Samba Hair System User manual Jefferson Blvd. Culver City, CA 90230, USA Tel: (310) Fax: (310)

Similar documents
BOSSA NOVA TECHNOLOGIES,

New luster formula for the characterization of hair tresses using polarization imaging

New luster formula for the characterization of hair tresses using polarization imaging

Modeling Custom Surface Roughness with LucidShape 2D Scatter Curve BSDF Material

Mu lt i s p e c t r a l

BOLERO. Hair volume/surface measurement fly-away/frizz analysis system. Sebastien BREUGNOT & Robert GEORGE Bossa Nova Technologies

OPERATING INSTRUCTIONS:

Lumascope Startup Guide -- Lumascope 720

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1

CoSMoS Starter Guide 1.4 Hoskins Lab Last Modified 03/03/2017 Chris DeCiantis

Polarization of light

Synoptics Limited reserves the right to make changes without notice both to this publication and to the product that it describes.

Hair. Hair. Edit Panel

CoSMoS Starter Guide 1.6 Hoskins Lab Last Modified 03/30/2017 Chris DeCiantis

University of Minnesota Nano Fabrication Center Standard Operating Procedure

Diffraction. Single-slit diffraction. Diffraction by a circular aperture. Chapter 38. In the forward direction, the intensity is maximal.

Color and Shading. Color. Shapiro and Stockman, Chapter 6. Color and Machine Vision. Color and Perception

A Step-by-step guide to creating a Professional PowerPoint Presentation

QUICK XAFS MANUAL. Andrew Friedman 1 and Elie Horowitz 2 Yeshiva University, New York, NY 10033

Click Install View Touch. Installation starts. Click Next. Click Finish.

Radiance, Irradiance and Reflectance

Experiment 8 Wave Optics

Atomic Force Microscope

TrueChrome Camera Quick Start Guide

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis

Visual Physics - Introductory Lab Lab 0

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

PointWrite User Manual

High spatial resolution measurement of volume holographic gratings

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

Optics: Laser Light Show Student Advanced Version

Gregory Walsh, Ph.D. San Ramon, CA January 25, 2011

Polarization of Light

MobileScan3D. MobileScan3D PlugIn for Geomagic. By Steintek GmbH

DDX-R Quick Start Guide

Nanoparticle Optics: Light Scattering Size Determination of Polystryene Nanospheres by Light Scattering and Mie Theory

2.2. Facilities Requirements

FluxGage. FluxGage. LED Luminaire Measurement System User Manual

TABLE OF CONTENTS PRODUCT DESCRIPTION VISUALIZATION OPTIONS MEASUREMENT OPTIONS SINGLE MEASUREMENT / TIME SERIES BEAM STABILITY POINTING STABILITY

Chapter 15. Light Waves

CONTENTS. Quick Start Guide V1.0

Electromagnetic waves

Wide Guy: Inverted Widefield Microscope

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components...

MantraJet 1100 CD/DVD autoprinter Operator s manual

ezimagex2 User s Guide Version 1.0

Quick Set-up Guide for the Biomedx Configured Olympus CX43

D&S Technical Note 09-2 D&S A Proposed Correction to Reflectance Measurements of Profiled Surfaces. Introduction

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Motic Images Plus 3.0 ML Software. Windows OS User Manual

Ch 22 Inspection Technologies

Flat-Field Mega-Pixel Lens Series

R4 Engine Programming Software

Cross hairs for vertical and horizontal profiles. Profile can be linked to cross hair position, centroid, peak or sum profile can be displayed

Installation Instruction VCPRGBGM05 - rev1.5 RGB Interface Harness modification Navigation Radio

Ioline 300/350HF System

Colony Counting User Manual A D I V I S I O N O F S Y N O P T I C S L T D

e-bridge Color Profile Tool Quick Start Guide

1 Introduction. 2 Mounting the RP3 USB interface

Autodesk Fusion 360: Render. Overview

User's Guide Video Borescope Model BR200

Multimedia Technology CHAPTER 4. Video and Animation

Leica Acquire. User Manual

Chapter 38. Diffraction Patterns and Polarization

Single Slit Diffraction

kena Instruction Manual T-1050

700TSU INSTALLATION MANUAL

AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples

YY Labs Inc. Excellence Through Innovation. CID Camera instant Display/ Optical Beam Profile AnalyzerInstruction V1.

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points

Introduction to Digital Modelling and Animation in Design week 4 Textures

C101-E137 TALK LETTER. Vol. 14

Product information. Hi-Tech Electronics Pte Ltd

Activity P34: Polarization - Verify Malus Law (Light Sensor)

Olympus DeltaVision Microscope Start-Up and Shut-Down Instructions.

Characterizing and Controlling the. Spectral Output of an HDR Display

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories

SECURITY MASTERS ADVANCED MODULE 2

Condensed AFM operating instructions:

SI-100 Digital Microscope. User Manual

4) Finish the spline here. To complete the spline, double click the last point or select the spline tool again.

Karmin2 Stereo Camera

Linescan System Design for Robust Web Inspection

P09052 Molecular Imaging System Upgrade

The Berek Polarization Compensator Model 5540

Complete Barrel Measuring and Inspection System. PS Series. User s manual

Spot Analyzer TiVi80 User Manual User Manual 3.2 Version 3.2 October 2013

TECHNICAL INFORMATION Forensic Video-Based Optical Comparators Catalog Nos. FX10A, FX10AC

Operating Procedure for Horiba Raman Microscope

Measuring range X / Y mm 100 / / /170 Z travel mm 200 / 400** Max. table load kg 20

LEXT 3D Measuring LASER Microscope

F l e x A d a p t o r

4. Refraction. glass, air, Perspex and water.

3 Indexer Installation For PRSalpha Tools

Homework #1. Displays, Image Processing, Affine Transformations, Hierarchical Modeling

Getting Started with ShowcaseChapter1:

How to Measure Wedge. Purpose. Introduction. Tools Needed

SES123 Computer Methods Lab Procedures

All forms of EM waves travel at the speed of light in a vacuum = 3.00 x 10 8 m/s This speed is constant in air as well

COS 116 The Computational Universe Laboratory 10: Computer Graphics

Transcription:

Samba Hair System User manual 11922 Jefferson Blvd. Culver City, CA 90230, USA Tel: (310) 577-8110 Fax: (310) 943-3280 http://www.bossanovatech.com Page 1/32

About This Manual This Manual describes SAMBA Hair System hardware and software. Use this manual as a reference when working with your Samba System. Copyright and Manual Notice Bossa Nova reserves the right to make changes to this manual and to the items described therein without notice. Bossa Nova has taken considerable effort to ensure that the information in this manual is accurate and complete. However, Bossa Nova will not be liable for any technical or editorial errors or omissions made herein or for incidental, special or consequential damages of any nature resulting from the furnishing of this manual, or operation and performance of equipment in connection with this manual. Page 2/32

Content PART 1: Hardware description 1. List of components... 4 2. Connections... 5 3. In-vitro / In-vivo setup... 7 3.1. In-vitro setup... 7 3.2. In-vivo setup... 8 PART 2: Technical background 4. Introduction... 11 4.1. Polarization imaging... 11 4.2. Interaction of light with hair... 13 5. System Geometry... 13 6. Measurement principle... 14 6.2. Step 2: Extraction of the angular profiles... 15 6.3. Step 3: Extraction of the first and second reflections... 17 6.4. Step 4: Characterization of the angular profiles... 18 6.5. Step 4: Computation of Lusters... 20 7. Experimental Results on Hair... 21 7.1. Example on different hair color... 21 PART 3: Software Description 8. Getting Started... 22 9. Software Architecture... 23 10. The Acquisition Menu... 24 10.1. System check... 24 10.2. Acquire a measurement... 25 10.3. In-vitro to in-vivo... 27 10.4. Changing the ROI size... 27 10.5. Performing an auto-exposure... 27 10.6. Opening an existing measurement... 28 11. The Comparison and Export menu... 28 11.1. Saving data from the global listing... 29 11.2. Comparing measurements within the software... 30 11.3. Absolute / Referenced lusters... 31 11.4. Saving data from the displayed listing... 32 Page 3/32

PART 1: Hardware description 1. List of components When unpacking the system, please make sure you have all the following items: SAMBA sensor SAMBA laboratory setup 1 Laptop 2 Ethernet cables (one black, one yellow) 1 power cable 1 mini-cylinder + 2 combs + arm 1 USB dongle 1 USB cable Regular cylinder mount Page 4/32

Combing cylinder mount (optional) 2. Assemble the mini-cylinder arm Arm+knob Screw the arm onto the SAMBA Sensor Page 5/32

The arm should be able to pivot toward the right-hand side of the mount. Page 6/32

3. Connections Look at the back panel of the laboratory setup and connect as follows: Sensor Yellow Ethernet cable Power cord to 110/220VAC Black Ethernet cable Black USB cable To PC To PC (any USB port) 4. In-vitro / In-vivo setup 4.1. In-vitro setup Use the sensor on top of the laboratory setup Make sure you fully close the door before running a measurement. Page 7/32

Position the sensor on top of the laboratory setup using the pins 4.2. In-vivo setup Follow the following steps in the order they are described. Handle the mini-cylinder with caution Page 8/32

Remove the sensor from the laboratory setup Unlock the arm by unscrewing the yellow screw on the side. Rotate the arm in the in-vivo position Lock the arm in position by screwing the yellow screw on the side. On someone with long enough hair, select some hair where the measurement should be done. It is preferable to comb the hair to make sure that the fibers are aligned Page 9/32

You can also use the back of the mini-cylinder to comb the hair The part to be measured is right above the cylinder. Bring the magnetic side gently to clamp the hair on one side of the cylinder Flip the cylinder to position the hair on top of the cylinder groove. Make sure the hair is not messy Gently clamp the other side of the hair Bring the sensor (with the arm mounted) close to the mini-cylinder. The help of someone is highly recommended for this step! Page 10/32

Clamp the cylinder onto the arm mount Once ready, push the button to start the measurement. Hold still until the measurement is done. PART 2: Technical background 5. Introduction 5.1. Polarization imaging When illuminating an object, the light reflected is of different types. If the incident light is linearly polarized, the specular reflection will keep the state of polarization whereas the scattering light from the volume (diffused light) will be unpolarized. Using a polarized illumination coupled to a polarization analysis makes possible the differentiation between the specular and the diffused light. The specular reflection gives information about how glossy or rough the hair is. The diffused light will bring information about the hair color. Page 11/32

SAMBA acquires two states of polarization at video rate. The diffused and specular images can then be calculated as follows: The diffused image Id = 2 x Ic The specular image Isp = Ip Ic where Ip is the light from the first state of polarization and Ic the light from the second state which is 90deg tilted. Note that Id + Isp = Ip + Ic is the image delivered by a conventional camera or seen by the human eye. Examples of polarization images acquired on a white glossy photo paper are shown below. Page 12/32

The specular image only shows the light reflected by the surface of the glossy cylinder, allowing an easy analysis of the paper gloss. In this example, a narrow shine band is extracted. The diffuse image only contains the information coming from the scattered light from the volume. 5.2. Interaction of light with hair Second reflection (chroma) First reflection (shine) Incident light Diffused light Diffused light Hair Cuticle Hair Second reflection (chroma) First reflection (shine) Light scattering in a human hair fiber (Simple model) Diffused light When polarized light illuminated a hair tress, it interacts in such a way that three different types of light are observed: The first reflection (also called shine) is a white polarized surface reflection. It carries the same polarization as the incident light. The second reflection (also called chroma) is a colorful polarized reflection coming from the bottom surface of hair. The diffused light (hair color) consists of unpolarized light coming from the internal scattering. 6. System Geometry The system consists of a polarized illumination, a cylinder and a polarization. The angle between the illumination and the camera axis is around 10 deg. Combining imaging to a cylinder and knowing the system geometry (distances, cylinder diameter) allows to record angular profiles from -45 to +45 deg (angle between the camera and the specular reflection) in one single measurement. Page 13/32

7. Measurement principle 7.1. Step 1: Acquisition of images Once launched, the first step of a measurement is the acquisition of many couples of parallel and crossed images. The set of parallel and crossed images are averaged to obtain one couple of parallel (1) and crossed images (2). By subtracting the averaged crossed image (2) to the averaged parallel image (1), we obtain the averaged specular image (3). The diffused image (4) corresponds to twice the crossed image (2). The sum of the parallel image and the crossed images corresponds to the intensity image (5), which is the image a classical camera would give. Page 14/32

All the images are acquired with a 12-bit depth resolution. The size of the images is 582 (width) by 782 (length) pixels. To each pixel corresponds an intensity value between 0 (black) and 4095 (white). The exposure time is the same during the acquisition of the parallel and crossed images. 7.2. Step 2: Extraction of the angular profiles Page 15/32

Region Of Interest (ROI) Reference Target (Glossy gray tile) Vertical crossed sections of the ROI are averaged (rectangles of ten pixels by 778) to give the angular distributions. The profiles are then normalized by the average level in the reference target. The normalization target consists of a gray gloss tile. This allows to compensate for any drift of the light power. Therefore, the measurements are highly reproducible and stable in time. The profiles are unitless. They can be seen as the reflectance of hair. Specular (3) Averaging of the crossed sections along the ROI width 778 pixels = 90deg Page 16/32

7.3. Step 3: Extraction of the first and second reflections A mathematical algorithm extracts the first (shine) and second (chroma) reflection. Note that only part of the hair tress is measured (width of the ROI) based on the RGB specular profiles. The decomposition algorithm makes the hypothesis that the first reflection is a white reflection since it is external. The algorithm computes an amount of color from the RGB specular profiles. Page 17/32

It then removes this information to the luminance of the specular profiles to obtain the first reflection profile. Finally, this signal is removed from the RGB specular profiles to obtain the RGB profiles of the second reflection. No mathematical fit is used during this process. Complete decomposition of light into shine, chroma and diffused light. 7.4. Step 4: Characterization of the angular profiles All the profiles are characterized by parameters such as the maximum, width and integral values. Parameters given for: SPECULAR PROFILES (Luminance, Red, Green and Blue profiles). Luminance is the average of the three RGB profiles: Page 18/32

- Max: maximum of the profiles - θ 0 (deg) : half width of the peak at Max/e (note: e~2.72) - Integral: mathematical integral (area under the curve) - W visual (deg): this parameter is computed on the specular image and not on the specular profile. W visual is the averaged width of the specular band along the ROI width. When looking at hair, the human eye follows the change of the shine band due to the shape of the object. By measuring W visual on the image rather than on the profile, the result we obtained is more correlated to human perception. Width at Max/2 Max DIFFUSED PROFILES: - Max: maximum of the profiles - Integral: area under the curve 1 st reflection (SHINE) PROFILE: - Max: maximum of the shine peak - W 1/2 (deg) : width of the shine peak at Max/2 - Integral: area under the shine peak - Shift to 0 (deg): angle between the center of the image (0 angle) and the Max of the shine peak 2 nd reflection (CHROMA) PROFILES: - W 1/2 (deg) : width of the chroma at Max/2 - Max: maximum of the chroma profiles - Integral: area under the chroma profiles - Shift to 0 (deg): angle between the center of the image (0 angle) and the Max of the chroma profile - Δ/shine (deg): angle between the max of the shine and the max of the chroma Page 19/32

7.5. Step 4: Computation of Lusters From the characterization of the specular and diffused profiles, we compute different luster formulae. In all the following formulae, S and D are the integral values from the specular and diffused profiles respectively. Reich-Robbins S L RR 100. D. TRI S. L 100.. ref TRI ( S D) 0 Where θ ref corresponds to the θ 0 obtained when measuring on the calibration sample. 0 Stamm (does not take the band width into account) S D L Stamm 100. S Guiolet (does not take the band width into account) S L Guiolet 100. D Bossa Nova Technologies Sin 1 LBNT 100.. ( D S ) W out visual The BNT luster was developed to give more dynamic range and sensitivity on dark samples where other formulae sometimes tend to fail. The formula was adapted to polarization imaging using the W visual parameter instead of Theta0 for the width of the specular peak. The formula works on every hair color. Mathematical algorithm Page 20/32

On light hair, S out is negligible compared to D, so the formula is equivalent to the Reich-Robbins one: Sin 1 LBNT = 100.. D Wvisual On dark hair, D is negligible so the Luster is equivalent to a measurement of contrast between the outside area and the inside area of the peak with the additional influence of the band width W. Sin 1 LBNT = 100.. S W out 8. Experimental Results on Hair 8.1. Example on different hair color visual As the hair becomes brighter (blond), the chroma component becomes more and more important. For very dark hair, the chroma and diffused are negligible whereas on blond hair the chroma and the diffused become more and more important. It is interesting to see that for untreated hair, the amount of shine is roughly the same. This is consistent with the fact that the shine comes from the external reflection. Intensity Black Brown Red Diffused a.u. Angle (deg) Angle (deg) Angle (deg) Blond Bleached Gray Page 21/32

Angle (deg) Angle (deg) Angle (deg) PART 3: Software description 9. Getting Started Locate the SAMBA HAIR Software icon in the desktop of your computer. Allow 10-20 seconds after turning on the system before starting the software If there is a problem with the connections, the following message shows: Page 22/32

If you want to perform measurements, check that all cables are properly plugged and try again. If you think there is a problem deeper, please contact Bossa Nova for assistance. If you want to open and analyze saved measurements, click on Analysis Mode. If everything works fine, the live image will be displayed in the main window as shown in the screen shot below. 10. Software Architecture This software is based on two different windows exchanging information: the Acquisition menu and the Comparison menu & Export menu. These two menus allow the user to easily and quickly capture images, process, compare measurements, export data or open existing measurements. ACQUISITION MENU (main window) Perform a System check Run a new measurement Open existing measurements Change the width of the measurement area Create study COMPARISON AND EXPORT MENU Compare (data, graphs, images) up to 6 measurements on the same window Delete measurements Average measurements Export measurements Page 23/32

11.1. System check 11. The Acquisition Menu It is recommended to perform a system check before running measurements (typically in the morning). It is recommended to allow a 5-minute warm-up time before performing this task. - Set-up the calibration sample (black glossy paper strip provided) on the middle groove of the cylinder so you can see it on the live image. Make sure that the paper strip is sitting flat on the cylinder and that there is no finger prints or dust on it. Remove all other samples. Close door. - Click on Check system in the Setup menu bar. Once completed, the following window will open: If all check points passed, the system is ready to be used. The Camera focus checks the focus of the camera by looking at the width of the shine band on the black glossy paper strip The Camera contrast ratio checks the alignment of the polarizers used in the system The Light Intensity checks the power of the LED bar compared to its initial value. The Alignment checks that the shine band on the black glossy paper is straight and centered at 0 deg (middle of the image). The calibration reports are automatically saved in a folder called SAMBA system checks located by default in the desktop of the computer. By default the name of the file will be date_time. What to do if the one or more check point(s) does not pass? Send the calibration report to info@bossanovatech.com (make sure to include the name of your company and the best way to reach you) or contact your local agent. Page 24/32

11.2. Acquire a measurement The main window is separated in two sub-windows: Acquisition window Data management window To switch between windows, either click on the BOSSA NOVA TECH logo on the top right corner or click on File in the menu bar and select the window ACQUISITION WINDOW Click on the logo to switch back and forth between windows DATA MANAGEMENT WINDOW Page 25/32

All the measurements are saved in a folder named SAMBA DATA located by default in the desktop of the computer. Sub-folder 1 Measurement 1 Study 1 Study 2 Sub-folder 2 Sub-folder 3 Measurement 2 Measurement 3 Study 3 Create or select a study. The study folders are located inside the SAMBA DATA master folder. Create or select a subfolder Enter a name for the measurement All the measurements will be saved in this subfolder. Click on the Run Measurement button to acquire a measurement Once the measurement is performed, the following information can be accessed on the software panel: Page 26/32

All the profiles superimposed, the specular, shine, chroma and diffused RGB profiles separately Specular band geometry Results: analysis of the profiles providing integrals and peak size Lusters: a table of typical luster formulae Sum, diffused and specular images. Measurements are automatically added to the Comparison and Export menu 11.3. In-vitro to in-vivo The software automatically senses when the sensor leaves the laboratory setup. The last value read on the reference tile will be used for the in-vivo measurements until the sensor is positioned onto the laboratory setup again. 11.4. Changing the ROI size The width of the Region of Interest where the measurement is made (yellow rectangle on the live image) can be adjusted to study tresses of different sizes (the default size is 200 pixels). Click on ROI Width in the Setup/ROI menu bar and enter a value between 50 and 375 (full width of the groove correspond to 1 ). The user can chose to set the new ROI size as a default value by clicking on Save ROI to.ini file. 11.5. Performing an auto-exposure When performing a measurement, the software automatically adjust the exposure time to avoid saturated areas in the pictures. Because dark hair will necessitate a greater exposure time than blond hair, the user can perform an auto-exposure before performing a measurement when positioning and observing the hair tresses. Click on the icon auto located at the top right part of the live image to perform an auto-exposure on the sample. Page 27/32

11.6. Opening an existing measurement Select one or multiple measurements in the Data Management window and click on the Open Measurement button. Each measurement opened is automatically added to the Comparison and Export menu. Averaged measurements (ending with _avg) cannot be reopened in the software 12. The Comparison and Export menu Click on the Comparison Export Window button in the Acquisition window. The comparison window opens. Page 28/32

All the measurements added from the Acquisition menu are listed in the Global listing list box (measurement acquired in the live mode or existing measurements that are reopened) 12.1. Saving data from the global listing We recommend to save the data by clicking on the icon Export Global The user must select a location and enter a name for the directory where all the measurement listed in the global list box will be saved. Page 29/32

Example with folder name: blond in the desktop of the computer The folder will contain: A sub-folder containing the images with a TIFF format. They can be used for reports/presentations and can be modified. Text files containing the profiles and numerical data An Excel file gathering all the data from all the measurements. It contains a sheet showing all the results and lusters at a glance, another sheet showing all the profiles superimposed, and one sheet for each measurement. 12.2. Comparing measurements within the software Select a measurement in the global list and transfer it to the displayed images list by using the green arrow. For each measurement added to the Displayed images listing, the following information will be displayed: All numerical data Images Profiles Up to six measurements ONLY can be compared at a time. Page 30/32

Non-normalized images show images with the exposure time they were taken with. For example, a black untreated hair tress might have an exposure time of 50ms after auto exposure. After application of a product increasing the shine, the exposure time after auto exposure can be 25ms for example because the hair tress exhibits more luster and if the camera kept the exposure time of 50ms it would saturate the camera the data would be lost. Therefore, it is not fair to compare images directly on the non-normalized panel if visual assessment must be made after application of a treatment. Normalized images show images that are normalized by the exposure time relatively to the image with the greatest exposure time. This allows to compare images directly on the screen. For both non-normalized and normalized images, sum, specular and diffused images can be visualized. Gloss mapping uses the normalized specular images and adds a color coding to them. The user can adjust the dynamic of the color coding (low gloss = blue to high gloss= red) 12.3. Absolute / Referenced lusters Use the Absolute / Referenced button to display luster formulae in absolute values or in percentage. The reference measurement is the one selected in the Displayed Images list box (all values will be 0% for that measurement since they will be referred to themselves). Page 31/32

12.4. Saving data from the displayed listing Click on the EXPORT Displayed button to export the data listed in the Displayed Images box. Enter a location and a name for the folder where the data will be saved. The folder will contain: A sub-folder containing the images with a TIFF format. They can be used for reports/presentations and can be modified. Text files containing the profiles and numerical data An Excel file gathering all the data from all the measurements. It contains a sheet showing all the results and lusters at a glance, another sheet showing all the profiles superimposed, and one sheet for each measurement. Three jpeg images of Non-normalized images, Normalized image and gloss mapping of the compared measurements. Page 32/32