an estimate based on a simplified approach. This is accomplished by dividing the spectrum into a small number of discrete intervals, λ l -λ 2, λ 2 -λ 3,... λ n -λ (n+1). Within each interval it is assumed that the value of radiance etc. is constant and equal to the exact value it would have at the midpoint of each wavelength interval. When approximating any integrals over the spectrum it is a simple matter to take the value at the midpoint of each interval, and add them all up. Suppose then, that the user wishes to determine the lighting requirements for a given camera. The output will depend on the spectral output of the light source, the spectral reflectivity of the object and the spectral response of the camera. Furthermore, the conversion of photometric to radiometric units is complicated by the need to use the CIE Luminous Efficiendy curve (of the human eye). As this is very application specific, please contact DALSA for further help in deciding on your requirements. ϕ Example: what is the camera output when the light source is a tungsten halogen lamp, illuminating a flat piece of green (e.g. snooker table) velvet as it comes off the end of the manufacturing process? It is probably fair to assume that the velvet is uniform, of fine weave so that it may be treated as a plane homogenous diffuse scattering surface. There are now three extra factors to consider, the spectral output of the lamp, the spectral reflectivity of the velvet and the spectral response of the sensor. Color aberrations and non-uniform transmission losses by the lens are assumed to be negligible. We also assume that the velvet has been dyed with an advanced formula that is known to give a fairly uniform reflectivity of 20% across the green portion of the spectrum (500nm - 600nm), dropping to 2% otherwise. The light source is 5cm in diameter, operated at a color temperature of 3200K which is known to produce a spectral irradiance at the velvet of 0.1µW/cm 2 nm -1 at 650nm when positioned 0.5m away. The example camera used operates at 10 frames per second with an f/1.4 lens (perfect transmission) and a magnification of m = 0.01. The first step is to discretize the spectrum into a number of convenient intervals, which for this example will be restricted to 400-500nm, 500-600nm, and 600-700nm. The midpoints are thus 450nm, 550nm and 650nm. The next step is to calculate the irradiance at the light source at these wavelengths. Assuming it to be a perfect Black Body radiator, the spectral radiance (per wavelength interval, nm) of a lamp at temperature T (K), for a wavelength λ (nm), can be shown to be given by Planck s Law [W.J. Smith, Modern Optical Engineering, 2nd Edition, p.217], L( λ) = 5 πλ exp 19 3. 741x10 14388000 T λ (W cm -2 µm -1 sr -1 ) This shows why the radiance is a very strong function of the wavelength. From this equation it is possible to deduce that at T = 3200K, for a given radiance at 650nm, the radiance at 550nm is down to 66% and at 450nm it is down to 29%. It is interesting to note that the wavelength at which the radiance is maximum, which is given by Wien s displacement law, λ = 2897800 / T, is λ = 906nm (IR). The irradiance at the velvet is found by integrating the spectral irradiance curve over the wavelength range of interest. In this case we assume that the spectral irradiance is constant in each interval, fixed to the value it has at the midpoint. Thus, in the range 600nm-700nm the irradiance is 100nm times the spectral irradiance at 650nm, giving an irradiance of 10µW/ cm 2. Therefore the irradiance at 550nm is 6.6µW/cm 2 and 1 03-36-00008-00 DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023 327 www.dalsa.com DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746 ISO 9001

Application Notes For product information and updates visit www.dalsa.com at 450nm it is 2.9µW/cm 2. The reflectivity of the velvet is wavelength dependent, so we use R = 0.2 at 550nm and R = 0.02 at 450nm and 650nm. Using the second equation from example 4 the radiance of the velvet can be calculated as 64nW cm -2 sr -1 at 650nm, 420nW cm -2 sr -1 at 550nm, and 18nW cm -2 sr -1 at 450nm. Next we calculate the irradiance at the sensor using the same technique shown in example 2. Thus we have to multiply the velvet radiance values for each wavelength by 0.4 to give a sensor irradiance at 450nm of roughly 7.4 nw/cm 2,at 550nm 170nW/cm 2, and at 650nm 26nW/cm 2. The integration time when operating at 10fps is 100ms, hence the energy density at the sensor is is found by multiplying the irradiance by the integration time, yielding 0.7nJ/cm 2 at 450nm, 17nJ/cm 2 at 550nm and 2.6nJ/cm 2 at 650nm. The responsivity of the sensor is also wavelength dependent. Assume the peak responsivityof the 8-bit example camera is 10 DN/ (nj/cm 2 ), measured at 800nm. At 650nm its responsivity is reduced to 7.8DN/(nJ/cm 2 ), at 550nm to 5.6DN/(nJ/cm 2 ) and at 450nm to 2.0DN/(nJ/cm 2 ). This gives an output from the camera of 1.4DN at 450nm, 96DN at 550nm and 20DN at 650nm. Adding these together, the predicted output for the camerais roughly 117DN. It is instructive to note that the contribution from the green part of the spectrum dominates. This is mostly because the velvet is a strong reflector at this wavelength, but it is exacerbated by the strong sensor responsivity at the same wavelength. This example is over simplified, in practice a more detailed calculation is required. It is best performed numerically and should serve only as a guide before measuring the output experimentally. This example shows that for the given lighting conditions the output of the camera is only approximately one-half of its saturation voltage. Table 1. Useful conversion factors 1 ASB (apostlib) = 0.318 lux Sr -1 1 Footcandle = 1 Lumen / Ft² 1 Footcandle = 10.764 meter Candles 1 Candle = 1 Lumen/Steradian 1 Candle / m² = 3.142 x 10-4 Lambert 1 Lambert = 2.054 Candle / in² 1 Lux = 1 Meter Candle 1 Lux = 1.49µW/cm 2 at 540nm 1 meter Candle = 1 Lumen / m² 1 Lumen = average light emission of one candle into a unit solid angle (in steradians) Table 2. Radiometric Units Symbol Name SI units L e Radiance W m -2 sr -1 E e Irradiance W m -2 I e Intensity W sr -1 F e Flux W Q e Energy J Table 3. Photometric Units Symbol Name Units L v Luminance cd m -2 E v Illuminance lux (lx) I v Intensity candela (cd) F v Flux lumen (lm) Q v Energy Talbot 328 DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023 03-36-00008-00 ISO 9001 DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746 www.dalsa.com

For product information and updates visit www.dalsa.com Application Notes Multiplication Factors FROM Table 4. Conversion Between Photometric Luminance Units Cd/cm² (stilb) cd/ft² Cd/m² (nit) Lmb Ft.Lmb Mtr.Lmb (apostlib) Threshold of Unaided Vision Typical Level (clearsky) cd/cm² (stilb) 1 A 10000 π πa 10000 π 10-7 0.3 cd/ft² 1/A 1 B π/a π πb 10-4 300 cd/m² (nit) 10-4 1/B 1 10-4 π π/b π 10-3 3000 Lmb 1/π A/π 10-4 /π 1 A 10-4 3 x 10-7 1 Ft.Lmb 1/πA 1/π B/π 1/A 1 B 3 x 10-4 1000 mtr.lmb 10-4 /π 1/πB 1/π 10-4 1/B 1 3 x 10-3 10000 03-36-00008-00 DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023 329 www.dalsa.com DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746 ISO 9001

Application Notes For product information and updates visit www.dalsa.com 330 DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023 03-36-00008-00 ISO 9001 DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746 www.dalsa.com