Skywire Miner. Assembly Manual. Contact. . #1101 South Tower, No.1839 Qixin Road, Minhang, Shanghai, P.R.

Similar documents
Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

TRC-190 User s Manual

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

2260B-RMK-Series Rack Mount Kit

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

TRC-190 User s Manual

HV-CS kv Edge Mount Triaxial Jack

User Manual. N Series 1U LCD Keyboard Drawer 17", 19" screen size. Models NRKD-KVM-17 / 19 Series. Models NRKDS-KVM-17 / 19 Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

MC 11 EB-2 Power supply cabinet with external bus, AC version

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Model 7705 Control Module

MPP200 User s Manual

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

M215-Z Safety Information (M LL-IG-ZC)

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

M215 (M215-60) Safety

Digital Overhead Stirrer

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

SATA II HDD Canister KISS DA 435 Quick Reference Guide

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

EC Series. Safety Guide

Model 2657A-LIM-3 LO Interconnect Module

DOT MATRIX PRINTER SP6000 SERIES

CMSA-100 Manual. Cinema Media Server Automation

B63/ NS MS. EtherNet/IP LINK

M250 (M LL) Safety

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number:

7" Touch Screen Display

User Guide. Control Box. RoscoLED TM.

Operating Instructions

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Octostrip ORDERCODE 42220

Start Here. All-in-One Printer. Print Copy Scan

MPP1700 User s Manual

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Light as soft as a cloud.

powerbrite led Lighting Systems & Modules

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1.

3-Lamp Fluorescent Ring Light 19" INSTRUCTIONS

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Toll Free: Tel: Fax:

Enphase S-Series Microinverter and Engage Cable Safety

EPS Power Supply

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

DS-1H05 Ethernet-over-Coax Extender. User Manual

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Warnings & Guidelines:

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

USERS GUIDE ASP-18H-4K. HDMI 4K2K 1x8 Splitter with EDID Management. Manual Number:

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

16-SLOT IN-BAND MANAGEMENT CHASSIS

13 MMC for PC Option Modules

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

NuMount VESA. Adapter for imac ASSEMBLY MANUAL

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

FOR FURTHER INFORMATION CONTACT: Music Hall 108 Station Road Great Neck, NY Tel: Fax:

LED FOLDING WORKLIGHT TM

1 Channel Strobe Controller ORDERCODE 40226

User s Manual USB 3.0 Expansion Card TS-PDU3

Analog Monitor Installation Manual

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

NETWORKS DATA CENTER SWITCHES USER MANUAL

Model 4001A Modular System Bin Operating and Service Manual

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

RMB Peripheral Units Installation Guide

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

Charging Cabinet Owner s Manual

i-series Videoconference Fixture

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

Thank you for choosing Xcellon.

Vacuum Tubes Power Supply Unit. for WA7 and WA7d Fireflies. Owner s Manual. Please review this manual before operating your WOO AUDIO product.

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Operating Instructions

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Transcription:

Skywire Miner Assembly Manual Contact Address #1101 South Tower, No.1839 Qixin Road, Minhang, Shanghai, P.R.C Website www.skycoin.net Email support@skycoin.net

SKYWIRE MINER OVERVIEW 01

CONTENTS ASSEMBLY MANUAL 02 FOREWORD 03 SCREWS & PARTS 07 FRAME ASSEMBLY 08 ELECTRONIC ASSEMBLY 11 FINAL ASSEMBLY 20 CABLE CONNECTION 27

FOREWORD WARRANTY 03 Introduction Skywire Miner is groundbreaking technology that redirects the control of large Internet service providers (ISPs) and helps individuals leverage that power. The Skywire Miner peer-to-peer model promotes net neutrality and content sharing, without imposing any blocking, performance decrease, or censorship. Skywire Miner is built with an openaccess network than ensures privacy and encourages free speech. Our mission in creating Skywire is to shape the future of the Internet for the better. Our revolutionary networking protocol is already changing the Internet as we know it. The protocol is based on Multi-Protocol Label Switching (MPLS), which includes benefits of higher performance, better quality of service, more reliability, and greater security. Skywire Miner goes well beyond these standards to deliver an even faster network that is optimized for high performance and maximum privacy. A user can bypass the ISPs and maintain control of their Internet access experience effectively operating as an independent ISP. Warranty Thank you for your interest and trust in the Skywire Miner. In using the product, you are obliged to install and operate the Skywire Miner according to the safety instructions, warnings, specification sheet, and assembly manual as well as common sense. Otherwise, the Skycoin team won t be responsible for any property losses or personal injuries caused by failure to understand the proper use of the product. Since this is the first version of the Skywire Miner built especially for early-adopter customers you may face an unexpected situation. We appreciate your patience in dealing with such scenarios. The Skycoin team stands ready to help, and remains willing to offer the most appropriate solution to address any product defect. This includes a warranty that covers, as necessary, free repair, replacement of parts*, or replacement of the entire product. Warranty terms: This manufacturer warranty covers any defects in material or workmanship that may occur under normal use within a period of one (1) year from the purchase date. When you discover any defects with the Skywire Miner, stop all operation and contact the Skycoin team immediately to obtain warranty coverage. You may reach the Skycoin team here at: warranty@skycoin.net Exclusions: There is absolutely no coverage for accidents, fire, or water damage, acts of nature or external forces, or damage caused by repairs, unauthorized upgrade attempts, or removal of components. This warranty does not cover cosmetic damage. This warranty does not apply to products that have been lost, altered, broken or damaged by misuse or

FOREWORD SAFETY 04 failure to follow instructions provided with the product. Also, there is no warranty against normal wear. Remedy terms: At its discretion, Skycoin will make remedy through replacement or repair of defects in either materials and or workmanship. Return shipping costs are the responsibility of the original purchaser. Warranty period: All warranty claims must be reported to the manufacturer during the one year warranty period from the date of purchase to be eligible for coverage. Safety It s important that you assemble and operate this product and all components in strict accordance with the instructions in this manual. Handling circuit boards Exercise extreme caution while handling printed circuit boards (PCBs) to avoid mechanical or electrical damage. Only handle the PCBs by the edges, to minimize the risk of electrostatic discharge damage. Proper voltage Before connecting the power cord, ensure that you switch to the correct input range on the power supply unit that corresponds to the voltage that your electrical outlet provides. Firm connections Before powering up the Skywire Miner, ensure that all connections are secure for all components, and confirm that there are no loose screws or loose components anywhere within the Skywire Miner unit. Do not connect any devices to the Skywire Miner that are not included in this package. Precautions take time to consider situations that may be dangerous or cause damage: During operation, do not expose Skywire Miner to water or moisture. Do not expose Skywire Miner to heat from any source. This appliance is designed for reliable operation at normal ambient room temperatures. Do not tug in the middle of the power supply cable to unplug the unit. Unplug the Skywire Miner from the end of the cable, where the plug inserts into the socket. Place Skywire Miner where the power cord has adequate slack to safely connect the Skywire Miner to the power supply socket. Place the power cord in such a way that people cannot step on it. Do not place anything over the power cord.

FOREWORD WARNING 05 If any of the following situations occur, stop using the Skywire Miner immediately and contact support to make arrangements to check your unit: Liquid has penetrated into the Skywire Miner. The Skywire Miner has been exposed to moisture or heat. The Skywire Miner does not work well, or it does not function according to the content in the user guide. The Skywire Miner has been dropped and damaged. The Skywire Miner has obvious breakage. Warning! Always unplug the power cord from the power outlet before installing any component into this appliance or removing anything from this appliance. When the power is on, do not contact any conductive objects with any Skywire Miner components. Do not touch the Skywire Miner with any wet part of your body, and do not operate the Skywire Miner while barefoot. The Skywire Miner is not intended for use by children. Nor is it intended for use by persons that exhibit any physical, sensory, or mental impairment, or persons lacking experience and knowledge of the Skywire Miner unless supervised or previously instructed in its use by those responsible for their safety.

FOREWORD SPECIFICATION 06 Specification Sheet of Skywire Miner Build 2.0 Physical Net Weight Chassis Demensions (LxWxH) Shipping Weight Shipping Dimensions (LxWxH) Structure Materials Computing Unit Quantity Computing CPU Model Computing Core Quantity GPU Model RAM (Shared with G-RAM) Storage Network LAN Bandwidth LAN Ethernet Cable Type Electrical AC Input Voltage AC Input Frequency Max Input Current Max Inrush Current Fuse Current Backup Fuse Input Plug Type Power Cord Standard Power Connector Type Environmental Working Temperature Working Humidity Storage Temperature Storage Humidity 4 kg (9 lbs) 235x235x275 mm (9.5x9.5x11 inch) 4.5kg (10 lbs) 320x320x190 mm (12.5x12.5x7.5 inch) Aluminum Alloy & Acrylic 8 ARM Cortex -A53 32 Hexa-core Mali450 16GB (32 x 512MB DDR3) 8 x 16GB Class-10 A1 Micro SD 8 x 100Mbps CAT-6 85~132V / 170~264V 47~63Hz 2.4A @115V AC / 1.2A @ 230V AC 30A @115V AC / 60A @230V AC 3A Included IEC 60320 C14 GB/T 5023.3-2008 NEMA 5-15 or GB1002-2008 1-Phase 2-Pole Earthed -10 C~40 C (14 F~104 F) 20%~90% RH -20 C~60 C (-4 F~140 F) 10%~95% RH

SCREWS & PARTS SCREWS AND PARTS 07 0510 0406 0302 0310 0312 12x 4x 8x 20x 8x 0303 10x MICRO SDCARD 3216 1028 0336 0326 0320 0402 0502 0508 52x 24x 8x 8x 4x 64x 8x 26x

STEP 01 FRAME ASSEMBLY 08 1194 Shorter Aluminum Profile 0508 M5x8mm Hex Screw 0502 M5 T-Nut 1028 Corner Bracket 0508 0502 1028 2x 2x 2x 6x 9930 1194

STEP 02 FRAME ASSEMBLY 09 1234 Longer Aluminum Profile 0508 M5x8mm Hex Screw 0502 M5 T-Nut 0508 0502 6x 6x 2x 9930 1234 1234

1234 STEP 03 FRAME ASSEMBLY 06 10 1234 Longer Aluminum Profile 0508 M5x8mm Hex Screw 0502 M5 T-Nut 1028 Corner Bracket 0502 1028 16x 16x 8x 9930 0508 1234 1234 1234

STEP 04 ELECTRONIC ASSEMBLY 11 2002 Acrylic Inner Panel 0310 M3x10mm Hex Screw 0320 20mm F-F Spacer 0310 0320 8x 8x 9805 9925 2002! Strip the protective film before using acrylic panels.

STEP 05 ELECTRONIC ASSEMBLY 12 5011 Power Supply Unit 0310 M3x10mm Hex Screw 0303 M3 Nylon Spacer 0310 0303 4x 4x 9925! Switch the power supply unit to proper voltage range before mounting.! Mind the direction of power supply unit, connector side down.! If some of the screws can t grab the holes, use 0312 instead.

STEP 06 ELECTRONIC ASSEMBLY 13 4100 Orange Pi Prime 0336 30mm F-M Spacer 0336 24x 9805! It is suggested to flash and insert Micro SD before mounting the Orange Pi Prime.

STEP 07 ELECTRONIC ASSEMBLY 14 2003 Acrylic Outer Panel 4100 Orange Pi Prime 0310 M3x10mm Hex Screw 0326 20mm F-M Spacer 0310 0326 8x 8x 9805 9925 2003

STEP 08 ELECTRONIC ASSEMBLY 11 15 2001 Acrylic Back Panel 5001 Power Socket 0312 M3x12mm Hex Screw 0302 M3 Nut 0312 0302 2x 2x 9925 2001! Ensure the switch is off, and DO NOT plug the power cord.

STEP 09 ELECTRONIC ASSEMBLY 16 5020 Power Distribution Board 0312 M3x12mm Hex Screw 0510 M5x10mm Hex Screw 0303 M3 Nylon Spacer 0302 M3 Nut 0502 M5 T-Nut 0312 0510 0303 0302 0502 6x 2x 6x 6x 2x 9925 9930

STEP 10 CABLE CONNECTION 17 DC Cable 7011 DC Cable 7012 DC Cable 7013 DC Cable 7014 DC Cable 7020 AC Cable 7021 AC Cable 7022 Earthing Cable 7024 AC Cable! Check the cable codes carefully.! Leave the leftmost tab on the power socket UNUSED (in green circle. 7013 7014 7024! Cable 7011, 7012, 7013, 7014 should be crimped onto the PCB with pliers for solid connection. 7011 7012 7020 7021 7022

STEP 11 ELECTRONIC ASSEMBLY 13 18

STEP 12 ELECTRONIC ASSEMBLY 19 0510 M5x10mm Hex Screw 0502 M5 T-Nut 0510 0502 2x 2x 9930

STEP 13 FINAL ASSEMBLY 20 0502 M5 T-Nut 0502 4x! Put the nuts into the slot for later use.

STEP 14 FINAL ASSEMBLY 21

STEP 15 FINAL ASSEMBLY 22 0510 M5x10mm Hex Screw 0510 4x 9930! Shake carefully to align the nuts to the holes.

STEP 16 FINAL ASSEMBLY 23 3000 Router 0406 M4x6mm Hex Screw 0402 M4 T-Nut 0406 0402 4x 4x 9925

STEP 17 FINAL ASSEMBLY 24 0508 M5x8mm Hex Screw 0502 M5 T-Nut 1028 Corner Bracket 0502 1028 12x 16x 6x 9930 0508! This step is based on the structure indicated on page 9.

STEP 18 FINAL ASSEMBLY 25! Loose and re-tighten all the screws on the vertical pillars, helping release the stress in the structure.

STEP 19 FINAL ASSEMBLY 26 0510 M5x10mm Hex Screw 0510 4x 9930

STEP 20 CABLE CONNECTION 27 7011 DC Cable 7012 DC Cable 7020 AC Cable 7021 AC Cable 7022 Earthing Cable 7023 Earthing Cable 7033 DC Cable 7033 9930! Check the cable codes carefully. 7012 7011 7022 7021 7020 7023

STEP 21 CABLE CONNECTION 28 6020 Ethernet Cable 6025 Ethernet Cable 7033 DC Cable 6020 7033 6025

STEP 22 CABLE CONNECTION 29 DC Cable