PHABRIX Software release Dolby E analysis Option release

Similar documents
PHABRIX. Dolby Test & Measurement Application Notes. broadcast excellence. Overview. Dolby Metadata Detection. Dolby Metadata Analysis

Rx Series MEDIA GENERATION + ANALYSIS. Faster fault diagnosis, ultra-flexible monitoring

Casper Remote User Guide

Qx Series. IP/12G-SDI, 4K/UHD, HDR/WCG GENERATION, ANALYSIS & MONITORING Advanced, Hybrid IP/SDI Test and Measurement

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

Contents. Rx Series Overview Slide 3 Product Overview Slide 16 Core Toolsets Slide 30 Optional Toolsets Slide 38

GIGABYTE Remote Management Console User s Guide. Version: 1.0

DRAGON CENTER User Guide

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

Video recorders DX Series

DocShuttle Administrator

BitLocker Encryption for non-tpm laptops

BitLocker to Go: Encryption for personal USB

Tutorial NetOp School

Interview Room Management System Administrator Manual

D1.5a Create Access Master Files

PIN Services FTP Configuration, Use and Administration

Creating an Adobe Connect Presentation: Using Your Personal Computer to Record and Publish

ModeChanger

Getting Started with Zoom

How to set up an Amazon Work Profile for Windows 8

See Clean. Installation and Set Up Guide V with Confidence. 3M Clean-Trace Data Trending Software. 3M Food Safety

Windows 7 BYOD on MCSD WiFi

UNIVERSITY OF EXETER BITLOCKER USER GUIDE

You can use the WinSCP program to load or copy (FTP) files from your computer onto the Codd server.

Unit 2: Using Windows 7 Lesson 9

WorldNow Producer. Encoding Video

REVIEWING AND MAINTAINING FILES IN YOUR COURSE S CONTENT COLLECTION

Examplify Student Guide

Ultra XR V3.3 Update XR Ultra XR Update 1

Quick Reference Guide

Logi Ad Hoc Reporting Troubleshooting Authentication Failure. Standard Authentication

BCM 4.0 Personal Call Manager User Guide. BCM 4.0 Business Communications Manager

User Guide. Remote Support Tool

Get comfortable using computers

Not For Sale. Offline Scratch Development. Appendix B. Scratch 1.4

IMPORTANT UPGRADING NOTE

Monitoring systems. Demanding tasks

Download and Install Personal Historian 2 for Mac

WFM8200 and WFM8300 Waveform Monitors Release Notes

User Guide. FTR Manager For more information visit

User pages for RM Portico

AimBetter Database Monitor - Version

Chapter 4 Using the Entry-Master Disk Utilities

DocShuttle Dictator. by Bytescribe, Inc.

DreamTeam Document Manager User Guide

LUXRIOT EVO Installation Guide

Using This Guide. Organization of This Guide

OzSpy DVR Manual. OzSpy AHD DVR User Manual

Setting up PuTTY. CTEC1767 Data Communications & Networking CTEC1863 Operating Systems CTEC1906 Internet Computing

Preface. Fuji Xerox Co., Ltd. Preface. Note

MAXTOR ONETOUCH III MINI EDITION. User s Guide

Website Backend Manual

Setting up PuTTY. Software* Download PuTTY 6/9/18. Microsoft Windows 7 (64-bit) PuTTY 0.70 (64-bit) PuTTYgen 0.70 (64-bit) WinSCP 5.13.

Heritage Woods Digital Manual Windows

RevApp and the Receipts Tracker

Workspace 2.0 Android Content Locker. UBC Workspace 2.0: VMware Content Locker 3.5 for Android. User Guide

CSC 101: Lab #1 Introduction and Setup Due Date: 5:00pm, day after your lab session

User Manual. Contents 1 WELCOME Features Installation Requirements Software Installation Software Operation...

Stratesave 7.0 organized Backup

Qualtrics Survey Guide

Smart Home System Kit

WebEx Conferencing User Guide

RAVENNA Web Interface for device and stream configuration User Guide

Axia xnode Software Package v2.0 Update Instructions & Release Notes

Welcome to Mac OS X, the world s most advanced operating system. This book helps you start using Mac OS X. First install the software, then discover h

Lab - Install Windows 7 or Vista

USER GUIDE FOR STUDENTS ON ACCESSING AND USING THE COMMON ROOM

When the system completes backup, you can see a dialogue box prompting successful backup.

Command Center Software Specification for the M11x platform Version 1.0

Setup Instructions for Upgrading the Windows XP Panasonic CF-19 Toughbook to Windows 7


Sound Manager 2 User Guide

Download and Install RootsMagic for Mac

RealPresence Media Manager

VMware Horizon Client for Windows 10 UWP User Guide. Modified on 21 SEP 2017 VMware Horizon Client for Windows 10 UWP 4.6

Setting up PuTTY. Version Updated for 2015 Fall (with corrections)

Setting up PuTTY. Software* Downoad PuTTY. Download PuTTY Download the putty.zip file. It contains several programs for SSH, SFTP, and SCP.

ESSENTIAL TECHNOLOGY SKILLS AND RESOURCES

MXmeeting User Manual for PC Users

SofTest v11 Exam Instructions

Workspace ONE Content for Android User Guide. VMware Workspace ONE UEM

Setting up Digital VTRs for Dolby E and Dolby Digital Compatibility

Using the Offline Diagnostic Monitor Menu

Instrument Software Update Instructions

Mainconsole. Release Note v7.5.2 (2018/06/12) Release Version v7.5.2

APAD User Guide V1.0

INDS Data Manager for PC Beta 2. Quick Start Guide

AutomaTech Solution Brief. Downloading Software from the GE Customer Center September 2016 SB-MSB-001A

Recording with Panopto for Windows

Management Software AT-S70. User s Guide. CONVERTEON Media Converter Products. Version Rev. B

UPLOADING AN IMAGE TO FACEBOOK AND MAKING IT YOUR PROFILE PICTURE

Configuring a Netgear Router Basic Configuration Steps

What is Skype for Business?

Enterprise Server Edition

Upgrading Echo360 Personal Capture for EchoSystem

AVerMedia. AverDiGi EH5116 PRO. Quick Installation Guide

User Guide. Version 8.0

Installation Guide. Research Computing Team V2.0 RESTRICTED

ipass Open Mobile 2.3.x for Windows Touch Quick Start Guide

Transcription:

PHABRIX Software release 0.10.0062 + Dolby E analysis Option release Dec 16 2010 1

Highlight contents of Software release 0.10.0062 (FREE) 1. New start screen menu display 2. New easy keyboard input of text 3. New enhanced signal analysis features EDH present/missing logged TRS position errors logged ANC error count checksum Active Picture checksum logging Reference status logged 4. New user log in 5. New eye measurement values greyed out if cable length over 50 metres 6. New Generator off warning 7. Temperature protect mode and hardware status menu 8. New FTP Client application Option improvements Enhanced remote control upgraded NEW Dolby E analysis Option released (PHSXOBD) 2

1. New start screen menu The familiar PHABRIX start screen has been updated to display new features available on the Sx platform. Audio groups now show PCM (Pulse code modulation) when audio is present. In addition the presence of Dolby E will be shown as EE only however for complete analysis the full Dolby-E option must be installed. If the unit is an SxE, Eye and Jitter values are shown on the start screen, also available in the eye display screens. With the release of the Dolby E analysis option detailed later, the start screen will display the following extra information: The Dolby, V-Bit and PCM status is now displayed along with basic Dolby E Meta Data. (See Dolby E Option release description at the end of the software release notes) 3

2. New easy keyboard input of text Where input of text is prompted throughout the menu structure, a new easy to use keyboard is activated. Selection of different language keyboards is also available from the right roll bar. 3. New enhanced signal analysis and logging features EDH present/missing logged TRS position errors logged: Any length changes will be flagged ANC error count checksum logged Active Picture checksum logged: Changes flagged Reference status logged New ANC error count logged along with CRC/EDH and Active Picture CRC 4

The logging capabilities in identifying signal faults using the analysis features of the Sx range have been enhanced. This has resulted in several menu additions, particularly in the log Setup selection menu. New logging features on 10.0062 The Events screen with enhanced log/flag reports 5

4. New user log-in Engineering departments can now set user defined names and passwords. With User log-in enabled a log-in screen will be displayed when the Sx is turned ON and a valid user and password is entered. Each user has an encrypted password and permissions which may be set. Using the User Login feature allows the Sx to be protected from operation by unauthorised users and the prompt feature can allow a message to be displayed so that if an Sx unit gets lost or stolen, someone finding it knows where to return it. Add a user by editing a new name in the User Edit box next to the Add User button and then editing a new password. Once the password is 6 characters or longer, the Add User button will become enabled and may be pressed. Make sure that your password is memorable. If all passwords to a unit are forgotten, you can contact Phabrix for an over-ride password. Users with administrator permission may add/delete users. 5. New eye measurement values greyed out if cable length over 50 metres Should the cable length be over 50 metres then the eye measurements will be automatically greyed out. 6

6. New Generator Off warning Several of our manufacturing clients have requested an alert when the generator has been deliberately selected off. In general use the output can be switched off to save power where required. If the user is not familiar with the interface then previously there may be occasions when the unit looked as if it was in fault. 7. Temperature protect mode and hardware status menu A new high temperature protect mode has been implemented on all Sx instruments. Should the temperature increase due to a rare fan failure or operation of the unit in extreme conditions of heat, a short warning will be announced at 60 degrees C. The unit will switch off at 65 degrees C. The Hardware Status display is a diagnostic which can be use to verify the operation of the unit in cases where finger trouble may be responsible for the fault. Should no hardware fault be reported then further investigation of the set-up of the instrument is advised. 7

8. New FTP Client application A new FTP client application is available for download from the website www.phabrix.com > Manuals and software releases. This application simplifies FTP communication with the Sx instruments to specific folders only. This can be useful for downloading screen dumps off the Sx and for file deletion of the Sx s own internal disk by right clicking the mouse for copy, and delete file or delete all functions. Report files created using the Command scripts option can also be downloaded and deleted off the Sx instrument disk. FTP errors are also available to view. There are times when the software zip file may be needed to upgrade a unit offline. Here the zip file can be downloaded directly from the PHABRIX website and copied into the new ftp client on a desktop or laptop connected to the Sx by drag and drop. This will automate the software uncompression and upload the software into the correct file structure within the Sx instrument. After selection of the new software a reboot will be required. 8

Option improvements Enhanced remote control upgraded Following feedback from the many users of the Enhanced Remote control Option, the following changes have been made. Addition of COM_ANYLS_LOG_FORCE_CLEAR commandid for remote control clearing of event log without manual confirmation Added ability to disable Sx the operation buttons and thumb selection buttons when under remote control. Important The following changes have been made to the Remote Control Command name. To correct the naming conventions i.e. COM_GEN_LOG_ACTIVE_PICTURE_CRC_ENABLE Changes to; Option release COM_ANLYS_LOG_ACTIVE_PICTURE_CRC_ENABLE Dolby E analysis Option code PHSXOBD (Basic Dolby E) The new Dolby E option is now available. This option release adds significant Dolby -E audio analysis features to the Sx range. These include metadata analysis, Peak (levels) and logging. Note: De-coded audio is not part of this option. A detailed description of the new features can be found in the manual available for download from www.phabrix.com, >Manuals and software releases The new option allows the display of Dolby-E meta data present in a selected audio stream and determines whether the Dolby-E packet is timed correctly on the SDI video stream. The Dolby- E may be monitored from any of the SDI input embedded audio channel pairs or the AES input. 9 In use the new start menu window displays both the V Bit information and PCM values along with a snapshot of the Dolby E metadata if a Dolby E signal is present.

Using the Signal Information menu > Dolby E will present the full analysis display which forms the major analytical tool for this release. The Dolby-E metadata screen above carries primary information including signal source, Dolby- E guard band timing, CRC errors, program channel and metadata detail. The characters shown in white will only be presented when a Dolby-E signal is introduced into the unit. The peak audio levels included in the Dolby-E meta data packet are displayed on the Analyser>Audio Meters page. Select the appropriate set of meters to display Dolby levels which will follow the selected Dolby-E source. 10

Logging for Dolby E errors, Timing, Common metadata and Program metadata can be controlled form the Logging>Log set-up menu. NOTE: USING A DOLBY DM100 WITH AN Sx instrument. Following beta tests with our customers, the following note must be observed when working with a Dolby DM100. The DM100 generator must be locked to Video Reference 48kHz. This is found on the Setup- I/O Control Gen Clock Source Menu. If this is NOT set, the AES input will not be locked and errors will be detected as the AES input runs in and out of lock. The DM100 AES output needs to be setup to generate Non-Audio AES data or the sample rate converter in the Sx will corrupt the data. Go to Setup-AES3 Output-Audio Mode and set to Non-Audio mode. End 11