OPM-50 Optical Power Meter User s Manual

Similar documents
OLT-55. Intelligent Optical Loss Tester. User s Manual

PPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

USER MANUAL FOT-PM Optical Power Meter

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide

PM-204A/B. Power Meter. Operation Guide

HCC-CW-201A. CWDM Analyzer. Operation Guide

PM-100 SERIES. Operation Guide. Power Meter V

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual

EOS-6000 Series Optical A/B Switch User Manual DC Version

Operation Manual for OPM-1315 Optical Power Meter

AE3100 Series User Manual. Version 1.02

OFS 300 Optical Fiber Scope User s Guide

Operation Manual for OLS-1315 Optical Light Source

6400 CWDM Series. Fiberlink. 4 or 8 Channel Coarse Wave Division Multiplexers for Single Mode Fiber. User s Manual

HX1 Bluetooth Stereo Headset

Optical Power Meter MT-7603

palmotdr User s Manual

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

FTE-6000 Hand Held Tuneable Laser Source

Model M140 Mini Solar Power Meter

RA3301Optical Multimeter

Model RP450. Optical Power Meter

PON Optical power meter USER'S GUIDE

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

FiberLink 6650 Series

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

RA3211 PON optical power meter

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

HDMI Extender over Fiber

MT-7610 Optical Time Domain Reflectometer USER'S GUIDE

Optical Time Domain Reflectometer USER'S GUIDE

AF-OLK5A Series Fiber Optic Test kit

User Manual IDS-3106 Series. 6.5" Industrial Open Frame Monitor

MX3 BT LED Party Tube

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL

Rev. F January 13, 1999 Part Number: OFL Operations Manual for the OFL 100 Mini-OTDR

User Manual IDS-3206 Series. 6.5" Industrial Panel Mount Monitor

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

GVIS Video Inspection Scope

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

OFSR-X. Users Manual. OptiFiber Smart Remote Options

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

OTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product

VIS Video Inspection Scope

5100 Series. Fiberlink. 10/100/1000 Base-T Etheret over one or two single mode or multimode fibers. User s Manual

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DIGITAL DIRECTIONAL INLINE OPTICAL POWER MONITOR/METER

User Manual. pe-100 fiber. DOC-014 Iss 3 1

Prestigio P371 Users manual

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

LTS-2A LTS-10 LTS-10C LTS-11 LTS-12

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

Laser Diode Controller Instruction Manual

DVI Extender over single LC Fiber with TMDS video and EDID data.

Operating Instructions

Light-Source Mainframe

IAQ-CALC TM Indoor Air Quality Meter

Installation Guide for Fiber Tap HD8

Continuous Wave Single Frequency Lasers. Concerto Series. 442nm 25, 50, 75 & 100mW

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

Toll Free: Tel: Fax:

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

OLS-55/56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

Optical CWDM Power Meter

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Heavy Duty Psychrometer + IR Thermometer Model HD500

OLP-55 Sm a r t Optical Power Meter A Sm a r t, Future-Proof Optical Power Meter

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

BTS300S-BLK. DuraVibePro. Bluetooth Speaker USER MANUAL

User's Guide. Model Laser Photo Tachometer

VIAVI SmartClass OLA-55M

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

9040/9040UK. Users Manual. Phase Rotation Indicator

Handheld Laser Particle Counter. Model: P311. Operation Manual. Ver: 1.50 AIRY TECHNOLOGY INC

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

LegacyPlus 7-OR SERIES RETURN TRANSMITTER INSTRUCTION MANUAL 7-OR-RT/xxx

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Table of Contents List of Equipment General Information Safety Precautions Device Installation...

Multimode Laser-532 Installation and Operation Manual

AOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE

MODEL C-HOMWA-1 CONNECTIVITY KIT, CONNEX (USB)

TOM103. Optical Power Meter OPTICAL POWER METER

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

JDSU Optical Handheld Testers. Family of light sources, power meters, attenuators, loss test sets, return loss meters, and optical talksets

iconverter 2-Module Power Chassis

FlexPOD. Fiberlink. Flexible Passive Optical Distributor. User s Manual. Artel Video Systems Fiberlink FlexPOD. Fiberlink FlexPOD is a

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

SATA II HDD Canister KISS DA 435 Quick Reference Guide

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

4800 Series FIBER OPTIC DVI EXTENSION SYSTEM

Global Water Instrumentation, Inc.

87421/22A Power Supply. Operating and Service Manual

4 Port USB Power Hub. Model: JH-800 USER MANUAL

Transcription:

OPM-50 Optical Power Meter User s Manual Shineway Technologies, Inc. All rights reserved.

0BSafety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personnel injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met. The CAUTION sign denotes a hazard. It calls attention to an operating procedure, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or the entire product. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met. The NOTE sign information that may be beneficial during the use and maintenance of the instrument. Users should avoid looking directly into optic output of any working laser source or live fiber. And the use of microscope or magnifier should also be avoided, for the use of such devices can focus a highly intense beam onto the retina, which may result in permanent eye damage Battery: OPM-50 battery type is lithium battery. Do not take battery out without technical staff s assistance. Do not expose battery to fire or intense heat. Do not open or mutilate battery. Avoid touching the electrolyte in the battery, which is corrosive and may cause injuries to eyes, skin or damage to clothes. External Power Supply: Power Adaptor, 5V DC/750mA Laser Radiation: To avoid serious eye injury, never look directly into the optical outputs of fiber optic network equipment, test equipment, patch cords, or test jumpers. Always avoid looking directly into the optical output port, Shineway Technologies, Inc. - 1 -

when the instrument is working Always replace protective dust cap on the detector port when the instrument is not in use. Always avoid looking directly at unconnected end of optic fiber in testing and make the unconnected end pointing at a non-reflective object. Shineway Technologies, Inc. - 2 -

Contents TUSAFETY INSTRUCTIONSUT... 1 TU1. GENERAL INFORMATIONUT... 4 TU1.1 SCOPE OF THIS MANUALUT... 4 TU1.2 UNPACKING AND INSPECTIONUT... 4 TU1.3 INTRODUCTIONUT... 4 TU2. BASIC OPERATIONUT... 5 TU2.1 FOREWORDUT... 5 TU2.2 INSTRUMENT DETAILSUT... 6 TU2.2.1 External InterfacesUT... 6 TU2.2.2 Keypad OperationUT... 7 TU2.2.3 IndicatorUT... 8 TU2.3 USE OF BATTERYUT... 8 TU2.4 CONNECTOR CLEANINGUT... 8 TU3. OPERATIONUT... 9 TU3.1 POWER ONUT... 9 TU3.2 CONTRASTUT... 9 TU3.3 ZEROUT... 10 TU3.4 REFERENCEUT... 11 TU3.5 SAVE RECORDUT... 12 TU3.6 REVIEW RECORDUT... 13 TU3.7 DELETE RECORDUT... 13 TU3.8 SET TIMEUT... 14 TU3.9 LOAD DEFAULTUT... 14 TU3.10 LANGUAGE SETTINGUT... 15 TU3.11 AUTO OFFUT... 15 TU4. CALIBRATIONUT... 16 TU4.1 OPTICAL INTERFACE CLEANINGUT... 16 TU4.2 CALIBRATION REQUIREMENTSUT... 16 TU5. SPECIFICATIONSUT... 17 TU6. WARRANTY INFORMATIONUT... 18 TU6.1 WARRANTY PERIODUT... 18 TU6.2 EXCLUSIONUT... 18 TU6.3 WARRANTY REGISTRATIONUT... 18 TU6.4 RETURNING INSTRUMENTUT... 18 TU6.5 CONTACT CUSTOMER SERVICEUT... 19 Shineway Technologies, Inc. - 3 -

1B1. General Information 7B1.1 Scope of this Manual Thank you for purchasing ShinewayTechP P instrument. Please read this manual carefully before using ShinewayTechP P fiber optic instrument. Always be aware of the Warning and Caution sign appearing throughout this manual. This manual contains the information necessary for proper operation and maintenance of ShinewayTechP P instrument, troubleshooting instructions as well as information regarding maintenance services. All ShinewayTechP P instruments are carefully assembled and undergo rigorous mechanical, electrical, and optical inspection prior to shipment. Beside the instrument, the package also includes a lithium battery pack, a charging/data transfer cable, a power adapter, a FC/PC flange and this user's manual. For detailed information, please refer to the packing list. Upon receiving the instrument, please check for any obvious signs of physical damage that may have occurred during shipment. Report any damage to the shipping agent or the representative of Shineway Technologies Inc. immediately. Retain the original packing materials in case reshipment is necessary. 8B1.2 Unpacking and Inspection This instrument has been carefully packed in accordance with standard shipping procedures. Examine the instrument for damage that may have occurred during shipment. If you find any damage or the instrument is not working, or if any of the following items are not included, please contact your representative of Shineway Technologies, Inc. If necessary, you may contact Shineway Technologies, Inc via this email: support@shinewaytech.com. 9B1.3 Introduction ShinewayTechP P OPM-50 paired with SLS-50 Intelligent Stabilized Laser Source can be used to identify fiber, measure attenuation and loss, verify continuity and evaluate fiber link transmission quality. Features: Shineway Technologies, Inc. - 4 -

Automatic wavelength identification Automatic loss measurement Remote reference value setting FTTx applicable Internal clock & fiber S/N editable Memory of 1000 test records Data Transfer to PC via USB USB power charging No warm-up, quick start Backlight 125 hours continuous operation Pocketsize, lightweight and easy-to-use CE FCC certificates Automatic Wavelength Identification Compatible with the digital encryption protocols of SLS-50, OPM-50 can automatically identify the wavelength of the optical signals transmitted from SLS-50 and switch to the corresponding test mode, which greatly reduces the workload at both ends and risk of potential error. Remote Reference Value Setting OPM-50 can receive the power parameters of digital-encrypted signal transmitted from SLS-50 as reference for precise link loss measurement even the two units are far apart. Internal Clock & Fiber S/N Editable Internal clock enables OPM-50 to save test data with time and editable fiber SN information. Compatible with FTTx Test OPM-50 can be applied to measure Triple-play signals (1310nm, 1490nm and 1550nm) on Passive Optical Network (PON). 2B2. Basic Operation 01B2.1 Foreword This part introduces the basic operation on OPM-50. Specific operations of each type instrument are elaborated in Chapter 3 of this manual. Please read this manual carefully for optimal operation. If you encounter any problems during operation, you are welcome to Shineway Technologies, Inc. - 5 -

contact the technical staff of our company or representatives. 1B2.2 Instrument Details 1 2 23B2.2.1 External Interfaces 1. Optical Input OPM-50 is available with FC connector (Interchangeable SC/ST). 2. USB Power /Data Port OPM-50 can be charged by external power adapter (5V DC, 750mA). Shineway Technologies, Inc. - 6 -

3B2.2.2 Keypad Operation Power on/off Toggle between calibrated wavelengths Toggle between mw(μw/nw/pw), db and ; Adjust reference value in [Reference] interface; Adjust Cab & Fib value in [Store] interface; Look up test records in [Recall] interface; Adjust date and time in [Set Time] interface; Adjust contrast in [Contrast] interface. Set current measured value as reference value in [Reference] interface; Adjust reference value in [Reference] interface; Adjust Cab & Fib value in [Store] interface; Look up test records in [Recall] interface; Adjust date and time in [Set Time] interface; Adjust contrast in [Contrast] interface. Toggle between functional interfaces Shift digit positions or functions in [Reference], [Store], [Set Time] or [Delete] interface Enter functional interface; Confirm Turn backlight on/off Shineway Technologies, Inc. - 7 -

43B2.2.3 Indicator Charging indicator 21B2.3 Use of Battery OPM-50 works on lithium battery, please make sure battery is mounted properly before use. When battery is low, low battery indicator will appear on LCD. You can still use OPM-50 as long as its display on LCD is identifiable. Please charge as soon as possible when battery is low to ensure accurate measurement. Please take out the battery if OPM-50 is not in use for a long time. 31B2.4 Connector Cleaning Please follow the instructions below when cleaning: Turn off the instrument before cleaning. Non-compliant operation may result in hazardous radiation exposure. Turn off laser source before cleaning optical interface. Always avoid looking directly into the optical output port when the instrument is working, laser is invisible and can cause serious eye damage. Disconnect instrument from power supply before cleaning to prevent electric shock. Do not install unauthorized parts or make unauthorized adjustments on instrument. Please consult qualified professional about maintenance and repair services. Always clean optical connector before using optical power meter to ensure accurate measurement. Clean the optical connector gently with cleaning swab. Inappropriate maintenance may result in low performance or error: Distance error increases; Linearity error; Extra optical power attenuation; Received optical power is beyond normal range. Shineway Technologies, Inc. - 8 -

3B3. Operation 41B3.1 Power On Press [On/Off] button and loading screen appears, see Figure 3.1. ShinewayTech OPM-50 Figure 3.1 Then it enters functional interface (The last interface before last shutdown), see Figure 3.2. -15.34 Contrast Figure 3.2 Press and button to toggle between below functional interfaces: Contrast Zero Reference Store Recall Auto Off Lang/ 语言 Load Default Set Time Delete Press button to enter selected functional interface. Please see below the detailed information of each interface. 51B3.2 Contrast Press and button to [Contrast] interface, see Figure 3.3. Shineway Technologies, Inc. - 9 -

-15.34 Contrast Figure 3.3 Press button to enter the interface. Press and button to adjust contrast and press button to confirm. 61B3.3 Zero Press and button to [Zero] interface, see Figure 3.4. - - - - - - Low Zero Figure 3.4 Press button to start zeroing. If zeroing is successful, below screen will appear, please see Figure 3.5. SUCC Low Zero Figure 3.5 If zeroing fails, below screen will appear, see Figure 3.6. Shineway Technologies, Inc. - 10 -

ERR Low Attention: Zero Figure 3.6 1. Zeroing is used when measuring low power, e.g. lower than -35 to ensure accuracy; 2. Put dust cap on connector when perform zeroing; 3. If ERR appears, zeroing fails. Please check the connection between dust cap and connector and redo zeroing. 4. If zeroing still fails, please contact your regional contact or ShinewayTech. 71B3.4 Reference Press and button to [Reference] interface, see Figure 3.7. Ref :- 9.94-15.34 Reference Figure 3.7 In this interface, if the laser source (ShinewayTech laser source with AutoID function) on the other side of the tested fiber enables AutoID, then the optical power meter will automatically identify the incoming signal wavelength and set the reference value sent from the laser source as reference ( AutoID will appear in this interface) to enhance the testing efficiency and avoid potential operation fault. If the laser source does not enable AutoID function, user can press button to set currently measured power value as reference value or manually adjust the reference value. If you need manually adjust reference value, press interface, see Figure 3.8. button to enter reference setting Shineway Technologies, Inc. - 11 -

Ref :- 9.94-15.34 Reference Figure 3.8 Press button to shift the digit position to be adjusted; press and button to adjust the value and press button to confirm. 81B3.5 Save Record Press and button to [Store] interface, see Figure 3.9. Cab001 Fib011-15.34 Store Figure 3.9 Press button to record setting interface, see Figure 3.10. Cab001 Fib011-15.34 Store Figure 3.10 Press button to shift the digit position of Cab and Fib value to be adjusted; press and button to adjust the reference value and press button to save the record. Shineway Technologies, Inc. - 12 -

91B3.6 Review Record Press and button to [Recall] interface, see Figure 3.11. Cable : 001 Fiber : 011 Wave : Ref : -9.94 Power: -15.34 Data : 2008-10-09 Time : 09:24:35 Recall Figure 3.11 Press and button to review saved record. 02B3.7 Delete Record Press and button to [Delete] interface, see Figure 3.12. - - - - - - Low Delete Figure 3.12 Press button to delete record, see Figure 3.13. Are you sure? Yes No Delete Figure 3.13 Press button to toggle between Yes or No, press button to confirm. Shineway Technologies, Inc. - 13 -

12B3.8 Set Time Press and button to [Set Time] interface, see Figure 3.14. Data : 2008-10-09 Time: 09:24:35 Set Time Figure 3.14 Press button to enter [Set Time] interface, see Figure 3.15. Data : Time: 2008-10-09 09:24:35 Set Time Figure 3.15 Press button to shift the digit position to be adjusted; Press and button to adjust the value and press button to confirm. 2B3.9 Load Default Press and button to [Load Default] interface, see Figure 3.16. - - - - - - Low Load Default Figure 3.16 Shineway Technologies, Inc. - 14 -

Press button to load default settings, see Figure 3.17. Loading... - - - - - - Low Load Default Figure 3.17 32B3.10 Language Setting Press and button to [ 语言 /Lang.] interface, see Figure 3.18. -6.50 语言 /Lang. Figure 3.18 Press button to toggle between English and Chinese interface. 42B3.11 Auto Off Press and button to [Auto Off] interface, see Figure3.19. -6.50-6.50 Auto Off Auto Off Figure 3.19 Press button to enable or disable Auto Off function. Shineway Technologies, Inc. - 15 -

4B4. Calibration 52B4.1 Optical Interface Cleaning Optical interface must be always kept clean. Always put protective dust cap on when the unit is not in use, and keep the protective dust cap clean. 62B4.2 Calibration Requirements Calibration of the instrument is recommended every 3 years. Please contact our representatives or customer service centers for proper calibration. Shineway Technologies, Inc. - 16 -

5B5. Specifications Model OPM-50 A B Calibrated Wavelength 850,1300,1310,1490,1550,1625nm Power Range () -70 ~ +10-50 ~ +27 Application Range Singlemode/Multimode fibers Detector Type InGaAs Accuracy ±0.25 db (5%) @25ºC & -10 (±0.5 db@850nm) Resolution (db) 0.01 MOD Identification 270,1K,2K Hz Auto Wavelength Identification Yes (With SLS-50) Display Unit W/mW//dB(REF) Data Storage 1000 records Connectivity Connector Power Supply Battery Life Power Saving USB FC (Interchangeable SC/ST) Lithium Battery/ AC Adapter Continuous operation 125 hours; Standby 250hours Auto-off after 5 minutes idle Operating Temperature 0ºC ~ 50ºC (32 ~ 122 F) Storage Temperature -20ºC ~ 70ºC (-4 ~ 158 F ) Relative Humidity Weight Dimensions (H W T) 0 ~ 95% (Non-condensing) 315g (0.69 lbs) 177 80 44mm (6.97 3.15 1.73 inch) TNote:T (1) For Model A at 850nm, the lower limit of measurement range is -60. (2) OPM models with Ф1000μm detector are available with: FC/SC/ST/DIN/E2000/LC/Universal 1.25mm/Universal 2.5mm connectors. * Specifications subject to change without notice Shineway Technologies, Inc. - 17 -

6B6. Warranty Information 72B6.1 Warranty Period All ShinewayTechP P products are warranted against defective material and workmanship for a period of one (1) year from the date of shipment to the original customer. Any product found to be defective within the warranty period would be repaired or replaced by Shineway Technologies Inc free of charge. In no case will Shineway Technologies, Inc liabilities exceed the original purchase price of the product. 82B6.2 Exclusion The warranty on your equipment shall not apply to defects resulting from the following: Unauthorized repair or modification Misuse, negligence, or accident Shineway Technologies, Inc. reserves the right to make changes to any of its products at any time without having to replace or change previously purchased units. 92B6.3 Warranty Registration A warranty registration card is included with the original shipment of equipment. Please take a few minutes to fill out the card and mail or fax it to the local Customer Service Center of Shineway Technologies, Inc. for your product warranty activation. 03B6.4 Returning Instrument To return instrument for yearly calibration or other purposes, please contact the local Customer Service Center of Shineway Technologies, Inc to obtain additional information and a RMA (Return Materials Authorization) number. And describe brief reasons for the return of the equipment to help us offer you efficient services. To return the instrument in the case of repair, calibration or other maintenance, please note the following: Shineway Technologies, Inc. - 18 -

Be sure to pack the instrument with soft cushion like Polyethylene, so as to protect the shell of the instrument. Please use the original hard packing box. If you use other packing material, please ensure at least 3 cm soft material around the instrument. Be sure to correctly fill out and return the warranty registration card, which should include the following information: company name, postal address, contact, phone number, email address and problem description. Be sure to seal the packing box with exclusive tape. Be sure to ship to your representative or agent of Shineway Technologies, Inc in a reliable way. 13B6.5 Contact Customer Service Please check our web site (www.shinewaytech.com) for updates to this manual and additional application information. If you need technical or sales support, please contact local Shineway Technologies Customer Service. Shineway Technologies (China), Inc.: Address: Fl.7, Zhongtai Plaza, No.3 Shuangqing Rd, Haidian District, Beijing, China Postal code: 100085 Tel: +86-10-62953388 Fax: +86-10-62958572 Email: support@shinewaytech.com Website: www.shinewaytech.com THANK YOU FOR CHOOSING SHINEWAY TECHNOLOGIES! DOC.P/N:MAN-OPM-EN. V300. 04/10 Shineway Technologies, Inc. - 19 -