USER GUIDE. EZ Switch TM 10/100/ /24-Port Gigabit Ethernet Plus Switch SMCGS1610/SMCGS2410

Similar documents
USER GUIDE. EZ Switch TM 10/100/ G Port Unmanaged Fast Ethernet Switch SMCFS2601

USER GUIDE. EZ Switch TM 10/100 16/24-Port Unmanaged Fast Ethernet Switches SMCFS1601/SMCFS2401

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

24-Port Gigabit Ethernet Switches

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

MDI/MDIX) FEP-32005T-2

FSW-1610TX FSW-2410TX

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch

GEU-0520 GEU QIG Manual

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

FCC Certifications. CE Mark Warning

LevelOne. User Manual GSW-1656/GSW /24-Port Gigabit Switch w/ 4-Port SFP. Version

FCC Certifications. CE Mark Warning

16/24-Port Gigabit Desktop Switch

D-Link Switch User Manual. Table of Contents

GSW User Manual. 4-Port TP + 1-Port SFP Gigabit Ethernet Switch. Ver

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

Ether-FSH2400C 24-port 10/100Base-TX Switch

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

Gigacore 8-Port 10/100/1000Mbps Desktop Switch

GEU Port Gigabit Switch

FSW-1609TFX FSW-2409TFX

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

GSW-2453 Gigabit Chassis switch. User Guide

pakedgedevice&software inc.

5-Port 1000BASE-T. Gigabit Ethernet Switch. User s Guide

8 ports 10/100/1000Mbps. Gigabit Ethernet Desktop Switch Layer 2 USER S GUIDE

4. 4 x Foot Pads 5. Rack-Mount Kit

SWITCH, 24 POE PORTS ART. IPSWP240A

DynaGST/2402G USER S MANUAL

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Chapter 1 Product Introduction

DynaGST/2402G. 24 Port 10/100/1000Base-T Gigabit Ethernet Switch with two SFP (mini) GBIC Slots PN: GEP-33224T USER S MANUAL

User Guide. FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch. FSW-1641TX 16 port 10/100Base-TX Web Smart Switch

LP-SGW2404FP 24 Copper PoE + 4 Fiber Gigabit Managed Switch

16/24 Port Desktop & Rack-mountable Gigabit Ethernet Switch

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

The RFS-105 / RFS-108 is a high-performance Fast Ethernet switch, with all ports capable of 10 or 100Mbps auto-negotiation operation.

16 / 24 Ports Fast Ethernet Switches 19 Rackmount Quick Installation Guide

HES-3106-PLUS SERIES

Gigabit Desktop. manual Models & Model shown: INT / UM

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

LevelOne FSW PoE Fast Ethernet Switch User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

SWITCH RC-415/RC-416 USER S Manual

PM3020FSNL/PM3028FSNL 16-Port 10/100Mbps+2 Gigabit TP/SFP Combo PoE Switch 24-Port 10/100Mbps+2 Gigabit TP/SFP Combo PoE Switch

24-Port 10/100Mbps + 2-Port. Gigabit Ethernet Switch FGSW User s Manual

Quick Install Guide AMS-4424P AV Series 26-Port Gigabit Stackable PoE+ L2/L3 Managed Switch

Signamax Connectivity Systems Industrial 10/100BASE-TX Ethernet Extender

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

VAC 50/60Hz Power Adapter

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

5/8 Port Gigabit Ethernet Switch

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

LevelOne. User s Guide EHU-0507T EHU-0507TB EHU-0807T EHU-0907TB. 5/8/9 Port PalmCon 10M HUB

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

ST-POEAF-S16-RM. 16 port PoE switch. User Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

Rubber Foot Pads. Rackmount Kit VAC 50/60Hz Power Adapter

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

FWRIII-2105 SERIES. 4 ports 10/100Mbps RJ-45; built-in IEEE802.11n WiFi and 1 port 100Mbps SFP slot uplink Residential Gateway. Residential Gateway

Business Networking Solution. Installation Guide. 16/24-Port Gigabit Easy Smart Switch TL-SG1016DE/TL-SG1024DE

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

H3C S1016/1024 Ethernet Switch User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

100 - SERIES NETWORK SWITCHES Installation Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

KFC-200. Installation Guide

Quick Start Guide. Physical Description. The Port Status LEDs

EKI-2528PAI 8-port Industrial Unmanaged Ethernet Switch with 4-port PoE. User Manual

Conventions. Preface. Technical Support & Helpline. Install Guide TNDS-9000P 9-Port Gigabit PoE Switch Series

5/8-Port 10/100Mbps Fast Ethernet Desktop Switch

48-port 10/100TX + 1 SFP Gigabit Port and 1 10/100/1000BASET Port Unmanaged Switch MIL-S4800. User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

8 Port Gigabit Ethernet Switch User Manual (P/N: 41NE-G3800UD0-A00)

2-Port Wireless Access Controller EWS4502. Installation Guide.

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

GN-GT5D. Gigabit Ethernet Switch. User Guide. Rev.1.0 First Edition

LNX-0702G-SFP Series

PCI Express Gigabit Ethernet Adapter. User's Guide

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Introduction... 3 Gigabit Ethernet Technology... 4 Switching Technology... 4 Features Package Contents... 6

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

DES-1016R+/DES-1024R+ 10/100 Fast Ethernet Switch

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Quick Install Guide. Compex 8 Port Dual Speed Fast Ethernet Switch PS2208B. Version 1.1C

Industrial 8-Port 10/100TX Compact Ethernet Switch

Transcription:

USER GUIDE EZ Switch TM 10/100/1000 16/24-Port Gigabit Ethernet Plus Switch SMCGS1610/SMCGS2410

EZ Switch TM 10/100/1000 User Guide From SMC s EZ line of low-cost workgroup LAN solutions No. 1, Creation Road III, Hsinchu Science Park, 30077, Taiwan, R.O.C. TEL: +886 3 5638888 Fax: +886 3 6686111 SMCGS1610/SMCGS2410 E112013-AP-R02

Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice. Copyright 2013 by SMC Networks, Inc. No. 1, Creation Road III, Hsinchu Science Park, 30077, Taiwan, R.O.C. All rights reserved Trademarks: SMC is a registered trademark; and EZ Switch, TigerStack and TigerSwitch are trademarks of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.

WARRANTY AND PRODUCT REGISTRATION To register SMC products and to review the detailed warranty statement, please refer to the Support Section of the SMC Website at http://www.smc.com. 4

COMPLIANCES AND SAFETY STATEMENTS FCC - CLASS A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. CE MARK DECLARATION OF CONFORMANCE FOR EMI AND SAFETY (EEC) This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. Declaration of Conformity (DoC) can be obtained from www.smc.com -> support -> download 5

ABOUT THIS GUIDE PURPOSE This guide details the hardware features of the switch, including the physical and performance-related characteristics, and how to install the switch. AUDIENCE The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks). CONVENTIONS The following conventions are used throughout this guide to show information: NOTE: Emphasizes important information or calls your attention to related features or instructions. CAUTION: Alerts you to a potential hazard that could cause loss of data, or damage the system or equipment. WARNING: Alerts you to a potential hazard that could cause personal injury. REVISION HISTORY This section summarizes the changes in each revision of this guide. NOVEMBER 2013 REVISION This is the second revision of this guide. It includes the following change: Updated the front panel image. 6

ABOUT THIS GUIDE OCTOBER 2013 REVISION This is the first revision of this guide. 7

CONTENTS WARRANTY AND PRODUCT REGISTRATION 4 COMPLIANCES AND SAFETY STATEMENTS 5 ABOUT THIS GUIDE 6 CONTENTS 8 1 INTRODUCTION 10 Overview 10 Features 11 2 HARDWARE DESCRIPTION 15 Front Panel 15 Port and System Status LEDs 15 RJ-45 Ports 16 Smart Button 16 Rear Panel 17 AC Power Socket 17 3 INSTALLING THE SWITCH 18 Package Contents 18 Precautions 19 Safety Requirements 19 Location Requirements 19 Installation 20 Desktop Installation 20 Rack Installation 21 How to Connect to AC Power 22 Powering On 23 8

CONTENTS Connecting Network Devices 24 Cabling Guidelines 24 Connecting to PCs, Servers, Hubs and Switches 24 A TROUBLESHOOTING 25 Diagnosing Switch Indicators 25 The Power LED is Off 25 The Link/Act LED is Off when a Device is Connected to the Corresponding Port 25 Power and Cooling Problems 25 Installation 26 B SPECIFICATIONS 27 Physical Characteristics 27 9

1 INTRODUCTION OVERVIEW The SMCGS1610 and SMCGS2410 are the first available unmanaged switches that can be transformed into a smart switch with the use of a single button. DHCP prevention combined with loopback detection and prevention, improves the network environment and reduces network maintenance costs. The switches also provide DoS attack protection, minimizing virus attacks and increasing network uptime. The SMCGS1610 and SMCGS2410 switches feature a non-blocking switching architecture that forwards and filters packets at full wire-speed for maximum throughput. The switches are compatible with all 10, 100, and 1000 Mbps Ethernet devices because they are standard-based. The switches protect your existing network investments while providing you with a straightforward migration path to faster Gigabit speeds. The SMCGS1610 and SMCGS2410 switches are plug-and-play devices; no configuration is required. Auto MDI/MDI-X cable detection on all ports eliminates the need for crossover cables. Each port can be used as an end-node or uplink port, and any port can be simply plugged into a server, hub, router, or switch, using straight-through or crossover cable. Diagnostic LEDs, which display link status and activity, allow you to quickly detect and correct problems on the network. 10

CHAPTER 1 Introduction Overview FEATURES SMART BUTTON The SMCGS1610 and SMCGS2410 are the first available switches that use a single button to give your unmanaged switch smart switch capability. Figure 1: Push to Smart Button DHCP PREVENTION DHCP Prevention protects your company s network DHCP Server. When the Smart button is pressed in, it enables a DHCP port restriction feature. The DHCP Prevention feature restricts the DHCP server to the DHCP Port only (port 1). If, on the remaining ports, other DHCP servers are added to the network, the switch will prevent them providing DHCP service. Figure 2: DHCP Prevention 11

CHAPTER 1 Introduction Overview LOOPBACK DETECTION AND PREVENTION When a loop occurs at a port, the switch will Block the loop port, automatically protecting the switch. Flash the port LED twice every second. Turn the Loop LED on red. When the loop clears the port LED will cease flashing and the Loop LED will turn off. Figure 3: Loopback Detection and Prevention IGMP SNOOPING V1/V2 The switches support IGMP snooping v1/v2, improving multicast services such as video streaming, resulting in smoother video reproduction. 12

CHAPTER 1 Introduction Overview DOS ATTACK PROTECTION The switches can detect multiple DOS attack scenarios and initiate appropriate protection algorithms. DOS attack scenarios that can be protected against are: DoS - Land Attack DoS - IP Spoofing Attack DoS - TCP SYN Attack DoS - TCP NULL scan DoS Attack EEE SUPPORT The switches support green 802.3az Energy-Efficient Ethernet to reduce power consumption and energy costs. FAN-LESS DESIGN The switches utilize a fan-less design for a noise-free operation that will not disturb anyone nearby. IEEE 802.1P QOS When the switch receives a frame tagged with an 802.1p QoS priority tag, it is placed is an appropriate priority queue. OTHER FEATURES Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3ab standards. 16/24 10/100/1000 Mbps auto-sensing RJ-45 ports supporting Auto-MDI/ MDIX. All ports support full/half-duplex transfer mode for 10/100 Mbps and fullduplex transfer mode for 1000 Mbps. Supports IEEE 802.3x flow control for full-duplex mode and backpressure for half-duplex transfer mode. Non-blocking switching architecture that forwards and filters packets at full wire-speed for maximum throughput. Supports MAC address auto-learning and auto-aging. Supports IEEE 802.1p QoS. 13

CHAPTER 1 Introduction Overview LED indicators for displaying power, link, speed, activity and loop disabled. Desktop and rack-mountable steel case. Internal power supply. 14

2 HARDWARE DESCRIPTION This chapter describes the front panel, rear panel, and LED indicators of the switch. The SMCGS1610 and SMCGS2410 only differ in the number of ports. All figures in this guide are of the SMCGS2401. FRONT PANEL The front panel of SMCGS2401 consists of switch LED indicators, 24 10/100/ 1000 Mbps RJ-45 ports, and a Smart button. Figure 4: SMCGS2401 Switch Front Panel PORT AND SYSTEM STATUS LEDS The switches include a display panel for key system and port indications that simplify installation and network troubleshooting. The LEDs, which are located on the front panel, are described in the following table. Table 1: System and Port Status LEDs LED Condition Status Power On Green The internal power supply is operating normally. Off The switch has no power connected. 15

CHAPTER 2 Hardware Description Front Panel Table 1: System and Port Status LEDs (Continued) LED Condition Status Loop On Red The switch has detected a loop condition and disabled the appropriate port. When the loop clears, the LED will turn off. Off The switch has not detected a loop condition or the current loop condition has cleared. 1 to 24 On/Blinking Green Port has established a valid 100 Mbps connection. Blinking indicates activity. On/Blinking Amber Flashing Amber (two flashes per second) Off Port has established a valid 1000 Mbps connection. Blinking indicates activity. The port is in a looped state and has been disabled. When the loop clears, the port LED will cease flashing. There is no valid link on the port. RJ-45 PORTS The switch contains 16/24 1000BASE-T RJ-45 ports. All ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs. Each of these ports support auto-negotiation, so the optimum transmission mode (half or full duplex), and data rate (10, 100, or 1000 Mbps) is selected automatically. Each port also supports IEEE 802.3x auto-negotiation of flow control, so the switch can automatically prevent port buffers from becoming saturated. SMART BUTTON When the Smart button is engaged, the unmanaged switch automatically initiates smart switch functionality. The Smart button enables the following functions: DHCP Prevention - restricts installation of a DHCP server to port 1 only, preventing rogue DOS servers from being connected to the network. Loopback Detection and Prevention - The switch checks all ports for a loopback condition every 2 seconds. Upon detection of a loopback condition, the switch blocks the affected port s traffic for 3 seconds and flashes the 16

CHAPTER 2 Hardware Description Rear Panel port LED twice every second. The Loop LED will also turn on when a loop condition exists. When the loop condition has been cleared, the Loop LED will turn off and the port LED will stop flashing. IGMP Snooping V1/V2 - With IGMP snooping turned on, multicast traffic is filtered from ports that do not need the multicast packets, thus freeing up switch bandwidth. REAR PANEL The rear panel of the switch features a power socket. Figure 5: SMCGS2401 Switch Rear Panel AC POWER SOCKET Connect the female connector of the power cord here, and the male connector to the AC power outlet. Note that the socket includes the PE (Protective Earth) pole to connect the switch to ground through an AC power cord. Make sure the voltage of the power supply meets the requirement of the input voltage and use an appropriate AC power outlet that includes a Protective Earth pole. 17

3 INSTALLING THE SWITCH Before installing the switch, verify that you have all the items listed under Package Contents. If any of the items are missing or damaged, contact your local SMC distributor. Also be sure you have all the necessary tools and cabling before installing the switch. PACKAGE CONTENTS The following contents should be found in your package: One SMCGS1610 or SMCGS2410 Switch Power Cord This User Guide Rackmount Kit Quick Installation Guide SMC Warranty Card Four Rubber Foot Pads NOTE: Make sure that the package contains the above items. If any of the listed items are damaged or missing, please contact your distributor. CAUTION: Do not plug a phone jack connector in the RJ-45 port. This may damage this device. Les raccordeurs ne sont pas utilisé pour le système téléphonique! 18

CHAPTER 3 Installing the Switch Precautions PRECAUTIONS To ensure a long-term and stable performance of the switch, pay attention to the following before installation. SAFETY REQUIREMENTS Before cleaning the switch, disconnect the power supply. Do not clean the switch using a wet cloth, and never use any other liquid for cleaning. Take waterproof measures during storage, transportation and operation of the equipment. Use only the power cord provided with the switch. Make sure the voltage of the power supply meets the requirement of the input voltage of the switch. Do not push any objects into the openings of the switch. Ensure the vent holes are well ventilated and unblocked. Do not open or remove the cover of the switch. LOCATION REQUIREMENTS When you choose a location for the switch, follow these guidelines: Install the switch on a flat and stable surface that can support the entire weight of the switch with all fittings. Locate the switch far from strong electromagnetic field generators (such as motors), vibration, dust, and direct exposure to sunlight. To ensure adequate air flow around the switch. At least 10 cm (4 inches) of space at the front and rear of the switch is needed for ventilation. Make sure that the switch will be accessible and that the cables can be easily connected. 19

CHAPTER 3 Installing the Switch Installation Position the switch away from water and moisture sources, be sure to provide an acceptable temperature and humidity operating environment. INSTALLATION This switch can be either installed in a standard 19-inch mountable rack or located on a desktop. CAUTION: Please unplug the power cord before installing or removing the switch. DESKTOP INSTALLATION To install the switch on the desktop, follow these steps: 1. Set the switch on a flat surface strong enough to support the entire weight of the switch with all fittings. 2. Remove the adhesive backing papers from the rubber feet. 3. Turn the switch over and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the switch. 20

CHAPTER 3 Installing the Switch Installation Figure 6: Attaching Rubber Feet 4. Upturn the switch and set in the desired location, making sure there is enough ventilation space on all sides for proper air flow 5. Connect the switch to a power source with the provided power cord. See Powering On on page 23. CAUTION: Avoid placing anything heavy on the switch. RACK INSTALLATION To install the switch in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Secure the supplied rack-mounting brackets to each side of the switch with supplied screws, as illustrated in the following figure. 21

CHAPTER 3 Installing the Switch Installation Figure 7: Attaching Brackets 2. Use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure. Figure 8: Mounting the Switch 3. Connect the switch to a power source with the provided power cord. See Powering On on page 23. HOW TO CONNECT TO AC POWER To supply AC power to the switch, first verify that the external AC power supply can provide 100 to 240 VAC, 50-60 Hz. 22

CHAPTER 3 Installing the Switch Installation To connect the switch to a power source: 1. Plug the power cord into a grounded, 3-pin, AC power source. Figure 9: AC Power Cord and Power Socket 2. Insert the plug on the other end of the power cord directly into the AC input socket on the back of the switch. NOTE: Your country s AC power outlet standards may not match the power plug of the included AC power cord, you may need to change the AC power cord. You must use a cord set that has been approved for the socket type in your country. 3. Check the LED indicators on the switch front panel as the unit is powered on to verify that power is being received. If not, recheck the power cord connections at the AC supply source and back panel power input connector. POWERING ON The SMCGS1610 and SMCGS2410 switches are powered by connecting to an AC power supply using a power cord. When powering on the switch, it automatically initializes and the LED indicators respond as follows: 23

CHAPTER 3 Installing the Switch Connecting Network Devices 1. All of the LED indicators flash momentarily for one second, which represents a resetting of the system. 2. The Power LED indicator turns on green. CONNECTING NETWORK DEVICES The switches are designed to be connected to 10, 100, or 1000 Mbps network cards in PCs and servers, as well as to other switches and hubs. CABLING GUIDELINES The RJ-45 ports on the switch support automatic MDI/MDI-X pinout configuration, so you can use standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches, routers, or hubs). Each device requires an unshielded twisted-pair (UTP) cable with RJ-45 connectors at both ends. Us Category 5 or better for 100BASE-TX connections, and Category 3 or better for 10BASE-T connections. CONNECTING TO PCS, SERVERS, HUBS AND SWITCHES 1. Attach one end of a twisted-pair cable segment to the device s RJ-45 connector. 2. Attach the other end of the cable segment to an available port on the switch. Make sure each twisted pair cable does not exceed 100 meters (328 ft) in length. 3. As each connection is made, the relevant port LED (on the switch) corresponding to each port will turn on green to indicate that the connection is valid. 24

A TROUBLESHOOTING DIAGNOSING SWITCH INDICATORS THE POWER LED IS OFF Make sure the AC power cord is connected to the switch and power source properly. Make sure the power source is ON. THE LINK/ACT LED IS OFF WHEN A DEVICE IS CONNECTED TO THE CORRESPONDING PORT Make sure that the cable connectors are firmly plugged into the switch and the device. Make sure the connected device is turned on and working properly. The cable must be less than 100 meters long (328 feet). Check the port on the attached device and cable connections for possible defects. Replace the defective cable if necessary. POWER AND COOLING PROBLEMS If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet. If you still cannot isolate the problem, the internal power supply may be defective. 25

APPENDIX A Troubleshooting Installation INSTALLATION Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly. 26

B SPECIFICATIONS PHYSICAL CHARACTERISTICS STANDARDS IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3ab 1000BASE-T TOPOLOGY Star PROTOCOL CSMA/CD DATA TRANSFER RATE Ethernet: 10 Mbps (half/full duplex) Fast Ethernet: 100 Mbps (half/full duplex) Gigabit Ethernet: 1000 Mbps (full duplex) NETWORK MEDIA (CABLE) 10BASE-T: UTP Category 3, 4, 5 cable (maximum 100 m) EIA/TIA-568 100 STP (maximum 100 m) 100BASE-TX: UTP Category 5, 5e cable (maximum 100 m) EIA/TIA-568 100 STP (maximum 100 m) 1000BASE-T: UTP Category 5e, 6 cable (maximum 100 m) EIA/TIA-568 100 STP (maximum 100 m) NUMBER OF PORTS 16/24 10/100/1000 Mbps auto-negotiation RJ-45 ports 27

APPENDIX B Specifications Physical Characteristics LED INDICATORS POWER, LOOP, Link/Act, 1000 Mbps TRANSFER METHOD Store-and-Forward MAC ADDRESS LEARNING Automatically learning, automatically aging FRAME FILTER RATE 10BASE-T: 14881 pps/port 100BASE-TX: 148810 pps/port 1000BASE-T: 1488095 pps/port FRAME FORWARD RATE 10BASE-T: 14881 pps/port 100BASE-TX: 148810 pps/port 1000BASE-T: 1488100 pps/port SWITCHING DATABASE 16K MAC address entries BUFFER MEMORY Internal Memory: 64 KB Flash: 2 MB SWITCHING CAPACITY SMCGS1610: 32 Gbps SMCGS2410: 48 Gbps POWER ADAPTER SMCG1601/2401: 100 ~240 V, 50-60 Hz 28

APPENDIX B Specifications Physical Characteristics DIMENSIONS SMCGS1610: 28.0 x 18.0 x 4.4 cm (11.0 x 7.1 x 1.73 in.) SMCGS2410: 28.0 x 18.0 x 4.4 cm (11.0 x 7.1 x 1.73 in.) WEIGHT SMCGS1610: 1.54 Kg (3.54 lbs) SMCGS2410: 1.66 Kg (3.65 lbs) FEATURE Smart Button DHCP Prevention Loopback Detection/Prevention IGMP Snooping v1/v2 DoS Attack Protection Energy Efficient Ethernet IEEE P802.3az IEEE 802.1p QoS Jumbo Frames: 9216 Bytes TEMPERATURE Operating: 0 to 40 C (32 to 104 F) Storage: -40 to 70 C (-40 to 158 F) HUMIDITY Operating: 10% to 90% (non-condensing) Storage: 10% to 90% (non-condensing) ELECTROMAGNETIC COMPATIBILITY CE FCC BSMI IMMUNITY EN55024 IEC61000-4/2/3/4/5/6/8/11 29

APPENDIX B Specifications Physical Characteristics EMISSIONS FCC Class A, EN55022/EN61000-3-2/3 SAFETY LVD (EN60950) 30

Headquarters No. 1, Creation Rd. III Hsinchu Science Park Taiwan 30077 Tel: +886 3 563 8888 Fax: +886 3 668 6111 Singapore 15 Enggor Street #10-04, Realty Centre Singapore 079716 Tel: +65-63387667 Fax: +65-63387767 su www.smc.com www.smc-asis.com www.smcnetworks.co.kr Declaration of Conformity (DoC) can be obtained from www.smc.com -> support -> download SMCGS1610/SMCGS2410 www.smc.com 150200062800A R02 20 Mason Irvine, CA 92618 Phn: 949-679-8000 www.smc.com