Huawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD.

Similar documents
SmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SmartLogger2000 Quick Guide. Issue: 01 Part number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN KTL-M0 Quick Guide (Europe Edition) Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 14 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL, 40KTL) Quick Installation Guide. Issue: 05 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 13 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL, 36KTL, 40KTL)-US Quick Guide (Mounting Bracket Supplied with the SUN2000, Amphenol Helios H4)

SUN2000-(55KTL, 60KTL) Series Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

String Inverter (SUN2000-8/12KTL)

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted

sonnen Installation Practical

SmartLogger1000. User Manual. Issue 09. Date HUAWEI TECHNOLOGIES CO., LTD.

SUN KTL-US-HV-D0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

SUN2000-(33KTL-A, 36KTL, 42KTL) Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

About Huawei. A Global Leader of ICT Solutions

SUN2000 (8KTL-28KTL) User Manual. Issue 09. Date HUAWEI TECHNOLOGIES CO., LTD.

Surge Protection for Surveillance Systems

SUN2000-(33KTL-A, 36KTL, 42KTL) User Manual. Issue 03. Date HUAWEI TECHNOLOGIES CO., LTD.

ABB Three Phase String inverter

SmartACU2000B Smart Array Controller Quick Guide (with no PID Module, 800 V AC) Issue: 05 Part Number: Date:

FusionSolar. Residential Smart PV Solution. FusionSolar

SUN2000-(55KTL, 60KTL) Series. User Manual. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

SmartLogger2000-(10-C, 11-C) User Manual. Date HUAWEI TECHNOLOGIES CO., LTD.

SolarEdge Installation Guide MAN Cover goes here (right-side [odd] page) hotovoltaikforum.co

SUN KTL-US-HV-D0. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(25KTL, 30KTL)-US. User Manual. Date HUAWEI TECHNOLOGIES CO., LTD.

About This Guide SolarEdge Installation Guide for Three Phase Inverters EU Version 1.5

F1000 User's Manual. (Version: V1.01)

SmartPSB2000L Smart PV Safety Box Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Overvoltage Protection Devices

Modular Connectors 75

PanelView Plus/VersaView CE Terminals and Display Modules

Overvoltage Protection Devices

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

SmartACU2000B Smart Array Controller Quick Guide (with PID Modules, 800 V AC)

Huawei FusionHome Smart Energy Solution

Connecting a Cisco Output Module

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

FusionSolar Smart PV Solution

Manual Version: V1.00. Video Decoder Quick Guide

Solis Single Phase Inverter

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR CPE-80

InnoMedia Business VoIP ATA Models

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

PV Grid Connected. PRIce LIST valid from 1st Januar 2014 by Steca

Grid PV Inverter M30A & M50A. The power behind competitiveness Delta M30A & M50A. Product Features

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Quick Installation Guide

Technical Information SMA STRING-MONITOR SSM-U-XX10 / SSM-U-XX15

SUN2000-(33KTL, 36KTL, 40KTL)-US. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

Preparing to Install the VG248

FusionSolar Smart PV Solution

GCI-5K INSTALLATION AND OPERATOR S MANUAL

INSTALL INSTRUCTIONS RSXMR-9886-P-48

Ethernet Network Card Installation and Operation Manual

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

MIC-2 MKII, Multi-instrument DATA SHEET

Solis Single Phase Inverter

Smart Energy Center. Simple & Easy. Higher Revenue. Battery Ready. Safe & Reliable

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

User Manual V1.0. User Manual of Z10 Internal Data Collector

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

User Manual. 3KW/5KW PV Inverter

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

RTU560 Connections and Settings DIN Rail RTU 560CIG10

SolarVu Installation Guide for Sungrow SG60KU-M Inverter

Chameleon Stand-alone

User Manual. Solar Inverter for Water Pump

M215 Microinverter Installation Planning

SolarEdge. Distributed Solar Power Harvesting Systems. Installation of the SolarEdge System SolarEdge

String monitoring with CMS - Circuit monitoring system Increased productivity and improved maintenance of PV systems

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA

PM Series Power Meter

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.


CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

Smarter Energy for a Better Life. Huawei FusionHome Smart Energy Solution. For Homeowners

SUNCLIX Connection technology for photovoltaics

SUN2000-(33KTL, 36KTL, 40KTL)-US. User Manual. Issue 04. Date HUAWEI TECHNOLOGIES CO., LTD.

ISOMETER isopv with coupling device AGH-PV

Solis Three Phase Inverter

Solis Three Phase Inverter

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Contents. 1. About this Manual Scope of Application Target Reader Abbreviations Introduction...

Omega 4K/UHD Scaler for HDBaseT and HDMI with USB

Operating tunnels safely Overvoltage protection for critical systems in tunnels

Overvoltage Protection Devices

Smarter Energy for a Better Life. Huawei FusionHome Smart Energy Solution. For End Users

Transcription:

Huawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD.

Contents Overview of the Product Range Huawei Solar Inverter Technical Information Huawei Smartlogger Technical Information NetECO Portal Brief Overview HUAWEI TECHNOLOGIES CO., LTD. Page 2

Huawei Inverter Family Full Range of Huawei Inverter Products New On-Grid Solution SUN2000 @400V 8/12kTL 17/20/23kTL 33KTL 36kTL Small Commercial PV System SUN2000 @480V MV 28kTL 42kTL Large Commercial PV Plants Smart Logger & NetEco Smart Logger imanager APP Utility PV Plant HUAWEI TECHNOLOGIES CO., CO., LTD. LTD. Page Page 3 3

Contents Overview of the Product Range Huawei Solar Inverter Technical Information Huawei Smartlogger Technical Information NetECO Portal Brief Overview HUAWEI TECHNOLOGIES CO., LTD. Page 4

Recommended Design Specification: *To insure the modules STC per string does not exceed 1000V. HUAWEI TECHNOLOGIES CO., LTD. Page 5

Recommended Design Specification: HUAWEI TECHNOLOGIES CO., LTD. Page 6

Recommended Fuse Specification: HUAWEI SUN2000 Rated AC Power (KW) Rated Max AC Power (KW) Max output Current Recommended Fuse Spec 8KTL 8 8.8 12.8A 20A 12KTL 12 13.2 19.2A 32A 17KTL 17 18.7 27.2A 40A 20KTL 20 22 32.0A 50A 23KTL 23 23 33.5A 50A 28KTL 27.5 27.5 33.5A 50A 33KTL 30 30 48.0A 63 A HUAWEI TECHNOLOGIES CO., LTD. Page 7

Circuit Diagram Huawei SUN2000 17, 20, 23 & 33KTL AC: 3P+N+PE AC: 3P+N+PE 2 MPPT SUN2000-8KTL/12KTL 3 MPPT Huawei SUN2000 8 & 12 KTL AC: 3P+PE SUN2000-17KTL/20KTL23KTL Huawei SUN2000 28KTL & 33KTL New firmware which will be available from March 2016 3 MPPT SUN2000-28KTL HUAWEI TECHNOLOGIES CO., LTD. Page 8

Recommended AC Cable: HUAWEI TECHNOLOGIES CO., LTD. Page 9 2/25/2016 RS 9

Notes of AC Connector(Amphenol C16/3) Included & Cabling 1. 4/6 mm² flexible wires in common,10 mm² optional of stranded circular non compacted conductor (class 2 acc. to IEC60228), minimum 7 wires in the conductor. 2. When the outer cable diameter is more than 16mm, strip a seal ring from the cable sealing cover interior. 3. To remove an AC output connector, press the locking plate on the coupling nut using a flat-head screwdriver 4. If PGND cable is already installed with screw at the inverter, PE wire of the AC connector is not necessary. In this case, 3P+N is recommended for SUN2000 8-23KTL, 3P for SUN2000-28KTL. HUAWEI TECHNOLOGIES CO., LTD. Page 10

Notes of DC Connector(Amphenol H4) Included & Cabling 4/6mm2 compatible Female stamped and formed contacts Male stamped and formed contacts Improvement Available now 1.98mm->1.84mm Essential Tool HUAWEI TECHNOLOGIES CO., LTD. Page 11

Notes of RJ45 Outdoor Connector Included & Cabling 1. 2 Sets for each inverter, RJ45 plug without load bar 2. 24 AWG outdoor shielded network solid wire cables recommended and external diameter of 4.5 mm to 7.5 mm 3. Alternative choice to buy RJ45 plug with load bar for solid and stranded conductors 24/26AWG EFB-Elektronik RJ45-CAT6-Crimp-STP-Stecker High Performance Modular Plugs von TE Tyco Electronics (AMP Netconnect) Shielded / 8/8 / Round Solid 5-5699550-2 (500/ Box) 5699550-3 (100/ Box) (for solid conductors) Shielded / 8/8 / Round Solid 5-5699552-2 (500/ Box) 5699552-3 (100/ Box) (for stranded conductors) Recommended Outdoor Cable: Etherline FD P BK CAT.5 (CE217489) 4x2x AWG26/19 HUAWEI TECHNOLOGIES CO., LTD. Page 12

Surge protection 10kA Class/Type II DC and AC Integrated SPD Tripping device DC side SPD I n is 10kA AC side SPD I n is 10kA System design recommendation: 1. The SUN2000 inverter reaches level II protection level on the DC side, and is able to handle typical inductive lightning shocks to be faced in PV system. In series with tripping device, when SPD leakage current increase it will be tripped and prevent catching fire.therefore, no separate SPD component is required on the DC side. 2. The SUN2000 inverter reaches level II protection level on the AC side, and is able to handle normal electric surges. However, if the installation site is expected to face frequent thunderstorm weather, and if the AC wiring is very long, it is recommended to add separate higher grade SPD component in the AC combiner box. HUAWEI TECHNOLOGIES CO., LTD. Page 13 2/25/2016 RS 13

Residual Current Protection Integrated in SUN2000 series Inverter for Safety Residual current: means the current between inverter and the PE(protecting earth). Safety requirement VDE0126-1-1 defines the residual current value. It is forced requirements for the inverters. 30mA definition is to avoid electrical strike to human beings 300mA definition is to avoid catching fire in the buildings PV Array Discrete capacitor Inverter AC distribution box Grid PE HUAWEI TECHNOLOGIES CO., LTD. Page 14

Product Appearance- Generation 1 Front Bottom Side HUAWEI TECHNOLOGIES CO., LTD. Page 15

Product Appearance- Generation 1 1 DC switch 2 Ventilation valve 3 DC input port (positive) 4 USB port 5 RS 485 IN port 6 RS485 OUT port 7 AC output port 8 Ground bolt 9 DC input port(negative) HUAWEI TECHNOLOGIES CO., LTD. Page 16

Product Appearance- Generation 2 Front Back Side HUAWEI TECHNOLOGIES CO., LTD. Page 17

Product Appearance- Generation 2 HUAWEI TECHNOLOGIES CO., LTD. Page 18

Recommended Design Specification: HUAWEI TECHNOLOGIES CO., LTD. Page 19

Installation of Sun2000- On the wall (Video) HUAWEI TECHNOLOGIES CO., LTD. Page 20

Installation of Sun2000- On the support SUN2000 can also be mounted on the support in same steps. Note: The distance between the inverters can be less than indoor application (10 cm recommended). HUAWEI TECHNOLOGIES CO., LTD. Page 21

Installation Mounting Install the inverter upright or at a maximum back tilt of 15 degrees to facilitate heat dissipation. Do not install the inverter at a front tilt, excessive back tilt, or side tilt, horizontally, or upside down. HUAWEI TECHNOLOGIES CO., LTD. Page 22

LCD Monitoring Screen & Indicators (1) LCD (2) Indicators (3) Buttons Indicator Status Description PV connection indicator Grid tie indicator Steady green Off Steady green Off The SUN2000 connects to at least one of the PV arrays properly. The SUN2000 disconnects from all PV arrays. The SUN2000 connects to the power grid properly. The SUN2000 disconnects from the power grid. Button Name Function Wireless connection indicator Reserved Reserved (The wireless function is not available in this version.) ESC Return Up Down Confirm Allows you to return to the last page or end an operation. Allows you to go to the upper-level menu or set parameters. Allows you to go to the lower-level menu or set parameters. Allows you to go to a menu or confirm a value. Alarm indicator Steady red Blinking red (on for 0.5s and then off for 0.5s) Blinking red (on for 1s and then off for 4s) A critical alarm is generated. A minor alarm is generated. A warning is generated. HUAWEI TECHNOLOGIES CO., LTD. Page 23

LCD Monitoring Main Menu HUAWEI TECHNOLOGIES CO., LTD. Page 24

Contents Overview of the Product Range Huawei Solar Inverter Technical Information Huawei Smartlogger Technical Information NetECO Portal Brief Overview HUAWEI TECHNOLOGIES CO., LTD. Page 25

Overview Web/ Huawei Network Ecosystem (NetEco) Server PC NetEco Local area network (LAN) 3G Router SmartLogger Environment monitoring instrument(emi) RS485 PV Array AC Combiner Transformer Power grid HUAWEI TECHNOLOGIES CO., LTD. Page 26

Appearance 1. Indicator 2. LCD 3. Button Indicator Status Meaning Power Steady green The power supply is normal. indicator Off There is no power supply. Run indicator Blinking green (on for 1s The SmartLogger is working. and then off for 1s) Off The SmartLogger stops working. Alarm indicator Steady red The inverter connected to the SmartLogger generates a major alarm. Blinking red (on for 0.5s and then off for 0.5s) The inverter connected to the SmartLogger generates a minor alarm. Blinking red (on for 1s and then off for 4s) The inverter connected to the SmartLogger generates a warning Off The inverter connected to the SmartLogger is working normally. Buttons Name Function ESC Return button Allows you to return to the last page or end an operation. Cursor Down button Allows you to go to the upper-level menu or set parameters. Cursor Up button Allows you to go to the lower-level menu or set parameters. Confirm button Allows you to go to the menu or confirm the value. HUAWEI TECHNOLOGIES CO., LTD. Page 27

Appearance Port Quantity Function Description POWER 1 Power supply 12 V DC FE 1 Ethernet 100 M Ethernet, connects to a PC or router RS232 1 RS232 (Reserved) AI 2 Analog parameter input 12 V power supply current type (Reserved) DI 4 Digital parameter input Connects to the power grid dispatching signals controlled by dry contacts. DO 3 Digital parameter output Relay output S0.In 1 Connects to pulse output meters. (Reserved) CAN 1 CAN (Reserved) COM 3 RS485 Connects to inverters and other PV devices. USB 1 USB Connects a USB device to download or upgrade HUAWEI TECHNOLOGIES CO., LTD. Page 28

Installation- Desk mounting High conversion efficiency Note: 1. Place the SmartLogger on a horizontal desk, and face the cable connection area downwards. 2. Do not place the SmartLogger in a place that may touch cables. The cables must be secured. HUAWEI TECHNOLOGIES CO., LTD. Page 29

Installation- Connect to inverter High conversion efficiency Recommended Cable CAT 5E outdoor shielded network cable The SUN2000 uses the RJ45 port. The SmartLogger uses a crimped COM port. HUAWEI TECHNOLOGIES CO., LTD. Page 30

Installation- Connect to inverter and EMI EMI at the end of the chain the RS485 address should be set as 1 Hig h ele ctri cit y pro du cti on Max.30 devices /com Max.80 devices in total Every inverter in the end of a chain should set Match resistance as Connect in the Comm.Param HUAWEI TECHNOLOGIES CO., LTD. Page 31

Function- LCD Main Menu Special User Common User Advanced User HUAWEI TECHNOLOGIES CO., LTD. Page 32

WebUI- Hardware prepare Operating system requirement of PC Operating system Windows High conversion efficiency Browser Internet Explorer 7.0/8.0/9.0 Firefox 17.0/18.0/19.0/20.0/21.0 Minimum resolution 1024 x 768 Default parameters: IP address: 192.168.0.10 Subnet mask: 255.255.255.0 Gateway: 192.168.0.1 IP of Smartlogger and PC should be in the same segment less than 100 m, CAT 5E e.g. Smartlogger : 192.168.0.10 PC : 192.168.0.11 HUAWEI TECHNOLOGIES CO., LTD. Page 33

Network Topology of PV Plant Monitoring Web/ Huawei Network Ecosystem (NetEco) Local area network (LAN) PC Server NetEco 3G Router SmartLogger Environment monitoring instrument(emi) RS485 PV Array AC Combiner Transformer Power grid HUAWEI TECHNOLOGIES CO., LTD. Page 34

Connect to Neteco server Make sure Smartlogger connected to server Server NetEco connects to the smartlogger as a client. e.g. SmartLogger and NetEco are in the same local area network (LAN) Client Set an IP address of the NetEco on the SmartLogger. e.g. Remote access scenarios, when the SmartLogger and NetEco are not in the same local area network Server+Client e.g. Smartlogger is connected to 3rd Party EMS HUAWEI TECHNOLOGIES CO., LTD. Page 35

Contents Overview of the Product Range Huawei Solar Inverter Technical Information Huawei Smartlogger Technical Information NetECO Portal Brief Overview HUAWEI TECHNOLOGIES CO., LTD. Page 36

Neteco Web- Login through Browser Open browser (IE 8/IE9 /Firefox) Input IP address 213.61.189.189:8010 ( Sever IP in Nurnberg ) Input User name & Password HUAWEI TECHNOLOGIES CO., LTD. Page 37

Neteco Web- Interface Main menu Device navigation tree Operation status HUAWEI TECHNOLOGIES CO., LTD. Page 38

Neteco Web- Monitoring HUAWEI TECHNOLOGIES CO., LTD. Page 39

Neteco Web- Querying Alarm log HUAWEI TECHNOLOGIES CO., LTD. Page 40

Neteco- Report Email HUAWEI TECHNOLOGIES CO., LTD. Page 41

Neteco APP- Installation Search Neteco in app shops ios (>5.0) Android (>4.0) HUAWEI TECHNOLOGIES CO., LTD. Page 42

SUN2000- App HUAWEI TECHNOLOGIES CO., LTD. Page 43

APP- PV plant in your hand HUAWEI TECHNOLOGIES CO., LTD. Page 44

New Products: Huawei SUN2000 36KTL LV 400V Huawei SUN2000 42KTL MV 480V M25 M63 M40 HUAWEI TECHNOLOGIES CO., LTD. Page 45

Thank you. www.huawei.com Copyright 2012 Huawei Technologies Co., Ltd. All Rights Reserved. The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. HUAWEI TECHNOLOGIES CO., LTD.