MGE Galaxy /900 kva

Similar documents
MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

MGE Galaxy /300/400/500 kva Power efficiency for business continuity. schneider-electric.com

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Tel: AC Power for Business-Critical Continuity TM

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

MGE Galaxy 5000 for emergency lighting and power equipment

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Eaton 9EHD Industrial UPS

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

Business continuity made easy

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Schneider Electric Easy UPS 3S

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Schneider Electric Easy UPS 3S

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

MP7. Uninterruptible Power Supply

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

Liebert GXT MT kva

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Modular, scalable, high-efficiency power protection for data centers

Est FlexiPower Maxi UPS FPX Maxi kVA

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

LP 33 Series UPS. Digital Energy. GE Digital Energy

GAMATRONIC, A SolarEdge Division.

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

The Power of Modularity

Modular, scalable, high-efficiency power protection for data centers

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Eaton 9EHD Industrial UPS

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Est FlexiPower Maxi. Modular UPS kw

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

UPS5000-E (25-75 kva) Series

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

MODULAR UPS SYSTEM KVA

Est FlexiPower Ultra UPS FPX Ultra kVA

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

Liebert NXC from 10 to 60kVA

PowerWAVE 8000DPA. (10 20 kva/kw) Parallelable up to 400 kva/kw

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

Newave s approach for protecting mission critical application

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert SX TM. 60kVA to 200kVA UPS Three Phase Input, Three Phase Output

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Powerware P95

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

SMARTONLINE E3 UPS SYSTEMS

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

Power Quality Solutions Eaton 93PR UPS

PowerWAVE 9000DPA. (30-50 kva) Parallelable up to 1.5 MVA

Modular UPS S KVA

Product Brochure Eaton 93PR UPS kw

Critical Power 2017 Catalogue

Intelligent On-Line UPS

TME Modular Series UPS System kva/kw - 208/220 VAC

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

Est ComPower Mini. Compact UPS kva

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Liebert NXC from 10 to 200 kva

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

PowerWAVE 9500DPA. ( kva/kw) Parallelable up to 3 MVA/MW

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

GE Consumer & Industrial. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS

PowerWAVE 8000DPA Modular UPS designed for low and medium power applications

Hitec QPS product range

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

SCALABLE, FAULT TOLERANT, INDUSTRIAL PROTECTION. SOLAHD S5KC UNINTERRUPTIBLE POWER SUPPLIES, 5 20 kva

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density

Transcription:

MGE Galaxy 9000 800/900 kva Data centers are becoming increasingly large, Blade Servers are demanding more power, and there is increasing demand from semi conductors for the digital economy. The MGE Galaxy 9000 range keeps pace with this increasing demand, providing: High availability High power density Flexibility Attractive total cost of ownership (TCO)

Features and Benefits Dedicated system for large data centers and ultra sensitive, high power demand processes The MGE Galaxy 9000 is designed and built to meet the market demand for high kva/kw in a single high density carbon footprint. The MGE Galaxy 9000 is the top choice for Fortune 500 customers seeking the highest in reliability and availability in UPS solutions to meet their critical power protection demands. Providing pure flexibility and high power capabilities, with unique auxiliary equipment such as: paralleling gear up to 4000 kva, and 12 pulse rectifier options that reduces the input THDI to less than 5%. Featuring advanced generator compatibility by an exclusive integrated MGE Galaxy input current limiter design technique. In addition, external bypasses and synchronization boxes maximize the product catalog while maintaining the efficiency and output power quality that you expect with the MGE Galaxy product range. MGE Galaxy 9000 Power quality & availability Low Thdu : < 3% A low Thdi consumption upstream from 4 to 8% Batteries always available High reliability Strongly helps discrimination Rapid and safe maintenance Maintenance Bypass included Easy front access to all parts : quick and safe maintenance, no wrong manipulation Flexibility Different battery types and and backup time Architectures for redundancy and/or power extension with various paralleling modes. Compliant with all type of loads lagging or leading : a lot of kw. Wide choice of integrated options for flexibility towards specific needs Options 12 pulse rectifier Battery cabinets System bypass cabinet Centralized Static Switch cabinet Top entry cabinet Optimized total cost of ownership Low operating costs Low installation costs Typical applications Data centers Financial institutions Industrial Healthcare Petrochemical Utility 2 MGE Galaxy 9000

Dedicated system for large data centers and ultra sensitive, high power demand processes Data centers and telecommunications Easy to upgrade Flexibility for upgrade without any risk is a major requirement for strategic data centers, second only to power availability and quality. Most data centers start with a requirement for a few hundred kva which increases to several MVA as the data center becomes populated. The power uplift is without loss of continuity and planned when required. Various paralleling options of the MGE Galaxy 9000 can provide ideal solution to match this need. in conjunction with Static Transfer Switches (STS), MGE Galaxy 9000 UPSs can supply power to multiple independent circuits for double or triple input power supply units that are regularly used in data centers. Green Data Centers The compact MGE Galaxy 9000 has high efficiency, input harmonic reduction, and improved Power Factor which makes it ideal for organizations committed to Green Data Center design. Meets Data Center TIA 942 and TIER IV requirements* The data center world is becoming more uniform and standardized. MGE offers solutions based on MGE Galaxy 9000 UPSs, MGE Upsilon Static Transfer Switches, and expert design and installation services to meet TIA 942 and the TIER IV requirements defined by the Uptime Institute. Process industry Operation under all conditions Manufacturing conditions often create a very harsh environment for equipment. Dust, damp, vibration, large temperature variations - processes must be able to operate without failure despite such conditions. MGE Galaxy 9000 has been designed to be robust, mechanically as well as electrically, and is ideally suited for providing an uninterruptible power supply. High overload and fault clearing capacity Stable output voltage even during load transients. High ingress protection, strong, reinforced enclosure, dust filters. Compatible with wide range of open lead acid, sealed lead acid, and nickel cadmium type batteries. APC by Schneider Electric design office, and dedicated engineering division, are able to modify standard products or customize them for particular requirements: ruggedization anti-vibration mountings for maritime applications custom paint and markings. MGE Galaxy 9000 Range UPS 800 kva 900 kva Applications Data Center Process Industry Power Factor 0.9 0.8 Short Circuit Capacities 1733 A 1949 A 3 MGE Galaxy 9000

Power quality and availability: assured continuity of service Data communication is part of everyday operation in data centers, telecommunications, and manufacturing processes. In these particularly critical domains, a power cut may cause very serious operating losses and risks for staff and equipment as well as the image of the company. APC by Schneider Electric has designed its high power range to supply high quality power 24 hours a day for all operating conditions and applications. High quality supply to applications The on-line double conversion and variable frequency switching enable the MGE Galaxy 9000 to supply high power quality with: very low output distortion: THDU <3% stable output voltage even during load transients. Advantages: optimum operation of the equipment longer life expectancy protection of capital investment fault tolerant Redundant architectures The Uptime Institute recommends that, from TIER II upwards, equipment should be provided with multiple power sources. For Tier III and IV, redundant power distribution must be provided. Paralleled MGE Galaxy 9000s provide source redundancy. MGE Upsilon Static Transfer Switches provide redundant power distribution. Batteries always available Batteries ensure service continuity. APC by Schneider Electric takes particular care in managing batteries to ensure that they are always ready for demanded duty. DigiBat and Battery Monitoring: for digital battery management DigiBat uses the operating power level, temperature, age, and type of battery parameters to adjust the battery charging voltage for the operating conditions and continuously calculates: the real backup time available the remaining lifetime. DigiBat also: Tests the battery system automatically (at intervals that can be set), without affecting the battery capacity Raises an alarm if the batteries are low. The optional B2000 and Cellwatch battery monitoring systems monitor the battery systems 24 hours a day and provide predictive fault alarms for each battery block: continuous voltage and internal resistance measurement for each block possibility of replacing individual blocks. Advantages: ensures that the battery is available maximizes the lifetime, reduces monitoring and maintenance costs. 4 MGE Galaxy 9000

Flexibility: for upgrading without limits MGE Galaxy 9000 provides high power quality with different types of batteries, architectures, and options and its great integrated paralleling feature allows applications to be upgraded without any risk to the load. AC Bypass Normal Standby Parallel to increase the power with common bypass up to 6 UPSs Easy upgrading: more power, greater redundancy MGE Galaxy 9000 can be installed singly or in parallel with a common bypass and can therefore meet all needs to improve the power availability and increase the power rating as the site develops. MGE Galaxy 9000 UPSs can be synchronized with any other external power source (transformers, generator sets, UPSs, etc.) and can supply power to Static Transfer Switches (STS) to guarantee maximum power availability. Loads AC Bypass Hot standby redundancy Advanced monitoring: wide variety of protocols UPS monitoring is essential for managing an installation and for making decisions if a problem should arise. Local - The optional Vision display combines: functionality (mimic of the whole installation, measurements, trending, statistics) ease of use (large high definition color touch screen). Advantages: rapid learning reduced risk of error, easy to monitor and control for effective, safe operation. Remote - MGE Galaxy 9000 incorporates all the communications facilities that have been developed by APC to: monitor the operation of the UPS and its environment automatically shutdown the operating systems of the servers supported by the UPS supervise a group of UPSs. Using: simple programmable relay contacts J-Bus and Modbus protocols to communicate with a building management system Ethernet 10/100 using HTTPS (Secure Socket Layer) for monitoring via Internet. Advantages: clean shutdown of servers to protect data real-time information about the UPS status can be used with any network management system. Priority load Priority load AC Bypass Load 1 Load Synchronization module Upsilon STS Load 2 AC Bypass Upsilon STS AC Bypass Upsilon STS Integrated parallelling to increase power and redundancy Redundancy using Static Transfer Switches (MGE Upsilon STS) and synchronization module Load 3 5 MGE Galaxy 9000

Minimum total cost of ownership Air-conditioning: kw to be extracted for a 720 kw UPS against efficiency 70 60 Losses (kw) 50 40 30 20 10 0 91% 92% 93% 94% 95% Efficiency High efficiency: reduced running costs At 800 or 900 kva, one of the key criteria of the total cost of ownership is the efficiency of the UPS system. The smallest increase in efficiency can provide significant savings in operating costs. The MGE Galaxy 9000 has variable frequency switching to give an efficiency of up to 95%, even at 50% load. Advantages: Savings in power consumption Reduction in size of air-conditioning and ventilation systems Savings ( ) - Price: 0.06 per kwh Improvement in efficiency 1% 2% 3% 4% 1 year 5 years 1 year 5 years 1 year 5 years 1 year 5 years 1 000 kw 5,256 26,280 10,512 52,560 15,768 78,840 21,024 105,120 1 500 kw 7,884 39,420 15,768 78,840 23,652 118,260 31,536 157,680 2 000 kw 10,512 52,560 21,024 105,120 31,536 157,680 42,048 210,240 Reduction in size of mains input equipment The harmonic filters on the input to the UPSs minimize harmonic currents and improves the power factor: Advantages: Reduces the size of the circuit protection devices on the UPS supply Reduces the cross-section of UPS supply cables Can save up to 20% on the sizing of the electrical infrastructure 6 MGE Galaxy 9000

The most comprehensive range of services Commissioning Schneider Electric Critical Power and Cooling Services can commission all new equipment and provides the necessary support services to meet your specific requirements. Maintenance contracts UPSs must be managed and monitored to keep them in optimum working order. Schneider Electric Critical Power and Cooling Services offers three levels of maintenance contract: ultra: For end-to-end service, all-inclusive for guaranteed peace of mind PREMIER: For effective, basic preventive maintenance SELECT: Pick and mix the services you need Upgradable Installations must remain up-to-date, that is why Schneider Electric Critical Power and Cooling Services provides upgradeable solutions : Technical upgrades Upgrading of battery functions Site audits, studies, and analysis of the UPS environment Harmonic audits Swap-Pac upgrading of the UPS function to anticipate and adapt to changes in your needs, and to provide end of life cycle environmental management Teleservice monitoring services Teleservice continuously monitors the installation 24/7/365 and sends alerts to you and the service center. Powerful diagnostic systems and the largest network of UPS experts worldwide help maintain system availability. 7 MGE Galaxy 9000

Technical Specifications Rated power (kva) 800 900 Active Power (kw) 720 720 Normal AC supply input Input voltage range 323 V to 470 V Normal and backup supplies Separate or Common Frequency 50 or 60 Hz +/- 10% THDI (with filter) < 8 % Input power factor > 0.85 AC bypass input Input voltage range 340 V to 460 V Frequency 50 or 60 Hz +/- 10% Output Output voltage 380/400/415 v +/- 3%* Voltage regulation +/- 1% Frequency 50 or 60 Hz Overload 150% 1 minute, 125% 10 minutes THDU < 3% Batteries Backup time 5-10-15 minutes, others on request Type Sealed / open lead acid, nickel cadmium Overall efficiency Double conversion Up to 95% Environmental conditions Storage temperature -20 C to +45 C dry Operating temperature up to 35 C (1) Noise < 75 dba Operating altitude (without derating) < 1000 m Parallel operation Integrated parallel up to 4 With Static Switch Cubicle up to 6 Standards Construction and safety IEC 62040-1, IEC 60950, EN50091-1 Performance and topology IEC 62040-3, EN50091-3 Design and manufacture ISO 14001, ISO 9001, IEC 60146 EMC immunity IEC 61000-4 EMC emissions IEC 62040-2, EN 50091-2 Class 3 Dimensions and weight (height 2000 mm; depth : 840 mm) UPS Width (mm) 3,600 Weight (kg) 4,100 UPS + 12 Pulse Width (mm) 4,400 Weight (kg) 5,600 *Customizable to address long cable distances when needed. 2012 Schneider Electric. All Rights Reserved. Schneider Electric, APC, MGE, and Galaxy are trademarks owned by Schneider Electric industries SAS or its affiliated companies. All other trademarks are property of their respective owners. e-mail: esupport@apc.com 132 Fairgrounds Road, West Kingston, Ri 02892 u SA 998-1152234