BAC GLOBAL SURVEYOR Mk

Similar documents
German Cathodic Protection

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Weilekes Elektronik GmbH Am Luftschacht Gelsenkirchen Germany Tel: Fax:

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

Druck DPI 620 advanced modular calibrator

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

FG-7000 Digital Force Gauge Operation Manual

Testing Instruments Manufactured by

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Geotron Model G5 Proton Memory Magnetometer

LOW WEIGHT, SMALL SIZE,

DCT7088 Portable Digital Correlation Transit Time Flowmeter

5000V Digital/Analog Megohmmeter Model 5060

MIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2

5000V Digital/Analog Megohmmeter. Models 5050 & 5060

Introduction. Chapter 2

STAGE INTERCOM KIT 1.1 SPECIFICATION. General: The lower section is a small power amplifier designed to drive headphones or a small 8ohm speaker.

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

Power Products. Factory-approved power sources for Isco Samplers and Flow Meters Batteries AC Power Packs Chargers

WALKING TEST KIT WT5000

THROWMASTER 409 T-1 System Transfer Set

Digital Video Inspection

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

MEASURING AND TESTING INSTRUMENTS

FG-7000L Digital Force Gauge Operation Manual

PRODUCT INSTRUCTIONS MODEL SR-2 SOIL RESISTIVITY METER

Hand-held Fully Featured Eddy Current Flaw Detector ET NDE

Multi-Function Ground Resistance Tester Model 6471

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

New earth resistance and ground resistivity meter - Sonel MRU-30

Actuator Commissioning Tool

KUHLMAN INSTRUMENT COMPANY 5000K WARRANTY

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

HEW.E. High Rate Discharge Tester HEW

PRODUCT INSTRUCTIONS MODEL SR-2 SOIL RESISTIVITY METER

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

General. Function elements. Function selection. Densitometric functions. Settings. Device settings. Help. Maintenance. Options.

innovative technology to keep you a step ahead In-Home Leakage Evaluation System

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

EFE300 / EFE400 EFE300M / EFE400M

D-2 Incorporated. Real-Cond Handheld Fuel Conductivity Product Brochure

EFE300 / EFE400 EFE300M / EFE400M

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

PUE 5 Indicator. Reliability in industrial conditions Complex support of weighing process. Functions. Features

PAT-Cal 2 TECHNICAL MANUAL

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

Portable Appliance Tester KT75 OPERATORS MANUAL

MULTI PARAMETER WATER QUALITY SENSORS

PIPA Gascam Gas Pipe CCTV Inspection System

LED Controls. Lighting Controls. LED Controls

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

The new Clare HAL Series. Keeping electrical products safe. Experts in what we do.

A range of brushless servo drives with optional controllers

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver.

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

9000 SERIES - CONTACTLESS JOYSTICKS ULTRA LOW PROFILE ONE, TWO, THREE AXIS WIDE VARIETY OF HANDLES

Hand-held thermometer Model CTH7000

Differential pressure measuring instrument

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Ultra-Accurate Measurement for Temperature and Voltage

Apollo+ Series. Why buy the new Apollo+ Series? Apollo+ Series Users:

Differential pressure measuring instrument

The customer will see the blue-green florescent display of the TIMEMASTER, which will be showing the minimum amount needed to start the car wash.

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

Adam Equipment. Euro January 2003

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Ultra-Accurate Measurement for Temperature and Voltage

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PIECAL 510B/511B RTD Simulator Operating Instructions

Elastimold Molded Vacuum Recloser - MVR

Hand-Held Thermometer Model CTH 6200

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

TITAN S8. Portable Data Acquisition Logger. Product User Guide

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0]

Series 801 Mighty Mouse Double-Start ACME Thread Plug

Safety. 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring

Innovation in Magnetic Field Measuring Instruments. Grad601. Magnetic Gradiometer System

Conveyor Belt Alignment Switches from IDEM

Differential pressure measuring instrument

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

INSTALLATION INSTRUCTIONS

Smart Interrupter SI220

In North America call toll free: Fax

Sollatek SVS Range Voltage Stabilisers User Manual

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

Measurement Systems Datascan Installation and User Guide

Bulletin 871D Cylinder Position Inductive Style

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

PITE 3926C Battery Data Logger User Manual

ErgoOne Pipettes: Overview

Fully Featured Eddy Current Conductivity Meter ET NDE

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

vlocdm2 Rx & Loc-150Tx Data Sheet V1.6

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

Transcription:

BAC GLOBAL SURVEYOR Mk 10 3.1.1 Conventional pipe to soil potential measurements at existing test posts do not provide an indication of the true pipe to soil potential even a few metres away from the test post. To enable a complete pipe to soil potential profile over the entire length of the pipeline a close interval survey is required with pipe to soil potentials recorded at approximately 1 to 2 metres. Advances in technology have made it practical to carry out close interval surveys on buried structures. It is, however not so easy to do them correctly, with maximum effectiveness, accuracy, and unambiguous data presentation. The BAC Global Surveyor System has been purpose built by cathodic protection engineers who understand the requirements for effective field work and cathodic protection data accuracy. The Surveyor System forms a complete package comprising: Datalogger synchronized to the current interrupters. Synchronised switchers to an accuracy of +/- 4 milliseconds/day Cable dispenser with automatic distance incrementing Special high insulation resistance lightweight cable (re-usable) Specialist data handling software. The surveyor Datalogger has the very highest specification available for field instruments. 1

BAC GLOBAL SURVEYOR Mk 10 Continued.. 3.1.1 Input impedance switchable between 10 and 1000 megohms Common mode rejection: better than +/- 1mV for any dc input (operating range): better than 100 db at 50-60 Hz for 10V ac input Normal mode rejection: better than 60 db at 50-60 Hz for 10V ac input Voltage accuracy 0.1% FS Automatic optimum range selection for best voltage accuracy Four independent channels all synchronous (4 potential) All channels balanced input (No earth leakage problems) Automatically calibrates between each measurement Unique synchronization with switchers to +/- 4 milliseconds/day Unique adjustable delay before readings are measured in each switching period Adjustable length of sample period Adjustable sample frequency Distance is measured and recorded automatically as data is logged Operator code entry for features and geographic data Current measurement facility Memory equivalent to 750 Kb computer storage Full QWERTY keyboard 110 001 0022 Mk 10 Data Logger 1100060006 Dump Cable 145 001 0014 Mk 10 Data Logger Manual 2

GLOBAL SURVEYOR SYSTEM 3.1.2 DATA MANAGEMENT SOFTWARE VERSION 5 MS Windows based data management software for all BAC Global Surveyor Close Interval/DCVG Survey equipment Simple to use MS Windows Compatible Printer Friendly 3

DATA MANAGEMENT SOFTWARE VERSION 5 Continued. 3.1.2 Specially designed software to be compatible with the full range of Global Surveyor equipment enabling downloading, editing, saving and printing of data collected from close interval potential (CIP) and D.C. voltage gradient (DCVG) surveys. The software is compatible with MS Windows 95, 98, NT, 2000 and XP operating systems and requires a minimum computer specification of 300 MHz processor with 32MB of RAM. Being MS Windows based the software will print directly to any suitable printer (colour or black and white) negating the need for costly dedicated plotters. For a FREE 30 day trial copy of the software call or email us. 110 001 0021 Data Management Software V5 145 001 0013 Manual 4

SURVEYOR POWER MODULES 3.1.3 The Mk X Surveyor is powered by interchangeable Power Modules. A low battery warning is provided which allows the operator to replace the module in the field. The power module is recharged using the BAC Surveyor Multi-Purpose Charger. The batteries can be recharged while the Surveyor is in use, or when the Module is disconnected.the Power Module also contains the interface between a computer or printer and the Surveyor, and provides connections for the Distance Measurement Unit and for synchronisation signals. The Mark IX Power Modules are also compatible with the Mark VII Surveyor and are interchangeable with the Mark VII Power Modules. 1100010026 Power Module 1100050005 Battery Charger 5

BAC GLOBAL SURVEYOR BACPAC AND DISTANCE MEASURING UNIT 3.1.4 The carry frame comprising of the Surveyor Bac-Pac, Distance Measurement and Cable Dispenser System, has been specially designed to integrate with the Surveyor Data Logger to provide a comprehensive Data Input and Instrument Interface, thus enabling one man operation. The frame provides a carrier for the Power Module, the Cable Dispense and Distance Measuring Unit together with power cable looms to the Surveyor Data Logger and parallel leads to Copper/Copper Sulphate Reference Cells on extension poles. All data is collected and stored by the Surveyor and processed by computer using BAC Data Management program to provide numerical, graphical and analysis presentation. The BAC Global Surveyor System has been developed as a dedicated Cathodic Protection service. The System is accurate, rapid and of high integrity and compliments existing Cathodic Protection procedures and practices. BAC ENGINEERING SERVICES If required, Survey Teams comprising a Cathodic Protection Specialist are available in order to provide a total survey service to clients. 1100020009* BacPac with Distance Measuring Unit 6

BAC SURVEY WIRE AND REEL 3.1.5 Close interval potential surveys are conducted using the BAC Surveyor and BacPac system. To provide a reliable connection to the pipeline a single core, seven strand stainless steel wire is used. The wire is coated with high density polyethylene which provides a high level of insulation between the BAC Surveyor measuring circuit and the ground. A kit is available to allow field repairs to be made to the insulation if required. For normal operational use, 2km of wire is supplied on a single reel. The wire is connected to a 4mm socket in the reel which connects to a 4mm pin on the Cable Dispense System of the BAC BacPac. Reels can be connected together via a 4mm plug to conduct surveys over 2km in length. The reels and wire are robust and re-usable and when used with the BAC Rewind System provide a simple and cost effective cable recovery system. 1100070008 2Km wire c/w Reel 7

REFERENCE ELECTRODE SURVEY POLES 3.1.6 Specifically designed for rugged environments the BAC Surveyor copper/copper sulphate reference electrodes are fitted with ceramic plugs for superior wetting characteristics and improved contact. The ceramic plugs are available separately, in pointed or flat versions. The reference electrodes are fitted to UPVC poles with ergonomic handles. All test cables are routed inside the poles to minimise tangling and damage 1100040008 Surveyor Poles complete with reference electrodes 8

SURVEY WIRE REWINDER 3.1.7 To facilitate efficient recovery and recycling of the BAC Surveyor wire the unique BAC Rewind System is available. Sturdily built, the rewinder allows the wire to be collected rapidly in the field and so be reused immediately. The rewinder is fitted with a comfortable and durable leather pad, with adjustable straps which allow continued use by the operator. 1100030001 Rewinder Complete with Harness 9

GCU Range of DC Current Interrupters 3.1.8 The BAC GCU Range are solid state current interrupters rated between 10A and 200A DC and are designed for switching from very low to high cathodic protection current allowing testing to be carried out. The controlled output has been specifically designed for use with both low output sacrificial anode systems to higher output impressed current systems. The precision timers have 100 predetermined switching ranges stored in the unit, of which 50 are factory set to the customers requirement, whilst the remaining 50 can be set by the user at site and stored for future use. Up to 60 units maybe synchronised simultaneously from a single BAC Global Surveyor Data Logger. The units maybe used as stand alone or as a Slave unit to another switcher effectively working in tandem. The system uses software controlled frequency synchronisation using crystal oscillators to synchronise the switching cycle of the data loggers and current interrupters. The unit utilises state of the art electronics housed in a rugged IP65 sealed enclosure built to withstand a wide range of field conditions. The new GCU range is also compatible with earlier GCU/R3 models. Technical specification Switching current: GCU10/R1 10A max. GCU15/R4 15A max. GCU25/R1 25A max. GCU50/R1 50A max. GCU100/R1 100A max. Accuracy: 10mS over 24 hours Battery life: 80 hours in stand by mode down to 26 hours switching at 0.1 s On/Off cycle Operating Temperature Range: 10 to + 65 o C!00 Switching ranges: (50 preset, 50 user programmable) Power: 6 Volt Nickel Metal Hydride battery 10

Charging: 9 to 12 Volts at nominal current 30mA 11

GCU Range Continued.. 3.1.8 1100010032 GCU 10/R1 1100010007 GCU 15/R4 1100010010 GCU 25/R1 1100010019 GCU 50/R1 1100060020 GCU 100/R1 1100060021 GCU 200/R1 1100060003 Synchronisation Cable 1100050001 Battery Charger 1450010011 Operation Manual Typical electrical schematic: CATHODIC PROTECTION GCU Interrupter PIPELINE 12