Ethernet Smart Cable

Similar documents
ez80f91 Modular Development Kit

ZCRMZNICE01ZEMG Crimzon In-Circuit Emulator

Z8 Encore! XP/Z8 Encore! Development Kits

ez80190 Development Kit Quick Start Guide

Zilog TCP/IP Software Suite

S3 Flash In-System Programmer

Z8 Encore! XP Family of Microcontrollers Development Kits

Z8 Encore! XP F0822 Series

An Automatic Temperature Control System Using RZK

Quick Start Guide. NP290W Turbo Wireless HomePlug

A Simple Console Application for Z8 Encore! XP MCUs

Getting Started with ESPI Interface Using the Z8 Encore! XP F1680

BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router with 4-port 10/100M Switch Quick Start Guide

Brother HL-5370DW Configuration

Zilog Real-Time Kernel

BiPAC 5200 Series. (802.11g) ADSL2+ Modem/Router. Quick Start Guide

BiPAC 6404VP/VGP. VoIP/(802.11g) Broadband Firewall Router. Quick Start Guide

ZMOTION Detection Module Development Kit

BiPAC 8501/8521. SHDSL.bis (VPN) Firewall Bridge/Router. Quick Start Guide

BIPAC Broadband Firewall Router. Quick Start Guide

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

BIPAC-5100 / 5100W (Wireless) ADSL Router

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

High Resolution Digital Weigh-Scale Design Using Z8 Encore! Microcontrollers

Corinex Communications Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this book.

1 Hardware Installation

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Internet Camera Quick Installation Guide

BiPAC 7402R2. ADSL2+ VPN Firewall Router. Quick Start Guide

Flash Loader Utility for the Z8 Encore! XP MCU

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

EEPROM Emulation with the ez80f91 MCU. Discussion

Longshine Technologie Europe GmbH

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan

Lab IP Addresses and Network Communication

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Z8 Encore! Z8F642 MCU Evaluation Kit

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

BiPAC 7300(G) (802.11g) ADSL2+ Router. Quick Start Guide

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Table of Contents. Keyspan:USB Server - User Manual

PePWave Mesh Connector User Manual

ZyWALL 10W. Internet Security Gateway. Quick Start Guide Version 3.62 December 2003

P964 APR 964 Cable Router with 11g AP Quick Installation Guide VER. 1.0

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

ZN-7100-DE500-G V ac Wireless Access Point Quick Setup Guide

NXT Controller Manual IP Assignment in WAN Environments Application Note

OPERATION MANUAL. MV-410HS Web Browser. Version Rev.2

Set Up a PLL Loop Filter on the ez80f91 MCU

Challenge. Hardware Circuit Details. Solution. Result. Features and Functions. Z8 Encore! MC

Part # Quick-Start Guide. SpeedStream 4200 Modem PPPoE Modem Router

Installation Procedure Windows 2000 with Internet Explorer 5.x & 6.0

MOD5270-LC Quick Start Guide. NetBurner, Inc

Network Communications Controller. Quick Configuration Guide DN

DI-704P Ethernet Broadband Router. Ethernet (Straight Through) Cable. 5V DC Power Adapter

Installation Procedure Windows NT with Netscape 4.x

ProjectorNetTM Adapter Quick Start Guide

Hardware Installation Guide Installation (x3350)

I m InTouch Installation Guide for the DSL/Cable environment with a Linksys router Models: BEFSRU31, BEFSR41 V.2, BEFSR11

Universal Motor Control with Z8 Encore! XP 8-Pin Highly Integrated Microcontroller

GV-IP Decoder Box Plus User s Manual

Gigabit Ethernet Switch. Quick Installation Guide MS400834M

Express Setup. System Requirements. Express Setup CHAPTER

Network Guide NPD EN

Character LCD Interface for ez80acclaim! MCUs

LevelOne Broadband Routers

ZyAIR B-500 Wireless Access Point Quick Installation Guide

Gigaset Router / en / A31008-E105-B / cover_front_router.fm / s Be inspired

SOHO 6 Wireless Installation Procedure Windows XP with Internet Explorer 5.x & 6.0

CHAPTER 7 ADVANCED ADMINISTRATION PC

Interfacing Z8 Encore! XP MCUs with an I 2 C-Based Character LCD

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

Click on Close button to close Network Connection Details. You are back to the Local Area Connection Status window.

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver

Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

ADSL Router Quick Setup Guide

SEI DC-UPS Power Management Package Users Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

Silex SD-320AN-03 Serial Server

APPLICATION NOTE AN0004 CHANGING THE IP ADDRESS ON AN EWSi PORTAL PLUS CONTROLLER WITH WINDOWS 7

Industrial Serial Device Server

Serial to Ethernet Converter

Voice Cable Modem User Manual

OUTDOOR IR NETWORK CAMERA Series

Boot Loader for the Z51F6412 MCU

BiPAC 7300VP/ 7300VGP

S3F8S5A Development Kit

HWg-STE HWg-STE PoE MANUAL

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

User Manual. Unpacking and Setup

Analog Telephone Adapter Setup for Q-SYS Softphone

Figure 1. Power Barrel Connector Requirements

Operating Instructions

Actual product may vary from photo

ADSL Ethernet Router

Reinstalling the Operating System on the Dell PowerVault 745N

SERIAL TO ETHERNET CONVERTER E-P User Manual

Transcription:

User Manual UM020704-0508 Introduction Zilog s Ethernet Smart Cable (ESC), ZENETSC0100ZACG, allows you to connect the Z8 Encore!, Z8 Encore! XP, ZNEO, or ez80acclaim! development board to a Zilog Developer Studio II (ZDS II) host-system using an Ethernet connection. This user manual provides instructions for installing ESC hardware. Instructions are also provided for Ethernet-equipped host PCs that are not network-connected. Once the ESC is connected, proceed with debugging as described in the development kit documentation. Kit Contents For more information on kit contents, refer to Ethernet Smart Cable Packing List (PAK0019). Software and Hardware Requirements The software and hardware requirements include: A host PC with ZDS II v4.10.0 or later for Z8 Encore!, ez80acclaim!, or ZNEO. For ZDS II host system requirements, refer to Development Kit Quick Start Guide. The latest version of ZDS II is available for download at www.zilog.com. Note: If you are using ZDS II ez80acclaim! versions earlier than 4.10.0, see Using ESC on ZDS II ez80acclaim! Versions Earlier than 4.10.0 on page 9. An available 10/100 Mbps Ethernet connection. Supported Target Environments The supported target environments are described in the following table. System Clock Power Supply Current* Development Board Minimum Maximum Minimum Maximum Z8 Encore! 32 khz 20 MHz 2.7 V 3.6 V 2 ma ZNEO 10 khz 20 MHz 2.7 V 3.6 V 2 ma Copyright 2008 by Zilog, Inc. All rights reserved. www.zilog.com

System Clock Power Supply Current* Development Board Minimum Maximum Minimum Maximum ez80acclaim! 5 MHz 50 MHz 3.0 V 3.6 V 2 ma *Add this current for ESC requirement on your target's power supply. Installing the Ethernet Smart Cable The ESC is optimized for use on an Ethernet network in which a dynamic host configuration protocol (DHCP) server assigns IP addresses. The following sections provide instructions for connecting the ESC to a DHCP-based network, or directly to an Ethernet-equipped host PC. The ESC s factory default settings include: DHCP enabled IP address: 192.168.1.50 (will change if DHCP server is available to assign an address) Subnet mask: 255.255.255.0 Gateway: 192.168.1.254 No password required Follow the steps described in the section Changing the Default Settings of the ESC on page 6 to change the cable s factory default settings. Note: When a DHCP server is unavailable, the ESC defaults to using IP address 192.168.1.50. If your network uses static IP addresses on a different subnet, connect the ESC to a standalone PC configured as described in Connecting the ESC Directly to a Host PC below. Connecting the ESC to a DHCP-Based Network You need the following to connect the ESC to a DHCP-based network: An active Ethernet connection, such as from an Ethernet Hub. A standard CAT-5 Ethernet cable. Follow the steps below to connect the ESC: 1. Connect the ESC to an Ethernet connection. 2. Connect the 5 V DC power supply to the ESC power connector. UM020704-0508 Page 2 of 11

The green PWR and RUN LEDs illuminate. The green link LED on the ESC RJ-45 cable illuminates (see Figure 1), indicating a live Ethernet connection. The green activity LED on the ESC RJ-45 connector flickers, indicating network activity. DBG Connector Ethernet Connector PWR LED RUN LED 5 VDC Power In Activity LED Link LED Figure 1. Ethernet Smart Cable, Front View and Rear View 3. Start ZDS II. 4. Open one of the projects listed in the samples directory of your ZDS II installation. 5. Select Project Settings. The Project Settings window appears. 6. Select the Debugger tab. 7. In the Debug Tool drop-down menu, select EthernetSmartCable. 8. Click the Setup button. Your ESC will be listed in the Smart Cables Available list. Check the box for your ESC, then click the OK button. Note: If you have more than one ESC, you can uniquely identify them by comparing the MAC address listed in the Smart Cables Available list with the label on the bottom of the ESC. 9. Click the OK button in the Project Settings window. Your project is now configured to run with the newly installed ESC. Now connect the target board to the ESC as described in Connecting to the Target Board on page 9. UM020704-0508 Page 3 of 11

Connecting the ESC Directly to a Host PC When using a host PC that is not network-connected, configure the PC as follows to connect it to the ESC. Note: The following instructions are for the MS Windows XP platform. If your Windows operating system is different, refer to MS Windows OS online help for details. Follow the steps below to connect the ESC to a Host PC: 1. Power on your host PC before proceeding. 2. Use the Ethernet crossover cable supplied with the ESC to connect the ESC to the host PC s Ethernet port. 3. Connect the 5 V DC power supply to the ESC power connector. The green PWR and RUN LEDs illuminate. The green link LED on the ESC RJ-45 cable (see Figure 1 on page 3) illuminates, indicating a live Ethernet connection. The green activity LED on the ESC RJ-45 connector flickers, indicating network activity. 4. On the host PC, open the Windows Control Panel and double-click the Network and Internet Connections icon. The Network Connections dialog box appears (see Figure 2). Figure 2. The Network Dialog UM020704-0508 Page 4 of 11

5. In the panel labeled LAN or High-Speed Internet, double-click the Local Area Connection icon. The Local Area Connection Status dialog box appears, see Figure 3. Figure 3. The Local Area Connection Status Dialog 6. In the Local Area Connection Status dialog box, click the Properties button. The Local Area Connection Properties dialog box appears, as displayed in Figure 4. Figure 4. The Local Area Connection Properties Dialog UM020704-0508 Page 5 of 11

7. In the panel labeled This connection uses the following items:, select the Internet Protocol (TCP/IP) item to highlight it, and click the Properties button (see Figure 4 for an example). The Internet Protocol (TCP/IP) Properties dialog box appears, as displayed in Figure 5. Figure 5. The Internet Protocol Properties Dialog 8. Enter an IP address of 192.168.1.21 and a subnet mask of 255.255.255.0. These values place the PC on the same network as the ESC, and do not conflict with the IP address of the ESC. 9. Click OK and restart the PC. The PC is now ready to communicate with ESC via the ZDS II software. The default IP address of the ESC unit is 192.168.1.50. Changing the Default Settings of the ESC The ESC is equipped with a web interface that allows you to change its default settings. To access the ESC web interface, you must know the cable s IP address, which can be obtained from ZDS II in the ZDS II Project Settings window (see step 5 through step 9 on page 3). UM020704-0508 Page 6 of 11

Follow the steps below to change the ESC default settings: 1. Obtain the ESC IP address. 2. Open your web browser to the IP address located in step 1. The ESC home web page appears (see Figure 6). The Settings tab provides access to ESC network settings. The Password tab (see Figure 7 on page 8) allows you to set a password for ESC access. Figure 6. Ethernet Smart Cable Home Web Page UM020704-0508 Page 7 of 11

Figure 7. Ethernet Smart Cable Password Web Page 3. Once the configuration in the Settings tab are changed, click the Submit button. A message acknowledging that changes have been made appears beneath the web page. 4. To make the changes permanent, reboot the ESC. To do so, press the Reboot button. The ESC will reboot. If you have changed the cable s IP address, redirect the web browser to point to the new IP address. If the IP address is left as it was, the ESC home web page will appear again, displaying the changes you made. Restoring the ESC Factory Settings Follow the steps below to restore the ESC factory settings: 1. Locate the reset switch access hole in the side of the ESC housing. 2. Using a straightened paper clip, press and hold the reset switch for six seconds. The Run LED will extinguish while the switch is pressed, and will illuminate again after factory settings are restored. UM020704-0508 Page 8 of 11

Connecting to the Target Board Attach one end of the six-conductor ribbon cable to the Smart Cable six-pin DBG connector (see Figure 1 on page 3). Attach the free end of the ribbon cable to the connector on the target board. Ensure that pin 1 on the ribbon cable (indicated by the dark stripe) is aligned with pin 1 on the target connector. For more information on connecting the ESC to your target board, refer to either ez80acclaim! Design for Debug Technical Note (TN0035) or Z8 Encore! Design for Debug Technical Note (TN0036). Troubleshooting Tips If a hardware failure is suspected, contact a local Zilog representative for assistance. Before submitting a problem report to Zilog Customer Support, follow the instructions below: ZDS II Cannot See the ESC If ZDS II cannot see the ESC: Remove power from the ESC, wait five seconds, then reapply power. Refresh the list of available smart cables. The ESC must now appear. Verify that the Ethernet cable you are using is the right type. (If you are connecting the ESC directly to a PC, you must use a crossover cable. Do not use a crossover cable to connect the ESC to a Hub or standard Ethernet connection.) Verify that UDP port 3000 is open in your local firewall. The ZDS II software uses UDP port 3000 to search for ESC IP addresses and requires access to that port through your local firewall. Once the port is open, ZDS II should then be able to identify the IP address assigned to the ESC by your DHCP server. Using ESC on ZDS II ez80acclaim! Versions Earlier than 4.10.0 Follow the procedure below to obtain the IP address of the ESC when configured for DHCP: 1. Download the ESC Scan utility installation file from http://www.zilog.com/software/ zds2.asp under the miscellaneous section. 2. Run the installation file to install it to your local drive. 3. Run the escscan.exe application file from the installation directory. You will see the following example screenshot (see Figure 8). UM020704-0508 Page 9 of 11

Figure 8. escscan.exe Application Screenshot 4. Note the IP Address. If you have several ESC connected to the network, the IP address will be shown for each particular ESC s MAC address. 5. Press any key to exit the utility. 6. The IP Address is the one you have to use when configuring the ZDS II Project Settings Debugger Configure ZPAK II IP Address. For more information on this utility, refer to readme.txt document. UM020704-0508 Page 10 of 11

Warning: DO NOT USE IN LIFE SUPPORT LIFE SUPPORT POLICY ZILOG'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF ZILOG CORPORATION. As used herein Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Document Disclaimer 2008 by Zilog, Inc. All rights reserved. Information in this publication concerning the devices, applications, or technology described is intended to suggest possible uses and may be superseded. ZILOG, INC. DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION, DEVICES, OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZILOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION, DEVICES, OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering. Z8, Z8 Encore!, Z8 Encore! XP, ZNEO, and ez80acclaim! are trademarks or registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners. UM020704-0508 Page 11 of 11