Instruction Manual FH

Similar documents
Instruction Manual FH EXT

Instruction Manual FH EXT

Instruction Manual FH

Instruction Manual FH

Operating instruction Platform scale

FG-7000 Digital Force Gauge Operation Manual

FG-7000L Digital Force Gauge Operation Manual

FG-3000 Digital Force Gauge Operation Manual

NIDEC-SHIMPO INSTRUMENTS

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

FG-3000R Digital Force Gauge Operation Manual

Series FGE-XY Force Gauges Operation Manual

NIDEC-SHIMPO INSTRUMENTS

Operating instructions Precision/ compact balances and platform scales

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

-Direct.com FG-3000 Digital Force Gauge Operation Manual

Please refer to Page 3.

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD

Instruction Manual Digital Sound Level Meter

Digital Measurement Metrology, Inc PRECISION IS OUR VISION

EB300 Weighing Scale Operation Manual

Operating Instructions STX Series Digital Strap Tension Meter

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL

Laboratory Balances. Standard. Option (addit. price) KERN Your DKD Calibration Partner. Your specialist dealer

NOTE. This is warning & caution mark. This is hazard alert mark. This is useful information mark

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

TTC Series Torque Tool Tester Operation Manual

IDS-801 Series Compact Bench Counting Scale. User Manual

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

EHC-WF. User/Technical Manual. Contents subject to change without notice

0.01kV (0 to ±0.99 kv)

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Operating Instructions LX-Series Digital Tension Meter

Operating Instruction PPC-04 /2

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Digital Torque Gauge. User s Manual

! User Manual Rev. 1

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

DFS Series User s Manual (5N-1000N Capacity)

BW/BWS Weighing Indicator

Hand-held thermometer Model CTH6200

Counting Scale. HC-3Ki. HC-15Ki HC-6Ki WM+PD

GMH Operating Manual for Digital Quick-Response Thermometer

Weighing Indicator Service Manual V1.24X


EW EG-(N) Laboratory Balance. Standard. Option (addit. price) KERN Your DKD Calibration Partner. Your specialist dealer

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

User s Guide. Series 2 DIGITAL FORCE GAUGES

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

NOTES TABLE OF CONTENTS

HHTQ35 Digital Torque Gauges

BW 2050 Manual. Weltech Interna onal Limited INTRODUCTION

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

CAUTIONS... 4 INTRODUCTION...

Digital Quick-Response Thermometer

Manometer. (Over- /Under- And Difference Pressure) Operating Manual GDH

Trade Approved Version NMI: S520

icore Kiosk system Installation Guide

TNP Digital Torque Meter Operation Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual.

CONTENTS. PRECAUTIONS Introduction Installation... 7

Operating instruction Compact balance

TWP series. Weighing Indicator Service Manual

Standard Model Digital Force Gauge ZTS series

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

Operating instruction Precision balances


Hand-Held Pressure Indicator

Operating instruction Compact balances

1.0 Description. 2.0 Unpacking. 3.0 Installation

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

GMH to 1300 mbar absolute Version 4.7

B e n c h S c a l e KPZ 2E-06-N Stainless Steel DIN

Hand-held thermometer Model CTH6200

Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version)

CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

INSTRUCTION MANUAL. Models: H100 Light Meter

805HP. Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website:

MWP SERIES. High Precision

Standard Model Digital Force Gauge ZTS series

Precision hand-held pressure indicator Model CPH6400

Cautions for Your Safety

TWP-W. Weighing Indicator Service Manual

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Digital Force Gauge INSTRUCTION MANUAL. Model: DS2

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Technical Parameter... 4 Installation and Connection... 5

Digital Weighing Indicator XK3190-A12 User Manual

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

QC-3265 Checkweigher User s Manual

MX-T6-PRO/S Tube Rollers

Operating Instructions SECUTEST SI /12.10

KERN Version /2015 GB

Transcription:

Sensor Outside Thank you for buying a SAUTER force gauge. We hope you are pleased with your high quality force gauge with its big functional range. If you have any queries, wishes or helpful suggestions, do not hesitate to call our service number. Important annotation: By pressing the RESET key (on the right side of housing, see illustration on the left), individual settings and memorised values can be re-set or erased, in example for a new start of the after an operating error. Data in mm Sensor Outside means the cell is outside the body. 1. Included in Delivery - SAUTER, incl. rechargeable battery - Carrying Case - Charger - 5 pcs. M3x 8 screws Set Length of cable between display and sensor: 2500 mm Pilot lamp LCD Measurement Terms: Track = continuous measurement Peak = Capture of the maximum value Dimensions of Sensors (from 200k on inquiry) 4-pin Force Sensor sensor bushing Force sensor, M6- RS thread 232 port 2. Working Conditions 10 C to 30 C / 15% up to 80% humidity _SO-BA-e-1217 1

3. Electrical Power Supply Either by rechargeable battery or current power supply - Press short: Select unit: N, kg or lb - Press for 2 sec.: Display return Current power supply: - Connection by power adapter - Rechargeable batteries are charged simultaneously Rechargeable battery pack for mobile applications: - Type: Ni 8.4V / 600 mah - Charging time: approx 1 hour 4. Technical Data - Accuracy: ± 0,5 % of Capacity - Data Sampling Rate: 2.000 Hz - Weight: 640 g ZERO: SET: Three functions: - Zeros the measuring result (Tara function) - Cleans the peak value (in Peak mode) - Saves a setting (in SET mode - 1 x Press: Upper Limit [HidT / Hi Lt]. To change press: or (see section High/Low Limit function) Hi Lt 5. Operation Display - 1 x Press: Lower Limit [LodT]. To change press or (see section High/Low Limit function ) Lo dt - 1 x Press: Minimum limit to save peak values in the s memory. [LE.SET / Lo Pe]. Please see section Min Limit Peak Save. To change press: or (Only in Peak-Mode active) (see section min. limit peak save) Lo Pe (1) Measuring Result (2) Measuring Units (3) Activation of PRINT Function (4) Indication of power charging status PEAK or AUTO-PEAK Mode (5) Average value of stored peak values (6) Force direction (7) Occupancy of storing spaces (8) AVERAGE- or Saving Mode Operating keys ON / OFF: ON / OFF key (For ON, press 1 sec.) - 1 x Press: Sets the Auto-STOP force value that stops the movement of a test stand. Adjustment of the force value. To change press: or (only active in Battery- Mode ) StoP - 1 x Press: Sets the AUTO-OFF force value that stops the movement of a test stand. To change press: or (Only in Battery- Mode active) P.OFF - 1 x Press: Peak-Freeze-Time [PE.2E / A.PE / HoldT]: Time period in which a peak value is being shown in the display in sec. To change press: or UNIT: _SO-BA-e-1217 2

HoldT - 1 x Press: Data Transfer [rs232] to PC (PC) or to the printer (Print) or (in version U 5.1) to the test stand (stand) rs232 - PC: Pressing SET once: Saves the Settings - PRINT: Pressing SET twice: sending data to the printer - STAND: Pressing SET three times: sending a signal to the Test Stand to stop its movement (in version U 5.1) To set these limit values, please see the SET Menu in section Operating keys. Measurement (Track Modus) Display (1) shows the continuous force in a defined direction (6) To zero the display, press: Back Light: PEAK: Three functions - Track mode (continuous measurement) - Peak mode (capture of maximum values) - Auto-Peak mode, same as Peak-mode, only without the Min limit peak save function Peak-Hold Function (Peak Mode) Please press: Auto-Peak-Hold-Function(Auto-Peak Mode) Please press: MEMORY: Min. limit peak save Saves the peak values to calculate the average value (please see section Memory mode DELETE Function Deletes stored peak values (only in Memory mode active) PRINT: Sends the stored peak values to a PC or Printer (please see section Data Output ) This function allows to eliminate unwanted Pre-Peak values that are lower than the main peak value (Fp). The Min limit peak save value (Fo) takes care, that these Pre-Peak values are not saved. High / Low limit function LEDs to display OK / NOT OK Tests Lower than lower limit OK OK Higher than higher limit The Min limit peak save function is only possible in Peak-Mode. To set this Min limit value, please see the SET Menu in section Operating keys. Memory mode and average value (from up to 10 peak values) Saving peak values in the This function allows efficient testing of OK / NOT OK measurements of similar or identical testing objects. A lower and an upper limit value can be defined. The compares the individual measuring results with these limit values and shows the OK or NOT OK result by green or red light diode and by sound. Activating the AUTO PEAK Function by PEAK key Deactivating the Average Function by MEMORY key Now, all peak values are stored automatically in the _SO-BA-e-1217 3

To browse through the stored values, please use the or keys. (The values will be shown in the upper display segment) By pressing the MEMORY key, the average value of the stored peak values can be shown (in the upper display segment) The you have acquired serves to determine the measuring value of the material to be measured. It is intended to be used as a non-automatic, i.e. the material to be measured is manually and carefully attached at the. The measuring value can be read off after a stable measuring value has been obtained. To delete every stored value, press the -key in the AVERAGE-Mode Inappropriate use 6. Configuration of RS 232 SUB-D 9pm Pin Signal Illustration 2 TxD Output signal 3 RxD Input signal 5 GND Ground 6 +1.6 to + 2 V Over upper limit 7 +1.6 to + 2 V Lower than lower limit 8 +1.6 to + 2 V OK 6.1 Output Protocol RS-232 Parameter Baud rate: 9600 Data-Bit: 8 Parity: none Stop-Bit: 1 The measured value is requested by the PC by the ASCII Sign 9. The measured value that comes from the has this format: e.g. 0011.70 means -11,70 Newton, if Newton is the selected unit ----- > the other 6 places describe the measured value as ASCII-Signs > the first place describes the direction of the force (0 = minus = Pressure; 1 = plus = Tension) Do not use the for medical measurements. In the case that small quantities are removed or added to the material to be measured, incorrect measuring results can be displayed due to the stability compensation inside of the. (Example: Slow draining off of liquid from a container suspended from the ). Do not attach a continuous load. This can damage the measuring unit as well as the parts, relevant to safety. Prevent jolts, torsion and oscillation (e.g. by appending slopingly) of all kinds. Be sure to prevent overloading the in excess of the stated maximum load (max.), minus any tare weight that may possibly exist. This could damage the (risk of breakage). Important: Always make sure that there are no people or materials below the load that could be injured or damaged! The is not suitable for measuring people. Do not use as baby scales! The does not comply with the medical product law (MPG). Never operate the in hazardous locations. The series design is not explosion-proof. Structural alterations may not be practised to the. This can lead to incorrect measuring results, faults concerning safety regulations as well as to destruction of the. The may only be used in compliance with the described guidelines. Varying areas of application/ planned use must be approved by SAUTER in writing. Guarantee The guarantee is not valid following non-observation of our guidelines in the operating instructions alteration to or opening of the device mechanical damage and damage caused by media, liquids natural wear and tear inappropriate erection or electric installation overloading of the measurement equipment or: 1021.15 means +21,15 N (Tension) 7. Warning Intended use Monitoring the test substances The metrology features of the and any possible available adjusting weight must be checked at regular _SO-BA-e-1217 4

intervals within the scope of quality assurance. For this purpose, the answerable user must define a suitable interval as well as the nature and scope of this check. Information is available on the home page (www.kern-sohn.com) with regard to the monitoring of test substances and the test weights required for this. Test weights and s can be adjusted quickly and at a reasonable price in KERN s accredited DKD calibration laboratory (return to national normal). Fundamental safety information Do not use the hanging to transport loads. Prevent jolts, torsion and oscillation (e.g. by appending slopingly) of all kinds. Never use the hanging over the maximum permitted weight (!!Danger of breaking!!). Always make sure that there are no living beings or materials below the load that could be injured or damaged. The hanging electronic s from the SAUTER are only suitable for hand-held use or use in a test stand. They are not suitable for hanging from a mechanical hook, e.g. a crane hook. Observe the information in the operating instructions Please read the operating instructions carefully before setting up and commissioning, even if you already have gained experience with SAUTER s. Staff training The device may only be operated and looked after by trained members of staff. Major display deviations (incorrect measuring results) are possible if electromagnetic fields occur as well as due to static charging and instable power supply. It is then necessary to change the location. Unpacking Carefully remove the from its packaging, remove the plastic wrapping and position the in its intended working location. 8. CE Declaration of conformity _SO-BA-e-1217 5

Adjustment Procedure 1 Start the 2 Enter the procedure 3 Instrument Type a (Back to the normal mode???) 4 Select the type 5 Save type 6 Enter the sequence 7 Choose the weight 8 Save the weight 9 Attach the weight to the (by hanging) Press ON/OFF Directly after pressing ON/OFF, press PEAK and PRINT together for more times and very short intervals until the red light is on. Press SET Directly after pressing PEAK + PRINT (If you are in the operation mode again, the has to be shut off. Start again with 1. Eventually pressing the buttons faster) Press Press SET Press MEMORY Press UNIT and with specify the calibration weight in Newton (X kg * 9,81) Press SET and UNIT simultaneously Press ZERO The green light is on The lower red light is on XXX N is shown The correspondi ng value to the instr. appears in the display The upper red light is on The weight is written in the display The changes to operation mode. Adjustment procedure is finished _SO-BA-e-1217 6