M-series Foundation Fieldbus I/O

Similar documents
Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

S-series Foundation Fieldbus I/O

S-series H1 I/O Card with Integrated Power

M-series Profibus DP Series 2 Plus Interface Card

M-series Serial Interface Series 2

M-series Intrinsically Safe I/O

DeltaV M-series I/O Subsystem Horizontal Carriers

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

S-series DeviceNet Interface Card

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

M-series Profibus DP Series 2 Plus Interface Card

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

DeltaV VerticalPlus I/O Subsystem Carriers

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

S-series Serial Interface

S-series Horizontal Carriers

S-series Sequence of Events Card

M-series MQ Controller

M-series MX Controller

M-series Serial Interface Series 2

S-Series DeltaV Controller Interface for PROVOX I/O

S-series Profibus DP Interface Card

S-series Mass Connection Solutions

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

M-series Traditional I/O

DeltaV SIS Conditioning Components

DeltaV SD Plus Controller

M-series DC to DC Power Supply

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

M-series Virtual I/O Module 2

S-series Serial Interface

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

M-series MQ Controller

S-series Virtual I/O Module 2

DeltaV Electronic Marshalling for Migrations

M-series Virtual I/O Module 2

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

M-series DeltaV Controller Interface for RS3 I/O

DeltaV M-series Traditional I/O

M-series I/O Subsystem Horizontal Carriers

S-series Virtual I/O Module 2

Fast Control Response Requirement

S-series DeviceNet Interface Card

DeltaV M-series Traditional I/O

DeltaV Ethernet I/O Card

S-series Horizontal Carriers

M-series DeltaV Controller Interface for PROVOX I/O

DeltaV M-series Traditional I/O

OPC Mirror Redundancy

OPC Data Access Server Redundancy

S-series Sequence of Events Card

Configuration Software Suite

DeltaV Wireless I/O Card

S-series Ethernet I/O Card

DeltaV Virtual IO Module Network Gateway

DeltaV S-series Traditional I/O

Configuration Software Suite

S-series Electronic Marshalling for Migrations

Professional Station Software Suite

Professional Station Software Suite

Wireless Field Data Backhaul

Operator Station Software Suite

DeltaV SIS TMConditioning Components

DeltaV Remote Client. Introduction. Remote engineering and operator consoles. View Multiple DeltaV Systems from a single workstation

DeltaV Virtual Machine Controller Simulation

DeltaV Discovery for Life Science Research Laboratory Applications

ProfessionalPLUS Station Software Suite

DeltaV SIS with Electronic Marshalling - Virtual Simulation

DeltaV Control Network Hardware

A redundant DeltaV M-seriess controller protects your critical process from unexpected

Smart Commissioning. White Paper February 2018

DeltaV Remote Client. Introduction. Remote engineering and operator consoles. View Multiple DeltaV Systems from a single workstation

Operator Station Software Suite

Use of Cisco Switches on the DeltaV Area Control Network (ACN)

DeltaV Simulate. Introduction. Product Data Sheet April DeltaV Distributed Control System

DeltaV Connect Solution for Bailey Systems

OPC Mirror. Introduction. OPC Server. Bi-directional data flow. Easy configuration. Fast data transfer. OPC Data Access compliant.

Smart Commissioning. White Paper January 2019

How Emerson s I/O on Demand Is Changing the Automation Infrastructure

DeltaV Connect Solution for Siemens TELEPERM M Systems

Batch Analytics. Predicts end-of-batch quality. Detects process faults and provides reason for deviation so operations can take action in real time

DeltaV OPC UA Servers and Clients

DeltaV Connect Solution for Moore Systems

Valve and Case Expansion Monitor Specifications

DeltaV IS Electronic Marshalling

Ovation Controller Model OCR1100

DeltaV OPC UA Servers and Clients

Operator Station Software Suite

Parallel Redundant Protocol (PRP)

Distributed Intrinsically Safe Fieldbus Applications

S-series IS Electronic Marshalling

DeltaV OPC.NET Server

S-series Electronic Marshalling

Ovation Compact Controller

Online Interfaces and Optional Features

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Faster module execution

ControlWave PAC Redundant Systems

Transcription:

DeltaV Distributed Control System Product Data Sheet M-series Foundation Fieldbus I/O Use DeltaV state-of-the-art FOUNDATION Fieldbus redundant I/O for your process control system. Increases input/output Takes advantage of all smart device capabilities Facilitates multi-drop 16 devices on one port Features secure uninterrupted control Provides third-party device support 1:1 redundancy for M-series Foundation fieldbus I/O Autosense of redundant I/O Automatic switchover Provides synchronized control Introduction Are you looking for an efficient, yet robust, I/O subsystem? M-series Foundation fieldbus I/O is a modular subsystem that communicates digitally with field devices, increases your input/ output capacity, and gives you access to more information about your process than conventional I/O subsystems. If you want an efficient, economical, and secure process control system, use DeltaV M-series Foundation fieldbus redundant I/O. It greatly enhances device diagnostics that affect your control strategy and alerts operators to device malfunctions. The modular design of M-series Foundation fieldbus I/O offers flexibility during installation. It s designed to be installed in the field, close to your devices. M-series Foundation fieldbus I/O is equipped with function and field-wiring protection keys to ensure that the correct I/O card is always plugged into the corresponding terminal block. Modularity, protection keys, and increased input/output capacity make M-series Foundation fieldbus I/O a smart choice for your process control system.

Benefits Increases input/output. Use M-series Foundation fieldbus I/O instead of Classic I/O to increase information flow. Take advantage of Foundation fieldbus digital communications to access additional information from your smart devices. Get more information over one wire than over multiple wires, as with Classic I/O. Takes advantage of all smart device capabilities. Increase your ability to communicate with your devices using DeltaV M-series Foundation fieldbus I/O; field device status is updated continuously. For multi-variable devices, all process variables are available on the single fieldbus connection. Facilitates multi-drop 16 devices on one port. Save on wiring expenditures by installing M-series Foundation fieldbus I/O in the field, close to the actual field devices. Mounting the controller with the I/O further reduces your wiring costs by eliminating the need for long runs of multi-cores. Multi-dropping up to 16 devices on one port reduces your wiring expenses substantially. The integrated design of the M-series Foundation fieldbus I/O can eliminate the need for marshaling panels. This saves you even more time and money. Features secure uninterrupted control. A DeltaV system offers back-up link active schedule (LAS) to ensure secure control when upgrading a card or in the case of card failure. LAS control is automatically transferred to the backup device when upgrading or experiencing card failure. Control is automatically transferred back to the H1 Interface Card when the system detects a new card. This process requires no user interaction. Provides third-party device support. The DeltaV system provides third-party device support for devices that have successfully passed rigorous testing by Emerson Process Management. This testing ensures reliability and safety and allows you to benefit from the open fieldbus architecture when selecting field devices. 1:1 Redundancy for M-series Foundation fieldbus I/O cards. You can easily add redundancy to an existing system. DeltaV redundant M-series Foundation fieldbus I/O uses the same Series 2 I/O cards as non-redundant I/O. This allows you to leverage your investment in installed I/O and in I/O spares. No additional configuration is required. Automatic Switchover. Should a primary I/O card fail, the system automatically switches to the standby card without user intervention. The operator is given clear notification of a switchover at the operator display. Provides synchronized control. The DeltaV system provides the ability to assign DeltaV function blocks to run in the DeltaV M-series Foundation fieldbus I/O card. DeltaV function blocks that run in the DeltaV M-series Foundation fieldbus I/O card are included in the fieldbus macrocycle, and their execution is fully synchronized with function blocks running in fieldbus devices on the segment, thus minimizing scheduling delays that commonly occur in control loops in which the control spans the controller and field devices. Increase your process control system s level of sophistication using M-series Foundation fieldbus I/O. You are already aware of the increased input/output capabilities and improved communication with your smart devices. Now go one step further and use AMS Device Manager with your M-series Foundation fieldbus I/O from the control room or maintenance shop. Using AMS Device Manager, you can access all the necessary information to configure, commission, monitor, and troubleshoot all your Foundation fieldbus smart devices. Using AMS Device Manager you can also access status and diagnostic data from smart devices and monitor their performance. Increase product quality and minimize unplanned downtime with this dynamic application. Improve the productivity and profitability of your process control system. Fieldbus devices not manufactured by Emerson Process Management divisions are categorized as third-party devices. The DeltaV system provides third-party device support for devices that have successfully passed rigorous testing by Emerson Process Management and are registered by the Fieldbus Foundation. This allows you to benefit from the open fieldbus architecture when selecting field devices. Listed Fieldbus Devices on the DeltaV System: For current fieldbus information, including device downloads and a list of third-party devices that have been tested for interoperability with the DeltaV system, please refer to www.easydeltav.com and click on Key Technologies/Fieldbus. Autosense of redundancy. DeltaV autosenses redundant I/O which greatly simplifies the task of adding redundancy to the system. The redundant pair of cards are treated as one card in the system tools. www.emerson.com/deltav 2

Product Description The I/O card is enclosed in a DeltaV-designed common form factor that plugs into the I/O interface carrier. The housing is clearly labeled with the enclosed I/O card type. Clearly visible LEDs on the top of the I/O card display the power, error, and status to the two channels included in the I/O card. The Fieldbus I/O Card meets ISA G3 corrosion specifications by using superior electronic components and conformal coating. Redundancy Made Easy. The active and standby I/O cards are connected to the field at the redundant terminal block. When a fault is detected, the system automatically switches to the backup I/O card. The reliability rating of the terminal block is greater than the high reliability of the I/O cards. The controller scans each card of a redundant pair. Incremental controller loading is a function of the number of redundant cards. In addition, the redundant cards have dedicated communication between the pair and the backup card monitors the health of the active card. Configuration of redundancy is not required as the DeltaV system automatically recognizes the redundant pair of cards and assigns a device signal tag (DST) to the channels on the primary card. An alarm on the integrity error for the primary notifies the operator of a switchover. The backup card is also monitored for integrity alarms. Events that can cause a switchover include. y Hardware failure within the active card. y Communications failure between the active card and the controller. y Removal of the active card from the carrier. y Detection of a fault in the field wiring. A switchover may also be initiated from the diagnostics explorer, and the health and status of both cards and theirchannels are available in the diagnostics explorer. The system automatically commissions a new standby card. In safe areas, failed cards can be replaced under power. In hazardous areas, appropriate installation procedures must be followed. The M-series FOUNDATION fieldbus I/O subsystem includes: y H1 interface card and simplex terminal block, or y 2 H1 interface cards and redundant terminal block Signals referenced for each connected Foundation Fieldbus device will count at most 1 DST. The DST type counted will be the most valuable type used to reference a signal for each device. For example, a device with 1 AI signal reference and 1 AO signal reference will count as 1 AO DST. Switchover time for redundant I/O is minimal, and the process will be undisturbed. Foundation Fieldbus redundant I/O. www.emerson.com/deltav 3

Hardware Specifications Environmental Specifications Operating temperature* Storage temperature Relative humidity -40 to 70 C (-40 to 158 F) -40 to 85 C (-40 to 185 F) 5 to 95%, non-condensing Protection rating IP 20 Airborne contaminants Shock ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating 10 g ½-sine wave for 11 ms Vibration 1 mm peak-to-peak from 5 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz *Operating any electronics at the higher end of its temperature range for long periods of time will shorten its expected lifetime, see Effects of Heat and Airflow Inside an Enclosure White Paper for more information. Specifications for H1 card, 2 channels, Foundation Fieldbus Number of channels (ports) 2 Number of field devices: 16 per port (dependent on device power consumption an IS requirement) Number of Ff function blocks Isolation 96 per card (64 fieldbus and 32 standard DeltaV) Each channel is isolated from the system and from each other and factory tested to 1500 VDC Nominal signal range (span) Fieldbus FOUNDATION IEC 61158-2 Localbus current per card (12 VDC nominal) Field circuit power per card Standards 200 ma typical, 300 ma maximum 9 TO 32 VDC, 12 ma per channel IEC 1158 data link layer Airborne contaminants Hazardous area/location* 1) I/O interfaces 2) Field circuits ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating CENELEC Zone 2 IIC T4 hazardous area or Class, I Div 2, Groups A, B. C. D T4 hazardous locations *Refer to Zone 2 installation instructions (12P2046) and/or Class 1 Division 2 installation instructions (12P1293) for information on installing in hazardous areas. www.emerson.com/deltav 4

Ordering Information Description M-series H1 I/O Interface Card and Terminal Block (includes 1 Interface Card and a simplex Terminal Block) Redundant M-series H1 I/O Interface Card and Terminal Block (includes 2 Interface Cards and a redundant Terminal Block) Prerequisites A fieldbus power supply is required for each bus segment. Model Number VE4017P0 VE4037P0 Each fieldbus segment must be terminated at both ends. A fieldbus brick and terminator for each segment are recommended. Emerson North America, Latin America: +1 800 833 8314 or +1 512 832 3774 Asia Pacific: +65 6777 8211 Europe, Middle East: +41 41 768 6111 www.emerson.com/deltav 2017, Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.