AEW36.2. Pulse Adapter. Siemeca AMR

Similar documents
AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

AEW Pulse Adapter. Building Technologies

Network nodes with gateway

AB Axis Industries. Use

The network node works extremely well in more complex building environments (e.g. where fire doors/glass walls are installed).

Network node WTT56.. A6V _en--_c Building Technologies

M-Bus Central Unit. Use

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

Immersion Temperature Sensors

M-Bus Central Unit OZW10

MID approval no. DE-08-MI004-PTB004 Date of release

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

SonoSelect and SonoSafe energy meters

Heating Circuit Controller

SONOMETER TM 500 Ultrasonic compact energy meter

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

RNN5-STD NETWORK NODE FOR AMR SYTEMS

RF adapter plugs, dimming

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

SonoSelect 10 and SonoSafe 10 energy meters

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Electrical Actuators

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

MINI MCR-SL-UI-REL(-SP)

Heating Circuit Controller

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

ABB 520BID01 Binary Input datasheet

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

multipulse, multilog Installation and operating manual All that counts. EnergyMetering

ERF910. RF Repeater. Synco living

MINI MCR-SL-UI-2I(-SP)(-NC)

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Non-communicating room controllers

Feeder protection relay SPAA 121 C. Product Guide

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Status display unit with P-bus connection

Electrical Actuators

A2000 Multifunctional Power Meter

LED Driver Compact fixed output

Solenvis SL80 Pulse to M-Bus Converters

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

MC 11 EB-2 Power supply cabinet with external bus, AC version

PADPULS2 M-BUS Pulse Input Modules

Control Panel CP600 CP651, CP651-WEB

MINI-PS AC/10-15DC/8

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Residual overvoltage relay

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

multipulse, multilog Installation and operating manual All that counts. EnergyMetering

Non-communicating room controllers

PHOENIX CONTACT - 07/2006

Communication module to connect M-bus devices to POL6xx.xxx controllers.

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

PI-EX-ME-2NAM/COC-24VDC

Operating instructions. Standstill monitor A / / 2011

Control Panel CP600 CP635, CP635-B, CP635-WEB

Redundancy unit CP-A RU

Operating instructions. Switching amplifier DN0210 DN / / 2015

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

TU531, TU532 Terminal Unit

AMBUS IS M-Bus pulse collector

Extension module for lighting control

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

multipulse, multilog Installation and operating manual All that counts. EnergyMetering

PI-EX-ME-2NAM/COC-120VAC

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card

Power supplies.

Earth-fault Relay SPAJ 110 C. Product Guide

MCX08M2 Programmable controller

Meter Bus. Intelligent Communication

Operating Manual -ENGLISH- Page 1 KWG-ISO

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

MINI MCR-SL-PT100-UI(-SP)(-NC)

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Power supply CP-C 24/5.0

RM35TF V AC

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Add-on radio module WFZ16 / WFZ166

Central Communication Unit OZW775

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Messaging module CP-C MM

METRAtest 36ASi AS Interface System Tester

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Level sensor Stainless steel version Model RLT-1000, for industrial applications

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

GPLS-25 DATASHEET Março 2012

Fiber optic converter audio and CAN TA OPERATION MANUAL

Transponder card holder

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Transcription:

2 873 Siemeca AMR Pulse Adapter AEW36.2 The AEW36.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to a Siemeca AMR network. For setting the parameters, the pulse adapter is equipped with 2 interfaces, 1 wired interface and 1 optical interface. Use The pulse adapter is a component of the Siemeca AMR system. It is for installations where consumption meters with pulse output are used the data of which shall be collected by the Siemeca AMR system. Such devices can be meters for hot water, cold water, gas, electricity, etc. Functions Acquisition of the pulses delivered by the connected consumption meters Monitoring the connecting cable in the case of metering devices with NAMUR circuit Handling of pulses and storage of consumption data and set day values Wireless transmission of data 6 times a day to the WT..16.. network nodes of the Siemeca AMR system CE1N2873en www.qvedis.com

Type summary Standard version AEW36.2: Connection of 2 meters to the connecting cable by means of the cable connectors supplied with the unit. Labeling in German. Country-specific version AEW36.2/DK: Connection of 2 meters to the pulse adapter s terminal block. Labeling in Danish. Ordering When ordering, please give type reference: AEW36.2 Equipment combinations When installing, the pulse adapter must be programmed with the data set delivered with the parameter setting software for the respective meter. If meters not contained in the meter data base shall be connected, a new data set must be requested from: QVEDIS GmbH Sales Support Sondershäuser Landstr. 27 D-99974 Mühlhausen Tel.: +49 (3601) 46 83-0 Fax: +49 (3601) 46 83-75 E-Mail: info@qvedis.com With the correct data set installed, the following types of meters can be connected: Water meters with pulse output Heat meters with pulse output Gas meters with pulse output Steam meters with pulse output Electricity meters with S0 interface (note: an additional S0 converter is required, e.g. z.b. IC-2, available by Nordwestdeutsche Zählerrevision Ing. Aug. Knemeyer GmbH & Co. KG, Heideweg 33, 49196 Bad Laer) Technical design The pulse adapter handles pulses in accordance with the following specification: blue / red to AEW Pulse source limit values (if parameters are appropriately set) Electronic outputs residual voltage when switched < 0.7 V (Open Collector, max. frequency < 17 Hz Open Drain) min. pulse width 30 ms Mechanical switches bounce time < 1 ms (Reed contact, relays) max. frequency < 2 Hz min. pulse width 260 ms R2 R1 Mechanical switches resistance R1 2.2 kohm with NAMUR circuits resistance R2 5.6 kohm The inputs are protected against overvoltages. Open collector outputs must be connected with the correct polarities: Channel 1: + blue, ground Channel 2: + red, ground

Power supply The pulse adapter is powered by a lithium battery which has a service life of 12 + 1 years. It cannot be changed in the field. Data transmission Data are transmitted to the Siemeca AMR network 6 times a day. Display steps short press of button short press of button short press of button Statistik Statistik Statistik Statistik Statistik Statistik Statistik Statistik long press of button The LCD of the pulse adapter has 4 display levels: Meter 1 ( Zähler 1 ) Meter 2( Zähler 2 ) Meter 1 statistics Meter 2 statistics The display level currently used is indicated by a little arrow ( ) below the name of the level. A short press of the button produces a switching action within the same display, a long press produces a change from one display level to the next. The first 2 display levels show current, meter-related values. The other 2 display levels show 13 end-of-the-month values of the relevant meter. Display Display levels 1 and 2 (meters 1 and 2) are identical. Statistik Statistik Display level meter 1 or meter 2 In the event of fault (severe, constant fault), this is the standard display. It alternates with the display showing the date the fault occurred. In the event of a temporary fault, the respective error code is displayed. This display alternates with a blank display. In normal operation, the standard display shows the consumption. kw h C GJ/ h The display test switches all display segments on and off. Consumption on the set day. This display alternates with the display showing the set day (notation: dd.mm). If, during the pulse adapter s operation, some other set day is programmed, the new set day appears here. Identification number of the connected meter (to be entered when setting the meter s parameters). 3/8

Data set number (describes the type of meter). h Number of operating hours. Primary address When pressing the button for more than 2 seconds in this step, the transmission of 8 installation telegrams will be started. IrDA primary address. Software version. Installation telegrams: Sending installation telegrams; the 2 digits indicate the remaining telegrams for the 2 channels of the pulse adapter. Display levels 3 and 4 (meter 1 statistics and meter 2 statistics) are identical. They show the consumption values and the date of that consumption over the past 13 months. Statistik Statistik Display level meter 1 statistics or meter 2 statistics Alternate display of consumption value and last day of the previous month (notation: dd.mm.yy). Alternate display of consumption value and last day of the previous month (notation: dd.mm.yy). Displays continue for the last 13 months. Error code Error code Description of fault 2 Number of operating hours 6 Pulse acquisition channel 1 open-circuit 7 Pulse acquisition channel 1 short-circuit 8 Pulse acquisition channel 2 open-circuit 9 Pulse acquisition channel 2 short-circuit B Number of communication via IrDA exceeded C Number of communication via M-bus exceeded F Device not initialized

Engineering notes To ensure correct data transmission, the pulse adapter should be installed in locations where radio transmission is not impaired. In case of doubt, the transmission conditions are to be tested with the PC radio module (refer to Data Sheet CE1N2876). Length of connecting cable For immunity reasons, the total length of the connecting cable may not exceed 10 m. Mounting notes Electrostatic Sensitive Devices f Mounting All modules integrated in the meters are electrostatically endangered components. The freely accessible contacts (cable end, plug connector) are only partially protected against interference. Skilled personnel should avoid wearing polyester clothing and shoes with plastic soles as this type of clothing promotes electrostatic charging. Electrostatic charging of skilled personnel must be deflected when handling open components e.g. by touching an earthed piping system. When installing the meter, insert 1 wire of the pulse adapter s connecting cable and 1 wire of the meter s connecting cable into one of the cable connectors supplied with the unit. Then, squeeze the connector with a pair of pliers. This connection cannot be separated and offers degree of protection IP54. Only for AEW36.2/DK: With the housing cover open, insert the meter connecting cables with the O-ring from the rear of the unit into the cable strain relief and connect the cables to the terminal block. Then, close the housing. Commissioning notes Wired parameter settings Parameter settings via IrDA Triggering installation telegrams The pulse adapter is to be programmed during installation. Enter the following data for each channel: Type of pulse source (Reed switch, Reed switch with NAMUR, Open Collector, etc.) per input Type of medium (gas, water, etc.) per input Physical variable (kwh, m 3, etc.) per input Pulse valency per input Set day per input (1 set day per year) Meter readings when commissioning the pulse adapter, per input Meter number (identification number) per input The parameters can be set wire-bound or via the integrated optical interface (IrDA): For wired parameterization, a laptop (Windows 98 or higher), the ACT20 parameter setting software, and the WFZ.MBM programming adapter are required. Parameterization via the integrated optical interface (IrDA) is carried out by means of a PDA. For the pulse adapter to log on to the Siemeca AMR network, installation telegrams must be triggered on the pulse adapter after parameterization: 5/8

On the first display level, press the button briefly a few times until you reach the M-bus display: Then, keep the button depressed for more than 2 seconds. The installation telegrams will be sent: The display shows the number of the remaining installation telegrams for each channel. Technical data conformity 89/336/EEC (EMC directive) 1999/5/EEC (R&TTE directive) Degree of protection IP 54 to EN 60 529 Safety class III to EN 60 950 Electromagnetic compatibility Immunity Emissions Security of IT equipment Operating voltage Life expectancy Nominal frequency Transmitting power Transmission frequency Perm. ambient temperature Transport and storage Operation Weight EN 301 489 1 / -3 V1.2.1 (2000-08) EN 61000-6-2 :1999 EN 300 220 1 V1.3.1 (2000-09) - 3 V1.1.1. (2000-09 EN 60 950 DC 3 V 12 +1 years 868.3 MHz < 5 mw 6 times / 24 hours 25 +60 C 0 55 C 0.3 kg

39,5 79 Connection diagrams INP 1 INP2 U1 Connection of any type of meters with pulse output blue red P1 P2 U1 AEW36.2 pulse adapter P1, P2 Meter with pulse output AC 230 V INP 1 INP2 U1 blue red Connection of electricity meters with S0 interface OUT INP N1 OUT INP N2 S0 P1 S0 P2 U1 AEW36.2 pulse adapter P1, P2 Electricity meters with pulse output N1, N2 WHZ.SO pulse converter Dimensions 3,5 79 90 95,5 27,3 Dimensions in mm Connecting cable length is 350 mm. 7/8

Overview of Siemeca AMR documentation Type of unit Siemeca AMR system Type reference Document Data Sheet CE1N2870 Engineering Manual CE1J2870 Heat cost allocator WHE46 Data Sheet CE1N2877 Wireless pulse adapter AEW36.2 Data Sheet CE1N2873 Heat meters WFM26, WFQ26. Data Sheets CE1N5333, CE1N5347, CE1N5338, CE1N5348 Water meters WFC26, WFH26, WFC36, WFH36, WMC36, Data Sheets CE1N5341, CE1N5343 Data Sheets CE1N5328 Data Sheets CE1N5329 WMH36 Network node WTT16 WTX16 Data Sheet CE1N2874 Network node with Gateway Software WTX16.IP WTX16.GSM WTX16.MOD ACS, ACT Data Sheet CE1N2878 Data Sheet CE1N2875 PC radio module WTZ.RM Data Sheet CE1N2876 M-bus central unit OZW10 Data Sheet CE1N5362 The information provided in this Data Sheet only gives general descriptions and general technical features which, in the case of specific applications, may not necessarily apply, or which may change due to further development of the product. Technical features are binding only when expressly agreed upon at the time a contract is concluded. 2007 QVEDIS GmbH Subject to alteration