Solar Analysis System Quick Start Instructions

Similar documents
STS Spectrometer Getting Started

Absolute Irradiance Installation and Operation Manual

2 1.1 Safety using methods Definition of warning symbols Standard accessories Installation...

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

TrueChrome Camera Quick Start Guide

NL-01 NL-01. The NL-01 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

Table of Contents. Table of Contents

Operating Manual RISH DPM Hz

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual

Light Sources opmaak.indd :32:50

SYNCERITY TM 1024 x 256

HD Lite Camera. Quick Start Guide

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

SPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter

ITA100 MKII 100mW green DMX laser

ProEM -HS:1024BX3 FEATURES BENEFITS

User's Guide. Model W 3-in-1 Switching DC Power Supply

Spectrometer Visible Light Spectrometer V4.4

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

F-712.PM1 Optical Power Meter

Prizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications

OX 5022-CK OX 5042-CK

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

20 MHz/16-bit readout 61 fps rate at full-frame resolution. Use ROI/binning for hundreds of frames per second.

Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

Optical Fiber Assemblies

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Raman Spectrometer Installation Manual

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Getting Started. Here's how to get started using your Zip 250 drive: 1. Unpack the Zip 250 drive and accessories.

TSR 3DXP and TSR 6DXP User s Manual May 2011

SF10 SF10. Features: The SF10 laser altimeter is ideal for automated landings and precision hovering.

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

FluxGage. FluxGage. LED Luminaire Measurement System User Manual

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Click Desktop Kit. Click Desktop Kit

2.2. Facilities Requirements

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

HD Mini IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.2.0

Getting Started Instructions for the Access USB and Access 2 USB Probers

PicoVNA. USB vector network analyzer. Quick Start Guide

Quick Start Guide: Welcome to OceanView

Quick Start Manual. Color Image Scanner

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Blue Weapon Laser. User manual UK. Version 1.0

Single Photon Counting Module

Application Wavelength Range Type Principle Product. Color / VIS / NIR nm Tungsten Halogen Continuous AvaLight-HAL(-S)

Startup Guide C01

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Dahua HD Fixed-focal Pinhole Network Camera

SF30 SF30. The SF30 is a high speed, light weight laser rangefinder for mapping and obstacle detection by robotic vehicles such as UAVs.

High speed laser. altimeter for. accurate mapping. and obstacle. detection. Features: SF30 Accelerated laser rangefinder Product manual

OTO Photonics. Sidewinder TM Series Datasheet. Description

GV-RK1352 and GV-R1352 Card Reader

PRO-75 SERIES. User manual

SE800 Short Manual SENTECH Instruments GmbH

Red Tide USB650 Fiber Optic Spectrometer. Installation and Operation Manual Document Number RT

Spectro-115E TM and Spectro-115U TM Spectroelectrochemical System. Operator s Manual

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

TC100 Precision Thermocouple Calibrator

Quick Setup & Getting Started

Laserlyte-Flex Alignment System

NVR SERIES 4/8/16/24/32 - Channel Network Video Recorder V

RoHS COMPLIANT 2002/95/EC

PR3400 Series 1.4Mp USB Cameras Hardware Guide

A Global Laser Brand. Versatile Module

DPSS Laser. Quick Start Guide. What is in the box What does it do? How to build a setup Installation of required drivers...

1510A. MTI Instruments, Inc. 325 Washington Avenue Extension, Albany, New York USA Phone: (518) FAX: (518)

Single Photon Counting Module COUNT blue -Series

User Manual. 3KW/5KW PV Inverter

RA3211 PON optical power meter

Specifications, Installation, and Operating Instructions

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

PM Series Power Meter

External Triggering Options

OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

MAXIMA+ Series Rotary Level Indicator

ADC2000-PCI A/D Converter Operating Instructions

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

VDL-004. Miniature Manual Variable Optical Delay Line. User Guide

H704-42(H)(E), H704-42/1(H)(E)

Installing TAM Air Assistant Software TM

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

800 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)

ActiveSite. icolor Player. Product Guide

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Machine Vision Lyte-MV

XTM1250SA DIN rail three phase four wire LCD display energy meter

MAXIMA + Series ROTARY LEVEL CONTROL

Trigger high-speed, retro-reflective sensors for bottles. Dimensioned drawing

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

A803 INSTRUCTION MANUAL

Light-Source Mainframe

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Transcription:

RaySphere and RaySphere 1700 Description Solar Analysis System Quick Start Instructions RaySphere is a calibrated high-performance measurement device. It is designed for testing the spectral distribution of all types of Solar Simulators and for validating the simulator for the spectral match test in accordance with the international standard IEC 90604-9: Solar Simulator Performance Requirements. The RaySphere series of products consists of RaySphere and RaySphere 1700. They provide the following features: Intuitive graphical interface Graphical and table display of classification results by wavelength bin Output of actual spectra in mw/cm 2 /nm Output of actual measurement and triggering timing with +/-44 µs resolution Printable classification report RAYSPHERE-1700-01-201304 1

RaySphere contains one QE65000 spectrometer, while RaySphere 1700 contains two spectrometers (QE65000 and NIRQuest512), a trigger unit to control the measurement procedure and a hub. The trigger sources can be a flash from the solar simulator, an electrical trigger pulse (high level with +5 V or +24 V), or a measurement can be generated manually at any time. RaySphere software allows full control during the testing and generates a test report with the classification of the simulator. This document provides you with information for testing a solar simulator with your RaySphere or RaySphere 1700 product. Detailed information for the RaySphere and RaySphere 1700 are provided in the RaySphere Solar Analysis System Installation and Operation Manual. Parts Included The RaySphere package consists of the following items: Pelican case: The transport box for the complete RaySphere System RaySphere main body Power Supply Four Power Cables, one each for USA, Europe, UK, and Australia Power Supply Connection Cable SubD-type, 3-meter length USB cable (USB-CBL-1): Connects RaySphere to a computer s USB port (3-meter length) RaySphere CD: Contains RaySphere software and calibration files and manuals Software and Technical Resources CD: Contains software, operating instructions, and product information for all Ocean Optics software, spectrometers, and spectroscopic accessories. You need Adobe Acrobat Reader version 6.0 or higher to view these files (version 7.0 is included on the CD). Documentation is also available on our website at http://www.oceanoptics.com/technical/operatinginstructions.asp. Passwords: For any Ocean Optics software that you have purchased. Passwords are located on the back of the Software and Technical Resources CD jacket. Calibration documents Important Safety Notices 1. Read the instructions first to avoid any damages. 2. Store your RaySphere system at above -10 C and below 50 C to avoid any damages. 3. This is a calibrated measurement device. Handle the system with care. The calibration precision may be lost if any dust or other pollutant enters the integrating sphere. When the system is not in use, store it with a dust protector. When removing the dust protector, be sure to keep pollutants from entering the integrating sphere aperture. 4. Recalibration is recommended after one year of use, or sooner if the measurements do not seem to be accurate. More frequent recalibration may be needed of the RaySphere has suffered any heavy shocks or is being used in a dusty environment. 5. The RaySphere is heavy. Take care to keep it from falling. 2 RAYSPHERE-1700-01-201304

6. If the seal on the screws is broken, then the calibration is no longer valid. 7. Do not cover vents. 8. Do not cover the holes at the top of the RaySphere s main body. RaySphere and RaySphere 1700 Instructions 9. To ship the RaySphere, pack it in the Pelican case, which is optimized for transport. Hand carrying the RaySphere is recommended for all traveling. 10. Contact your Ocean Optics regional headquarters for questions about RaySphere. 11. Be sure to follow all safety instructions for your solar simulator. Installing Software Caution Install the software BEFORE connecting the spectrometer to your PC. The SpectraSuite software installs the drivers required for spectrometer installation. If you do not install SpectraSuite first, the system will not properly recognize the spectrometer. RaySphere includes special software for operating your RaySphere system. This software is located on the RaySphere CD. The installation instructions are included below. In addition, if you have purchased and are using SpectraSuite, follow the instructions in the SpectraSuite Spectrometer Operating Software Installation and Operation Manual for software installation instructions. Caution Do not run SpectraSuite and RaySphere software at the same time on the computer. Procedure To install RaySphere software from the RaySphere CD, 1. Close all other applications running on the computer. 2. Load the RaySphere CD. The CD contains the calibration data, fundamental settings and the software for operating the RaySphere on a 32-bit or 64-bit computer. 3. Select the Setup CD folder. 4. Select the installation file for either a 32- or 64-bit system. The setup process begins and the following screen appears: RAYSPHERE-1700-01-201304 3

5. Click the Install button. Then follow the prompts in the installation wizard. Note If the following screen appears during the installation, select Repair: 6. Click Close when the installation is completed. It is not necessary to restart your computer. 4 RAYSPHERE-1700-01-201304

Assembling RaySphere RaySphere and RaySphere 1700 Instructions Follow the steps below to set up your RaySphere for use. It is recommended to perform 3 spectrum recordings (and to excite 3 flashes) within 5 minutes and to use the data from the last flash for the validation and certificate. Procedure 1. Connect the power cable to the power supply. 2. Connect the RaySphere unit to the power supply with the SubD cable. 3. Switch on the power supply. 4. Connect the RaySphere to your computer using a USB cable. Caution Be sure to switch on the power supply before connecting the RaySphere to your computer. Your RaySphere is now ready to use after 20 minutes of warm-up time. Using RaySphere with a Flash Solar Simulator Procedure 1. Place the assembled RaySphere main body close to the test plane so that its aperture is centered in the middle of the test plane. 2. If you are using an electrical trigger signal, select the correct input level for trigger signal at the power supply, and apply the signal cable to the BNC-connector on the power supply. 3. Make sure that the RaySphere software has been installed on the computer you intend to use. 4. Switch on the RaySphere power supply. Caution Always be sure to switch on the power supply before connecting the RaySphere to your computer. 5. Connect RaySphere via USB cable with your computer. 6. Start the RaySphere software. 7. Press Load Config ( ) on the System tab to load your solar simulator configuration file. 8. Wait 20 minutes for RaySphere to reach the thermal equilibrium. Measure the dark spectrum again. RAYSPHERE-1700-01-201304 5

9. Press QE65000 ( ) and NIR ( ) in the Spectrometer tab. Use the opening dialog box for recording a dark spectrum measurement. 10. Press Start ( ) in the software interface. 11. Generate 5 single flashes with maximum speed of 1 Hz within 3 minutes. RaySphere records the data. 12. Select Save All ( ) in the RaySphere software. Include the serial number of the flasher in the name of the file. The test report is generated automatically. Using RaySphere with a Continuous Solar Simulator Procedure 1. Switch on the solar simulator. 3. Make sure that the RaySphere software has been installed on the computer you intend to use. 4. Switch on the RaySphere power supply. Caution Always be sure to switch on the power supply before connecting RaySphere to your computer. 5. Connect RaySphere via USB cable with your computer. 6. Start the RaySphere software. 7. Wait 20 minutes for RaySphere to reach thermal equilibrium. 8. Press Load Config ( ) on the System tab to load your solar simulator configuration file. 9. Cover the RaySphere aperture (you can use the dust protector). Take a dark spectrum measurement by pressing QE65000 ( ) and NIR ( ) in the Spectrometer tab. 10. Uncover the RaySphere aperture. 11. Place the assembled RaySphere main body close to the test plane so that its aperture is centered in the middle of the test plane. 12. Press Sample ( ) in the RaySphere software interface 5 times each second. The RaySphere records the data. 13. Select Save All ( ) in the RaySphere software. Include the serial number of the flasher in the name of the file. The test report is generated automatically. 6 RAYSPHERE-1700-01-201304

Validating the Test Results Check the following to be sure that you are collecting valid data: The RaySphere was allowed to warm up for at least 20 minutes before starting the test. No error or warning messages were received when the calibration file was loaded. The spectra recording was during the stable flash time phase. Check that all marks for Start and End of Recording in the Photocurrent graph are at a stable flash time. Specifications Specification Value Electrical: Input voltages Input frequency Power Overvoltage protection Fuse Trigger connection 90 164 VAC 47 63 Hz 75 W 110 130% of main output M1.6 A BNC connector Connector: SMA 905 Optical: Optical input power Wavelength range*: RaySphere RaySphere 1700 150 W to 2000 W 350 1100 nm 300 nm 1700 nm Optical Trigger: Trigger delay 0 160 ms Time resolution 0.87 µs Jitter 150 ns Internal time resolution 2.54 µs Electrical Trigger: Electrical trigger type High level Minimum high time Connector High level 5 V or 24 V (selected at the power supply. Galvanically isolated input.) 100 ns BNC RAYSPHERE-1700-01-201304 7

Specification Value Delays and Timing: Fixed internal delay*: NIRQuest QE65000 Internal delay External delay 1030 µs 768 µs Selectable in 500 ns increments. Maximum 65500 steps. 0 168 ms General: Operating temperature 15 C 33 C Storage temperature -10 C 45 C Dimensions (l x w x h) Weight RaySphere RaySphere 1700 USB Cable 30.7 cm x 23.5 cm x 6.6 cm 4.2 kg (main body) 5.7 kg (main body) No longer than 5 m *See the specific spectrometer manuals for more details Mounting Options for RaySphere Main Body and Mechnical Diagram The technical drawing shows the back side of the RaySphere main body. The system can be mounted at the indicated M6 rods only. WARNINGS Do not bend the system for tight mounting! Mounting on uneven surfaces may bend the RaySphere system. This may cause increased measurement uncertainties. 8 RAYSPHERE-1700-01-201304

RAYSPHERE-1700-01-201304 9

10 RAYSPHERE-1700-01-201304