This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Similar documents
Converts any fiber optics type interface to any other fiber optics type interface.

Multi-Power Miniature Media Converter 10/100/1000

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Choose from four different ways to power these hardened media converters.

Industrial SFP/SFP Multi-Power Mode Converter

These tiny media converters are perfect for bringing fiber to the desktop.

Add 10/100 copper ports to a High Density Media Converter Chassis.

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Giga-MiniMc TX & RX USER MANUAL

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

IE-MediaChassis/1. Operation Manual

PC Media Converter, Switching (TP-TX/FX)

International Headquarters

Connects 1000BASE-T twisted-pair to 1000BASE-SX/LX fiber.

10/100 Autosensing PC Media Converter

MiniMc TP-TX/FX MiniMc TP-TX/SFP. Operation Manual

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

Bridge Module. Installation Guide and Users Reference Manual

Giga-MiniMc TX/FX Giga-MiniMc TX/SFP. Operation Manual

IE-Giga-MiniMc. Operation Manual. FCC Radio Frequency Interference Statement. Limited Lifetime Warranty

LVN5200A-R2, rev. 1, Hardware Installation Guide

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

FiberLinX Modules Hardware Installation Manual

Giga-MiniMc with LFPT. Operation Manual

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

PoE Giga-McBasic PoE+ Giga-McBasic with LFPT. Operation Manual

International Headquarters. European Headquarters

IE-iMcV-2xLIM, TX/SFP. Operation Manual

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

imcv-ds3/e3/sts Repeater

Allworx Tx 92/24 Telephone Expander Installation Guide

Perle MCR200 Installation Guide

High Density Media Converter System II 20-Slot Rackmount Chassis

G.SHDSL NTU with Fixed Serial Interfaces

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

G.SHDSL NTU DECEMBER 2006 LB510A

HD40H(X) Performance Series Camera. User Guide

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

imediachassis Series imediachassis/20 imediachassis/6 imediachassis/3 Operation Manual

USB USB Data Transfer

Daily use. indicating that the loud speakers

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

About PoE Compact Media Converters

USER MANUAL. Elo Touch Solutions 2D Barcode Scanner Peripheral

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

TRC-190 User s Manual

Quick Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

9362 Enterprise Cell V2.2 WCDMA B2/B5. Getting Started Guide

Connectivity Peripherals User s Guide. Point 510 Point 1600

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Express All-Fiber DVI. User s Manual (For M1-1000)

Enclosure TS-530 User Manual

DATA DOUBLER. Apple Mac mini (2009)

FRG-3105 Series Residential Gateway

FCC Regulatory Information

TruVision IP Thermal Camera Installation Guide

5/8 Port Gigabit Ethernet Switch

Installing and Configuring Rialto Analytic Appliances

16-SLOT IN-BAND MANAGEMENT CHASSIS

2 Mesa Ethernet Dock User s Manual

FEMTOCELL MULTI-BAND SOHO B2/B4 (SS2FII)

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

USB 2.0 CAT5E/6/7 EXTENDER

Installation Job Aid for Ethernet Routing Switch 5900 Series

RS-232/RS-422 Optical Isolator

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Installation Job Aid for Ethernet Routing Switch 3600 Series

Quick Installation Guide

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Replacing the Power Supply

CSM200 Expansion Tray

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

SANnet II Family Safety, Regulatory, and Compliance Manual

SP-PoE Splitter User Manual

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs

Bluetooth Shielding Instructions

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

NI PXI-1042 Series Power Supply Shuttle

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

PA Series. Available in 6.0MP and 8.0MP

User Manual. eufy Security SpaceView Baby Monitor

MONTANa. User s Guide

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

3M Wrist Strap and Ground Monitor 773. User s Guide

Quick Installation Guide

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

SP-1V SPEAKER USER GUIDE

InnoMedia ipbx-400. Quick Install Guide.

Version 1.0 December isappos 4 / isappos 5 Scanner Jacket

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Transcription:

LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

TRADEMARKS USED IN THIS MANUAL Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. Page 2 724-746-5500 blackbox.com LMC5103A-R2

FCC and IC RFI Statements FCC and Industry Canada RF Interference Statements Class B Digital Device. This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or telephone reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult an experienced radio/tv technician for help. CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. To meet FCC requirements, shielded cables and power cords are required to connect this device to a personal computer or other Class B certified device. This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. LMC5103A-R2 724-746-5500 blackbox.com Page 3

Certifications Certifications Class 1 Laser product, Luokan 1 Laserlaite, Laser Klasse 1, Appareil A Laser de Classe European Directive 2002/96/EC (WEEE) requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste. This symbol indicates that the equipment should be disposed of separately from regular household waste. It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities. Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about proper disposal, please contact local authorities, waste disposal services, or the point of purchase for this equipment. Page 4 724-746-5500 blackbox.com LMC5103A-R2

Table of Contents Table of Contents Part Numbers... 6 1. Specifications... 7 2. Overview: About the 1-slot Multipower Desktop Chassis... 8 3. Install the 1-slot Multipower Desktop Chassis... 9 3.1 Configuring and Installing Modules... 9 3.2 Installing the 1-slot Multipower Desktop Chassis... 9 3.2.1 Table Top Installation... 9 3.2.2 Wall Mount Installation... 9 3.2.3 DIN Rail Mounting... 9 3.3 Powering the 1-slot Multipower Desktop Chassis... 10 3.3.1 DC Terminal Block Wiring Instructions... 10 3.3.2 Cascading DC Power... 11 3.3.3 DC Power Supply Precautions... 11 4. Contacting Black Box... 13 5. Fiber Optic Cleaning Guidelines... 14 6. Electrostatic Discharge Precautions... 15 LMC5103A-R2 724-746-5500 blackbox.com Page 5

Part Numbers Part Numbers Part Number LMC5103A-R2 Description 1-slot Multipower Desktop Chassis Page 6 724-746-5500 blackbox.com LMC5103A-R2

Chapter 1: Specifications 1. Specifications DC Input AC Wall Adapter Operating Temperature Storage Temperature Humidity Dimensions ±7 to ±50 VDC on DC terminal 5-20 VDC on DC jack 100-240 ±10% VAC input, 5VDC output, 2A max. -13 F to +185 F (-25 C to +85 C) with DC terminal +14 F to +122 F (-10 C to +50 C) with AC wall adapter -49 F to +185 F (-45 C to +85 C) 5 95% (non-condensing); 0 10,000 ft. altitude 0.91"H x 4.30"W x 4.00"D (2.3H x 10.9W x 10.2D cm) NOTE The stated operating temperature is only applicable when used with modules that also accommodate the same operating temperature. LMC5103A-R2 724-746-5500 blackbox.com Page 7

Chapter 2: Overview 2. Overview: About the 1-slot Multipower Desktop Chassis The 1-slot Multipower Desktop Chassis is a compact and modular, single-slot table-top unit that hosts a variety of Black Box SNMP Manageable Modules. The 1-slot Multipower Desktop Chassis has two power options: a 4-terminal DC power block, and a country-specific external AC power adapter. In addition, the 1-slot Multipower Desktop Chassis also includes an extended voltage range; an extended operating temperature; and DIN clips for mounting the enclosure on a DIN rail. Deploy these standalone chassis at the customer premises (CPE) or each access point. Page 8 724-746-5500 blackbox.com LMC5103A-R2

Chapter 3: Install the 1-slot Multipower Desktop Chassis 3. Install the 1-slot Multipower Desktop Chassis 3.1 Configuring and Installing Modules To install a module (any module except those that are double- wide), slide the module into the chassis until the module is firmly seated in the backplane. Secure the module to the chassis by tightening the captive screw. 3.2 Installing the 1-slot Multipower Desktop Chassis The 1-slot Multipower Desktop Chassis installs virtually anywhere: as a standalone, table-top device, on a DIN rail, or wall mounted. 3.2.1 Table Top Installation As a table-top unit, install the 1-slot Multipower Desktop Chassis by placing it on a flat surface. Make sure to leave adequate space on top of the unit to accommodate cooling. Attach the network cables between the module and other devices that will be interconnected, and then plug the unit into a reliable, filtered power source. 3.2.2 Wall Mount Installation Holes on the bottom of the unit (see diagram below) allow the 1-slot Multipower Desktop Chassis to be wall mounted. Simply place screws (size #6; not supplied) on the wall at the distance of the holes on the 1-slot Multipower Desktop Chassis, then hang the unit on the screws. Attach the cables between the 1-slot Multipower Desktop Chassis and each device that will be interconnected, and then plug the unit into a reliable, filtered power source. 3.2.3 DIN Rail Mounting The 1-slot Multipower Desktop Chassis ships from Black Box with DIN clips allowing installation on a DIN Rail. The DIN Rail clips include screws, to allow the installation onto a DIN Rail. Install the screws into DIN Rail clips, which should be mounted perpendicular to the DIN Rail. Snap the converter onto the clips. To remove the converter from the DIN Rail, use a flat-head screwdriver into the slot to gently pry the converter from the rail. NOTE The DIN clips are designed for use on a DIN-35 rail. LMC5103A-R2 724-746-5500 blackbox.com Page 9

Chapter 3: Install the 1-slot Multipower Desktop Chassis 3.3 Powering the 1-slot Multipower Desktop Chassis The 1-slot Multipower Desktop Chassis includes multiple powering options. Any of the following options can be used, or more than one for redundancy: A country-specific, high-reliability AC power adapter (included) The 4-terminal DC power block 3.3.1 DC Terminal Block Wiring Instructions The 1-slot Multipower Desktop Chassis can also be powered with the DC terminal block. From a power source, connect to any one positive and any one negative terminal on the 1-slot Multipower Desktop Chassis. The following chart illustrates an example of the wiring configurations for the DC terminal block of the 1-slot Multipower Desktop Chassis (±7 to ±50 VDC). NOTE When using stranded wire, the leads must be tinned. The chassis is protected against miswiring; if miswired, the chassis will not function. The chassis is internally connected to the negative power terminal. Page 10 724-746-5500 blackbox.com LMC5103A-R2

Chapter 3: Install the 1-slot Multipower Desktop Chassis The power source in this chassis is not isolated, and cannot support positive reference ground systems typically used in Telco environments. 3.3.2 Cascading DC Power When installing multiple IE-MediaChassis/1 units on a DIN rail, use one DC input source then cascade from one DC block to the next, until reaching the maximum current available. Make sure to connect positive to positive and negative to negative. 3.3.3 DC Power Supply Precautions The following precautions should be observed when installing chassis with DC power supplies. 1. Check nameplate ratings to assure there is no overloading of supply circuits that could have an effect on overcurrent protection and supply wiring. 2. When installing DC equipment, it must be installed only per the following conditions: LMC5103A-R2 724-746-5500 blackbox.com Page 11

Chapter 3: Install the 1-slot Multipower Desktop Chassis a. Connect the equipment to a ±7 to ±50 VDC supply source that is electrically isolated form the alternating current source. The ±7 to ±50 VDC source is to be connected to a SELV source. b. Input wiring to terminal block must be routed and secured in such a manner that it is protected from damage and stress. Do not route wiring past sharp edges or moving parts. c. A readily accessible disconnect device, with a 3 mm minimum contact gap, shall be incorporated in the fixed wiring. 3. Grounding: reliable grounding of this equipment must be maintained. Particular attention should be given to supply connections when connecting to power strips, rather than direct connections to the branch circuit. Page 12 724-746-5500 blackbox.com LMC5103A-R2

Chapter 4: Contacting Black Box 4. Contacting Black Box Black Box Customer Service Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) Free technical support, 24 hours a day, 7 days a week. Call: 724-746-5500 or Fax: 724-746-0746 Mail order: Black Box Corporation 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com LMC5103A-R2 724-746-5500 blackbox.com Page 13

Chapter 5: Fiber Optic Cleaning Guidelines 5. Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality components can cause many hard-todiagnose problems in an installation. 2. Dust caps are installed at Black Box to ensure factory-clean optical devices. These protective caps should not be removed until the moment of connecting the fiber cable to the device. If you need to disconnect the fiber device, reinstall the protective dust caps. 3. Store spare caps in a dust-free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics. 4. If you suspect that the optics have been contaminated, alternate between blasting with clean, dry, compressed air and flushing with methanol to remove particles of dirt. Page 14 724-746-5500 blackbox.com LMC5103A-R2

6. Electrostatic Discharge Precautions Chapter 6: Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products. 1. Do not remove unit from its protective packaging until ready to install. 2. Wear an ESD wrist grounding strap before handling any module or component. If the wrist strap is not available, maintain grounded contact with the system unit throughout any procedure requiring ESD protection. 3. Hold the units by the edges; do not touch the electronic components or gold connectors. 4. After removal, always place the boards on a grounded, static-free surface, ESD pad or in a proper ESD bag. Do not slide the modules or stand alone units over any surface. WARNING! Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage. Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices. LMC5103A-R2 724-746-5500 blackbox.com Page 15

LMC5103A-R2 Rev. 1 50-80101BB-00 Rev. A1