SAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE

Similar documents
CSE-M14T Mobile Rack USER'S GUIDE

Storage Backplane Specifications

SCA 813S Backplane USER'S GUIDE

SIDEBAND#2 3 JP43 JP37 JP45 JP38 JP41 J10 I C#2 JP36 JP50:I2CRST#1 JP38:I2CRST#2 OFF:SGPIO ON:I2C JP50 JP29 2 I C#1 JP40 JP44 JP51 JP29:9072 RESET

SAS 846 TQ BACKPLANE

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide

742S 742i SC742 CHASSIS USER'S GUIDE

80H A0 80H A0 80H A0

CHENBRO. User s Manual port 6Gb/s SAS Expander Backplane 80H A0. Version A0

CHENBRO. 4-Port SAS / SATA-II Backplane 80H User s Manual. Version 1.1~1.3. July / 18 / 2008

DNS-2608 Enterprise JBOD Enclosure User Manual

SAS-510T BACKPLANE USER'S GUIDE

SAS-833TQ BACKPLANE USER'S GUIDE

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H User s Manual. Version A0. July / 28 / 2008

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H C0. User s Manual. September / 10 / 2009

SAS-216EL1/EL2 BACKPLANE USER'S GUIDE

BPN-SAS-F424-A6 Backplane USER'S GUIDE

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

MegaRAID SAS e RAID Controller

1.0 S UPER SAS815TQ #0 ACT IN REV 1.00 #2 JP29:9071 RST JP18 JP18:BUZZER RESET JP46 JTAG UPGRADE JP29 SIDEBAND +5V +5V +12V +5V +12V JP42 JP33 JP34

RocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. Quick Installation Guide v1.0

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

SAS-933EL SERIES BACKPLANE USER'S GUIDE

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide

User Manual HPC U Tower/Rackmount Chassis for EATX Serverboard with 8 Hot-swap Hard Drive Cages

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

SAS-809T/TQ BACKPLANE

JP45 JP45:OH#2 TEMP. OPEN:45 C 1-2:50 C 2-3:55 C C203 C197 U63 JP35:9072#1 RESET 1-2: RESET 2-3: NO RESET C173 C243 R423 R270 JP97 JP98 JP99 JP100

Veritas Appliance Hardware Service Procedure

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

BPN-SAS3-743A Backplane USER'S GUIDE

Computer Assembly (Installing Mother Board & CPU)

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

SAS826A + C44 JP25 REV 1.00 R63 C1 C A U41 JP25:OH#1 TEMP C SAS IN #2 OPEN:45 C 1-2:50 JSM2 RT2 R200 R201 C D36 JP18 C138 BUZZER RESET JP45:OH#2 TEMP

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Dell SC5020 and SC5020F Storage System Owner s Manual

CHENBRO. 80H A0 Rev A0 User s Manual 01 / 03 / 2011

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

1U Device Expansion Unit Configuration Guide

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

SAS-113TQ BACKPLANE USER'S GUIDE

BPN-SAS-939H Backplane USER'S GUIDE

BPN-SAS3-825TQ BAckPlANe USeR'S GUIDe 1.0a

BPN-SAS3-216A-N4 Backplane

Manual. esata PCI Card 1+1. english.

EVGA assumes you have purchased all necessary parts needed to allow for proper system functionality.

JP39: OPEN:DEFAULT CLOSE:PS_ON JP36: OPEN:DEFAULT CLOSE:ANY POWER BUTTON JP38: OPEN:DEFAULT A C JPW1 MB-D JF4 R V 5V-SB C246 GND C86 C75 U30

Turbo PCI Express. PCI Express adapter for desktop PC. PCIe 4 to PCIe 4 data cable, 1.5 meter. Turbo ExpressCard. ExpressCard 34 adapter for laptop

BPN-SAS-825MTQ Backplane

3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

Dell SC7020 and SC7020F Storage Systems Owner s Manual

CHENBRO. SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 80H A0. Revision: 1.1. Dec / 3 / 2013

Open Vault Storage SAS Expander Firmware Specification V1.0

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Flexible 32-bit PCI to MiniPCI Express Adapter

BPN-SAS3-F418-B6N4 Backplane USER'S GUIDE

1. Introduction 1.1.Product Overview

SAS Expander Card User s Manual CHENBRO. SAS Expander Card User s Manual. April / 01 /

RocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. User s Guide v1.0

Dell SCv3000 and SCv3020 Storage System Owner s Manual

User s Guide. for Echo Express SE II Thunderbolt 2-to-PCI Express Card Expansion Chassis. For Windows

Intel RAID Expander Card RES3FV288 Hardware User's Guide. Intel Order Number: H

SAS JBOD Installation Reference Guide Revision 1.0

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

(SC822T/SC822S/SC822R)

13 MMC for PC Option Modules

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

CHENBRO CK port 6Gbit SAS Expander Card User s Manual. Version A0. September / 01 / 2010

Veritas Appliance Hardware Service Procedure

SC832/SC833 CHASSIS USER'S GUIDE

FAN2 JP56 32 A C BAR CODE 53 DEBUG JP55 FAN3 U81 F36 A 49 1 J25 X Y2 JF4 JPW1 TO PS JF3 JPI2C1 Q875 C201 Q873 Q876 F55 C197

A33606-AIC-02 User's Guide

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

SAS-213LTQ BACKPLANE USER'S GUIDE

CHENBRO. 6-Port 3Gb/s Mini-SAS Backplane 80H A0. User s Manual. August / 2010

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Quanta JB9 (M4600H) JBOD System Overview

AOC-USASLP-S8i AOC-USASLP-S8iR USER'S GUIDE

Taurus Super-S Combo

RocketRAID 3600 Series

RocketRAID 2700 Series

BPN-NVMe3-136NB-L Backplane BPN-NVMe3-136NB-R Backplane BPN-NVMe3-136PL Backplane BPN-NVMe3-136PL-J Backplane USER'S GUIDE

RocketRAID 2700 Series

In Win. Storage Chassis 10-Port 6Gb/s 2.5 Mini-SAS+SATA Backplane. User s Manual 2014/8/10

SCv3000 and SCv3020 Storage System. Owner s Manual

Transcription:

+ SAS933E REV 1.12 A BAR ODE SAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE Rev. 1.0

SAS-933E User s Guide Table of ontents Safety Information and Technical Specifications...1-3 1. Safety Guidelines... 1-3 2. Introduction to the SAS-933E2/E1... 1-4 A. Overview... 1-4 B. SAS-933E2/E1 Features... 1-4. SAS-933E2/E1 Storage apacity... 1-5 D. SM BPN-SAS-933E Specifications... 1-5 E. Advanced SAS/SATA Features... 1-5 3. The SAS-933E onnectors and Jumpers... 1-6 A. Front omponents... 1-6 A-1. Front onnector and Jumper Locations... 1-6 A-2. Front Panel omponents and onnectors... 1-6 A-3. Front Panel Jumpers... 1-6 A-4. Front onnector Pin Definitions... 1-7 A-5. Front Jumpers and LED Indicators... 1-8 B. Rear onnectors and LED Indicators... 1-10 B-1. Rear onnector/led Locations... 1-10 B-2. Rear LED Indicators... 1-10 User's Guide Revision: Rev. 1.0 Release Date: 08/31/2006 1-2

Safety Information and Technical Specifications Safety Information and Technical Specifications 1. Safety Guidelines or handling the components: To avoid personal injury and property damage, please carefully follow all the safety steps listed below when accessing your system ESD Safety Guidelines Electric Static Discharge (ESD) can damage electronic components. To prevent damage to your system, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ESD. Use a grounded wrist strap designed to prevent static discharge. Touch a grounded metal object before removing a component from the antistatic bag. Handle the RAID card by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts. When handling chips or modules, avoid touching their pins. Put the card and peripherals back into their antistatic bags when not in use. General Safety Guidelines Always disconnect power cables before installing or removing any components from the computer, including the SAS-933E Backplane. Disconnect the power cable before installing or removing any cable from the SAS-933E Backplane. Make sure that the SAS-933E Backplane is securely and properly installed to prevent damage to the system due to power shortage. An Important Note to the User All images and layouts shown in this user's guide are based upon the latest PB Revision available at the time of publishing of this User's Guide. The card you've received may or may not look exactly the same as the graphics shown in this manual. 1-3

SAS-933E User s Guide 2. Introduction to the SAS-933E2/E1 A. Overview The Supermicro SAS-933E2/E1 is a highly efficient, highly compatible and easy to use SES-2 Management System that offers the most advanced functionality provided by today's Serial Attached/SSI Protocol. apable of cascading up to 128 disk drives, the SAS-933E2/E1 supports fully-redundant Enterprise SAS (Serial Attached SSI) and high-capacity SATA disk drives that support up to 288 TB, using a 3-PI-E SAS HBA configuration, providing the user with the maximum data storage capability currently available on the market. Additionally, the SAS-933E2/E1 also supports up to 3Gbps of data transfer, offering superior data transferring efficiency. ombined with *SES-2 (SSI Enclosure Services-2) capabilities, the SAS-933E2/E1 provides complete Serial Attached Services and Serial Link Solutions to the market. B. SAS-933E2/E1 Features The SAS-933E2/E1 supports the following features: 1. 2. 3. 4. 5. 6. apable of cascading up to 128 disk drives with Supermicro's proprietary cable cascading configuration, Supports fully redundant Enterprise SAS and High apacity SATA Disk Drives (*for the SAS-933E2 with a dual-port expander), Supports Enterprise SAS and High apacity SATA Disk Drives (*for the SAS- 933E1 with a single-port expander), Supports the I 2 Interface to communicate with SAS/SATA Host Bus Adaptors (HBA), Minimizing the need for cables and connectors, uncluttering server space, and providing a trouble-free installation environment for the user, Supports the SES-2 (SSI Enclosure Services-2) protocol, providing the following features: RAID Rebuilt LED Indication Hot Spare LED Indication Thermal Monitoring and PWM (Pulse Width Modulation) Fan Speed ontrol Drive activity and drive failure indication for each drive slot Overheat/drive failure alarm via a buzzer installed on the backplane Overheat/drive failure LED Indicators built in Temperature Monitoring via a 2 wire (I 2 ) temperature sensor 1-4

Safety Information and Technical Specifications. SAS-933E2/E1 Storage apacity Using 1 PI-E SAS HBA: SATA 750GB x 128 Drives = 96 TB Using 2 PI-E SAS HBA: SATA 750GB x 256 Drives = 192 TB Using 3 PI-E SAS HBA: SATA 750GB x 384 Drives = 288 TB D. SM BPN-SAS-933E Specifications Supports 15 devices, Supports multiple data rates and auto-negotiation between SAS and SATA drives, Supports the Serial SSI Protocol (SSP), Serial ATA Tunneled Protocol (STP) and Serial Management Protocol (SMP), Supports the SFF-8485 protocol to communicate drive status to remote locations Meets the SAS standard with BROADAST (SES), BROADAST primitive for virtual resets with the capabilities of enabling, disabling and reporting manufacturing information; BREAK handling clarifications; and ALIGN transmissions from expanders and SATA port selectors, Provides a serial GPIO Interface that supports the SFF-8485 protocol Provides a low-latency connection router to create and maintain connections effectively, Provides configurable drive spin-up sequencing on a per-phy basis, Provides ESD protection, OS-Independent, easy to install and configure. E. Advanced SAS/SATA Features Supports 1.5 Gbps and 3 Gbps SAS data transfer per port, Supports dual-port SAS hard drives for redundancy, Supports serial, point-to-point, enterprise-level storage interface, Supports the SFF-8485 protocol to communicate the drive status to remote locations ompatible with SATA devices, With user-customized firmware and SSP initiator functions, provides drive management on SAS drives, Supports enclosure management through the SSP target with the SES protocol, Supports SATA II functions including staggered spin-up, hot plug, native command queuing and port selector, Allows flexible allocations of routing and concurrent connections to SAS/SATA targets. 1-5

SAS-933E User s Guide 3. The SAS-933E onnectors and Jumpers A. Front omponents A-1 Front onnector and Jumper Locations Front View 22 21 25 26 + 23 24 17 20 SAS933E REV 1.12 7 2 6 8 4 13 12 111 10 9 3 1 15 14 A-2. Front Panel omponents and onnectors 1. LSI SAS X28 ontroller (Primary hip) 2. LSI SAS X28 ontroller (Secondary hip) 3. Primary SAS onnector#1 4. Primary SAS onnector#2 5. Primary SAS onnector#3 6. Secondary SAS onnector#1* 7. Secondary SAS onnector#2* 8. Secondary SAS onnector#3* 9. 4-pin Power onnector#0* 10. 4-pin Power onnector#1* 11. 4-pin Power onnector#2* 12. 4-pin Power onnector#3* 13. Fan Header#1* 14. Fan Header#2* 15. Fan Header#3* 16. Fan Header#4* 17. Buzzer 18. Primary I2* 19. Primary IPMI* 20. Secondary I2* 21. Secondary IPMI* (*Refer to Page 1-6 for more information.) 1-6 A 5 27 19 18 28 BAR ODE 16

Safety Information and Technical Specifications A-3. Front Jumpers (*) 22. Buzzer Enable 23. Primary Mode_4 24. Primary Mode_5 25. Secondary Mode_4 26. Secondary Mode_5 27. Remote Fan-Failure LED Indicator Enable 28. External Fan-Failure Buzzer Enable (*Refer to Page 1-8 for the Front LED Indicators.) A-4. Front onnector Pin Definitions 1. Backplane Main Power onnectors (#9,#10,#11,#12) Pin Definitions You must use the 4-pin power connectors to provide adequate power to the Backplane. See the table on the right for pin definitions. 12V 4-pin Power onnector Pin Definitions Pins Definition 1 +12V 2 & 3 Ground 4 +5V 2. 3-pin Fan Headers (#13,#14,#15,#16) Pin Definitions There are four 3-pin fan headers located Fan Header on the front panel. To prevent overheat, Pin Definitions connect a 3-pin fan cable to each fan header. Default: Fan Enabled. See the table on the right for pin definitions. *Notes: 1. The fan headers use D power. 2. For external fan failure audio alerts, you will need to enable the Buzzer Jumper (marked #22) and External Fan-Failure Buzzer Jumper (marked#28) concurrently. (Refer to the jumper section.) Pin# Definition 1 Ground 2 +12V 3 Tachometer 3. Primary/Secondary I 2 (marked #18,#20) and IPMI (marked #19, #21) onnector Pin Definitions There are two pairs of I 2 and IPMI Monitoring onnectors on the SAS- 933E. These components monitor the status of the power supply, fan and temperature for their respective SAS channel. See the table on the right for pin definitions. Pin# I 2 /IPMI Pin Definitions Definition 1 Data 2 Ground 3 lock 4 No onnection 1-7

SAS-933E User s Guide A-5. Front Jumpers and LED Indicators 1. Buzzer Enable (marked#22) lose Pin 1 and Pin 2 of this jumper to enable the onboard buzzer (marked#17) to provide an audible alert when an overheat occurs. If the Fan-Failure Buzzer Jumper (marked #28) is also "enabled," this buzzer will also provide an audible alert in an event of a fan failure. See the table on the right for jumper settings. Buzzer Enable (#22) Description losed Buzzer Enabled (*Default) Open Buzzer Disabled (*Note: Please enable this jumper to receive overheat or fan-failure alerts, since the Overheat and Fan Failure LED indicators may not be visible from outside the chassis.) 2. External Fan-Failure Buzzer Enable (marked#28) In addition to enabling the Buzzer Jumper (#22) indicated above, you will need to close both Pin 1 and Pin 2 of this jumper (marked#28) to receive the audible alert in an event of a fan failure. See the table on the right for jumper settings. Buzzer Enable (#22) (*Note: If both Buzzer Jumper and Fan-FailureBuzzer Jumper are set to "Enabled", the buzzer will be activated in the event of overheat or fan failure. To determine if it is an overheat or a fan failure, you will need to refer to the Overheat LED and the Fan-Failure LED below. If the Overheat LED is on, it indicates a chip overheat. If the Fan-Failure LED is on, it indicates a fan failure. If both LEDs are on, both chip overheat and fan failure have occured.) Description losed Buzzer Enabled (*Default) Open Buzzer Disabled External Fan-Failure Buzzer Enable (#28) Description losed Buzzer Enabled (*Default) Open Buzzer Disabled Front LED Locations (See Page 1-9 for more details) Overheat Fan Failure 5V PWR 12V PWR (Red) (Green) (Blue) (Red) 2 1 + SAS933E 3 REV 1.12 A BAR ODE 1-8 4

Safety Information and Technical Specifications 3. Pri_Mode_4 (marked#23) and Pri_Mode_5 (marked#24): Primary SAS ontroller Enable lose Pin 2 and Pin 3 of Pri_Mode_4 (high) (marked#23) and Pin 2 and Pin 3 of Pri_Mode_5 (low) to enable the Primary SAS ontroller (marked 1). (*Note: Please do not change the manufacturer default setting.) Primary SAS ontroller Mode s (#23/#24) *Default Pin Mode Mode_4 1-2 High Mode_5 2-3 Low 4. Sec._Mode_4 (marked#25) and Sec._Mode_5 (marked#26): Secondary SAS ontroller Enable (marked#2) lose Pin 2 and Pin 3 of Pri_Mode_4 (high) (marked#25) and Pin 2 and Pin 3 of Pri_Mode_5 (low) to enable the Secondary SAS ontroller (marked#26). (*Note: Please do not change the manufacturer default setting.) Primary SAS ontroller Mode s (#25/#26) *Default Pin Mode Mode_4 1-2 High Mode_5 2-3 Low 5. Remote Fan-Failure LED Enable (marked #27) lose both pins of this jumper (marked#27) to enable a remote fan failure LED indicator. Please connect a cable to an external LED to provide a Fan-Failure LED Indication that is visible from outside the chassis. See the table on the right for details. Remote Fan Failure LED Enable (#27) losed Open Description Remote Fan Failure LED Enabled Remote Fan Failure LED Disabled 6. Front LED Indicators (Refer to Page 1-8 for LED Locations) #1. Overheat LED: Red (Solid On: chip overheat. In this case, the buzzer is activated if Buzzer Jumper is enabled.) #2. Fan Failure LED: Red (Solid On: fan failure. In this case, the buzzer is activated if both Buzzer Jumper ((#22)) and Fan-Failure Buzzer ((#28)) Jumper are enabled.) #3. 5V Power On: Blue (Solid On: The 5V Power is on. Please unplug all power cables before removing, installing or changing components.) #4. 12V Power On: Green (Solid On: The 12V Power is on. Please unplug all power cables before removing, installing or changing components.) 1-9

SAS-933E User s Guide B. Rear onnectors and LED Indicators B-1 Rear onnector/led Locations Rear View SAS#0 SAS#1 SAS#2 SAS#3 SAS#4 1 2 3 4 5 6 7 8 9 SAS#5 SAS#6 SAS#7 SAS#8 SAS#9 SAS#10 SAS#11 SAS#12 SAS#13 SAS#14 21 22 23 24 25 26 27 28 29 30 111 13 18 19 20 14 16 17 10 12 15 SAS onnectors (#0-14): (*See above) B-2 Rear LED Indicators (*See the tables below for details.) A. Drive Activity LED Indicators SAS onnector Activity LED #16 SAS#0 Active #17 SAS#1 Active #18 SAS#2 Active #19 SAS#3 Active #20 SAS#4 Active #21 SAS#5 Active #22 SAS#6 Active #23 SAS#7 Active #24 SAS#8 Active #25 SAS#9 Active #26 SAS#10 Active #27 SAS#11 Active #28 SAS#12 Active #29 SAS#13 Active #30 SAS#14 Active B. Drive Failure LED Indicators SAS onnector Failure LED #1 SAS#0 failed #2 SAS#1 failed #3 SAS#2 failed #4 SAS#3 failed #5 SAS#4 failed #6 SAS#5 failed #7 SAS#6 failed #8 SAS#7 failed #9 SAS#8 failed #10 SAS#9 failed #11 SAS#10 failed #12 SAS#11 failed #13 SAS#12 failed #14 SAS#13 failed #15 SAS#14 failed 1-10