SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Similar documents
SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives

5 MICROMASTER 420 specifications

Variable Frequency Drives

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

5 MICROMASTER 440 specifications

PowerFlex 400 AC Drive Guide Specification

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

A drive dedicated to variable speed control for HVAC applications

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

ACH550 Product Overview

VLT 2800 DRIVE SPECIFICATIONS

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Submittal Schedule Details for VFD-P101, P201, P202, P310, P302, P401, P402

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Easy To Use OEMS Take Note

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

SECTION VARIABLE FREQUENCY DRIVES

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Actuator Commissioning Tool

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

IPS INTELLIGENT PUMP STARTER

SED2 Variable Frequency Drives

Q9 ASD LOW VOLTAGE DRIVE

ENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET

Submittal Data Information SmartDRIVE HVAC Variable Speed Drives

BuildingName The Description of the Project P DOCUMENTS

P7BR. Description 5-500HP P7/Bypass NEMA 3R. Phone: Fax: Page Web: 61www.clrwtr.com -

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

VFD 4x STAINLESS STEEL ENCLOSURE WITH AC. engineering data and specifications

SSW06. Soft Starters.

SMARTSTART MOTOR STARTERS

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

Installation Manual Updated May 2017

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Submittal Data Information SmartDRIVE SP Variable Speed Drives

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Submittal Data Information SmartDRIVE VP Variable Speed Drives

XT-9100 Technical Bulletin

160 AA02SF1 AF DS-D17

TR200 DRIVE WITH ELECTRONICALLY CONTROLLED BYPASS SYSTEM

PowerFlex 40 Sample Specification

RWD68U Universal Controller

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Motor Controllers Variable Frequency AC Drives Type VariFlex 2 RVCF

ABB Component Drives ACS55, 0.25 to 3 Hp

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

Smartstart Control Module

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

For additional PowerFlex 4M data and general drive information, refer to the following publications:

ACS Product Overview

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

ADJUSTABLE SPEED DRIVES. Q9 Series

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

TR150 DRIVE STANDARD FEATURES

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Single Phase Systems-North American PC125/PC420 Series

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Jockey Pump Controllers

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Andover ContinuumTM Infinet II

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

60103 Circuit Breaker

Jockey Pump Controllers

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

ENGINEERED SOLUTIONS. Solutions for Any Application. us.mitsubishielectric.com/fa/en/

E1 Plus Electronic Overload Relay

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

S-Flex Enclosed Drive

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

GE Power Management. MMII Intelligent MCC Controller

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Transcription:

SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2 s, see the SED2 Variable Frequency Drives Submittal Sheet (154-042). E- Features Enhanced visual interface for improved monitoring and diagnostics E- guarantees continuous operation even if SED2 fails Electronic touch-sensitive keypad Standard built-in networking compatibility Service mode isolates drive from the control scheme Six relay outputs for indication of operation Fourteen LEDs indicate monitoring and operation Six digital inputs Remote start via networking s electrically and mechanically interlocked. 2-: Output & Overload protection in bypass mode 3- (optional):, Output, &. 3- features provide: Drive test function Device Disconnect Complete electrical isolation of drive Fused disconnect (optional) Circuit breaker (optional) All doors are interlocked and padlockable VF0302R1 Drive 2 Device Drive 3 Device Reactor Options Line reactor mounted in bypass option enclosure Line reactor (in NEMA 1 enclosure) supplied separately Load reactor mounted in bypass option enclosure Load reactor (in NEMA 1 enclosure) supplied separately E- Control Features Auto Relay logic allows user to send the motor to bypass mode based on the drive s programmable relay. The drive s programmable relay, typically set to fault, can be set up for applications that run full speed for an extended period of time. Enable Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Common Remote /Stop Common remote start/stop can be used in both drive and bypass mode. Essential Services Mode Also used for smoke purge; the motor goes to bypass regardless of the selected mode. No call to stop will have an effect, including open safety or stop commands. Only turning the power off or opening this contact will stop the motor. Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 1 of 7

SED2 Variable Frequency Drives E- Options E- Door Mounted Control Devices 0096R1 Enable STOP RESET INTERLOCK START LOGIC Overload Relay Output Auto Enabled Essential Services Hand Remote Fault Safety Fault Overload Fault Enable Commanded Proofed Figure 1. 2- Unit Keypad. Product Numbers 0097R1 On/Off Enable STOP RESET INTERLOCK START LOGIC Overload Relay Output Auto Enabled Essential Services Hand Remote Fault Safety Fault Overload Fault Enable Commanded Proofed Figure 2. 3- Unit Keypad. The following example shows: VBE340.F120X = SED2 with E-, 480V, 40 hp, fused disconnect, NEMA 1, 2 contactors, and no reactors. Your Product Number: V B E X Example Product Number: V B E 3 4 0. F 1 2 0 X Model: VB - with Series E- Electronic Voltage: 1 = 208V 2 = 230 to 240V 3 = 380 to 480V 4 = 500 to 600V HP Rating: 0.5, 0.7, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10., 15., 20., 25., 30., 40., 50., 60., 75., 100, 125 Disconnect: B = Circuit Breaker D = Disconnect F = Fused Disconnect NEMA: 1 = NEMA Type 1 s 2 = 2 s 3 = 3 s Reactor 0 = None 3 = Line Reactor * L = Load Reactor * Filter X No Filter Options HA1 = High Amp rating *Only one reactor type can be installed in the bypass enclosure. If both are required, a separate enclosed reactor is required. TE: HA1 option is a bypass package rated to 178 amps at 480 Vac. Though it does not meet NEC for 150 hp at 180 amps, the package will control a high percentage of 150 hp motors. Typical Specifications SED2 E- Options shall send the motor to bypass mode based on an easily accessible door-mounted selector or based on user's desired conditions. LED indication of operational state shall be provided. The bypass mode shall provide overload protection. s shall be electrically and mechanically interlocked. An essential services mode shall send the motor to bypass regardless of the selected mode. When in safety modes it should provide indication of return state. It should indicate interlock sequence state during transition. Visually indicate faults for safety/overload. Dimensions 0127R1 9.6 (24) = Protective Shield 34 (86) 12.2 (31) 13.2 (34) 12.4 (31) Frame Size A and B 58.5 (149) 20.8 (53) 19.9 (51) 1.5 (3.8) 9.6 (24) 10.5 TYP (27) 1.5 (3.8) Frame Size E 48 (122) 2.9 (7.4) 3 (7.6) 10 TYP (25) 5.5 (14) 11.5 (29) 10.6 (27) Frame Size C 57.5 (146) 1 10.4 (26) (2.5) 2 (5) 11 TYP (28) 2 (5) 57.5 (146) 45.5 (116) 20.8 (53) 19.9 (51) Frame Size D Frame Size F Figure 3. Dimensions in Inches (Centimeters). Table 1. Approximate Weights. Frame Size Weight lb (kg) A 45 (20) B 55 (25) C 75 (34) D 150 (68) E 180 (82) F 470 (213) 2.9 (7.4) 4 (10) 11.5 TYP (29) 3.4 (8.6) 17.4 (44) TE: Exact weight will be affected by actual hp/voltage and selected power options. Page 2 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.

SED2 Variable Frequency Drives E- Options Submittal Sheet Table 2. Frame Sizes and Power Ranges. HP kw 208/230V 480V 575V.5.37.75.55 A 1.75 1.5 1.1 2 1.5 B 3 2.2 5 4 7.5 5.5 C 10 7.5 15 11 20 15 D 25 18.5 30 22 E 40 30 50 37 F 60 45 75 55 100 75 125 90 N/A HA1 A B C D E F C D E F N/A Table 3. Output Current Ratings (Amps) Per NEC Tables. HP.5.75 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 HA1 208V 2.3 3.0 3.9 5.5 7.4 10.4 16.7 22 28 42 54 68 80 104 130 154 230V 2.2 3.0 3.9 5.5 6.8 9.6 15.2 22 28 42 54 68 80 104 130 154 460V 1.1 1.6 2.1 3.0 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 156 178 575V.9 1.3 1.4 2.1 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 99 125 TE: Drives are current rated devices. Verify that the listed ratings are the motor full load current rating. Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 3 of 7

SED2 Variable Frequency Drives E- Options Wiring Diagrams POWER SUPPLY 3 PHASE 60 Hz 0160R1 TES: OPTIONAL SUPPLEMENTARY POWER FUSES - MAIN SHORT CIRCUIT PROTECTION BY OTHERS DISC1 (SEE TE 1) L1 1L1 FU1 (T1) (L1) L2 (T2) L3 (T3) LUG 1L2 (L2) 1L3 (L3) 1L1 1L2 TO STEP-DOWN CONTROL TRANSFORMER 2L1 2L2 2L3 OPTIONAL OPTIONAL DRIVE INPUT INPUT LINE CONTACTOR REACTOR M3 3L1 R (2) (1) A1 A2 3L2 S (4) (3) B1 B2 3L3 T (6) (5) C1 C2 L1 L2 L3 U V W M1 (5) (6) (3) (4) OPTIONAL (1) (2) OUTPUT LOAD REACTOR U1 U M2 A1 A2 (1) (2) V1 V B1 B2 (3) (4) W1 W C1 C2 (5) (6) 1. Branch circuit protection to be provided by installer, per UL508A, if not provided with drive. OL1 1T1 (T1) LUG 1T2 (T2) 1T3 (T3) M AC MOTOR (CUSTOMER SUPPLIED) 2. For bypass operation, modify these drive parameters: P0702[0] and P0702[1] = 3, P0748 = Digital Out 1 Reverse ( ). 3. Control and communication wiring should be 300V UL minimum. 4. Communication wiring should be run with maximum separation possible from all other wiring. 5. Essential service mode operates the motor full speed (bypass) with no protection for the motor or system. 6. Ensure that automatic bypass will not damage the system before activating. 7. See Siemens Publication No. 125-3208 for proper fuse and wire sizes. 8. See Siemens Publication No. 125-3201 for SED2 input/output control signal wiring details. Figure 4. Electronic Option Power Wiring Schematic. DRIVE CONTROL TERMINATIONS ANALOG INPUT EXAMPLES Control terminations located on drive I/O module 1 2 3 4 5 6 7 8 9 10 11 +10VDC +0VDC AIN1+ DIN1 DIN2 DIN3 DIN4 ISO 24VDC AIN2+ 12 14 13 16 15 17 27 26 29 28 30 AO1+ PTC A PTC B DIN5 DIN6 AO2+ AIN1- AIN2- AO1- AO2- ISO 0VDC P+ N- 20 21 22 24 23 25 RL1 NC RL1 RL1 COM RL2 NC RL2 RL2 COM Analog input connection examples EXTERNAL 0 TO 10V 2 3 EXTERNAL 0/4 TO 20mA 2 3 4 - + + - SPEED POTENTIOMETER 1 2 3 4.7k Ohm 24VDC POWERED 0/4-20mA DEVICE (POWER CONSUMPTION CANT EXCEED 100mA) 2 3 4 9 28 0125R2 INTER-CONNECTIONS WITH BYPASS FACTORY WIRED ma POWER Figure 5. Drive Terminations. Page 4 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.

SED2 Variable Frequency Drives E- Options Submittal Sheet 0114R2 DIGITAL INPUTS DIGITAL OUTPUTS Remote Remote Safety #1 Remote Safety #2 Interlock Essential Services Overload Trigger Programmable Output, COM NC Fault, COM NC Drive Select, COM Select, COM Running, COM Overload Fault, COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 J2 J1 Figure 6. Controller Board Digital s and Outputs. Specifications Voltage (3-phase) Digital s Table 4. Electronic Specifications. Description 208V, 3 AC±10%. 1/2 hp to 60 hp (2.3 amps to 154 amps) 230V, 3 AC±10%. 1/2 hp to 60 hp (2.3 amps to 154 amps) 460V, 3 AC ±10%. 1/2 hp to 125 hp (1.2 amps to 178 amps) 575V, 3 AC ±10%. 1 hp to 125 hp (2.3 amps to 125 amps) Six Digital s as follows: Remote start input Remote safety 1 Remote safety 2 Interlock start Essential services Overload trigger Relay/Digital Outputs s require a contact closure capable of providing a low impedance path at currents less than 20 ma. Six Relay/Digital Outputs as follows: fault Programmable output Drive select select Running on bypass Overload fault Temperature Humidity Each relay has a maximum rating of 2A at 120V ac. Operating: 14 F to 104 F (-10 C to 40 C) Storage: 40 F to 158 F ( 40 C to 70 C) 0 to 95% rh, non-condensing TE: For technical specifications on the SED2, see the SED2 up, Operation, and Maintenance Manual, (125-3201). Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 5 of 7

SED2 Variable Frequency Drives E- Options Drive Specifications Table 5. Drive Specifications. Description 200V to 240V, 3 ac ± 10%. 1/2 hp to 60 hp (2.3 amps to 154 amps) voltage and power ranges (3-phase), amps 380V to 480V, 3 ac ± 10%. 1/2 hp to 125 hp (1.2 amps to 178 amps) 500V to 600V, 3 ac ± 10%. 1 hp to 125 hp (2.3 amps to 125 amps) frequency 47 Hz to 63 Hz Output frequency 0 Hz to 150 Hz Power factor 0.9 degree of efficiency 96% to 97% Switch-on current Less than nominal input current Auxiliary supply 24V Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 ma Overload capacity 110% for 60 seconds Control method Linear, parabolic and programmable V/f; and flux current control low-power mode PWM frequency 2k Hz to 16k Hz (adjustable in 2k Hz increments) Fixed frequencies Skip frequency bands Setpoint resolution Digital inputs (sink/source) Analog inputs Relay outputs Analog outputs Serial interface Protection level Temperature ranges Humidity Operational altitudes Protection features Standards 15 programmable 4 programmable 0.01 Hz digital 0.01 Hz serial 10 bit analog 6: fully programmable and scalable isolated digital inputs, switchable 2: 0 to 10 Vdc, 0/4 to 20 ma, can also be configured as digital inputs or Ni 1000 input 2: configurable 30 Vdc/5A (resistive), 250 Vac/2A (inductive) 2: programmable (0/4 ma to 20 ma or 0 Vdc to 10 Vdc) RS-485 transmission rate: Up to 38.4k baud Protocols: Siemens Building Technologies, Inc., P1 and Johnson, N2 IP20: NEMA Type 1 with protective shield and gland plate installed IP54: NEMA Type 12 (400V and 500V series only) Operating: 14 F to 104 F ( 10 C to 40 C) Storage: 40 F to 158 F ( 40 C to 70 C) 95% rh, non-condensing Up to 3280 ft (1000 m) above sea level without derating Under-voltage Stall prevention Over-voltage Locked motor Overload overtemperature l2 t, PTC Ground fault Over-temperature Short circuit Parameter PIN protection UL, cul Page 6 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.

SED2 Variable Frequency Drives E- Options Submittal Sheet Table 6. Order Worksheet. Item Qty. Designation Part Number Description Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Other product or company names mentioned herein may be the trademarks of their respective owners. 2004 Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A. Your feedback is important to us. If you have comments about this document, please send them to technical.editor@siemens.com Country of Origin: US Page 7 of 7