VAMP 50 series. with native IEC and arc flash protection

Similar documents
VAMP 50, VAMP 51, VAMP 52, VAMP 55. Protection relays with native IEC and arc flash protection

Feeder/ Motor Protection Relay VAMP 40

Protection relays.

VAMP 50 series. with native IEC and arc flash protection. Protection

Line manager VAMP 259 for distance and line differential protection

VAMP 50 series. with native IEC and arc flash protection. Protection CUSTOMER BENEFITS

Comprehensive motor protection and control from VAMP

Feeder/Motor Manager Series VAMP 230 VAMP 245 VAMP 255 VAMP 257

VAMP 259. Line manager for distance and line differential protection. Protection MAIN CHARACTERISTICS

VAMP 57. Multipurpose feeder and motor protection relay. m.vamp.fi

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Protection VAMP 57. Multipurpose feeder and motor protection relay

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

Measuring and monitoring units VAMP 96 VAMP 260 WIMO 6CP10

TWO-WINDING TRANSFORMER DIFFERENTIAL

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide

GE Multilin 350 Feeder Protection Relay Specifications

RELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Perfect protection smallest space

Feeder protection relay SPAA 121 C. Product Guide

A low-cost, economical solution for distribution feeder protection

Residual overvoltage relay

e 2 TANGO -400 Overcurrent Relay K Catalogue EN

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Advanced distribution feeder solution with integrated protection, monitoring, and control

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Substation Automation Products. Line differential protection RED670 Relion 670 series

Products Portfolio. Pole mounted Vacuum Recloser

Bus Bar Protection Relay B-PRO 4000

Feeder Protection Relay REF 610. Product Guide

NPW800R RETROFITTING. Power and Volatge Protection Relay

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

MiCOM P111. Three phase and earth fault overcurrent relays

PROTECTION, AUTOMATION & CONTROL

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

MiCOM P122C Time-Overcurrent Protection

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

MIC-2 Multi-instrument DATA SHEET

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Electrical Integration with Smart Communication

Perfect protection smallest space

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

SACE Emax 2 Specification guide

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

Siprotec 7ST61 / 7ST63

Feeder protection relay

Feeder protection relay SPAA 341 C. Product Guide

Transformer Protection Relay

Relion 615 series. Feeder protection and control REF615 ANSI Product guide

S o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s. automation, control & communication

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

Protection Relays PHASE & RESIDUAL OVERCURRENT

750/760 Feeder Management Relay Instruction Manual

AQ-200 SERIES PROTECTION,CONTROL, MEASUREMENT AND MONITORING IEDS

VAMP 221. Table of Contents

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

G - Base. Relays THREE PHASE + NEUTRAL CURRENT PROTECTION RELAY

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Protect induction and synchronous motors with one relay.

Voltage Transducer UMT516 / MT516

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

Feeder Terminal. REF 542plus. Product Guide

ACOS 300. Reliable protection for network and constructions in medium- and high voltage

Relion 615 series. Feeder Protection and Control REF615 Product Guide

MiCOM P220, P225 and P226C

Lightweight and flexible recloser control for single-phase applications

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Three phase and earth fault overcurrent relays

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

THE INTEGRATED TESTING SOLUTION

2018 Catalog. Easergy P3. Network Protection Relays

Protective Relays & SCADA Systems

Feeder Protection REF615 Ver Technical Presentation. ABB Oy Distribution Automation. Prashant Ganoo Regional Product Marketing Manager

Communication Gateway COM 610. Product Guide

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

with Backlight Graphic LCD Screen

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

TFS 2100 Traveling Wave Fault Location System

Transcription:

VAMP 50 series with native EC 61850 and arc flash protection V

VAMP 50 series protection relays VAMP 50 family low and mid range relay series with EC 61850 The VAMP 50 series protection relay family is based on proven technology concept developed in close cooperation with customers. User-friendliness describe VAMP products, the feature which receives a good grade in customer satisfaction day after another. The VAMP 50 over current and earth fault protection relay developed to cover basic protection needs for OEM, utility, and industrial applications. Thanks to its costeffective and flexible design, the VAMP 50 will provide an excellent alternative for various protection applications. The VAMP 51 offers enhanced control functionality like an auto-recloser, VAMP 52 combined protection functions for feeders, motors and directional earth fault. The arc option for the VAMP 50 series is designed to enable the extremely rapid exchange of light and current information with other VAMP relays or a VAMP 221 arc flash protection system via a modular inter station bus located between the relays. t will be possible to connect up to three supervised arc point sensors to the arc option module, giving trip contact activation in less than 7 ms from the occurrence of an arc flash fault. Robust and flexible hardware Modular design with versatile option offering for communication, arc protection and D/DO extension Automatic adaptation of new / removed hardware Designed for demanding industrial conditions Common technology to gain volume benefits Powerful CPU supporting native EC 61850 Utilisation of other Vamp platform accessories mproved safety with economical and fast arc flash protection option High user friendliness and functionality Same software platform as used in VAMP 200 series Active functions visible only for the operator Using the USB connection the relay configuration is faster than using serial interface Modern Human Machine nterface (HM) Mid-size and clear LCD display Single line diagram with control, indication and live measurements Programmable function keys and LEDs USB port in front with standard cable 2

Ease of use User-friendliness has always been a feature of Vamp products, and the VAMP 50 series is no exception. A great deal of effort has gone into the design of the operational aspects of the new products. The rapid relay setting parameter up and downloading with an unique VAMPSET setting tool lifts usability of the product now to another dimension. Unicode support allows the menu view and setting tool translation to various international languages including for example Russian and Chinese. The informative human machine interface show all the required information to the user with support of customized legend texts. VAMP 50 family HM interface Navigation push buttons Function buttons with User configurable legend texts CB control Protection setting group selection Freely programmable 128 x 64 LCD dot matrix display Single line diagram and freely assignable analogue values Unicode language support Local port USB interface Programmable LEDs User configurable legend texts 12 LEDs, 2 fixed (power, error) and 8 freely programmable (2 for push buttons) The template for user legend texts is a part of the product documentation. The texts printed on the transparency film allow customization of the relay. The optional D/DO, arc connection and communication modules can be added to the basic relay later on in order to extend the functionality of the relay during it s life time. Two optional module slots Extends the functionality of the relay Remote port, RS485, RS232 & Ethernet (RJ-45 or fiber) Arc, D/DO 3

VAMP 50 series protection relays VAMPSET Setting and Configuration Tool VAMPSET is a user-friendly, free-of-charge relay management software for setting, parameterising and configuring of VAMP relays. Via the VAMPSET software relay parameters, configurations and recorded relay data can be uploaded/downloaded between the operator s PC and the VAMP relays. Supporting the COMTRADE format VAMPSET also incorporates tools for analyzing relay events, waveforms and trends from disturbance recordings caprured by the relays, e.g. during a network fault situation. Using a standard USB cable the PC running VAMPSET connects to the front port of the VAMP 50 series relays. The VAMPSET software also supports TCP/P communication via an optional communication port. Featuring true multi-language support the software runs on Windows Vista/XP/2000/NT and Windows 98/95 without any need for configuration of the PC. The VAMPSET software is future-safe supporting coming updates and new VAMP products. As a regular feature of the VAMP relays standard COMTRADE type disturbance recording files can be uploaded for subsequent evaluation of any network event recorded. The USB connection is much faster than serial communication. Standard USB communication cable can be used. The phase sequences for currents and voltages can be read on-line from the clear and explicit phasor diagram screen for easy commissioning of the relay. nput /Output options for VAMP 50 series The VAMP 50 series host various option modules in order to up-grade the relay functionality from the basic protection unit to a more advanced protection relay. VAMP 50 VAMP 51 VAMP 52 VAMP 55 Analog inputs 3 x 1 x o 3 x 1 x o 3 x 1 x o, 1 x U 4 x U Digital inputs 2 (7) 2 (7) 2 (7) 2 (7) Trip relays 4 (5) 4 (5) 4 (5) 4 (5) Control relays 2 2 2 2 ma output Option Option Option Option Arc protection Option Option Option - Front port USB USB USB USB Optional rear port External RTD input module RS 485/RS 232/ Fibre/Ethernet RS 485/RS 232/ Fibre/Ethernet RS 485/RS 232/ Fibre/Ethernet RS 485/RS 232/ Fibre/Ethernet Option Option Option Option 4

Whether the time-grading or blocking based protection coordination principle is used, the traditional protection systems may not provide fast enough protection of substation faults. Further, high-impedance type of earthfaults may cause prolonged operation times of earth-fault relays leading to the significant release of the arcing energy. These facts pose a considerable risk to human beings and economical assets. By applying a modern, high-speed arc protection system the damage may be considerably reduced. Such an arc protection system is an optional feature incorporatable in all current measuring VAMP relays. The VAMP relays measure the fault current. f the arc protection option is selected the relays also monitor light via arc sensor channels monitoring the whole switchgear. Should an arcing fault occur in the switchgear the arc protection system provides an extremely fast tripping of the circuit breaker. The fault will be prevented from spreading and quickly isolated, which may save human lives and valuable economical assets. Arc flash protection, incorporating continuous self supervision for the sensors, is optional in VAMP 50 series current measuring relays. CB Cable Cable CB An arc flash protection integrated in VAMP relay enable station level ultra-fast arc protection system set-up using protection relay hardware and separate arc sensors. Possible arc flash fault in the cable compartment is selectively cleared by the feeder protection relay where as the fault in the circuit breaker or bus bar compartment is tripped by the incoming circuit breaker. The exact location of the arc flash will be detected by the arc flash and relay protection system. L CB Cable L (CB, BB) BB Traditional protection relay systems do not provide fast enough protection in an arc-fault situations. Arc point sensors 5

VAMP 50 series protection relays Communication Vamp is a communication expert with a wide experience in interfacing with different system integrators and SCADA suppliers RTU s, PLC s, gateways etc. using different protocols. Flexible adaptation of the communication protocols together with powerful and easy to use software tools are the key of successful integration. VAMP 50 series and the VAMPSET tool provide access to practically any power system information you may need. Native EC 61850 The 61850 protocol can be used to read or write static data or to receive events sent spontaneously from the relay. n addition, the interface allows peer-to-peer communication between the relays - this is Goose communication. The 61850 interface is configured with familiar, user-friendly Vampset software. The 61850 data model, data-sets, report control blocks and the Goose communication are configured according to the requirements of the system configuration. Vampset is also used to produce CD files, which may be needed for the substation RTU configuration. The VAMP 50 series contains native implementation, which means that the EC 61850 functionality is embedded in the software. VAMP 50 Communication protocols EC 60870-5-101 EC 60870-5-103 Modbus TCP Modbus RTU Profibus DP DNP 3.0 SPA-bus communication EC 61850 DeviceNet Human-Machine-Communication, display Human-Machine-Communication, PC Measurements and condition monitoring The VAMP 50 series offers a complete set of measurement functions to replace the conventional metering functions of switchgear and and controlgear installations. The measurement functions cover phase, line and residual currents, current unbalance, system frequency and harmonics from phase currents. Condition monitoring continuously monitors trip circuits, breaker wear and current transformers. Type of measurement EC Symbol Protection function/measurement Feeder protection Primary current 3 Three-phase current n n n n l 0 Zero sequence current n n n n 2 Current unbalance n n n n L Average and maximum demand current n n n n Primary voltage U One/ three-phase and line voltage n1 n1 n3 U 0 Zero sequence voltage n n n U 2 / U 1 Relative voltage unbalance n Frequency f System frequency n n n n n Power P, Q, S Active, reactive, apparent power )1 n n Energy E+, E-, Eq+, Eq- Active and reactive energy )1 n n Harmonics 2nd to 15th and THD of phase currents n n n n Voltage sags / swells U Voltage sags / swells n Analog ma output, 1 channel AO Any measured or calculated value, freely scalable n n n n n Control Digital inputs Number of digital inputs (max) 7 7 7 7 7 Output relays Number of trip relays (max) 5 5 5 5 5 Number of control relays (max) 1 1 1 1 1 Object status indication Single line diagram, 8 objects n n n n n Local and remote control Number of controllable objects 6 6 6 6 6 nterlocking and logic Configurable n n n n n VAMP 50 VAMP 51 VAMP 52 VAMP 52 Motor protection VAMP 55 Special applications Based on single phase measurement Condition monitoring Trip circuit TCS Trip Circuit Supervision n n n n n TCS Trip Circuit Supervision with D for T5 (optional) n n n n n CT Supervision CT Supervision n n n n VT Supervision VT Supervision/Fuse failure supervision n CB Wear Breaker wear n n n n 6

Protection stages The user frendlines is built in feature in protection stages also. Setting views are graphical in relay and Vampset HM. Protection stages taken out of use are hidden from the menu in order to show operator only the required information. Protection stages come with two setting groups to enable automatic transfer from main setting to alternative setting. This change can be universal for the entire relay or protection Type of fault EEE Device No. EC Symbol Protection function/measurement Over-current fault function based. The relay has large number of standard inverse curves to adopt various protection requirements. Unique protection curves can be applied for protection applications where standard EC or EEE curves do not provide required protection selectivity. Feeder protection 50/51 3 Three-phase non-directional overcurrent, low-set stage, definite or inverse time n n n n 50/51 3l Three-phase non-directional overcurrent, high-set stage, definite time n n n n 50/51 3l Three-phase non-directional overcurrent, high-set stage, definite time n n n n VAMP 50 VAMP 51 VAMP 52 VAMP 52 Motor protection VAMP 55 Special applications Earth-fault 50N/51N 3l 0 / SEF Non-directional earth-fault, low-set stage, sensitive, definite or inverse time n n n n 50N/51N 3l 0 Non-directional earth-fault, high-set stage, definite time n n n n 50N/51N 3l 0 Non-directional earth-fault,high-set stage, definite time n n n n 50N/51N 3l 0 Non-directional earth-fault, high-set stage, definite time n n n n 67NT 3l 0t ntermittent transient earth-fault protection n n 67N or 50N/51N 3l 0j / SEF Directional or non dir. earth-fault, low-set stage, sensitive, definite or inverse time n n 67N or 50N/51N 3l 0j Directional or non dir. earth-fault, high-set stage, definite or inverse time n n 59N U 0 Zero sequence voltage, low-set stage n n n 59N U 0 Zero sequence voltage, high-set stage n n n Overload 49M T n 49F T Three-phase thermal overload (feeders & cables) n n n Voltage * = number of voltage channels 59 U One-/three-phase overvoltage, low-set stage n1 * n1 * n3 * 59 U One-/three-phase overvoltage, high-set stage n1 * n1 * n3 * 59 U One-/three-phaseovervoltage, high-set stage n1 * n1 * n3 * 24 U / f Volts/hertz overexcitation protection n 27 U< One-/three-phase undervoltage, low-set stage n1 * n1 * n3 * 27 U<< One-/three-phase undervoltage, high-set stage n1 * n1 * n3 * 27 U<<< One-/three-phaseundervoltage, instantaneous stage n1 * n1 * n3 * 27P U 1 <, U 1 << Positive sequence undervoltage n 47 U 2 Negative sequence overvoltage (pgr stage) n Arc flash protection 50ARC/50NARC 3 / 0, L Electrical arc flash protection stage, point sensors, optional n n n n Other functions 79 O -- Auto-reclosure n n 68 nrush and cold load detection n n n n 46 2 / 1 Current unbalance protection (in feeder mode) n n n 46 2 Phase unbalance protection n 47 2 Phase sequence / incorrect phase sequence protection n 48 ST Stall protection n 37 3< Loss of load / under current protection n n 86 Latched trip n n n n n 66 N Frequent start protection n 51F2 f2 Second harmonic O/C stage n n n n 50BF CBFP Circuit breaker failure protection n n n n n 81H/81L f <, f << Overfrequency and underfrequency protection n 81L f<, f<< Underfrequency protection n 25 f, U, j Synchrocheck n 99 8 Programmable stages n n n n DR Disturbance recorder n n n n n 7

VAMP 50 series protection relays VAMP 50 and 51 overcurrent & earth fault relays VAMP 50 is a basic protection relay used for LV and MV feeders in industrial and utility applications as well as for back-up protection. Limited amount of protection functions make this unit cost efficient, user friendly and simple to use. The hardware design allow easy addition of integrated optional modules like arc sensor interface, extension of D / DO channels and various communication module adapters. n VAMP 51, the autorecloser function extends the protection application to overhead line feeder protection in substation or secondary substation systems where the network is low-impedance or rigidly earthed. Programable stages enable user configuring new protection elements and creating new triggering conditions to the disturbance recorder. Typical application / VAMP 50 BB CB Cable 3 50 / 51 3 VAMP 50 49F T 46R 2/ 1 3 o 3 50N/51N 50BF CBFP 68 f2 0, 0 0 0 50NARC Arc 0 50ARC Arc 74TC TCS 86 Lockout Typical application / VAMP 51, feeder mode with auto-reclose BB CB + Cable 3 50 / 51 3 VAMP 51 49F T 46R 2/ 1 3 o 3 50N/51N 50BF CBFP 68 f2 0, 02 0, 02 D 50NARC 79 8 pgr Arc 01 O 1 50ARC Arc 74TC TCS 86 Lockout 8

VAMP 50/VAMP 51 connection diagram L1 L2 L3 + 1 - X2:1 X2:2 ~ VAMP 50 / VAMP 51 Protection functions Front Comm. option - 0 50 / 51 50N/51N 68 Remote VAMP 255 X1:1 X1:2 L1 X1:3 X1:4 L2 X1:5 X1:6 L3 X1:7 X1:8 0 5A 1A X1:9 /O extension module X6:1 X6:2 X6:3 X6:4 X6:5 X6:6 X6:7 X6:8 Arc option or D / DO module 3 3 3 46R 2/ 1 49F T 0, 02 0, 02 50BF CBFP 50ARC Arc 50NARC Arc 01 f2 74TC TCS 86 Lockout Additional protection functions/ VAMP 51 79 8 pgr Auto Reclose T1 X3:17 X3:16 X3:15 T2 X3:14 X3:13 T3 T4 X3:12 X3:11 X3:10 C 1 X3:7 X3:9 X3:8 F X3:18 X3:19 + + Blocking and output matrix ma out option X3:20 X3:3 D1 - X3:4 D1+ X3:5 D2 - D ma X3:1 AO+ X3:2 AO - X3:6 D2+ Arc option module 1 Arc option X6:1 BO+ X6:2 BO- X6:3 B+ X6:4 B- X6:5 L1+ X6:6 L1- X6:7 L2+ X6:8 L2- B/O L Arc module 1 has two arc sensor interfaces and connectivity from/to other relays via BO channel. The operatiing time for arc flash fault trip is 15 ms. Arc option module 2 RJ-45 RJ-45 X6:1 L1+ X6:2 L1- X6:3 L2+ X6:4 L2- X6:5 L3+ X6:6 L3- L Arc module 2 has three arc sensor interfaces. This module (relay) can also serve as /O unit for VAMP 221 arc protection system. Operating time is 7 ms. /O extension module D / DO module X6:1 T5 X6:2 X6:3 D3 D X6:4 C omm X6:5 D4 X6:6 D5 D X6:7 C omm X6:8 Di6 9

VAMP 50 series protection relays VAMP 52 feeder and motor protection relay VAMP 52 is a multi protection relay used for LV and MV feeders in industrial or utility applications. Extensive thermal protection functions make this relay optimal for low and medium sized asynchronous motors. Directional earth fault protection in association with an auto-recloser makes this relay cost effective for the feeder protection applications where automatic fault clearance is needed. This relay is flexible, user friendly and simple to use. The hardware design allow easy addition of integrated optional modules like arc sensor interface, extension of D / DO channels and various communication module adapters. Typical applications Feeder mode with auto-reclose Motor mode BB BB CB + CB + Cable 3 VAMP 52 50 / 51 49F 3 T 46R 2/ 1 Cable 3 50 / 51 3 VAMP 52 49M T Uo, UL or U 3 3 68 f2 Uo, UL or U 3 3 46 2 68 f2 o 50N/51N 67NT 0T o 50N/51N 67NT 0T 0, 0 0 0 50NARC Arc 0 50ARC Arc 79 O 1 8 pgr 50BF CBFP 67N 0 0 59N U 0 U 0 74TC TCS 59 (1 1U 1U 1U 27 (1 1 U< 1U<< 1U<<< 86 Lockout M RTD 1... 12 VO 12A_ D Fiber or RS485 0, 0 0 0 50NARC Arc 0 50ARC Arc 37 3< 8 pgr 50BF CBFP 67N 0 0 59N U 0 U 0 66 N 74TC TCS 59 (1 1U 1U 1U 27 (1 1 U< 1U<< 1U<<< 47 2 48 st 86 Lockout Alternative to Uo protection Alternative to Uo protection 10

2 2 st 0 0 0T f2 0 02 02 VAMP 52 connection diagram L1 L2 L3 1 - X2: 1 X2: 2 ~ VAMP 52 Protection functions Front Comm. option - 0 50 / 51 3 50N/51N, 0 27 U< Remote U 0 X1: 1 X1: 2 X1: 3 X1: 4 X1: 5 X1: 6 X1: 7 X1:8 X1: 9 X1:10 X1: 11 X6: 1 X6: 2 X6: 3 X6: 4 X6: 5 X6: 6 X6: 7 X6: 8 L1 L2 L3 0 5A 1A U /U / U 0 L 1 12 /O extension module Arc option or D / DO module 3 3 46R 2/ 1 46 47 48 66 N 37 3< 67N Autorecloser matrix, 0 67NT 59N U U 0 0 49 T 68 59 U U U 79 Auto Reclose U<< U<<< 50BF CBFP 50ARC Arc 50NARC Arc 01 74TC TCS 86 Lockout Blocking and output matrix T1 X3:17 X3:16 T2 X3:15 T3 T4 X3:14 X3:13 X3:12 X3: 11 X3:10 C1 X3: 7 F X3:18 ma out option X3: 9 X3: 8 X3:19 X3:20 + + X3:3 D1 - X3:4 D1+ X3:5 D2 - X3:6 D2+ D ma UL1 X1:11 X1:10 When the voltage transformer is connected to transform the phase to ground voltage, the voltage measuring mode shall be 1LN Arc option module 1 Arc option X6:1 BO+ X6:2 BO- X6:3 B+ X6:4 B- X6:5 L1+ X6:6 L1- X6:7 L2+ X6:8 L2- B/O L /O extension module D / DO module X6:1 T5 X6:2 X6:3 D3 D X6:4 Comm X6:5 D4 X6:6 D5 D X6:7 Comm X6:8 Di6 Arc option module 2 U12 Should the voltage transformer connection be phase to phase the voltage measuring mode is selected 1LL RJ-45 RJ-45 X6:1 L1+ X6:2 L1- X6:3 L2+ X6:4 L2- X6:5 L3+ X6:6 L3- L X1:11 X1:10 11

VAMP 50 series protection relays VAMP 55 voltage protection relay The Vamp 55 is a multifunction relay suitable for voltage and frequency protection for both utility and industrial applications and also for synchrocheck applications. The relay is equipped with 4 voltage inputs that can be configured with any of the available predefined voltage mode setups. 3LN+LLy / LNy = phase voltage and synchrocheck 3LN + Uo = Line to neutral and zero sequence voltage Typical application Cable CB BB VAMP 55 VT 59 27 27P 3U 3U 3U< 3U<< U 1< U 1<< 3U 3U<<< 47 U 2 59N U 2 Uo Uo 81H/81L 81L 81R f< f<< f< f<< df/dt 25 f, v 8 pgr 50BF CBFP 74TC TCS 86 Lockout 12

VAMP 55 connection diagram VAMP 55 VAMP 55 is applied in 3LN+LLy mode. The phase voltage (line to neutral) is measured from the bus bar and the realy calculates phase-to-phase and zero sequence voltage. The U 4 voltage channel is used for synchrocheck in the feeder side. * 3LN+LLy /O extension module D / DO module X6:1 X6:2 X6:3 D3 X6:4 Comm X6:5 D4 X6:6 D5 X6:7 Comm X6:8 Di6 D D T5 13

VAMP 50 series protection relays Order Codes VAMP 5 - Accessories Relay type 0 = Overcurrent & earth fault relay 1 = Overcurrent & earth fault relay 2 = Feeder and motor protection relay 5 = Voltage protection relay Order code Description Note VSE001 Fiber optic nterface Module VX052-3 USB Programming Cable Cable 3 m VA1DA-6 Arc sensor Cable 6 m VA1DA-20 Arc sensor Cable 20 m VO 12 AA VO 12 AB VO 12 AC VO 12 AD RTD Module, 12pcs RTD inputs, Optical Tx Communication RTD Module, 12pcs RTD inputs, RS 485 Communication RTD Module, 12pcs RTD inputs, PTC, ma inputs/outputs, RS232, RS485 and Optical Tx/Rx Communication x)!!) VAMP 50, VAMP 51 or VAMP 52: VAMP 55: Phase current inputs [A] Nominal Voltage [V] 3 = 1 A / 5 A 4 = 50... 400 V Earth-fault current input [A] A = 1 A / 5 A B = 0.2 A /1 A Supply Voltage [V] A = 40.. 265 Vac/dc B = 18... 36 Vdc ma output option A = None B = ma output D threshold voltage 1 = 24 VDC 2 = 110 VDC 3 = 220 VDC Optional /O extension modules A = None B = D/DO ( 4 x D + 1 x DO ) C = Arc Protection; 2xSensor, BO D = Arc Protection; 3xSensor Optional communication module 1 A = None B = RS 485 interface D = Plastic/Plastic fibre interface E = Glass/Glass fibre interface F = Plastic/Glass fibre interface G = Glass/Plastic fibre interface H = Ethernet RJ-45, 10 Mbps interface K = EC 61850 RJ-45, 10 Mbps interface L = RS232 interface with option for module 2 P = Profibus interfacea R = 2 x ST 100Mbps ethernet fibre interface with EC 61850 S = 2 x RJ-45 Mbps Ethernet interface with 61850 Optional communication module 2 A = None B = RG-B timesyncronisation input C = RTD fiber optic interface D = RJ-45 Ethernet nterface 10 Mbps E = RJ-45 EC 61850 10 Mbps interface F = LC 100 Mbps Ethernet fibre interface G = LC EC 61850 100 Mbps Ethernet fibre interface x) Available Q2/2011!!) None Supply Voltage [V] A = 40.. 265 Vac/dc B = 18... 36 Vdc ma output option A = None B = ma output D threshold voltage 1 = 24 VDC 2 = 110 VDC 3 = 220 VDC Optional /O extension modules A = None B = D/DO ( 4 x D + 1 x DO ) Optional communication module 1 A = None B = RS 485 interface D = Plastic/Plastic fibre interface E = Glass/Glass fibre interface F = Plastic/Glass fibre interface G = Glass/Plastic fibre interface H = Ethernet RJ-45, 10 Mbps interface K = EC 61850 RJ-45, 10 Mbps interface L = RS232 interface with option for module 2 P = Profibus interface R = 2 x ST 100Mbps ethernet fibre interface with EC 61850 S = 2 x RJ-45 Mbps Ethernet interface with 61850 Optional communication module 2 A = None B = RG-B timesyncronisation input C = RTD fiber optic interface D = RJ-45 Ethernet nterface 10 Mbps E = RJ-45 EC 61850 10 Mbps interface F = LC 100 Mbps Ethernet fibre interface G = LC EC 61850 100 Mbps Ethernet fibre interface!!) Supply voltage has to be 110 Vac/dc or more. Possible to order in combination with the following Optional communication module 1: (B) RS 485 first or (L) RS 232 14

Technical Data Main technical data Dimensional drawings Auxiliary voltage, Uaux 40 265 V ac / dc Rated phase current n 1A or 5A - current measuring range 0 50 x n Rated neutral current on 1A or 5 A (optionally 0,2 A/1 A) - current measuring range 0 10 x 0 Thermal Withstand Rate frequency fn Digital inputs (external voltage) - selectable nominal voltage (treshold) Trip contacts Control contacts 4 x n (continuous), 100 x n (for 1 s) 50 / 60 Hz (45 65 Hz) 2 pcs 24/110/220 V dc 4 pcs 2 pcs Tests and environment EMC emission tests: EN 55011, EC 60255-25 EMC immunity tests: EC 60255-11, EN 61000-4-11 Environmental tests: EC 60255-22-1 EN 61000-4-2, EC 60255-22-2 EN 61000-4-3, EC 60255-22-3 EN 61000-4-4, EC 60255-22-4 EN 61000-4-5, EC 60255-22-5 EN 61000-4-6, EC 60255-22-6 EN 61000-4-8 EN 61000-4-9 EC 61000-4-17 EC 60068-2-1 Ad EC 60068-2-2 Bd EC 60068-2-1 Ab EC 60068-2-2 Bb EC 60068-2-30 Db EC 61068-2-78 Cab Mechanical tests: EC 60255-21-1 Operating temperature EC 60255-21-2-10 +60 C Relative humidity < 95 %, no condensation allowed Degree of protection (EC 60529) Weight Dimension (w x h x d) P54 2,0 kg 128 x 170 x 190 mm 15

We keep electricity running With its headquarters in Finland, Vamp Ltd specializes in protection relays, arc flash protection and measuring and monitoring units for power systems. Vamp s medium-voltage and sub-transmission protection relays are used in a number of applications, from overhead line feeders and substations to power plants and industrial power system. Their unique integrated arc flash fault protection functionality enhances the safety of both people and property and has made Vamp a leading brand in arc flash protection worldwide. Vamp is a member of Schneider Electric, a global specialist in energy management. Our success is based on competitive standard products, constant development by our designers possessing experience from three protection relay generations, our long-term partnerships, flexibility and 24 hour care of the customers. Our organization has been audited and found to be in accordance with the requirements of the SO 9001:2000 management system. Vamp Ltd P.O.Box 810 F-65101 VAASA Finland Visiting address: Vaasa Airport Park Yrittäjänkatu 15 Vaasa, Finland Tel: +358 20 753 3200 Fax: +358 20 753 3205 Email: vamp@vamp.fi http:// www.vamp.fi We reserve the rights to product alterations without prior notice. Copyright Vamp Ltd. All trademarks are the property of their respective holders. VB50.EN006a