True RMS Ampstik Plus Slip-on Ammeters

Similar documents
Recording Ammeter Amcorder

Operators Manual. Recording Ammeter Amcorder UG. SensorLink

Ohmstik PLUS Multiple Reading Live-Line Micro Ohm me ter

Global Water Instrumentation, Inc.

PCM-7140 Pulsed Current Source Operation Manual

Global Water Instrumentation, Inc.

Electrostatic Fieldmeter Model 775

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

FA-2448 SIX POSITION Filter Wheel

User s Guide. 600A AC Clamp Meter. Model 38387

PIM-Mini Pulsed Current Source Operation Manual

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

MAXIMA+ Series Rotary Level Indicator

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

DIGITAL VOLTAGE INDICATOR

User's Guide. Extech AM A AC Analog Clamp Meter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

MAXIMA + Series ROTARY LEVEL CONTROL

The Solid-State Decoupler (SSD)

AirPro Surveyor 2 Manual

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

1875 Smart Calibrator. Instruction Manual

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Push-Pull and E-Stop Switches. Datasheet

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

V-9908 MESSAGE/PAGE PANEL

V-9939B MICROPHONE ADAPTER

Global Water globalw.com. Global Water. Instrumentation, Inc.

IVC-222HPII Precision Voltage/Current Calibrator

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

MTS-2000 USER S MANUAL

Operating Manual RISH DPM Hz

W Warning To avoid electrical shock, remove test leads and any input signals from the Model 707 Loop Calibrator before opening the case.

Description. Green. Red. Orange

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

SA SERIES Arlingate Lane, Columbus, Ohio (614)

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

CMSA-100 Manual. Cinema Media Server Automation

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Automated Tuner System Power Distribution Hub

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operating Instructions

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Series STA DIGITAL TORQUE TOOL TESTERS. User s Guide

TETRIS 2500 High Impedance Active Probe. Instruction Manual

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

MTP INSTRUCTION MANUAL

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

VELOCICALC Air Velocity Meter

DP-222Q Color Video Door Phone Manual

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Model 8702 DP-CALC Micromanometer

ArmorPoint I/O Field Potential Distributor, Series A

EPS Power Supply

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Enhanced Mini-Chansim Model VCS-232

Broadband Automatic Disconnect Switch. User Manual

I/O SIGNAL CONDITIONER

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

iconverter 2-Module Power Chassis

Digital Overhead Stirrer

MAXIMA + Series ROTARY LEVEL CONTROL

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

MICRO SWITCH Military-Grade Toggle Switches. TL Series. Datasheet

Installation Instructions

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

AC4G-D User s Manual

PSA200 User s Manual

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Limit Switch Box YT-870/875 SERIES

Operating Instructions

Operating Instructions

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

rht+ RHTPlus CalComm Calibration Unit with Analogue Outputs

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

MICRO SWITCH Military-Grade Toggle Switches TL Series Issue 4. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Zonit μats TM Users Guide μats1-lv Version 1.2

700 Series 200 Amp Clamp Meters

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

SLM Series Slot Sensors

DP-222Q Color Video Door Phone Manual

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

LED W RGBA User Manual

Installation, Operation & Maintenance Instructions / Technical Document

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Transcription:

Operators Manual True RMS Ampstik Plus Slip-on Ammeters SensorLink

Operators Manual True RMS Ampstik Plus Slip-on Ammeters Available Stock Codes: 8-020 XT PLUS 50HZ 8-020 XT PLUS 60HZ 8-020 XT PLUS EURO 8-020 XT PLUS FRG 8-022 PLUS-50HZ 8-022 PLUS-60HZ 8-022 PLUS-EURO 8-024 PLUS-50HZ 8-024 PLUS-60HZ 8-024 PLUS-EURO Table of Contents Page Specifications 2 Safety Warnings 3 Operating Instructions 4-5 Startup Test 4 RUN & HOLD Mode 4 Viewing the Measurement 5 Power Off 5 Automatic Backlight 6 Battery Replacement 7 Cleaning 7 High Voltage Operation 7 Troubleshooting 8 Warranty 10 Quality Assurance Back Cover

Overview The True RMS Ampstik Plus has been developed specifically for mea sure ment of AC cur rent in the electrical utility industry. The True RMS feature allows accurate mea sure ment of current even when the nominal waveform is distorted or when harmonics are present. This may be the case with Y connected transformer neutral leads and dis tri bu tion to many in dus tri al customers using SCR con trol lers and other switching de vic es. This in stru ment can be used re mote ly with any hot stick and universal chuck adapter. The in stru ment has no moving parts and does not require clamping onto the wire. The molded housing is water resistant and will withstand high physical impact. The following specifications apply: SPECIFICATIONS Model Number 8-020 XT Plus 8-022 Plus 8-024 Plus Range of Operation Voltage Phase to Phase 0-500kV 0-69kV 0-400kV Current 1-5000A 1-2000A 1-2000A Sensor Opening Standard Wide Jaw Wide Jaw Opening Width 2.5 in 6.35 cm 3.86 in 9.8 cm 3.86 in 9.8 cm Type of Reading Four readings Four readings Four readings Resolution Amps 1-99.9A 0.1A 0.1A 0.1A Amps 100-1999A 1A 1A 1A Amps 2000-5000 0.01kA N/A N/A Weight 2.15 lbs, 0.97 kg 3.8 lbs, 1.76 kg 3.8 lbs, 1.76 kg Accuracy ± 1%, ± 2 Counts Frequency Actual frequency indicated on unit 50 Hz Calibrated 47 to 53 Hz 60 Hz Calibrated 57 to 63 Hz Mechanical Operating Temperature -22 to +140 F, -30 to +60 C Lithium battery required for temperatures below -4 F (-20 C) Display 3.5 Digit display Backlight Automatic ambient light sensor Housing Shock & water resistant molded urethane Hotstick Mounting Universal chuck adapter (hotstick not included) Battery 9V Alkaline or Lithium EEC Standards Successfully passed international tests indicated by CE Page 2

Safety Information The True RMS Ampstik Plus is designed for use with a suitable universal hot stick. All precautions appropriate for the line voltage should be taken. The hot stick should be considered the sole voltage isolation device. For safety purposes the face plate, battery cover, chuck, and entire Ampstik Plus should be considered to be at the same potential. Putting the face plate, battery cover, chuck, or other parts of the Ampstik Plus within the air gap of adjacent phases or ground could cause a phase to phase or phase to ground fault. WARNING! Do not force the arms of the Ampstik Plus Page 3

Operating Instructions The True RMS Ampstik Plus is controlled by a single push button switch located on the front panel. Operation is as follows: POWER ON - Press and release the control switch to turn on the instrument. Startup Test The Ampstik Plus conducts a startup test to verify the sensors and circuitry is functioning correctly. The following screens will display during the test: If the test detects a failure, the display will show FAIL and a corresponding code. See page eight for the failure code chart. 1 - - - FAIL If the test determines the unit is functioning properly, it will move to normal mode and is ready to take the first measurement. The display will show: 0.0 RUN Option - The reading continuously changes as the current changes. The unit is immediately in the RUN mode after powering on. To place the instrument into the RUN mode from a different mode, press and hold the control switch and scroll to the option RUN, then release the control switch to engage the option. To take measurements with the True RMS Ampstik Plus in the RUN mode, place the conductor between the two arms and observe the display. For maximum accuracy, be sure that the conductor is below the notches on the arms. If the conductor cannot be placed below the notches, readings can be taken but the accuracy may be lessened. HOLD Option - Stores up to Four readings Press and hold the control switch to scroll to the HLD option, and release the control switch to engage the option. The True RMS Ampstik Plus is now in the sample and hold mode, indicated by the word HOLD ap pear ing on the display. As shown below, nothing else will display until a measurement is held: HOLD To take the first of the four measurements, place the conductor between the legs of the instrument. Remove the Ampstik Plus from the conductor. Repeat this Page 4

process to aquire up to three more readings. It holds the readings and displays them one at a time as follows: 1 HOLD 1 3 2 4 HOLD 65.5 VIEWING THE STORED MEASUREMENT The number of the reading that is being viewed will flash. 72.0 To scroll to the next reading, press and release the control switch. Repeat this to scroll through all readings. Note: The display resolution changes on the following ranges: XX.X XXXX X.XX 0-99.9Amps 0.1Amp resolution 100 to 1999 Amps 1Amp resolution 2000 to 5000 Amps 2.00 kamps 10 Amp resolution (2 decimal places indicates kamp range) CLEARING THE DISPLAY - Clearing the stored measurements You must first go to the DEL option to clear the stored readings before taking further readings. Press and hold the control switch, the DEL option will appear: release the control switch. All of the data has been cleared. The data will also clear when either the OFF or RUN modes are selected. NOTE: If the instrument has four readings in its memory and another attempt is made to take a reading, the display will show: - - - POWER OFF - Turning the instrument OFF Press and hold the control switch to scroll to the OFF option. Release the control switch. The True RMS Ampstik Plus will turn itself off automatically after several minutes of inactivity. Page 5

Backlight The Backlight on the Ampstik Plus is designed to automatically power on when the ambient light is low. This helps users view the display in low-light situations. The light sensor is located on the front of the unit. It's location is indicated with the light icon on the front panel next to the switch. The backlight will continue to power on automatically until the user manually changes the settings. POWER OFF BACKLIGHT - Manually power off the backlight Press the control switch until the following screen appears: After releasing the switch, the display will momentarily show: The backlight will stay off until the user manually powers it back on. POWER ON BACKLIGHT - Manually power on the backlight Press the control switch until the following screen appears: After releasing the switch, the display will momentarily show: The backlight will now automatically power on when light is diminished or until the user manually powers it back off. The user may see some flicker with the backlight if the backlight is on when under artificial lighting. This is normal. Page 6

Battery Replacement When the LO BAT indication shows on the display, the battery should be re placed. The unit will continue to operate for a few hours. The Ampstik is powered by a single 9V battery. To re place the battery, remove the four screws on the battery cover at the rear of the unit. Carefully insert a screwdriver blade in the notch and pry the cover out, being careful not to damage the cover seal. Pull the bat tery out of the com part ment and sep a rate the battery from the battery connector. To avoid breaking the battery leads do not pull on the battery only. Install a fresh battery and reinsert the battery in its com part ment. Reinstall the cover by gently press ing it into place while pulling out on the edges of the com part ment, and reinstall the four cover screws. Take care to avoid over tight en ing the screws. Always reuse the screws provided and do not damage or lose the o-ring seal on each screw. Cleaning The Ampstik can be cleaned by wiping with a small amount of alcohol on a rag. High Voltage Operation This instrument is designed to operate in high voltage fields. How ev er, difficulty may be experienced when excessive corona to the instrument occurs. The unit may ex pe ri ence over range and require power to be cycled or may lose a reading when in the sample and hold mode. Page 7

Troubleshooting the Ampstik Plus Unit will not power on Verify there is a fresh 9V battery in the unit. Verifty the battery connectors have not been disconnected from the molded housing. Backlight Flicker Due to the refresh rate of the light, some users may see flicker if the backlight is on when under artificial lighting. This is normal. Fail Codes FAIL CODE "1": Break to the main current sensor FAIL CODE "2": Break to a current sensor component FAIL CODE "3": Circuit failure FAIL CODE "4": Circuit failure The above fail codes may also trigger due to dirty pin connections causing errors in readings between the main board and molded housing assembly. The unit will not enter into measurement mode if the self-test has any of the above failures. The unit will need to be returned to SensorLink for repair evaluation. Repair SensorLink Service Department Please contact SensorLink directly for the return process of product for evaluation, repair, calibration, and verification. Contact details: SensorLink Corporation Tel: (360)595-1000 Fax: (360)595-1001 E-mail: info@sensorlink.com Page 8

Page 9

SensorLink Corporation Warranty SensorLink warrants each instrument it man u fac tures to be free from defects in materials and workmanship under normal use and service for the period of one year after date of shipment. Within this period, SensorLink agrees to repair or replace, at SensorLink s option, any instrument that fails to perform as specified. This Warranty shall not apply to any instrument that has been: 1 Repaired, worked on, or altered, including removal of the front panel, by persons un au tho rized by SensorLink in such a manner as to injure, in SensorLink s sole judgment, the per for mance, sta bil i ty, or reliability of the instrument; 2 Sub ject ed to misuse, negligence, or accident; or 3 Connected, installed, adjusted, or used otherwise than in ac cor dance with the instructions furnished by SensorLink. This Warranty is in lieu of any other warranty, expressed or implied. SensorLink reserves the right to make any changes in the design or construction of its in stru ments at any time, without incurring any obligation to make any change what ev er in units previously de liv ered. If a failure occurs, contact the manufacturer for a Return Au tho ri za tion and instructions for return shipment. This warranty con sti tutes the full understanding of the man u fac tur er and buyer, and no terms, conditions, understanding, or agree ment purporting to modify or vary the terms hereof shall be binding unless here af ter made in writing and signed by an authorized official of SensorLink. Page 10

Quality Assurance Certification True RMS Ammeter Models 8-020 XT Plus, 8-022 Plus, 8-024 Plus SensorLink certifies that its calibration measurements are trace able to the National Institute of Standards and Tech nol o gy (NIST), to the extent allowed by the Institute's cal i bra tion fa cil i ty, and to the calibration facilities of other In ter na tion al Standards Or ga ni za tion members. This document certifies the following True RMS Ammeter was tested at the SensorLink High Voltage Laboratory, Ferndale, WA, USA to the appropriate standard and comply with the requirements of that standard. Serial Numbers Model Numbers I hereby certify that the True RMS Ammeter listed above has passed all tests defined in the SensorLink standard. I also certify that I have reviewed the standard and test procedure and that they are sufficient in determining compliance with the standard. Signed Date Form No: SALE-Manual Template AMPSTIK-006 REV: V01 Date: 11/19/2013 Manual Stock Code No: M050-010-002 SensorLink Corporation 1360 Stonegate Way Ferndale, WA 98248 USA phone: 360/595.1000 fax: 360/595.1001 www.sensorlink.com