Series CTA CAP TORQUE TESTERS. User s Guide

Similar documents
User s Guide. Series CT CLOSURE TORQUE TESTER. User s Guide

Series STA DIGITAL TORQUE TOOL TESTERS. User s Guide

Series ST. User s Guide DIGITAL TORQUE TOOL TESTERS. .com. Series ST Torque Tool Testers. User s Guide

Digital Controllers Series DC MODEL DC4010 / ESMH-DC MODEL DC4020 / ESM-DC MODEL DC4030 / TSFM500-DC MODEL DC4040 / TSTM-DC.

SMART FORCE AND TORQUE SENSORS. User s Guide

MESURgauge Software. User s Guide

SMART FORCE AND TORQUE SENSORS. User s Guide

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

Premium Digital Force Gauges

User s Guide. Series 2 DIGITAL FORCE GAUGES

HHTQ35 Digital Torque Gauges

User s Guide. Model PTA PLUG & TEST TM ADAPTER

Model 3i DIGITAL FORCE / TORQUE INDICATOR. User s Guide

Digital Torque Tester

Universal Force / Torque Gauge

MPT-250A SPECIFICATIONS AND OPERATING INSTRUCTIONS

NOTES TABLE OF CONTENTS

DTT Series Digital Torque Testers User Manual

Series ST-H01-25 DIGITAL CAP TORQUE TESTERS. User s Guide

Digital Torque Tester/Wrench

User s Guide. Series 3 DIGITAL FORCE GAUGES

DTT-L Series Digital Torque Testers User Manual

PC 150. Digital Bench Scale. Operation Manual

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

FA-2448 SIX POSITION Filter Wheel

Digital Measurement Metrology, Inc PRECISION IS OUR VISION

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide

Digital Torque Screwdriver

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

Digital Force Gauge INSTRUCTION MANUAL. Model: DS2

Digital Torque Wrenches

TTC Series Torque Tool Tester Operation Manual

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

TNP Digital Torque Meter Operation Manual

Force Test Stands Series ES. User s Guide

Model 8702 DP-CALC Micromanometer

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10

User s Guide. Series TT02 TORQUE TOOL TESTERS

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

AUTOMATION. Operator s Manual PG10. Full Access. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications

Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25

3 Input Multiplexer Operation Manual

VELOCICALC Air Velocity Meter

Exposure Monitoring. Model 8560 INSPECTAIR CO 2. Meter. Operation and Service Manual , Revision B June 2006

INSTRUCTION MANUAL. Models: H100 Light Meter

Series E ERGONOMICS FORCE GAUGES. User s Guide

MESURgauge Software. User s Guide

FNet Repeater Installation & Operator s Instruction Manual

PC-150. DIGITAL BENCH SCALE Setup / Operation Manual

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

AirPro Surveyor 2 Manual

AWS-QC Torque Tester

Biesemeyer Fence Kit Installation Instructions:

CONTENTS CONTENTS AWS-4050 Guide

AWS-3000 Torque Display

PRO Owner's Manual

Card Encoder. PC Software. User Manual Software OPW Fuel Management Systems Manual No. M Rev 2

CA-A480-A Elevator Controller. Reference & Installation Manual

Miniature Overhead Stirrer

PIM-Mini Pulsed Current Source Operation Manual

ELECTRONIC TORQUE METER ETM OPERATION INSTRUCTION

PCM-7140 Pulsed Current Source Operation Manual

INDEX WARRANTY CALIBRATION Checking Calibration 7.20 Field Calibration Adjustment 7.30 Special Calibraton

DFS Series User s Manual (5N-1000N Capacity)

DI-ACRO #24 HAND SHEAR INSTRUCTION MANUAL

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

COBEX RECORDERS, INC.

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

Sonic Ruptor 400. User Manual

P F

TH ST N OAK PARK HEIGHTS, MN P F

Digital Bench Scale. Revision 8.93 August 12, 1993

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

FG-7000 Digital Force Gauge Operation Manual

PRO 360. Owner's Manual

Shop Fox Fence Kit Installation Instructions:

BCD Interface for the 520 Indicator. Installation and Configuration Manual

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

MTMDP Torque Display With Multiple Internal Transducers

TABLE OF CONTENTS WARRANTY

FG-3000 Digital Force Gauge Operation Manual

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

Operations Manual EcoSense ph100

Analog Interface Unit Operation Manual

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

Adjustable Timing Control PN 8680

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

DICKSON MP100 DICKSON. Operation Manual. Applications. Product. Specifications. Product. Contents:

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

SA SERIES Arlingate Lane, Columbus, Ohio (614)

Operating instructions METTLER TOLEDO BD balances

TABLE OF CONTENTS. 9.0 Warranty

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

Model TA4 Torque Analyzer

FG-7000L Digital Force Gauge Operation Manual

Torque Meter. Instruction Manual

Pulse LED Instruction Guide

Transcription:

Series CTA CAP TORQUE TESTERS User s Guide

Series CTA Cap Torque Testers Thank you! Thank you for purchasing a Mark-10 Series CTA Cap Torque Tester. We are confident that you will get many years of service from this product. The CTA can be used to test cap torque for a number of different closure shapes and sizes, along with other types of samples. To maintain normal functioning of the tester, avoid repetitive overloads and shock loads. We hope that this User s Guide will provide a comprehensive explanation of the CTAs operation and sufficient detail on its specifications. However, if you have any other questions or concerns, our technical support and engineering teams will be eager to help you. Thank you again for your purchase and happy testing! TABLE OF CONTENTS UNPACKING AND SETTING UP... 3 LIST OF INCLUDED ITEMS... 3 CONTROLS... 4 DISPLAY... 4 POWER... 5 SETTING UP THE SAMPLE... 5 CONFIGURATION... 6 CALIBRATION... 7 OUTPUTS... 8 SPECIFICATIONS... 9 DIMENSIONS... 10 WARRANTY... 10 OTHER MARK-10 PRODUCTS... 11

UNPACKING AND SETTING UP User s Guide 1. Carefully unpack the CTA and check for any damage. Inspect the contents to ensure that you have received a tester complete with all accessories see List of included items below. 2. Place the tester on a firm, flat and level working surface free from vibration. If preferred, the CTA can be secured to a work bench with screws through the four tapped holes in the underside of the base. Then fasten the sample gripping posts into the desired holes on the sliders (see Fig. 1). Quantity Item 1 Series CTA Torque Tester 4 Sample gripping posts 2 Flat jaws set (optional, see below) 1 Adjustable jaws set (optional, see below) 1 Carrying case (optional) 1 AC adapter 1 Battery 1 Certificate of calibration CT001 flat jaws (optional) These jaws are designed for use with square or other shaped containers, in addition to round samples. The jaws are reversible; one side has a V-groove, while the other side is flat. These jaws can be mounted to the inside of the sliders, or the outside. CT003 adjustable jaws (optional) These jaws are designed for use with unique shaped samples. The four gripping arms per jaw may be independently repositioned in 45 increments to accommodate unique profiles. Loosen the screw at the top of the jaw to separate the arms and reposition as desired. 3

Series CTA Cap Torque Testers CONTROLS POWER / ENTER Turns power on and off. Also used to select configuration menu items. PEAK / ADVANCE Used to switch between Clockwise Peak, Counterclockwise Peak and Normal (real time) display modes. The actual peak readings are always captured and can be recalled at any time by pressing this button. Also used to step through configuration menu items. ZERO Zeros any tare value (up to the full capacity of the gauge) and clears the peak readings stored in memory. DATA Used to output the torque data point currently displayed. UNITS Changes measurement units between lbin, Ncm, and kgmm. DISPLAY The display consists of a 4 1/2-digit section and several indicators. Their functions are listed below. LO BAT CW CCW CW PEAK CCW PEAK LBIN, NCM, KGMM Low battery voltage indicator Clockwise torque indicator Counterclockwise torque indicator Peak clockwise torque indicator Peak counterclockwise torque indicator Units of measurement - - - - (dashes) Overload (>110% of range) Reduce torque immediately 4

POWER User s Guide The CTA can be operated by the included 9V non-rechargeable battery or by the included AC adapter. Battery life is approximately 30 hours. Do not use adapters other than supplied or instrument damage may occur. There are three levels of low battery voltage indication. At the first level the display shows a steady "LO BAT" indicating approximately one hour of charge remaining. The second level is indicated by a flashing "LO BAT" indicator. At the third level the whole display except the "LO BAT" indicator will flash for three seconds after which time the instrument will turn itself off. This prevents the instrument from working at voltages too low for reliable operation. To access the battery, loosen the four screws on the bottom plate. SETTING UP THE SAMPLE Place the sample between the posts or jaws of the tester, and tighten, using the knob. Posts can be placed in any of the holes on the sliders (see Figs. 1 & 2 below). Ensure that the sample is gripped firmly, however, excessive tightening of thin-walled closures may result in sample deformation, possibly affecting test results. When the sample is secured, gradually exert torque by hand. Sudden torque application may produce incorrect readings. Fig. 1 Posts can easily be moved between holes Fig. 2 Optional jaws offer alternative gripping methods 5

Series CTA Cap Torque Testers CONFIGURATION Series CTA torque testers have several features with programmable options allowing many user-specified choices. To enter the configuration menu, perform the following: 1. Turn off the tester 2. Press and hold PEAK 3. Turn on the tester 4. Release PEAK The version number of the internal software will be displayed for a short time. The following secondary functions of keys are used during the configuration process: ENTER ADVANCE Used to select a menu choice Used to step through menu choices NOTE: Once the menu has been entered, it can only be exited if changes have been made. The following list shows all configuration options. Italics indicate factory settings. 232 - RS-232 settings sub-menu 232d Output Disabled 232E Output Enabled 300 300 baud 600 600 baud 1200 1200 baud 2400 2400 baud 4800 4800 baud 9600 9600 baud 7-1E 7 data bits, 1 stop bit, even parity 7-1o 7 data bits, 1 stop bit, odd parity 7-2E 7 data bits, 2 stop bits, even parity 7-2o 7 data bits, 2 stop bits, odd parity 7-2n 7 data bits, 2 stop bits, no parity 8-1E 8 data bits, 1 stop bit, even parity 8-1o 8 data bits, 1 stop bit, odd parity 8-1n 8 data bits, 1 stop bit, no parity 8-2n 8 data bits, 2 stop bits, no parity Ft F Ft n Full data (numeric + units) Numeric data only bcd - Mitutoyo BCD settings sub-menu bcdd Output disabled bcd E Mitutoyo BCD output enabled 6

User s Guide AoFF - Automatic shutoff settings sub-menu no Disabled 1 1-minute automatic shutoff 5 5-minute 10 10-minute 20 20-minute " " 30 30-minute " " init - Initial (default) settings sub-menu LBIN Pound-inch as default unit KGMM Kilogram-millimeter as default unit NCM Newton-centimeter as default unit CCW Real time display at turn on PEAK CW Peak clockwise display at turn on PEAK CCW Peak counterclockwise display at turn on CAL - Calibration sub-menu. See CALIBRATION section. CALIBRATION To properly calibrate the CTA, application of a precise torque value equal to the full capacity of the tester in pound-inches (regardless of the displayed units) is required. While holding PEAK, turn on power to the tester. When CAL appears on the display, press ENTER three times to select the calibration mode. At the null prompt, press ZERO. At the SPAn prompt, apply the calibration torque and press ENTER. The display will show uuuu or nnnn if the calibration torque is insufficient or excessive, respectively. If this happens, the only way to terminate the calibration mode is by momentarily disconnecting the battery or connecting the AC adapter to the tester without plugging the other end into a wall outlet. This will stop the calibration procedure without making any changes to the previous calibration data. Successful calibration is indicated by done on the display. Press ENTER to save the changes and resume normal operation. 7

Series CTA Cap Torque Testers OUTPUTS RS-232 Data transmission can be initiated by pressing DATA or through an external device by sending ASCII "?". The tester will respond by sending the current reading in either full or numeric format, depending on the configuration setting (see Configuration section). Polarity sign indicates CW (+) or CCW (-) torque. The transmitted string has the following format: [POLARITY (SPACE OR -)][DATA][SPACE][UNITS (IF ENABLED)][CRLF] Mitutoyo BCD This output is useful for connection to data collectors, printers, multiplexers or any other device capable of accepting Mitutoyo BCD data. The transmission is initiated by pressing DATA or by the receiving device. I/O connector pin diagram 1 RS-232 receive Input 1 2 3 4 5 2 RS-232 transmit Output 3 Mitutoyo request Input 4 Mitutoyo clock Output 5 Signal ground - 6 7 8 9 6 No Connection - 7 No Connection - 8 Mitutoyo ready Output DB-9P 9 Mitutoyo data Output 8

User s Guide SPECIFICATIONS Accuracy: Sampling rate: 65/s Display update rate: Safe overload: ±0.5% of full scale ±1digit 2.5/s in normal mode, 65/s in peak mode 150% of gauge capacity. Display shows ---- (dashes) above 110%. Outputs (optional): RS-232: Baud rates between 300 and 9600 Mitutoyo: Standard Mitutoyo BCD output Connector: 9-pin D-type male Power: 9V battery or AC adapter Battery life: 30 hours of continuous operation Weight: 6.5 lb [2.9 kg] Capacity x resolution: CTA12 12 x 0.01 lbfin, 140 x 0.1 kgfmm, 135 x 0.1 Ncm CTA50 50 x 0.05 lbfin, 580 x 0.5 kgfmm, 570 x 0.5 Ncm CTA100 100 x 0.1 lbfin, 1150 x 1 kgfmm, 1150 x 1 Ncm 9

Series CTA Cap Torque Testers DIMENSIONS in [mm] 7.8 [199.3] WITH OPTIONAL FLAT JAWS: 5.9 [149.9] MAX 1.3 [33.0] MIN 4.4 [111.8] MAX 0 MIN WITH OPTIONAL ADJUSTABLE JAWS: Ø4.6 [116.8] MAX Ø0 MIN Ø7.5 [189.4] MAX Ø0.5 [12.7] MIN Ø6.0 [151.9] MAX Ø1.3 [33.0] MIN 4.8 [121.8] 1.3 [33.0] 10.7 [270.5] Ø4.4 [111.8] MAX Ø0.25 [6.35] MIN WARRANTY Mark-10 Corporation expressly warrants to its buyer for three (3) years from the date of delivery that the goods sold are free from defects in workmanship and materials. Mark-10 Corporation will, at its option, repair or replace or refund the purchase price of goods found to be defective. This remedy shall be the buyer s sole and exclusive remedy. Any modification, abuse, exposure to corrosive environment or use other than intended will void this warranty. This warranty is in lieu of all other warranties, including implied warranties of merchantability and fitness for an intended purpose. In no event shall Mark- 10 Corporation be liable for any incidental and consequential damages in connection with goods sold or any part thereof. 10

OTHER MARK-10 PRODUCTS User s Guide A full line of force and torque measurement products and related items, including force gauges, torque gauges, force and torque test stands, sensors, grips, software, and more. 11

Mark-10 Corporation has been an innovator in the Force and Torque measurement fields since 1979. We strive to achieve 100% customer satisfaction through excellence in product design, manufacturing and customer support. In addition to our standard line of products we can provide modifications and custom designs for OEM applications. Our engineering team is eager to satisfy any special requirements. Please contact us for further information or suggestions for improvement. We make a measurable difference in force and torque measurement Mark-10 Corporation 11 Dixon Avenue Copiague, NY 11726 USA 1-888-MARK-TEN Tel: 631-842-9200 Fax: 631-842-9201 Internet: www.mark-10.com Email: info@mark-10.com 32-1105 REV 2 0710