DeviceNet of Things Use Cases, Value Proposition and Status of Specification. John Caspers Rockwell Automation. February 22, 2017

Similar documents
DeviceNet of Things Use Cases, Value Proposition and Status of Specification

DeviceNet - CIP on CAN Technology

Revolutionizing control wiring

DEFAULT IP ADDRESS

Solutions for machine builders. Build a better machine with Eaton solutions integrated

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

M3-61B DeviceNet Slave Module. M3-61B DeviceNet Slave Module CONTROL TECHNOLOGY CORPORATION

Electrical solutions for machine builders. Build a better machine with Eaton solutions integrated.

DeviceNet Motor Control

Integrating IO-Link Devices into CIP Networks

How to Control and Monitor a C441 Motor Insight via DeviceNet

CDN067 DEVICENET SPECIFICATIONS

Additional instructions Videographic recorder LINAX DR3000. EtherNet/IP Adapter

SE-330/SE-330AU/SE-330HV DEVICENET INTERFACE

MPCR Series DeviceNet Technical Manual

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents

DeviceNet INSTRUCTION MANUAL. Series 956. Resolver Displacement Transducer

SIMATIC. S7 EIP-200S Ethernet/IP Adapter Distributed I/O System. Preface. Product overview. EIP-200S Ethernet/IP Adapter. Installation and wiring 3

DeviceNet for Capacitance Diaphragm Gauge

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.

For the configuration of the I/O-modules in a control system an EDS-file is required. The names of the files are as follows:

X-gateway Interface Addendum DeviceNet Scanner Interface

CDN127 DeviceNet SPECIFICATIONS

in Berlin (Germany) Sponsored by Motorola Semiconductor NEC Electronics (Europe) Siemens Semiconductors Organized by

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

Multidrop Ethernet for In-cabinet Applications

CIP Safety for Drives

SIMATIC. ET 200pro distributed I/O EtherNet/IP interface module. Preface 1. Product overview. The ET 200pro EtherNet/IP module

Tritex II EtherNet/IP - Option

CATALOG NUMBER 193-EDN

Absolute linear encoder LP-38

Power Xpert C445 Motor Management Relay Cheat Sheets

Allen-Bradley Automation

Installation and maintenance instructions

G3 Series DeviceNet TM Technical Manual

GSE Scale Systems Ethernet IP Option

Extending EtherNet/IP TM to Resource- Constrained Industrial Things. Dayin XU, Rockwell Automation Paul Brooks, Rockwell Automation.

Series SD6 Limit with DeviceNet

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

X-gateway Interface Addendum DeviceNet Scanner

T62 - Next Generation of Compact AC Drives

CDN572-5 DEVICENET SPECIFICATIONS

Quick Start Manual G2-2 Series with Ethernet Interface

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

EQ7000. User Manual. Rev 1.00

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

GPD 515/G5 DeviceNet Technical Manual

DeviceNet Interface for Bayard-Alpert Pirani Gauge

Stratix Industrial Ethernet Switch. Features and Benefits

Product Overview. by Bihl+Wiedemann

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

DN-01 Instruction Manual

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

POINT I/O Family. Chapter. Overview

2002 Series DeviceNet Technical Manual

1782-JDC DeviceNet Serial Gateway User s Manual

Ethernet/IP Module. User Manual. Contents

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual

The Development of CompoNet Gateway with Common Network Interface

ReadyLink EtherNet/IP LDT with RapidRecall. Network LDT - Configuration Manual ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE...

Communication Protocol DeviceNet Interface for Bayard-Alpert / Pirani Gauge and High Pressure / Pirani Gauge BPG400-SD HPG400-SD tira03e1-b (0310) 1

T29 - Safety System Connectivity Help Reduce Cost, Downtime, and Injuries

MICRO-SCREEN DIN Controllers with DeviceNet Trip Output

1782-JDC DeviceNet/Serial Gateway User s Manual

Electronic Valve Actuator. SEVA EtherNet/IP Communication Protocol Setup. User Manual. RCV-UM EN-03 (September 2018)

G5 Weighing Instrument

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

New ADAP-KOOL AK-CT 200. One. Hardware. for over 300 tray variants. Refrigeration and A/C Controls Division Date 1

G3 Series EtherNet/IP TM Technical Manual

Series SD6 with DeviceNet (Addendum)

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or

Michael Frayne Manager, Product

POINT I/O Family. Chapter. Overview

8903/CN ControlNet Communications Interface

Product Description. Table of Contents

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

DNP3 Router. User Manual A-DNP3R. Document No. D /2018 Revision 1.24

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

FOOD AND BEVERAGE AUTOMATION & ELECTRICAL SOLUTIONS

DeviceNet Expansion Board

Converging Systems Inc.

Vector Drive - Troubleshooting Guide

1. Installation DEVICENET INTERFACE. Install the DeviceNet Interface using the following procedure:

TSN Influences on ODVA Technologies. Steve Zuponcic, Mark Hantel, Rudy Klecka, Paul Didier Rockwell Automation, Cisco Systems.

CTEET003_Programmable Logic Controls CTAG Rubric EET. Some applied skills present

DeviceNet - ODVA Conformance Test Results

How to configure DeviceNet with Anybus NetTool for DeviceNet.

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

SK CU4-EIP-C Part number:

FLEX 5000 Digital I/O Modules

1782-JDO DeviceNet-to-Optomux Gateway User s Manual

NA User Manual. Copyright(C) * CREVIS Co.,Ltd * Support * URL :

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

DeviceNet. Manual / Users Guide. Part No , Doc. No Ver. 00

Process and Power Control

Tutorial. COPYRIGHT 2014 IGE+XAO. All rights reserved TUTORIAL. Your first steps with SEE Electrical Expert. The specialist of electrical software

Lowering Lifecycle Costs

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

Transcription:

DeviceNet of Things Use Cases, Value Proposition and Status of Specification John Caspers Rockwell Automation February 22, 2017

DeviceNet of Things The increased popularity of EtherNet/IP and the Internet of Things movement establishes a basis for innovation of new smart Things in the automation world. However, the costs associated with deploying EtherNet/IP prevent it from being successfully deployed on many low end Things such as contactors and push buttons. Enhancing DeviceNet as an in-panel cabling and communication solution for low-end devices will: Lower the cost of deployment below the levels provided by EtherNet/IP Provide greater information delivery capabilities over hard-wired solutions Enhance ease-of-use over existing networked solutions (including DeviceNet) Simplify physical/mechanical connection methods leading to lower panel build costs. Since DeviceNet and EtherNet/IP share the CIP Protocol, DeviceNet of Things enhancements may also help pave the way for future adoption of EtherNet/IP as Ethernet costs continue to decline. 2

DeviceNet of Things Customer Requirements Extensive customer listening sessions resulted in the following key requirements for the DeviceNet of Things: It must be Functional It must simplify in-cabinet wiring for panel builders It must deliver both Network Power to power device electronics and Switched (Control) Power to facilitate the actuation of Contactors and Relays It must support Non-Safety and Safety devices on the same wire It must be Simple to use It must use a single easy to use media connector It must include a simple (or no) network commissioning methodology It must eliminate the need for media trunk and drop distance calculations It must be Economical It must use low cost media It must allow for a reduction in price and size of typical products It must allow the use of commercial off-the-shelf power supplies It must result in a lower total cost of ownership than hard wired solutions 3

DeviceNet With an Easy Button Easy Node Commissioning (Auto-Commissioning) (Fixed Baud Rate) NO Scan List or Auto-Mapping Easy Device Configuration (Default of No Configuration) Easy System Integration (Nodal Geography Identification and Reporting) Simplified Media Selection (IDC Ribbon Cable) (NO Distance Calculations) Enhanced P/S Architecture (Configurable Power Taps) (Network & Control Power) (Single Standard 24Vdc Supply) 4

Select Network + Network CAN + CAN Control + Control 7 Wire Keyed Cable Includes Network Power to power device electronics Switched (Control) Power to actuate contactor coils CAN lines for CIP messaging Select Line for simple sequential network service delivery This allows us to be able to discover the nodal geography Node uprocessor Node uprocessor Node uprocessor In Out In Out In Out DeviceNet of Things Media Basics New Insulation Displacement Connector No need for special crimping tools Can support the cutting of multiple conductors in support of the Power Supply Tap Architecture. Select NP+ CAN+ CAN- NP- SP- SP+ 5

Nodal Geography Discovery A Nodal Geography is a complete ordered set of device keys for all devices on a network. In a subnet system, the CIP Router device will include the ability to discover the entire subnet Nodal Geography and deliver it to a commissioning tool or processor on the other side of the gateway for display. EtherNet/IP Network Switch CIP Router 1 2 3 DoT Configuration Tool Actual Network Geography Information 4 5 6 7 8 9 10 Relays Starters PushButton DeviceNet of Things Network 6

Nodal Geography Discovery Select Line Messaging Select Network + Network CAN + CAN Control + Control Node uprocessor Node uprocessor Node uprocessor In Out In Out In Out Select Line Messages are received on the Select In line. The device services the message, and after processing is complete, the message is retransmitted on the Select Out line. The result is sequential message delivery from left to right. Select Line Message Format Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 1 Validation Reserved Command Reserved Sync Time (ms) 0 Reserved Sync (0) Command 3 6 9 Reserved (0) Validation 12 15 18 21 24 27 30 33 36 39 42 45 48 51 Select Line Message Timing 3 msec. per bit 7

Relevant Nodal Geography information is reported in 2 new Group 5 CAN messages: Device Key messages Offline Status messages Production of the new Group 5 messages is allowed when a device is in the Communication Faulted state. Nodal Geography Discovery Group 5 Messaging IDENTIFIER BITS HEX IDENTITY USAGE 10 9 8 7 6 5 4 3 2 1 0 RANGE 0 Group 1 Message ID Source MAC ID 000-3ff Message Group 1 1 0 MAC ID 1 1 Group 3 Message ID Group 2 Message ID 400-5ff Message Group 2 Source MAC ID 600-7bf Message Group 3 Group 4 Message ID 1 1 1 1 1 7c0-7ef Message Group 4 (0 2f) 1 1 1 1 1 1 1 0 Group 5 7f0-7f7 Message Group 5 Message ID 1 1 1 1 1 1 1 1 X X X 7f8-7ff Invalid CAN Identifiers Byte 7 6 5 4 3 2 1 0 0 Vendor ID (low byte) 1 Vendor ID (high byte) 2 Device Type (low byte) 3 Device Type (high byte) 4 Product Code (low byte) 5 Product Code (high byte) 6 Major Revision 7 Minor Revision Device Key Message Format Byte 7 6 5 4 3 2 1 0 0 MAC ID 1 Duplicate MAC ID Faulted Status 2 Serial Number (low byte) 3 Serial Number (byte 1) 4 Serial Number (byte 2) 5 Serial Number (high byte) Offline Status Message Format 8

Nodal Geography and the DoT Commissioning Object The DeviceNet of Things Commissioning Object: Initiates Select line messaging Captures, Stores and Reports an Actual Nodal Geography Accepts a Reference or Desired Nodal Geography Facilitates Automatic Node Commissioning based on a Reference Geography The DeviceNet of Things Commissioning Object may be implemented in A CIP Router A DeviceNet of Things Master Scanner A DeviceNet of Things Commissioning Tool In all cases, the DeviceNet of Things Commissioning Object resides in the First or Leftmost node on the network whose MAC ID is fixed at Address 0. 9

Attribute 1 Reflects the Nodal Geography Status Attributes 2-66 store an Actual Geography i.e. the discovered geography of an actual network. Attributes 182-246 accept and store a Reference or Desired Geography, often delivered by a DoT Commissioning Tool. Attribute 99 Enables/ Disables automatic commissioning based on a Reference Geography. DoT Commissioning Object Instance Attributes Attribute ID Need in Implementation Access Rule NV Name Data Type Description of Attribute 1 Required Get V Status WORD Status of the object 2 Required Set NV Number of Nodes in Reference Geography 3 Required Set NV Reference DoT Commissioning Object Node USINT STRUCT Bit 0 = Reference Data Ready Bit 1 = Actual Data Ready Bit 2 = Geography Mismatch Bits 3-15 = Reserved Number of nodes in the stored reference geography for the network Structure describibng the identity of the expected device at MAC ID 0 4 Required Set NV Reference First Position STRUCT Reference geography information for first node (position 1) on network 5 Required Set NV Reference Second Position STRUCT Reference geography information for second node (position 2) on network 66 Required Set NV Reference Sixtythird Position STRUCT Reference Geography information for 63rd node (position 63) on network 99 Required Set NV Auto Apply Reference Geography BOOL Enables the Auto-Commissioning of DoT network devices in a System based on the Reference Geography. 182 Required Get V Actual Number of UINT Actual number of Nodes on the network Network Nodes 183 Required Get V Actual This Node UINT Actual geography information for this node. 184 Required Get V Actual First Position STRUCT Actual geography information for first node (position 1) on network 185 Required Get V Actual Second Position STRUCT Actual geography information for second node (position 2) on network 246 Required Get V Actual Sixtythird Position STRUCT Actual geography information for 63rd node (position 63) on network 10

Nodal Geography Delivery Auto-Commissioning In a subnet system, the CIP Router device will also be able to receive an entire Reference subnet Nodal Geography from a commissioning tool or processor, and compare it to the actual Nodal Geography. If the network geographies match, automatic network commissioning can be accomplished for the entire network. EtherNet/IP Network Switch CIP Router 1 2 3 DoT Configuration Tool Reference Nodal Geography Information 4 5 6 7 8 9 10 Relays Starters PushButton DeviceNet of Things Network 11

Flexible Addressing NOT Auto-Addressing Various addressing schemes can be implemented in the DoT Configuration Tool and full Reference Geographies can be Applied at the network level. Example addressing schemes include (but are not limited to): 0 1 2 3 4 0 1 2 3 4 Sequential Full Addresses are sequential based upon geographical location 8 7 6 5 5 6 7 8 of device on the cable Sequential Light Addresses are sequential based on the next available node address for each newly added device on the cable 0 0 1 2 3 4 5 63 6 7 63 63 1 2 3 4 7 63 5 6 8 63 63 9 Sequential by Device Type Addresses are sequential in a device type-specific range. Traditional Node Commissioning Allows OEM s to set Fan=20, Pump=10 1 2 3 4 21 0 22 23 11 12 13 0 1 2 3 4 20 5 6 63 25 10 63 63 12

Auto-Device Replacement and Geographic Device Keying The replacement of a node with a compatible device will include the ability to check that the replacement device was placed on the network at the same geographic position as the original device before the Auto Device Replacement feature is triggered, effectively adding a new and important device keying criteria. Relay at MAC ID 2 Is to be replaced Compatible relay in out-of-the-box state placed here 1 2 3 4 5 6 7 8 9 1 3 4 5 6 7 8 9 63 Relays Starters Push Button An Auto-Device Commissioning operation is triggered when: the disappearance of a node in the Reference Geography is detected AND a new node comes on-line AND comparison of the Actual and Reference Geographies shows that they are compatible (they match). Relays Starters Push Button If a compatible node is detected at the same position as the missing node, the node is commissioned automatically. If a compatible node is detected at a different geographic position, no action is taken. (Illustrated on the right above). 13

Auto-Device Replacement and Geographic Device Keying Consider a system where 2 adjacent nodes are to be replaced. These 2 relays are to be replaced 1 2 3 4 5 6 7 8 9 Single compatible device is detected Relays Starters 2 compatible devices are detected Push Button 3 compatible devices are detected 1 63 3 4 5 6 7 8 9 1 63 CF 3 4 5 6 7 8 9 1 63 CF CF 4 5 6 7 8 9 Relays Starters Push Button Relays Starters No Action New devices are Auto-Replaced Push Button Relays Starters No Action Push Button 14

Power Architecture Four Power Tap Styles x x x x 1 st Tap - Puncture NP & SP and inject Network Power left (bridge) and right (nodes) & Switched Power to right NP & SP - Puncture NP & SP and inject Network Power left (bridge) and right (nodes) & Switched Power to right NP Only - Puncture NP and inject Network Power to right (SP is not punctured and passes thru) SP Only - Puncture SP and inject Switched Power to right (NP is not punctured and passes thru) Gateway w Terminator First Tap SP Tap NP Tap SP & NP Tap Terminator Switched Power 1 Switched Power 2 Switched Power 3 Network Power 1 Network Power 2 Network Power 3 15

NP+ IN NP- IN SP+ IN SP- IN Supply Voltage Logic Controlled Tap Type Switches Fuse V sense R1 R3 Filter/ Limiter/ Boost Tap Type Selector Switch Processor I Sense CAN+ CAN- DNoT Interface Switch Logic Controlled Tap Type Switches R2 Adjustable Smart Power Taps LEDs V Sense NP+ NP- NP+ OUT NP- OUT SP+ OUT SP- OUT Switch R1 Connects NP IN to NP OUT Switch R2 Connects Voltage Supply to NP OUT Switch R3 Connects SP IN to SP OUT Switch R4 Connects Voltage Supply to SP OUT Fuse Filter/ Limiter/ Boost Mandatory I Sense Switch Logic Controlled Tap Type Switches R4 Optional V Sense SP+ SP- The tap is an active node on the network. This allows the tap to report diagnostic information such as CIP Energy data for each power segment. 16

Network Power + CAN + CAN - Network Power - Select Switched Power - Switched Power + Smart Terminators Improper termination of DeviceNet networks is a common problem in the field. VI sense Power Supply CAN Transceiver Microprocessor 120 ohms VI sense Since the cost of simple DoT nodes will be small (Cortex M0+ micros with ample Flash, RAM, CAN and peripherals are available for less than $1), it makes sense to provide smart terminators so that tools can report improper network termination. 17

To protect the investment vendors have made in DeviceNet, a Smart Drop can be developed to extend the functionality of existing products so they can fully participate in a DoT network. It Smart Drops would act as a simple DeviceNet to DeviceNet router. The DeviceNet of Things side of the router would occupy a node address on the DeviceNet of Things network and would be able to participate in Select line services and produce Group 5 messages. P/S SP/NP Relays SP Starters Push Buttons Smart Drop DOT Push Button uprocessor Traditional DeviceNet Media Traditional DeviceNet Device Smart Drop uprocessor This approach would not affect the DeviceNet of Things media length budget since the drop to the traditional device is a separate point to point DeviceNet network. Select Network + Network CAN + CAN Control + Control 18

Specification Status To date, the DeviceNet of Things SIG has approved the following specification enhancements and forwarded them to the System Architecture SIG for review: DSE 0001-115 DeviceNet of Things Overview including: An overview work items for the SIG Additions to Volume III Chapter 1 DeviceNet Adaptation of CIP. Feedback from the System SIG is pending. DSE 0001-114 DeviceNet of Things Feedback from the System SIG is pendingobjects including: Volume III Chapter 2 protocol updates related to Group 5 and Select Line messaging Volume III Chapter 5 updates to the DeviceNet Object Volume III Chapter 5 additions to define the DeviceNet of Things Link Object and the DeviceNet of Things Commissioning Object. Volume III Chapter 7 EDS file definition updates Feedback from the System SIG has been received, updates are complete, forwarded back to the System SIG for further review. CIPSE 0001-252 DeviceNet of Things Hooks including: Volume 1 Chapter 5 and Chapter 7 tweaks in support of the DeviceNet of Things. Feedback from the System SIG has been received, updates are complete, forwarded back to the System SIG for further review. CIPSE 0001-256 Pushbutton Portfolio Profile Adds a new device profile to support Pushbuttons, Selector Switches and Pilot Light indicators to Volume 1 Chapter 6 Feedback from the System SIG is pending. 19

Specification Status (continued) The DoT SIG has engaged the DeviceNet Physical Layer SIG to define the needed specification enhancements to support the new media, connector and power supply requirements. The following specification enhancement is being prepared: DSE 0798-001 DeviceNet of Things Physical Layer Further related specification enhancement work to support new low-end devices for the DeviceNet of Things is being done in the ODVA Motor Control and Circuit Breaker SIG, most notably: CIPSE 0001-257 Circuit Breaker Profile Adds a new device profile to support Circuit Breakers to Volume 1, Chapter 6 CIPSE 0001-258 Circuit Breaker Objects Adds a new Circuit Breaker Supervisor Object definition to Volume 1, Chapter 5 Various other CIPSEs to better support component based motor starters and other devices in the ODVA Hierarchy of Motor Control Devices. The DeviceNet of Things SIG will continue its work as follows: Define a Power Tap device profile. Define a Smart Terminator profile. Look into the development of other new device profiles as needed. Produce a DeviceNet of Things Conformance Test Specification. 20

THANK YOU