TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Similar documents
TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Temperature/Process Controllers Manual

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

MLC 9000 Bus Compatible PID

/8 DIN Universal Process Indicator

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

C500 Series Data Sheet

NF760 Batch Controller

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Wall-/Pipe Mounted Universal Process Indicator

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

LAUREL ELECTRONICS, INC.

LCp-100 Weight Indicator/Transmitter

C160 Wall-/Pipe Mounted Universal Process Indicator

Strain Gauge Converter

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

GS100P. Weighing Controller. Contents. Order Codes

Digital Indicator Solutions

Trident and Trident X2 Digital Process and Temperature Panel Meter

SX90 Process Controller

The CAL range of temperature controllers

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

DIGITAL INDICATING CONTROLLER

/8 DIN Motorized Valve Controller

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

Neon pr. ph/ ORP measurement. Applications. Description

NF770 Temperature Compensation Liquid Flow Computer

Vibration-Resistant Weighing Indicator

MIC-2 MKII, Multi-instrument DATA SHEET

02/11/2015

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

GS125. Contents. Features. Optional. Strain Gauge Input LED Large Display

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Characteristics and functioning

LLR-MOD Modbus Light Level and Occupancy Sensor

M260 Load Cell Amplifiers

Voltage Transducer UMT516 / MT516

3500/53 Electronic Overspeed Detection System

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

100mm Process Indicator Recorder

APEX Junior Cased Weighing Indicator/Controller

E1205 advanced multi-function indicator

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

RT4B-110V/12A RECTIFIER

Characteristics and functioning

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

Energy Management Modular Energy meters Type EM2-96

LBVR1718. Description. Features channel paperless recorder

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

Contents. Temperature & Process Measurement Indicators Setup Guide

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

PD765 TRIDENT. Trident Series Process & Temperature Meters.

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Digital Panel Meters

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

7561-PSD Manual Portable Battery Powered Indicator

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

DINALOG A 144 x 36 A1400 Light-Strip Indicator

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

LC0 DVP

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

PD765 TRIDENT. Trident Series Process & Temperature Meters.

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS

ProVU 4 Advanced Temperature & Process Controller

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

PD Helios Strain Gauge, Load Cell & mv Meter. Strain gauge. Actual Size Digit

Performs many operations, from batch weighing to field bus networking applications.

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

EY-EM : Remote I/O module, ecolink

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

DPR 100 A/B Analog Scales

Micro Motion Model 7950 and Model 7951 Signal Converters

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

RXTH DUAL ROOM SENSOR / SWITCH

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Maxxis 4 Process Controller with BASIC Application

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

UniPak UP448 Bridge Input Isolating Signal Conditioner

Business. Republic of SEWHACNM to the world beyond. 1 2 Industrial Automation

Safe-Weigh Process Weighing System

High Voltage DC Meter

MIC-2 Multi-instrument DATA SHEET

Transcription:

TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation Supply Max / Min Memory Isolated Analogue Output Digital Status Inputs In-Flight Compensation Part Counting And Peak Picking Adjustable Display Resolution Universal Power Supply Alarm and Control Outputs Transducer Excitation Supplies 10Vdc (or 20 volts dc for use with I.S. barriers) fully drift compeniated. 6 Wire Ratiometric Input for maximum measurement precision. Tough but Attractive The enclosure uses flame retardant (VO) materials and the front conforms to IP65. Clear Display The flat recessed five digit display together with high brightness LED s ensure maximum visibility even in difficult lighting conditions. Universal Power Input Wide ranging 90 to 265Vac input allows worldwide installation. A low voltage 24Vac/dc input option is available. The Tracker 240 series of digital panel indicators are designed specifically for use with load cell transducers and for weighing applications. All the Tracker 240 series models have a 5 digit display and transducer supply plus many software features including tare, offset zeroing, in-flight compensation, peak picking and extensive alarm functions. As standard the Tracker 240 series are fitted with an analogue output and an RS 422/485 communications interface to allow connection to data loggers, chart recorders, PLCs and computers. All models have the same specification except that the T244 has two relay outputs to control external devices and the Tracker 245 has four TTL logic outputs. The displayed value can be in tonnes, litres, grams or any other engineering unit. The Tracker 240 series can be used in conjunction with up to four 300 Ohm load cells, and uses a 6-wire ratiometric measurement technique. Power for the load cells can be provided from the internal regulated supply or from an external supply.

TRACKER 240 APPLICATIONS Fill and (optional) Trickle Feeder Control The Tracker 240 series relay or TTL outputs can be used to control filling of a container which is placed on a single load cell or on multiple load cells wired in parallel. The container weight can be compensated for by using the Tare or function. The Tracker 240 controls the (high speed) feed device and, at a user definable point during the filling, switches off the high speed fill and switches on an optional Trickle (low speed) feed to achieve an accurate total fill weight. (See also in-flight compensation below.) Loss of Weight/ Discharge Control This feature calculates the loss of weight of the feeder reservoir, rather than measuring the weight of the vessel that is being filled. Again both a fast feeder and an optional trickle feeder system may be used. The Tracker 240 will measure and control, by use of a logic or relay output, the loss of a pre-set weight of product to the container to be filled. Alarm outputs can also be used to indicate if the reservoir tank is too low or full. The fill command can be entered externally via a logic input, or by pressing a front panel function button. FILL Valve Control Signals Filler Reservoir Low Alarm Filler Reservoir High Alarm Feeder Reservoir Fast Feed Trickle Feed (Optional) Load Cells Fill Trickle (Option) Valve Control Signal Load Cell(s) Signal Start Fill Signal Container to be filled Automatic In-Flight Compensation In-flight compensation allows the filling system to switch off the filler valve before the correct weight has been reached. This may be required if some of the product could be delivered for a time after the filler control valve has been switched off. The In-flight compensation can be applied to both the main feed and trickle feed controls outputs. Filler Reservoir Product level at the required weight Control Valve Product In-Flight after the control valve is closed Learn Function A learning function allows the Tracker 240 series to automatically correct the in-flight compensation, so increasing the accuracy of the delivered weight. This compensation is particularly useful when the product's flow rate characteristics change, perhaps due to variations in moisture or temperature. The learn system constantly adjusts the switching point to optimise for changing product condition. Peak Picking This useful feature allows filled containers to be checked for weight, an alarm being activated if the weight falls outside pre-set limits. To eliminate false peak values being displayed due to the load being dropped on to the load cells, a delay can be set before the measurement is displayed and the alarms become operational after crossing a defined threshold level. This delay is programmable between zero (off) and 10 seconds to 0.1 second resolution. The measured value is displayed until the next load is weighed. Alarms are only active while a load is being weighed and after the delay period. Active Value (Delay Timer Start) Input Signal Delay New Measured Value Reset Previous Measured Value Hold Measured Value or Time Out Delay New Measured Value Reset Previous Measured Value High Alarm Limit Low Alarm Limit Hold Measured Value or Time Out Band Function (if used) Auto Setpoint Adjustment For the peak picking application described above, there may be a slight change in the overall weight of the product over time. This may be due to slight differences in the container weight, for example. If a slight error from the setpoint value is seen, the setpoint can be automatically adjusted in a similar way as described in the in-flight learn feature described opposite. If an alarm is activated (due to the weight being out of limits) the setpoint correction is ignored for that measurement cycle. Limits can be set to inhibit the maximum amount of setpoint correction that can occur. +0.5Kg 0.75Kg Load cell signal-load removed Period Period New load applied Automatic ing Band Function Due to the hysteresis of some load cells, the measured value may not return to exactly zero when a load is removed. This function allows the user to set an error band around zero where the Tracker 240 will automatically initiate a zeroing of the measured value, if the reading is within the pre-set band. The error band can be set to any displayable value, and high and low limits can be individually entered. The automatic zeroing band function is repeated as long as the measured value is within the pre-set band, and removes the need to manually zero the instrument before the next load is measured. The time period between zeroing is user selectable. Part Count Function A part count function can be enabled by using a status (logic) input or a front panel push button. The Tracker 240 is used to weigh a single part or known number of parts, this measured value is then used to calculate the total number of parts in a batch.

TRACKER 240 FEATURES Display The user can configure the Tracker 240 series for the required engineering units and display resolution. The resolution is user configurable for 1, 2, 5 and 10 digits. This can be useful if a steady reading is difficult to achieve. Normally the full resolution would be displayed. For noisy signals an independent display filter is provided. The user can select the display update rate to be 2, 4 or 10 per second, and the brightness can be adjusted to suit ambient lighting conditions. Calibration Scaling and User Linearisation Calibrating the Tracker 240 series to load cells can be achieved in one of two ways. Values from the strain gauge can be entered manually or the Tracker can read the actual output from the transducer at two points in the range, normally at zero and another point near the maximum load to be measured. These measured values are stored with their associated display values as the calibration parameters. For more demanding applications, up to 8 points can be independently calibrated to compensate for transducer non linearity. Digital Status (Logic) Inputs Two logic inputs are provided to allow remote control of the indicator functions via external devices such as switches or PLCs. The inputs may be activated by volt free contacts or open collector TTL outputs. The two inputs can be individually programmed by a user to perform one or more of the following functions:- Tare Part Count Display Hold Display Maximum (Peak) Display Minimum (Valley) Display Average Display Reset (Peak Picking Mode) Display Test (Lights all Display Segments) Keyboard Lock Alarm (Latch) Reset Alarm Disable Analogue Output Hold Reset Max, Min and Average Start Fill Front Panel Function Keys The five front panel buttons can be used to set up a unit by stepping through a simple password protected menu. In addition the two front panel function buttons marked and can be individually programmed by a user to give operator level access to one or more of the following functions. Tare Part Count Display Hold Display Maximum (Peak) Display Minimum (Valley) Display Average Display Reset (Peak Picking Mode) Reset Max, Min and Average Display Test (Lights all Display Segments) Start Fill Alarm Menus Alarms can be flashed on the display along with the measured value. The user can individually configure the following parameters for each of the four alarm menus:- High, Low or Deviation Alarm Action High and Low Band Limits (Deviation Action Only) On and Off Delay Timers On and Off Hysteresis Latching or Non-Latching Normal or Pulsed Output Modes Setpoint Adjustment (During normal running or only via password protected menus) When filling modes are selected, Digital (TTL/Relay) outputs 1 and 2 are automatically assigned. Analogue Output The user programmable analogue output allows the Tracker 240 series to transmit the measured display value or the Maximum, Minimum, Average, or a value sent via the serial interface. The analogue output can be scaled for any portion of the display range and is configurable for 4-20mA, 0-20mA or 0-10 Volt signals. Electrical isolation ensures that problems with earth loops are avoided. The Tracker 240 series are equipped with an isolated RS422/485 serial communications interface to allow connection to computers or PLCs. Three protocols are provided as standard to allow easy integration with most SCADA packages. The user can select Master Mode to allow digital transmission to a remote Repeater display or printer. RS232 can be supplied instead of RS422/485 - consult your supplier. Further Load Cells 10 volt dc Excitation Supply Supply Sense Load cell Output Signal Sensor Connections The Tracker 240 series use a 6-wire ratiometeric method of measurement. Up to four 300 ohm load cells can be connected in parallel. More can be used if the resistance is higher (e.g. 8 x 600 ohm load cells) and the total current does not exceed 120mA at 10Vdc. An external 10Vdc supply can be used, if required, still retaining the ratiometric measurement capability. Normally the transducer connections would be wired as shown.

TRACKER 240 FEATURES Smart Filter Often plant vibration can effect the measured values and make the display appear noisy. The Tracker 240 has a smart filter that samples the noisy signal from the load cells and then calculates a filter band value. When in use, the filter is only applied when the measured value rate of change is within the filter band. To allow a fast response for real change of signal the filter is turned off until the signal rate of change is again within the filter band limits. Filter Band Filter on Change of load/weight Filter off Sample Period The Tracker stores the highest and lowest reading taken from approx. 100 samples to determine the noise amplitude. The filter band is then calculated using the max/min stored values from the sampling period. The filter band can also be manually adjusted or turned off. Load cell signal Filter on Filter on Change of load/weight Filter off A RS485 Serial interface is fitted as standard on all Tracker 240 models. Optionally a RS232 interface can be fitted (at extra cost) instead of RS485. The main applications are shown below. Connection to a remote display Connection to a printer Loadcells RS 485 Loadcells Master T240 Slave Indicator(s) Up to 32 - Up to 1Km Master T240 Printer (with a serial interface) PC Configuration Slave T240 Data Acquisition Slave T240 s Connection to HMI (Human Machine Interface) Slave T240 The combination of a Tracker 240 and an HMI, fitted with a Modbus compatible RS485 interface, becomes a powerful stand-alone batch control system and recipe selection system. The HMI s display and function buttons can be tailored for any application and language. Many HMI units can also be a gateway for Fieldbus connection (e.g. Profibus, Device Net). A single HMI can communicate with up to 32 Tracker 240 units.

TRACKER 240 CONFIGURATION Technical Specification Display Range: -19999 to 99999 Type: Red (standard) or green LED 14.7mm high Measurement resolution: User selectable (decimal point) Update rate: Selectable 2, 4 or 10 per second Resolution: Selectable 1, 2, 5 or 10 digits Input ADC Type: Sigma delta, 18 bit resolution (1 part in 262, 144) Measurement mode: Ratiometric Range: 0.5 to 20mV per Volt Connection: 6 wire - 2 x excitation, 2 x sense, 2 x signal Accuracy: Better than 0.02% of reading Measurement rate: 20 per second Input impedance: >100MΩ Common mode rejection: >150dB Series mode rejection: >70dB Transducer Supply Output Regulated 10Vdc @ 120mA (To power up to 4 x 300 Ω Load cells wired in parallel) A 20Vdc output can be supplied for use with I.S. barriers - consult with supplier Digital Outputs Tracker 244 only - 2 off, single change over (form C) contacts rated at 1A @ 240Vac, 5A @ 30Vdc Tracker 245 only - 4 off, TTL open collector Outputs can be energised or de-energised in the alarm condition or configured to give a pulse output Function Keys and Status (Logic) Inputs Functions can be user assigned to two of the front panel buttons and the two digital inputs. The digital inputs can be switched by external volt free contacts or TTL signals. Type: RS 422/485, 2 or 4 wire multidrop Isolation: To 500Vdc/ Peak ac Speed: 1200, 2400, 4800, 9600 baud. Parity: Odd, even or none. Stop bits: 1 or 2 Protocols: MODBUS RTU (J-BUS), MODBUS ASCII and DTPI (Data Track Process Instruments) in master or slave mode. Tracker 240 indicators have been tested and comply with the European Electromagnetic Compatibility Directives and safety requirements. The units are CE marked. Analogue Output Isolation: 500Vdc/ Peak ac Output: User selectable 0-10V, 0-20mA or 4-20mA Scaling: User scaling to any displayable value Accuracy: Better than 0.2% Temperature drift: <100 ppm per 0 C Response: 63% within 32mS, 99% within 100mS Resolution: 0.05% (5mV or 0.01mA) Maximum voltage output: 11V @ 22mA Maximum current output: 22mA @ 18V Maximum load: 900Ω Programmable output damping filter Power Requirements Universal 90 to 265Vac, 50 or 60Hz @ 20VA nominal Optional 24Vdc/ac supply Environmental Temperature: 10 to 50 0 C operating -10 to 70 0 C storage Humidity: 10 to 95% RH non condensing Physical/Mechanical Dimensions: 48mm (H) x 96mm (W) x 173mm (D) Panel cut-out: 44mm (H) x 92mm (W) Depth behind panel: 166mm including terminals Weight: 0.4kg, (0.55kg packed weight) Safety and EMC Safety: EN61010 Susceptibility: EN50082-1 & 2 Emissions: To EN50081-1 & 2 EN50022 Class A for radiated and conducted CE Certified 1997 Ordering Code Model Number Supply Display Colour Model Number: 243 Load Cell Indicator 244 Load Cell Indicator with Dual Alarm Relays 245 Load Cell Indicator with Quad TTL Alarm Outputs Supply: 1. 90-250Vac 2. 24Vdc/ac Display Colour: R Red (Standard) G Green (Option) Example: 244-1-G Tracker 244 Load Cell Indicator with Dual Alarm Relays, Mains Powered and Green Display. Specifications subject to change without notice. All trademarks acknowledged.