IO1000. Type designation. Product description I/O module INSTALLATION MANUAL. Catalog no. from software version Document no I/O module 1.

Similar documents
Translation of the original operating instructions

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Serial PROFIBUS Interface

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

LDS3000. Type designation Product description Mass spectrometer module TRANSLATION OF THE ORIGINAL OPERATING INSTRUCTIONS

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

Operating Instructions VEGAMET 381

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

BMF400 Input/output module

EX-RC1 Remote I/O Adapter

CMC III Universal Sensor

EX-RC1 Remote I/O Adapter

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Industrial motor controller for brushed DC motors 24 VDC

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

OPERATING INSTRUCTIONS

Operating instructions. Speed monitor D / / 2014

Industrial motor controller for brushed DC motors 24 VDC

Operating instructions. Monitor FD / / 2013

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Expansion module EM-BAC-MOD-01. Installation manual

IF-80x Outdoor Terminal

Electronic Temperature Controller. Instruction Manual Version

EX-RC1 Remote I/O Adapter

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

CMC III Temperature/Humidity Sensor

B63/ NS MS. EtherNet/IP LINK

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

RMx621. Appendix to the operating manual

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

Short Instructions CG-S / IP-Router

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Manual Fiber Optic Interfaces

RMx621 /FML621. Appendix to the operating manual

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Expansion Module HZS 541-1S

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Optical laser distance sensors. Dimensioned drawing

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

E65C CU-E20, E22. User Manual. Communication Industrial and Commercial

Operating instructions. Switching amplifier DN0210 DN / / 2015

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

C9900-P208 and C9900-P209

MU110-6U. Analog output module 6 channel. User guide

Operating Manual FPGA-based High-Speed Micro-PLC

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

Square D Clipsal Pascal Automation Controller

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

BMD4032 Input/output module

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

Operating instructions. Monitor FS-2 / FS-2N / / 2013

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

Operating instructions. Standstill monitor A / / 2011

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Controller Smart Box Translation of operating and installation instructions

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

Access Terminal IF-800

MDM 011-Z1 Regen Resistor

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Component identification

Hardware Manual RM CANview

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

MINI MCR-SL-UI-2I(-SP)(-NC)

I/O module (Expansion module)

Operating instructions. Monitor FR-1 / FR-1N / / 2013

PHOENIX CONTACT - 05/2007

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

Siemens Drives & PLCs

Interface and Supply module. IPC 3x0i / PSC 3x0i

VR 80 Remote Control Device

Operating Instructions Differential Pressure Transducer PS27

Transcription:

INSTALLATION MANUAL IO1000 Type designation Product description I/O module Catalog no. from software version Document no. 560-310 I/O module 1.0 jiqc10en1-b (1301)

This document applies to the software version stated on the cover page. If you need a different version, please contact our sales staff. Reprint, translation and duplication need to be approved in writing by INFICON GmbH. 2

Content 1 About this manual.............................. 4 1.1 Target groups............................................ 4 1.2 Other applicable documents................................. 4 1.3 Presentation of information.................................. 4 1.3.1 Warnings......................................... 4 1.3.2 Text markings..................................... 5 2 Safety......................................... 6 2.1 Intended use............................................. 6 2.2 User requirements........................................ 6 2.3 User requirements........................................ 6 3 Shipment check, transport, storage................ 7 3.1 Checking shipment........................................ 7 3.2 Transport............................................... 7 3.3 Storage................................................. 7 4 Description.................................... 8 4.1 Construction of the I/O module............................... 8 4.2 Function............................................... 14 4.3 Technical data.......................................... 14 4.3.1 Mechanical data.................................. 14 4.3.2 Electrical data.................................... 14 4.3.3 Ambient conditions................................ 14 5 Installation and removal........................ 15 5.1 Mounting of I/O module................................... 15 5.1.1 Establish connections.............................. 15 5.2 Removing the I/O module.................................. 16 6 Disposal..................................... 17 Content 3

1 About this manual 1.1 Target groups This installation manual is intended for the operator and for technically qualified personnel with experience in leak detection technology and integration of leak detection devices in leak detection systems. In addition, the installation and use of the unit require knowledge of electronic interfaces. 1.2 Other applicable documents Installation manual for mass spectrometer module jiqa54 Interface protocols jira54 1.3 Presentation of information 1.3.1 Warnings Imminent threat of danger resulting in death or severe injuries Dangerous situation potentially resulting in death or severe injuries Dangerous situation resulting in minor injuries Dangerous situation resulting in damage to property or the environment 4 About this manual

1.3.2 Text markings Marking Meaning Requirement for execution of an action Tool or aid for an action Instruction 1, 2, 3,... Several instructions in a fixed order Result of an action SMALL CAPS Designation of the unit or command/term from the menu Information Useful tips and information About this manual 5

2 Safety 2.1 Intended use 2.2 User requirements 2.3 User requirements The I/O module is a device interface between the MSB box of the mass spectrometer module LDS3000 and an external controller, for example. Install, operate and service the unit only in compliance with this manual. Comply with the limits of application (see Chapter 4.3, page 14). Safety conscious operation Operate and install the unit only if it is in perfect working order and as intended, in a safety-conscious manner and fully aware of dangers, in compliance with this manual. Fulfill and ensure compliance with the following regulations: Intended use Generally applicable safety and accident prevention regulations International, national and local standards and guidelines Additional provisions and regulations that are specific to the unit Use only original parts or parts approved by the manufacturer. Keep this manual available at the operating site. Personnel qualifications All work must be performed only by technical specialists who have been trained on the unit. Allow personnel in training to work with the unit only under the supervision of technical specialists. Make sure that the authorized personnel have read and understood this manual and all other applicable documents (see Chapter 1.2, page 4), especially the information on safety, maintenance and repairs, before starting work. Define responsibilities, authorizations and supervision of personnel. Read, observe and follow the information in this manual and the working instructions created by the owner, especially the safety instructions and warnings. Perform all work based on the complete manual. 6 Safety

3 Shipment check, transport, storage 3.1 Checking shipment 3.2 Transport Scope of delivery Article Quantity I/O module 1 Installation manual 1 Check shipment to make sure it is complete. Damage due to unsuitable packaging material Transport in unsuitable packaging material can damage the unit. Transport the unit only in the original packaging material. Keep original packaging material. 3.3 Storage Always store the unit in compliance with the technical data, see Chapter 4.3, page 14. Shipment check, transport, storage 7

4 Description 4.1 Construction of the I/O module Fig: 1 Front view 1 - PLC IN Digital inputs PLC-IN 1 Dyn CAL / Normal Cal PLC/SPS PLC-IN PLC/SPS 2 SNIFF / VAC 0-24V 1 Dyn CAL / Normal Cal 3 STOP 2 SNIFF / VAC 4 ZERO 3 STOP 5 EXT.CAL 6 INT.CAL 7 CLEAR 4 ZERO 5 EXT.CAL 6 INT.CAL 8 9 10 11 PLC-IN-GND 7 CLEAR 8 9 10 11 PLC-IN-GND 0 V 24 V _ 24V-OUT + Fig: 2 Digital inputs Electrical insulation (max. 60 V DC, 25 V AC against GND) Max. permissible input voltage: U = 35 V Active signal: U = 13... 35 V (typically 24 V), I = approx. 7 ma Inactive signal: U < 7 V (typically 0 V), I = 0 ma 8 Description

Connection plug arrangement The digital inputs can be freely configured. Pin Name Factory setting mass spectrometer module 1 PLC-IN 1 Dyn CAL / Normal Cal 2 PLC-IN 2 SNIFF/VAC 3 PLC-IN 3 STOP 4 PLC-IN 4 ZERO 5 PLC-IN 5 EXT.CAL 6 PLC-IN 6 INT.CAL 7 PLC-IN 7 CLEAR 8 PLC-IN 8-9 PLC-IN 9-10 PLC-IN 10-11 PLC-IN-COM COM For other layouts, see installation manual for mass spectrometer module LDS3000. Key-operated switch An external key switch with up to three switching outputs can be connected via three PLC inputs. The key switch can be used to select the access level of the user of the control unit. Key 1 - Operator Key 2 - Supervisor Key 3 - Integrator Example for a suitable key switch: Hop + Schuler, No. 444-05 2- RS232 Connection for RS-232 Electrical insulation (max. 60 V DC, 25 V AC against GND) Connection plug arrangement Pin Name 2 TxD 3 RxD 5 GND A normal RS-232 cable must be used for the connection (1:1 connection, RxD and TxD not crossed, no zero-modem cable). Deactivate RS-232 hardware handshake in RS-232 control program. Description 9

If the hardware handshake cannot be deactivated, then the RS-232 cable can be used as follows: Fig: 3 Connection with RS-232 cable (in case hardware handshake cannot be deactivated) 3 - STATUS Status LED Color Status Meaning Red illuminates Unit not functional or defective Red flashes Not ready for operation, communication to mass spectrometer module is not available Cyan illuminates Ready for operation; communication to mass spectrometer module available Green Flashes quickly Boot loader active, ready for software update Green Flashes slowly Data reception on RS232 Yellow Flashes slowly Data reception on RS485 4 - ANALOG OUT Analog outputs (for logging leakage rate and backing pressure) Electrical insulation (max. 60 V DC, 25 V AC against GND) Voltage range Precision Resolution Load 0...10V ±15 mv offset, additional ±1% from measurement (current output voltage) as linearity error (at 25 C) typ. 2.5 mv >10kΩ Connection plug arrangement The analog outputs can be freely configured. Pin Name Factory setting mass spectrometer module 1 ANALOG-OUT 1 Leak rate mantissa 1... 10 V; linear; in used unit 2 ANALOG-OUT 2 Leak rate exponent 1... 10 V; 0.5 V / decade; step function; 1 V = 1 x 10-12 ; in used unit 3 ANALOG-OUT-GND - For other layouts, see installation manual for mass spectrometer module LDS3000. 10 Description

5 - PLC OUT Digital outputs 8 PLC_OUT_8 7 PLC_OUT_7 6 PLC_OUT_6 5 PLC_OUT_5 4 PLC_OUT_4 3 PLC_OUT_3 2 PLC_OUT_2 1 PLC_OUT_1 FOA75 FOA75 0 PLC_OUT_COM Fig: 4 Digital outputs Electrical insulation (max. 60 V DC, 25 V AC against GND) Max. permissible load per output: U = 30 V, I = 0.75 A Fuses for digital outputs 1... 4 and 5... 8: 2 x 0.75 A Connection plug arrangement The digital outputs can be freely configured. Pin Name Factory setting mass spectrometer module 1 PLC-OUT 1 TRIGGER1 INVERTED 2 PLC-OUT 2 TRIGGER2 INVERTED 3 PLC-OUT 3 TRIGGER3 INVERTED 4 PLC-OUT 4 TRIGGER4 INVERTED 5 PLC-OUT 5 READY 6 PLC-OUT 6 ERROR INVERTED 7 PLC-OUT 7 CAL-REQUEST INVERTED 8 PLC-OUT 8 OPEN 9 PLC-OUT-COM - For other layouts, see installation manual for mass spectrometer module LDS3000. Description 11

6 - FUSE and DIP switch S1, S2 Fuses for digital outputs and DIP switches (under the cover) Fuses for digital outputs 1... 4 and 5... 8: 2 x 0.75 A (Schurter: 7010.9800.xx) DIP switch S1 4321 Factory setting (default value of the interface protocol by MS module/control unit) -000 ASCII protocol -010 LD protocol -011 Binary protocol -101 LDS1000 protocol -110 1 = ON, 0 = OFF, = not used DIP switch S2 4321 Activate boot mode for software update x+ Disable bus terminator 120 Ω for RS-485 1x 1 = ON, + = switching OFF -> ON in operation, = not used, x = no meaning 7 - LD Connection for the data cable to the mass spectrometer module 8 - ANALOG IN Analog input (input voltage range 0 V to 10.8 V) Connection plug arrangement 1 24V supply (output) 2 GND to 24V supply 3 Analog input (0 V to 10.8 V) 4 GND to analog input 12 Description

9 - RS485 Connection for RS-485 A: aktiv B: ohne C: Passiv I/O-Modul I/O-Modul I/O-Modul +5 V +5 V +5 V 1 562 Ω 1 562 Ω 1 562 Ω 2 D+ RS485 3 D- 4 DIP S2-4 120 Ω 2 D+ RS485 3 D- 4 DIP S2-4 120 Ω 2 D+ RS485 3 D- 4 DIP S2-4 120 Ω 5 562 Ω 0 V 5 562 Ω 0 V 5 562 Ω 0 V Fig: 5 RS-485 bus terminator A: Active bus terminator B: No bus terminator C: Passive bus terminator Electrical insulation (max. 60 V DC, 25 V AC against GND) Connection plug arrangement Pin Name 1 Connect pull-up resistor (562 Ω against +5 V) with D+ if necessary 2 D+ 3 D- 4 Connect pull-down (562 Ω against GND) with D- if necessary 5 COM Information The bus terminator integrated in the I/O module (120 Ω) between D+ and D can be disabled via DIP switches S2-4. The BUS address is 1. BUS operation with more than two subscribers is not possible. 10-24V OUT 24V output Connection plug arrangement Pin Name + +24 V - GND Information The I/O module is supplied with voltage by the MS module and requires no separate power supply. The 24V output is not used for voltage supply to the I/O module. The 24V output of the I/O module can be used as an active signal for the PLC inputs and outputs. Description 13

4.2 Function The I/O module is a device interface between the MSB box of the mass spectrometer module LDS3000 and an external controller, for example. The I/O module is equipped with one RS-232 connection one RS-485 connection one analog input two analog outputs ten digital inputs eight digital outputs 4.3 Technical data 4.3.1 Mechanical data Dimensions (W x H x D) Weight 107.6 mm x 89.7 mm x 76.6 mm 300 g 4.3.2 Electrical data Supply voltage 24 V DC 4.3.3 Ambient conditions Permissible ambient temperature (during operation) 10 C... 45 C Permissible storage temperature -20 C... 60 C < +31 C 80% Max. relative humidity +31 C to +40 C decreasing linearly from 80%... 50% > +40 C 50% Type of protection IP 20 Pollution degree II Max. altitude above sea level 2000 m 14 Description

5 Installation and removal 5.1 Mounting of I/O module Fig: 6 Mount bus module on DIN-TS35 top hat rail DIN-TS35 top hat rail 5.1.1 Establish connections 1 Hook unit on top hat rail at bottom. 2 Press unit onto top hat rail at top. Connecting I/O module with MSB box The I/O module communicates via data cable with the mass spectrometer module and is supplied with voltage by the data cable. Data cables from INFICON 1 Connect I/O module (connection LD) via data cable with MSB box (connection I/ OANYBUS). 2 Connect I/O module via desired interfaces with external controller: RS232 (RS-232 interface) RS485 (RS-485 interface) ANALOG IN (analog input) ANALOG OUT (analog outputs) PLC IN (digital inputs) PLC OUT (digital outputs) Installation and removal 15

5.2 Removing the I/O module Fig: 7 Removal of the bus module Flat-tip screwdriver 1 Use the flat-tip screwdriver to pull out the locking device. 2 Remove the I/O module from the top hat rail. 16 Installation and removal

6 Disposal The unit can be disposed of by the user. Information The unit is made of materials that can be reused. By recycling these materials you reduce waste and environmental impact. For disposal, always comply with local and regional environmental and safety regulations. Disposal 17

INFICON GmbH, Bonner Strasse 498, D-50968 Cologne, Germany UNITED STATES TAIWAN JAPAN KOREA SINGAPORE GERMANY FRANCE UNITED KINGDOM HONG KONG Visit our website for contact information and other sales offices worldwide. www.inficon.com Document: jiqc10en1-b (1301)