MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

Similar documents
MODEL: 43DV2. Digital Panel Meters 43 Series

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

For Super-mini Signal Conditioners with Display M1E-UNIT USERS MANUAL

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Digital Indicator DS 48/24 E

MIC-2 MKII, Multi-instrument DATA SHEET

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

DINALOG A 144 x 36 A1400 Light-Strip Indicator

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: WL40EW2F. Wireless I/O WL40F Series

MODEL: GR8-EM. Communication Adaptor GR8 Series

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no:

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402)

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM101(1445) For 4511 devices from ser. no:

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no:

Process displays For current and voltage

Zelio Control-modular measurement and control relays 1

MIC-2 Multi-instrument DATA SHEET

Display and Monitoing Units

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

PHOENIX CONTACT Features

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Series Watt DC Power Supplies

User friendly and easy to program

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Programmable Relay ZEN V2 Units

PI-EX-ME-2NAM/COC-24VDC

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Inform IT Single Pen Circular Chart Recorder

Model Number Structure

MINI MCR-SL-PT100-UI-200

DIGITAL INDICATING CONTROLLER

Model Number Structure

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

FX-485PC-IF RS485 Interface Unit Hardware Manual

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

CJ1W-PTS/PDC/PH41U/AD04U

NX-series Temperature Control Unit NX-TC

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

C160 Wall-/Pipe Mounted Universal Process Indicator

PI-EX-ME-2NAM/COC-120VAC

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

NA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS.

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

Digital Multifunction Meters. Digital Multifunction Meters

DC 2-wire Cylindrical Inductive Proximity Sensor

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

Model Number Structure

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

RM84 miniature relays

Signal Doublers. VariTrans A 20300

Solid-state Timer H3YN

SystempaK (Digital/File Type) Dual Input Arithmetic Relay Module Model J-SCM 92/97

Autoranging True RMS Multimeter User Manual

SensoTrans DMS A 20220

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

PHOENIX CONTACT - 12/2007

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Transcription:

Digital Panel Meters 40 Series RTD INPUT DIGITA PANE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter functions igh visible, 0.8" (20.3mm) high and bright ED 48 (1.89) mm (inch) MODE: 40DR R1 [1][2] ORDERING INFORMATION Code number: 40DR R1 [1][2] Specify a code from below for each [1] and [2]. (e.g. 40DR-R1-R/Q) Specify the specification for option code /Q (e.g. /C01/SET) INPUT R1: Pt 100 (JIS'97, IEC) (Usable range -200 to +850 C, -328 to +1562 F) Pt 100 (JIS'89) (Usable range -200 to +650 C, -328 to +1202 F) [1] POWER INPUT AC Power K3: 100 120V AC (Operational voltage range 85-132 V, 47-66 z) 3: 200 240V AC (Operational voltage range 170-264 V, 47-66 z) DC Power R: 24 V DC (Operational voltage range 24 V ±20 %, ripple 10 %p-p max.) [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9533) GENERA SPECIFICATIONS Construction: Panel flush mounting Connection: M3 screw terminals (torque 0.6 N m) Solderless terminal: Refer to the drawing at the end of the section. Recommended manufacturer: Japan Solderless Terminal MFG.Co.td, Nichifu Co.,ltd Applicable wire size: 0.25 to 1.65 mm 2 (AWG 22 to 16) Screw terminal: Nickel-plated steel ousing material: Flame-resistant resin (gray) Isolation: Input to power A/D conversion: Σ Δ Sampling rate: 10 times/sec. (100 msec.) Averaging: None or moving average Setting: (Front button) Temperature unit Moving average Brightness Others Recommended solderless terminal 6 (.24) max 3.3 (.13) max mm (inch) DISPAY Display: 4 digits of 20.3 mm (0.8 inch) height, 7-segment, red ED Display range: -9999 to 9999 Decimal point position: 10 1 or none Zero indication: igher-digit zeros are suppressed. Over-range indication: 'S.ERR' blinks surpassing the permissible range. 'B.ERR' blinks at burnout. Engineering unit indication: Sticker label attached DC, AC, mv, V, kv, μa, ma, A, ka, mw, W, kw, var, kvar, Mvar, VA, z, Ω, kω, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s 2, inch, l, l/s, l/min, l/h, m 3, m 3 /sec, m 3 /min, m 3 /h, Nm 3 /h, N m, N/m 2, g, kg, kg/h, 40DR SPECIFICATIONS ES-9533 Rev.8 Page 1/6

N, kn, Pa, kpa, MPa, t, t/h,, F, %R, J, kj, MJ, rpm, sec, min, p, %, ppm, etc. INPUT SPECIFICATIONS RTD (3-wire) Maximum leadwire resistance: 10 Ω per wire Sensing current: Approx. 0.5 ma Usable range (conformance range): Pt100 (JIS 97, IEC) -200 to +850 or -328 to +1562 F Pt100 (JIS 89) -200 to +650 or -328 to +1202 F Operational range: -230 to +880 or -382 to +1616 F old Input: Dry contact input Detecting level: 1.5 V Sensing: Approx. 5 V DC, 1 ma INSTAATION Power consumption AC: Approx. 1.3 VA for 100 120 V Approx. 1.2 VA for 200 240 V DC: Approx. 0.5 W Operating temperature: -10 to +55 C (14 to 131 F) Operating humidity: 30 to 90 %R (non-condensing) Mounting: Panel flush mounting Weight: 160 g (0.35 lb) PERFORMANCE Accuracy -200 +200 C: ±0.2 C rdg ±1 digit 200 850 C: ±0.6 C rdg ±1 digit -328 +1562 F: ±1 F rdg ±1 digit Temp. coefficient: ±0.1 / ine voltage effect: ±1 digit over voltage range Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @1 minute (input to power to ground) STANDARDS & APPROVAS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 ow Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input to power: Reinforced insulation (300 V) RoS Directive EN 50581 40DR SPECIFICATIONS ES-9533 Rev.8 Page 2/6

DISPAY MAND Displayed value is held with an external command input. Connect the contacts across to. MODE: 40DR (a) 5V CMOS, TT (c) Photo-Coupler 5 6 Photo-Coupler 5 6 (b) Transistor (d) Relay 5 5 6 6 Relay EXTERNA VIEW (1) Front Panel (3) 4-digit Display (4) Polarity Indicator (2) Sticker abel (5) Disp/ Button (6) Scale/ Button (8) Up Button (7) Shift Button PONENT IDENTIFICATION No. PONENT FUNCTIONS (1) Front panel Removed at conguration. (2) Sticker label Engineering unit label position (3) 4-digit display 4-digit ED display. Range: 0 to 9999 (not including decimal point) (4) Polarity indicator Turns on when negative value is displayed (5) (6) Disp/ button Scale/ button (7) Shift button (8) Up button Used to select setting value. Used to move on to the display setting modes; or to shift through setting items in each setting mode. Used to move on to the zero & span adjustment modes; or to shift through setting items in each setting mode. Used to move on to the setting standby status and shift through display digits in each setting item. 40DR SPECIFICATIONS ES-9533 Rev.8 Page 3/6

PARAMETER IST ZERO & SPAN ADJUSTMENTS PARAMETER DISPAY FUNCTION DEFAUT VAUE Zero adjustment Adjustment value for -200 C To distinguish from span adjustment, the fi rst decimal point is blinking Span adjustment Adjustment value for 850 C Temperature unit Display in Celsius Display in Fahrenheit (Temperature range: -328 to +1562 F)* 1 Decimal Point Position 10-1 or none Decimal point position for celsius *1. For Fahrenheit, the value is rounded to integer. Decimal point position setting is not available. DISPAY SETTING MODE PARAMETER DISPAY FUNCTION DEFAUT VAUE Moving Average Brightness Initialization No moving averaging Moving average with 2 samples Moving average with 4 samples Moving average with 8 samples Moving average with 16 samples Brightness level 1 (dark) Brightness level 2 Brightness level 3 Brightness level 4 Brightness level 5 (bright) Non-initialization Initialize settings (change to factory settings) * 1 Version Indication Version number, indication only *1. While is shown, pressing Disp/ button or Scale/ button initializes settings. Activating initialization, user s specifi ed parameters will be deleted and overwritten with the factory default values. Notice that after this, Ex-factory settings will be irrecoverable. 40DR SPECIFICATIONS ES-9533 Rev.8 Page 4/6

DIMENSIONS unit: mm (inch) TOP VIEW 92 (3.62) FRONT VIEW 103 (4.06) SIDE VIEW 11 (.43) 85 (3.35) 4 (.16) 48 (1.89) 45 (1.77) REAR VIEW 6.4 (.25) 12 (.47) 10 M3 SCREW TERMINAS 1 2 3 4 5 6 7 8 9 10 PANE CUTOUT unit: mm 92 + 0 0.8 min. 75 45 + 0 0.6 min. 120 Panel thickness: 1.6 to 8.0 mm 40DR SPECIFICATIONS ES-9533 Rev.8 Page 5/6

SCEMATIC CIRCUITRY & CONNECTION DIAGRAM RTD A B 1 2 9 U(+) 10 V( ) POWER B 3 5 A/D Converter Digital Computation 4 7 6 8 Display / Setting Specifications are subject to change without notice. 40DR SPECIFICATIONS ES-9533 Rev.8 Page 6/6