Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

Similar documents
Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Cluster Controller. Impro (CCM) Cluster Controller Module INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL

UniScan. Impro UniScan Controller INSTALLATION MANUAL

Amano Nexus Lite Controller INSTALLATION MANUAL

MULTI-DISCIPLINE READERS. ImproX Multi-discipline Readers INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: MDR GB-XX MDK GB-XX

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Installing Sentor. Hardware Installation

DC Outdoor Power Supply/Chargers

Installation manual CF8-W-Disp-AL

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

Digital Keypad Introduction

A-100G6 - Basic frame assembly diagram

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

2-Way Wireless I/O Expander Installation Guide

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

IS-DM220/IR/HB IS-DM220

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Arecont Vision MegaDome 2 Installation Manual (DN Models Only)

LaserLyte-Flex Red & Green Alignment System

Connecting a Cisco Input Module

Installing Keypad and Backplate

DIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

sonnen Installation Practical

PCL channel Isolated Digital I/O Card

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

Cardax Prox Plus Mifare Reader

C5S120 Installation and Connection Guide

16-Way Input 48-Way Output Card

Lightning Stitch Assembly

TruPortal Dual Door Interface Module Quick Reference

SITOP in the SIMATIC Design

Temperature Switches

Multitronic. Technical data

INSTALLATION INSTRUCTIONS

Signal Tower KombiSIGN 50

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

TruPortal Output Expansion Board Quick Reference

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Advantages of a Full Featured 700 Series Relay

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

BA684DF-P PROFIBUS PA Field mounting Fieldbus Display

TPG-5. User Instructions. Tone Generator. Tone Pulse Generator

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

The Power Generation Display Unit is available in two sizes as described in the following table:

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Description. Green. Red. Orange

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

PowerView Model PV485. Installation Manual Section 78

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

6222 Two Door Module Technical Operations Manual

XL/BW/BRW-2 Indicators USER'S MANUAL

Display Panel BAT 100 LSN. en Operation Guide

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

2M IR Mini Dome Quick Installation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

VAL-62. Fieldbus modules FD67 Series Input, output and analog modules with IP67 ingress protection. Valves

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

Vorne Industries. 87/001 RS-485 Communications Board User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Basketball Shot Clock Set LX2180 Manual

RTD-W Installation Instructions

Device manual AS-i PowerSwitch ZB0028 ZB0040

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

TRC-190 User s Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

GV-EL124S Electric Strike

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Connecting a Cisco Reader Module

Surface-Mounting Product Ranges

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Communications & Networking

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

Protected VARAN Digital Mixed Module PVDM 086

Special-Purpose Proximity Sensor E2C

Product Data Sheet. Hochiki 8 Way I/O Card. Features

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Installation Instructions

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

TCNM-ACBB1 Installation Manual

Model HM-535 Power Supply Installation and Service Instructions

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

TRC-190 User s Manual

PS/IO Circuit Board Retrofit

Conveyor Belt Alignment Switches from IDEM

Transcription:

COMPONENT CODES: HMI700-1-0-NN-XX HMI701-1-0-NN-XX Digital I/O Module Impro (DIO) Digital I/O Module Specifications INSTALLATION MANUAL The DIO is a Cluster Expansion Module that works in conjunction with an Impro (CCM) Cluster Controller Module; offering eight Digital Inputs and 4 output relays. Working Environment Plastic Housing... PCB Card for IPS enclosure... Power Designed to work in an indoor (dry) environment similar to IP20, the Module is not sealed against water. Designed to work in an indoor (dry) environment similar to IP20, the Card is not sealed against water. Input Voltage... 12 V DC to 15 V DC, polarity protected. Power Requirements Current (ma) Power (W) Input Voltage 12 V DC, Relays off... 50 0.6 Input Voltage 12 V DC with all 4 relays activated... 230 2.7 Relay Power Requirements... ~0.4 W per Relay in use.

Communication with the Cluster Controller Module Direct Communications When the DIO is clustered (plugged side-byside) directly into the Cluster Controller Module, or into an existing Cluster, or installed in an IPS enclosure. Electrical Interface... Propriety Cluster-Bus Baud Rate... 115 200 Encryption... AES Encryption S-Bus Device Port Electrical Interface... Propriety S-Bus Baud Rate... 9600 Encryption... AES Encryption Digital Inputs Type... Detection Resistance Range... Protection Range... 8 Dry-contact inputs with End-of-line (EOL) Sensing. < 2 kω. +15 V continuous. Figure 1: End-of-Line (EOL) Sensing Circuit HMI300-0-0-GB-00 March 2014 Page 2

Relays Relay Output... Relay Contact Ratings... Operations... 4 Independent, single-pole, double-throw (SPDT) Relays, each with NO, COM and NC contacts. 10 A at 28 V DC, 5 A at 220 V AC, 12 A at 120 V AC. 100 000 Minimum. LED Status and Diagnostic Indicators Status LED (RED) Supply Voltage Status... Upgrade Mode... Communications Failure... Data LED (GREEN) Digital Inputs (1-8)... Relays (1-4)... Off when supply voltage is too high, or too low Flashing at a steady rate during upgrade Two brief flashes, repeating Flashing Green during communication Continuous Green on detected contact closure Continuous Red on activation of the Relay HMI300-0-0-GB-00 March 2014 Page 3

INSTALLATION INFORMATION Accessories CAUTION: DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max clamping) with mains power applications. Find the following when unpacking the DIO: Plastic Cluster Module Housing (HMI700) An Impro (DIO) Digital I/O Module is supplied in a Customisable Black, ABS Plastic housing with the following features/components: Housing, consisting of a Base, a Cover and a selection of Cable Entry Gland Plates. The Housing Base has: Two slots to hold the User-Selectable Cable Entry Plates Six knock-out Cable Entry Points Four Drill-out Cable Entry Points The Housing Cover and Base are held together with two Allen Head Screws (M4 x 10 mm) through the cover of the housing. Five Ziploc bags, containing the following: Four Stand-Offs (for spacing the DIO away from the mounting surface) and two Cluster Connector Covers (for closing off the cluster connectors when not in use.) Four Metal-Oxide Varistors 25 Vrms, 500 A, 77 V max clamping. A 2mm Allen Key and a spare Hex Head Screw Two extra gland plates An extra Fixed Address Label, for installation site mapping NOTE: The installer needs to obtain fasteners (< 5 mm Diameter to fit through the supplied Stand-Offs) that are suitable for securing the Module to the mounting surface these are NOT supplied in the kit. PCB Card for IPS Housing (HMI701) Included in the packaging is: Impro Digital I/O PCB Card on a Base Plate. An extra Fixed Address Label, for installation site mapping Four Metal-Oxide Varistors 25 Vrms, 500 A max clamping HMI300-0-0-GB-00 March 2014 Page 4

General Remember the following when installing the Digital I/O Module: Clustering Clustering allows for the easy addition or replacement of Modules, it saves on wiring and requires only one DC Power Supply connection for the Cluster. The following applies: The DIO may be plugged directly into its associated Cluster Controller Module, or into an existing Cluster consisting of a Cluster Controller Module and other Expansion Modules. No more than eight Expansion Modules can be clustered with their associated Cluster Controller Module. The DIO is powered and controlled via its Cluster Connector. EARTH Connection Connect the Impro DIO ( ETH Terminal) to a good EARTH point. Mains EARTH can be used, but electrical noise may exist. Arc Suppression Snubber devices are recommended for EMF Flyback and Arc Suppression when driving an inductive load with the Relay, see Figure 2. Figure 2: EMF Flyback and Arc Suppression Blank Space HMI300-0-0-GB-00 March 2014 Page 5

Mounting the Impro (DIO) Digital I/O Module CAUTION: Make certain that you mount the DIO on a vibration-free surface. NOTE: The DIO can be mounted onto virtually any surface including metal. Clustering Provided there are less than eight other Expansion Modules already clustered with the Cluster Controller Module, you may add the DIO to an existing Cluster: Remove the Housing Cover from the DIO and plug the DIO into the Cluster Socket on the right hand side of the Cluster Controller or that of the outermost Expansion Module in the cluster. Holding the DIO square against its neighbouring Module, mark the mounting hole locations through the mounting holes in the back of the Housing Base. Remove the DIO, drill the mounting holes. Use the plastic Stand-Offs to provide space for cables behind the cluster, or if the other modules in the Cluster are already mounted with stand-offs. Mount the DIO Housing Base firmly to the mounting surface using fasteners (not included) appropriate for the mounting surface material. Select the gland plates that best suit the installation and/or knock out the cable entry points as needed. Connect the digital inputs and the relay terminals as necessary for the installation Commission the DIO via the menu options on the Access Control Application. Replace the DIO Housing Cover and fasten closed with the two Allen head screws provided. Blank Space HMI300-0-0-GB-00 March 2014 Page 6

Remote Mounting When it is advantageous to mount a DIO some distance from the Cluster Controller Module, the DIO may be connected to the Cluster Controller Module using an S-Bus cable up to a maximum of 150 m (490 ft.) long. The procedure is as follows: Check to see how many other Device Addresses are already connected to the S-Bus Host D Terminal of the Cluster Controller Module. No more than eight Device Addresses should be connected to an S-Bus. Obtain a suitable Isolated DC Power supply to power the DIO and any magnetic locks, etc., that may be connected to the DIO. Remove the Housing Cover from the DIO and try the DIO against the proposed mounting surface, considering accessibility, routing of cables, the visibility of the LEDs and the possibility of adding further hardware in any future expansion of the system. Secure the DIO Housing Base to the mounting surface, using suitable screws and wall plugs, nuts and bolts or rivets. Use the Stand-Offs if rear clearance will assist for cable entry or coping with an uneven mounting surface. Select the gland plates and Quick Click Glands that best suit the installation and/or knock out the cable entry points as needed. Connect the digital inputs and relay terminals as necessary for the installation. Power up the DIO and its peripherals Replace the DIO Housing Cover and fasten closed with the two Allen head screws provided. Blank Space HMI300-0-0-GB-00 March 2014 Page 7

ELECTRICAL CONNECTIONS Key Component Positions Figure 3: Key Component Positions HMI300-0-0-GB-00 March 2014 Page 8

Connecting to a clustered Digital I/O Module Figure 4 shows a detailed electrical connection diagram for the (Clustered) DIO. Figure 4: Typical (Clustered) DIO Electrical Connections NOTE: * Refer to Figure 2 for Arc Suppression details. (See further Notes on the next page) HMI300-0-0-GB-00 March 2014 Page 9

NOTE: Figure 4 shows typical connections to the DIO when clustered with its Cluster Controller Module (Models XYZ930 and XYZ931) The 8 digital inputs and the logic driving the 4 relays are configurable from within the Access Portal Software. Note: Figure 4 doesn t show the end-of-line resistors on the Digital Input Circuits - See Figure 1 (on page 2) for the correct placement of the 1kΩ EOL Resistors. BLANK SPACE HMI300-0-0-GB-00 March 2014 Page 10

Connecting to a remotely mounted Digital I/O Module Figure 5 shows a detailed electrical connection diagram for the remotely installed DIO, which needs an isolated DC power source and an S-Bus connection with its Cluster Controller Module. (End-of-line resistors are not shown, see page 2 for EOL details.) Figure 5: Typical Remotely Mounted DIO Electrical Connections HMI300-0-0-GB-00 March 2014 Page 11

DIO Address Information Fixed Address Label Once the installation is complete, do the following: Sketch a rough site plan. Attach the loose additional Fixed Address Label, packaged with the DIO, in the position of the DIO on the sketched site plan. When the system installation is complete and all the modules are represented on the site plan by their Fixed Address Labels, file the site plan for future reference. USER NOTES HMI300-0-0-GB-00 March 2014 Page 12

USER NOTES HMI300-0-0-GB-00 March 2014 Page 13

USER NOTES HMI300-0-0-GB-00 March 2014 Page 14

USER NOTES HMI300-0-0-GB-00 March 2014 Page 15

GUARANTEE OR WARRANTY CAUTION: We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net. This manual is applicable to the Impro (DIO) Digital I/O Module, Product Order Codes: HMI900-0-0-GB-XX, HMI901-0-0-GB-XX (The last two digits of the Impro stock code indicate the issue status of the product). HMI300-0-0-GB-00 Issue 01 March 2014 Impro\Access Portal\ Digital IO Module\English Manuals\LATEST ISSUE\ condio-insm-en-01.docx HMI300-0-0-GB-00 March 2014 Page 16