Controlling a SERVOLASER Xpert via a Bosch Rexroth IndraLogic XLC L45 using the Ethernet/IP protocol

Similar documents
Using the WAGO as Remote I/O with an Omron SYSMAC CJ2 Series PLC. Application note. A116700, English Version 1.1.0

IndraLogic L Controller based

Documentation for. TwinSAFE User. Tool to modify the User Administration of a TwinSAFE Logic. Version: Date:

Manual. Software Protection. TwinCAT 3. Version: Date:

Video Management System SeMSy III Setup Server

CM-EIP-1 G9SP Safety Controller EtherNet/IP Adapter Application and Setup Guide

SeMSy III Interface Server / Clients

SeMSy III Interface Server / Clients

PTZ Control VMC Joystick

PLC. IndraLogic L Controller-based

Installation Manual ASIP. LAN-Module 508

Remote Configuration Software DMS NetConfig 2

S7-200 PPI Monomaster Remote connection How To

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Configuration. English. Video Management System. SeMSy III Modul Map. Rev /

PLC. IndraLogic L Controller based

Guidelines of Ethernet for Using a Star Dvice. - Windows - Rev. 2.0

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

EtherNet/IP DEVICE CONFIGURATION. A Step by Step Guide

GMG WebClient Quick Start Guide (EN)

Installation. English. Viewing Client. Rev /

Manual. PLC Lib: Tc2_DMX. TwinCAT 3. Version: Date:

CPX-FB36 in Ethernet/IP Mode

Manual. TC3 Virtual Serial COM. TwinCAT 3. Version: Date: Order No.: TF 6360

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Protocol Gateway IEC Master/Slave IEC Client/Server

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Control hardware. IndraControl L75

Video Management System SeMSy III Workstation Software

Operation. English. Recording Server. WebConfig. Rev /

Quick Guide. English. Appliance. SMAVIA Enterprise JBOD. Rev /

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Operating a Power Xpert C445 Global Motor Management Relay with a Rockwell PLC via Ethernet/IP

Using WAGO Series 750 DeviceNet IO with an A-B SLC SDN Scanner Application note

Using WAGO Series 750 DeviceNet IO with an A-B ControlLogix 1756-DNB Scanner Application note

Your Global Automation Partner. Startup. Getting Started Guide

User Manual Gateway component for EtherNet/IP

PMS 138 C Moto Black spine width spine width 100% 100%

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT

Installation & Activation. English. Recording Server / Rev /

Motion logic system. IndraMotion MLC Control hardware IndraControl L

CJ Series EtherNet/IP TM Connection Guide. SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01

Using the WAGO as Remote I/O with a ControlLogix Ethernet/IP Bridge Module Application note

Main Functions. English. Viewing Client

Quick Start Guide NETL ink Ethernet Gateways

Motion-Logic system. IndraMotion MLC Controller based

Port Forwarding Setup (RTA1025W Rev2)

SCE Training Curriculum

WAGO Remote IO with Fanuc Robot using EtherNet/IP Protocol Application note

Guidelines of Ethernet for Using a Star Device. - Mac OS X - Rev. 3.0

Manual. PLC Lib: Tc2_SMI. TwinCAT 3. Version: Date:

Manual. TC3 Power Monitoring. TwinCAT 3. Version: Date: Order No.: TF3650

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Sherpa R-IN32M3 EtherNet/IP adapter communication stack for Renesas Electronics Corporation s R-IN32M3 series industrial Ethernet controller

Synchronized motion control functionality IndraWorks The Tool for All Engineering Tasks

TC3 Interface for Matlab /Simulink

HMI/industrial PC. Plug-in card Sercos master module Sercans

Festo Field Device Tool FFT. Description. Online help FFT f [ ]

QuantStudio 3D AnalysisSuite Server System

Anybus X-gateway EtherNet/IP

Open the dmg file USBCDC-OS10_4-Installer.dmg located in the CDC ECM folder. The package should be visible.

For the configuration of the I/O-modules in a control system an EDS-file is required. The names of the files are as follows:

samos PRO Gateways Operating instructions Doc. No. BA Issued: 06/2012 (Rev. C) 2012 Wieland Electric GmbH

County of Sacramento Instructions for filling out an online Tree Permit

FAQs for Background. 1. What is Open Core Engineering?

PSoC Creator Quick Start Guide

Operation. English. Detection And Evaluation Of Licence Numbers. SEDOR ANPR Server. Rev /

Kurzweil 3000 for Macintosh Network Installation and Administration Guide Version 4

MP8000 SOFTWARE Instruction Manual

Application Notes for Ardence Desktop Edition with Avaya Interaction Center Issue 1.0

Instruction Manual. Vimar By-web Software for Android mobile devices User Manual

Network Guide NPD EN

Cypress BLE-Beacon ios App User Guide

Configuration and Operation. English. PStreamConvert. Application for the Analysis and Conversion of Backups. Rev. 2.0.

SeMSy III Failover Server

DeviceNet Communications

Using the WagoAppEtherNetIP_Adapter library with a CompactLogix Controller A500930

Set-up for a Netgear DG834G (802.11b & g) ADSL Router with the Adpro FastTrace

Operating Instructions Firmware Update Guide

Tritex II EtherNet/IP - Option

LaserJet Pro M501 Getting Started Guide

How to upgrade the firmware

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

Controlsoft Identity and Access Management Software Controlsoft Identity Access Management Software

N30 Supervisory Controller Quick Start

Set-Up Guide for Lightning Experience of Salesforce.com

Manual. PLC Lib: Tc2_Drive. TwinCAT 3. Version: Date:

Configuration and Operation. English. DMVC App. Client Software for Dallmeier Recording Systems and DMVC Server

Anybus CompactCom 40 Diagnostic Events for EtherCAT SCM ENGLISH

Setting up a secure VPN Connection between CP x43-1 Adv. and SOFTNET Security Client Using a static IP Address

GuardLogix Controller to Kinetix 6000 Drive with Safe-Off using EtherNet/IP CompactBlock Guard I/O Module

G9SP Ethernet IP Communication to Omron s NJ5 PLC s Rev1.0 Mike Wash

Use of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016.

2 Bosch Rexroth AG Electric Drives and Controls. Technical data. PLC IndraLogic XLC. Documentation Documentation

Video Management Software PView 7

MTC200/ISP200/TRANS200 Setup. Application Manual SYSTEM200 DOK-CONTRL-SETUP***V22-AW02-EN-P

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

Application Note FC1100/FC1121 (EtherCAT Slave Card)

Firmware Flash Upgrade Wizard. User Manual

Transcription:

White paper Controlling a SERVOLASER Xpert via a Bosch Rexroth IndraLogic XLC L45 using the Ethernet/IP protocol Please read carefully prior to commissioning! Keep this document for future reference. Translation of the original LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert positioning system All brand names and product names are trademarks or registered trademarks of the respective title holder. LAP GmbH Laser Applikationen, Lüneburg, 2016 The reproduction, distribution and utilisation of this document as well as the communication of its contents to others without express authorisation are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. This document is intended to be used by the owner of the LAP product, his/her users and contractual partners of LAP. It must not be handed to other persons or made available to third parties. This document is subject to a document content service and subject to change without prior notice. LAP can assume no liability for the correctness, completeness or upto-dateness of any laws, regulations or guidelines (e.g. DIN, VDE,...) referenced directly or indirectly or quotes taken from such sources in this publication. We recommend that the complete regulation or guideline in the latest valid version be consulted for work to be carried out, where applicable. Subject to technical changes. 2 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 Table of contents 1 Introduction... 4 1.1 System configuration and purpose of the white paper... 4 2 Configuring the Ethernet/IP connection... 7 2.1 Assigning an IP address for the programming PC... 7 2.2 Assigning an IP address to the Xpert using BOOTP/DHCP Server... 9 2.3 Downloading the Xpert EDS file... 11 2.4 Cabling and configuration of the overall system... 12 3 Creating an IndraWorks project... 13 4 Application example... 21 4.1 Creating the variable table... 21 4.2 Uploading the program to the PLC... 22 5 Summary... 23 6 References... 24 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 3

SERVOLASER Xpert positioning system 1 Introduction 1.1 System configuration and purpose of the white paper The purpose of this document is to present an application example for commissioning and programming a SERVOLASER Xpert positioning system, hereinafter referred to as "Xpert". References are made to the corresponding installation and operation manual (MAN-1282 Rev 4-en-GB) [1]. The hardware of the test system for commissioning consists of the following: SERVOLASER Xpert SLX-S-M-2-1-2-L1-D4-1,7-IE-1-1 IndraLogic XLC L45 model CML45s-XLC-13V12.0573.001 HP PC with 8 GB RAM and Windows 7 Professional The following programming software is used: IndraWorks ML* 13V12.0079.07 BOOTP/DHCP Server 2.3 The components used and the system configuration are shown in Fig. 2-3. SERVOLASER Xpert PC IndraLogic XLC L45 Ethernet Fig. 1-1: System configuration and Ethernet/IP cabling 4 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 The Xpert has its own controller with an Ethernet/IP port and two movable laser modules (Fig. 1-2). Two devices can be connected to form a system with up to four movable lasers. An additional fixed laser, which is installed in the centre, is optional. This fixed laser is positioned above the linear rail. This enables the movable laser modules to use the entire travel range. Three different laser colours are available, i.e. can be configured (red, green, blue). The laser colours can be combined in any way. Maximum visibility in different lighting conditions and on different projection surfaces can be ensured by the choice of laser colour. The laser modules are available with different aperture angles. The standard aperture angle is 90 for red and green lasers and 70 for blue lasers. The different laser classes provide different levels of laser power. The maximum possible laser output power of the Xpert is 40 mw. Models with a maximum laser output power corresponding to the permitted limit are available for each laser class. The dimming function allows you to set each individual laser module separately to your optimum visibility. Fig. 1-2: SERVOLASER Xpert LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 5

SERVOLASER Xpert positioning system This white paper is structured to follow the procedure during commissioning. In principle, a different sequence of steps would be possible in some places, but a modified order of steps during Ethernet/IP configuration and the assignment of IP addresses has generally led to problems. Therefore, it is recommended that you adhere to the sequence of steps specified here. First you must connect the Xpert directly to the programming PC. This step is necessary because when the Xpert is subsequently connected with the PLC, you will no longer be able to access the integrated web server. Then you assign an IP address for the programming PC and the Xpert as well as check the Ethernet/IP connection. In the second step, download an electronic data sheet (EDS file) of the Xpert via the Xpert web server. The EDS file contains all communication parameters of the device as well as the available objects. The DeviceNet configuration tool imports the EDS files of the devices available in the network and uses them to calculate the configuration data which are subsequently loaded onto the DeviceNet participants. In the third step, connect the system cables as shown in Fig. 1-1. You then assign an IP address for the programmable logic controller. After that the IP address of the programming PC must be adapted to the IP address of the PLC. In the fourth step, create a new IndraWorks project and add the hardware. Select the IndraLogic XLC L45 used here as the device type and define the IP address. Only the two real-time Ethernet interfaces X7E3/X7E4 are needed for the interfaces. Next to the port designation, select an Ethernet/IP scanner, which functions as a master here. Once you have completed the configuration, you must set the Ethernet/IP scanner parameters and import the previously downloaded EDS file. The last chapter of the white paper shows an application example for controlling the movements. It deals with the creation of a variable table for controlling the incoming data packets and for reading the outgoing data packets of the Xpert. It also describes the procedure for loading the project onto the programmable logic controller. All steps from configuring the Ethernet/IP to creating the finished program are described in detail in the following chapters. 6 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 2 Configuring the Ethernet/IP connection 2.1 Assigning an IP address for the programming PC First you must connect the Xpert directly to the programming PC as shown in Fig. 2-1. This is the only way to access the integrated web server of the Xpert and download the EDS file. SERVOLASER Xpert PC Ethernet Fig. 2-1: Connection between Xpert and programming PC To assign IP addresses, in this case the IP address of the Xpert, you must first appropriately set the IP address of the programming PC. In this application example the IP address 192.168.200.20 was assigned to the programming PC. This is done as shown in Fig. 2-2: Control Panel > Network and Internet > Network and Sharing Center > Change adapter settings > Local Area Connection > Properties Internet Protocol Version 4 (TCP/IPv4) > Properties > Use the following IP address: 192.168.200.20 > OK LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 7

SERVOLASER Xpert positioning system Fig. 2-2: LAN connection and Internet protocol properties on the PC 8 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 2.2 Assigning an IP address to the Xpert using BOOTP/DHCP Server Next, assign an IP address to the Xpert via the BOOTP/DHCP Server software. When the BOOTP/DHCP Server 2.3 software is started, it scans the MAC addresses of all connected devices (Fig. 2-3). The identified participants and their MAC addresses are displayed in the Request History window. Select the Xpert MAC address and click Add to Relation List to confirm. Fig. 2-3: Search for the Xpert MAC address using BOOTP/DCHP Server 2.3 Then BOOTP/DHCP prompts you to enter the IP address (Fig. 2-4), which must be in the same subnet as the programming PC. In our application example IP address 192.168.200.21 was assigned to the Xpert. If the entry has been confirmed, the MAC address and IP address are displayed in the Relation List window. If everything was successful, the [Enable DHCP] Command successful message is displayed in the Status window at the bottom left of the screen (Fig. 2-5). Following this message, a ping can be sent from the DOS window to the Xpert to check accessibility (Fig. 2-6). LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 9

SERVOLASER Xpert positioning system Fig. 2-4: Assigning an IP address to the Xpert using BOOTP/DHCP Server 2.3 Fig. 2-5: BOOTP/DHCP Server after DHCP activation Fig. 2-6: Checking the accessibility of the Xpert by sending a "ping" 10 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 2.3 Downloading the Xpert EDS file In order to include the Xpert EDS file in the IndraWorks project later, you must first download it from the integrated Xpert web server. To do so, open a web browser and enter the IP address of the Xpert (see chapter 2.2) as the web address. Right-click the file and select Save target as to download the EDS file (Fig. 2-7 and Fig. 2-8). Fig. 2-7: Xpert web server Fig. 2-8: Downloading the Xpert EDS file LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 11

SERVOLASER Xpert positioning system 2.4 Cabling and configuration of the overall system After you have successfully downloaded the EDS file from the integrated web server, connect the cables of the overall system as shown in Fig. 1-1. Then set the Ethernet X7E5 programming interface to which the programming PC is connected to the programmable logic controller using the arrow buttons (Fig. 2-9) [2,3]. In our application example IP address 192.168.1.32 is assigned to the programming interface. It is important that this IP address be located in a different subnet to the IP address of the Xpert, since otherwise IP communication conflicts could occur. Fig. 2-9: Configuration of the Ethernet X7E5 programming interface Then you must reassign the IP address of the programming PC in the subnet of the programmable logic controller. The procedure for assigning a new IP address to the programming PC is described in chapter 2.1. In our application example the new IP address 192.168.1.10 is assigned to the programming PC. Tab. 2-1 shows all assigned IP addresses and the corresponding systems. System IP address Programming PC 192.168.1.10 Programmable logic controller 192.168.1.33 SERVOLASER Xpert 192.168.200.21 Tab. 2-1: All assigned IP addresses 12 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 3 Creating an IndraWorks project If the cables of the overall system have been connected and an IP address has been assigned to each system, you can then open the IndraWorks software and create a new project [4,5]. In the Project Explorer in the left column, right-click the project name and select Add > IndraLogic XLC L45 (Fig. 3-1). Fig. 3-1: Creating a new project in IndraWorks LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 13

SERVOLASER Xpert positioning system This automatically opens a window for configuring IndraLogic XLC L45 (Fig. 3-2). In the Step 2: Configuration window, specify the firmware version as well as the IP address and type of the device. The IP address was already assigned in chapter 2.4 and must only be copied to the software. In our application example IP address 192.168.1.33 is entered. You can then execute a connection test in this window. Fig. 3-2: Configuring IndraLogic XLC L45 When you have copied the settings and successfully executed the connection test, you configure the ports in the next window, Step 3: Interfaces (Fig. 3-3). In our application example only the two Realtime Ethernet interfaces X7E3/X7E4 are needed. In the selection list next to the port designation, select an Ethernet/IP Scanner, which functions as a master here. Then click Finish to complete the configuration. 14 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 Fig. 3-3: Configuring the interfaces You have successfully created the project and now you can open it in the Project Explorer. The Ethernet/IP scanner was also created (Fig. 3-4). You need only to set its parameters. Fig. 3-4: Ethernet/IP Scanner has been created successfully Double-click the Ethernet/IP scanner to open the Scanner settings tab (Fig. 3-5). Select the Used fixed IP-Address: option. The IP address must be in the same subnet as the IP address of the Xpert. In our application example the address 192.168.200.100 is selected, since the address 192.168.200.21 was assigned to the Xpert in chapter 2.2. LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 15

SERVOLASER Xpert positioning system Fig. 3-5: Configuring the Ethernet/IP scanner After a new IndraWorks project has been created and the Ethernet/IP scanner has been configured, you can now import the Xpert EDS file. To do so, from the main menu select Tools and then the Device Database tab (Fig. 3-6). Fig. 3-6: Opening the device database You can install and uninstall device description files in the device database. The devices which are currently installed are listed in the Available devices section. To add a new device, click Add Devices (Fig. 3-7). 16 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 Fig. 3-7: Device database First select the EDS and DCF files search option. Then select the Xpert EDS file and click Open to add it (Fig. 3-8). Fig. 3-8: Opening the Xpert EDS file The Xpert has now been automatically added to the list of available devices. LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 17

SERVOLASER Xpert positioning system Fig. 3-9: Updated device database To add the Xpert to the project, right-click the Ethernet/IP scanner in the Project Explorer and select the following path (Fig. 3-10): Add > Add device > Generic Device > ServoXpert Ether- Net/IP Fig. 3-10: Adding the Xpert to the project The device has now been added. Double-click the ServoXpert_Ethernet/IP in the Project Explorer to set the Xpert parameters. The IP address here must match the configured address of the Xpert (Fig. 3-11). In our example, the IP address is 192.168.200.21. 18 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 Fig. 3-11: Configuring the Xpert Then select the Connections tab and click Add Connection (Fig. 3-12). Fig. 3-12: Add Connection Here you must click the Exclusive Owner row. In the New connection window, make the following settings as shown in Fig. 3-13: Due to the program cycle time, set RPI to 20ms Set the Target to Scanner text box to 256 bytes Leave the default values for the remaining setting options. LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 19

SERVOLASER Xpert positioning system Fig. 3-13: Connection settings When you create a new connection with the settings shown, the input and output words on the EthernetIP I/O Mapping tab are also automatically created. The Always update variables option must always be ticked (Fig. 3-14). The definition and structure of the input and output data words for controlling and monitoring the Xpert are described in the relevant installation and operation manual (MAN-1282 Rev 4-en-GB). This ends the hardware configuration. The last chapter of the white paper shows an application example for controlling the Xpert. Fig. 3-14: EthernetIP I/O Mapping 20 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 4 Application example 4.1 Creating the variable table The Xpert can be controlled only byte by byte via the EthernetIP I/O Mapping of the Ethernet/IP scanner. For this reason a variable table is created in this step. With this table you can more easily and more conveniently control and read the individual variables of the incoming and outgoing data packets. To create the table, in the Project Explorer double-click the PlcProg (PRG) module (Fig. 4-1). Fig. 4-1: Creating the variable table in the PlcProg module You declare the input and output variables in this module. The variables are described in the relevant installation and operation manual (MAN-1282 Rev 4-en-GB). Fig. 4-2 and Fig. 4-3 show the declared input and output variables. Fig. 4-2: Declared output variables LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 21

SERVOLASER Xpert positioning system Fig. 4-3: Declared input variables 4.2 Uploading the program to the PLC To upload the program to the PLC, you must first compile the program, transfer it and then click the Start button to launch it (Fig. 4-4). Fig. 4-4: Uploading the program Click the Build button to compile the project. Then click the Login button to transfer the project to the programmable logic controller. After that you can click the Start button to launch the program. You can now write the input variables of the Xpert online and copy them to the PLC by pressing the Ctrl + F7 key combination (Fig. 4-5). Various parameters can be read via the Xpert output variables. Fig. 4-5: Online PLC program with writable variable table 22 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07

SERVOLASER Xpert Controlling via IndraLogic XLC L45 5 Summary This white paper presents an application example for commissioning and programming a SERVOLASER Xpert positioning system in connection with a Bosch Rexroth IndraLogic XLC L45 control system. The first chapter describes the hardware and software used as well as the purpose of the white paper. It also provides general information about the Xpert. The second chapter describes the settings of the Ethernet/IP connection on the programming PC as well as the assignment of IP addresses using the BOOTP/DHCP Server software. It then describes the downloading of the Xpert EDS file from the integrated web server to the programming PC. The last part of the second chapter describes the cabling and configuration of the overall Ethernet/IP network. The third chapter describes the creation of a new IndraWorks project, which contains the configuration of the programmable logic controller, the configuration of the Ethernet/IP scanner which functions as the master, as well as incorporation of the downloaded EDS file in the IndraWorks project. In addition it describes the settings and adding of a new connection with the Xpert. The last chapter describes an application example for controlling the Xpert. It deals with the creation of a variable table for controlling the incoming data packets and for reading the outgoing data packets of the Xpert. In addition it describes the procedure for uploading data to the programmable logic controller. In principle the Xpert and the Bosch Rexroth IndraLogic XLC L45 software have always worked together without problems or errors when the Ethernet/IP protocol is used and when the relevant installation and operation manual (MAN-1282 Rev 4-en-GB) and the points described in this white paper are adhered to. LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07 23

SERVOLASER Xpert positioning system 6 References [1] Installation and Operation Manual "MAN-1282 Rev 4-en-GB", LAP GmbH, Lüneburg, 2015 [2] Rexroth IndraLogic XLC 11 VRS First Steps, Bosch Rexroth AG, Lohr am Main, 2010 [3] Rexroth IndraLogic XLC 11 VRS System Overview, Bosch Rexroth AG, Lohr am Main, 2011 [4] Rexroth IndraWorks 11 VRS Software Installation, Bosch Rexroth AG, Lohr am Main, 2010 [5] Rexroth IndraWorks 11 VRS Engineering, Bosch Rexroth AG, Lohr am Main, 2011 24 LAP GmbH, MAN-1367 Rev 2 en-gb, 2016-07