Line Impedance Stabilization Network (LISN)

Similar documents
EMSwitch RF Switch Plug-In Card

EMCenter Modular RF Platform. User Manual

Model 7705 Control Module

User's Guide. Extech AM A AC Analog Clamp Meter

S66 Series Electronic Fan Speed Control

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

HV-CS kv Edge Mount Triaxial Jack

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Mini Digital Multimeter

±15 V Current-Limited Power Supply

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Model A Mini AC/DC Clamp Meter. User's Guide

User's Guide. MiniTec TM Series Model MN25 MultiMeter

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

USER'S MANUAL DCL-650

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

iconverter 2-Module Power Chassis

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

TBX-1316 High-Voltage Attenuator Terminal Block

Mini Digital Multimeter

2260B-RMK-Series Rack Mount Kit

Mini Digital Multimeter

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Model 2657A-LIM-3 LO Interconnect Module

Autoranging True RMS Multimeter User Manual

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Models HP Z VR Backpack G1 Dock

Installation Job Aid for Ethernet Routing Switch 3600 Series

SCC-AO10 Isolated Analog Output Module

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 2380 Rack-Mount Kit

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Model GHz 50 Ohm RF Module

Autoranging Mini Multimeter

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Digital Clamp Meter User Manual

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

MODEL 805 USER MANUAL

Specifications, Installation, and Operating Instructions

SCXI -1313A Terminal Block

OPERATING INSTRUCTION

Electrical. SPECIFICATIONS SH Cable

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Automated Tuner System Power Distribution Hub

D15CC55UNVD K/KS. UNV DALI Dimming LED Driver 1500mA Constant Current Output Class 2, 55W Output DALI Dimming to 1% Performance.

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

* * Agilent Power Distribution Unit (PDU) Installation Guide

NI PXI-1042 Series Power Supply Shuttle

Agilent 70612B K18 Switch Matrix

Series 8000 RF Signal Switch Solution

ACCESS 9340/9360 Meter Input/Output Module

Model 2380 Rack-Mount Kit

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

PanelView Plus/VersaView CE Terminals and Display Modules

700 Series 200 Amp Clamp Meters

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

User Guide True RMS Multimeter Extech EX205T

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Site Preparation CHAPTER

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Model VT120 Fast Timing Preamplifier Operating and Service Manual

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

Model 2440 Service Manual Rev. B / December 2004

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Mini Digital Multimeter Model MN15. User's Guide

EPS Power Supply

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

True RMS Multimeter with IR Thermometer

H-series (Rectifier Module)

9040/9040UK. Users Manual. Phase Rotation Indicator

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

87421/22A Power Supply. Operating and Service Manual

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Panel Installation Datasheet

OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL

SCC-RLY01 Relay Module

User's Guide. Digital Multimeter. Model MN42

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

NI PXI-2567 Specifications

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Transcription:

Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual

ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall constitute ETS-Lindgren Inc. assuming any liability whatsoever arising out of the application or use of any product or circuit described herein. ETS-Lindgren Inc. does not convey any license under its patent rights or the rights of others. Copyright 1999 2014 by ETS-Lindgren Inc. All Rights Reserved. No part of this document may be copied by any means without written permission from ETS-Lindgren Inc. Trademarks used in this document: The ETS-Lindgren logo is a registered trademark of ETS-Lindgren Inc. Revision Record MANUAL 3816/2 Part # 399198, Rev. C Revision Description Date A Initial Release January, 1999 B Rebrand; added EC Declaration of Conformity July, 2010 C Updated Line Select Switch information July, 2014 ii www.ets-lindgren.com

Table of Contents Notes, Cautions, and Warnings... v 1.0 Introduction... 7 Data... 7 ETS-Lindgren Product Information Bulletin... 8 2.0 Maintenance... 9 Service Procedures... 10 3.0 Specifications... 11 Electrical Specifications... 11 Physical Specifications... 12 4.0 Installation and Application... 13 Front Panel Connectors and Controls... 14 BNC Connector... 14 RF Ground... 14 Earth Line Choke Switch... 14 Artificial Hand... 14 Line Select Switch... 15 Back Panel Connectors... 16 Power Input... 16 RF Ground... 16 5.0 Schematic... 17 Appendix A: Warranty... 19 Appendix B: EC Declaration of Conformity... 21 www.ets-lindgren.com iii

This page intentionally left blank. iv www.ets-lindgren.com

Notes, Cautions, and Warnings Note: Denotes helpful information intended to provide tips for better use of the product. Caution: Denotes a hazard. Failure to follow instructions could result in minor personal injury and/or property damage. Included text gives proper procedures. Warning: Denotes a hazard. Failure to follow instructions could result in SEVERE personal injury and/or property damage. Included text gives proper procedures. See the ETS-Lindgren Product Information Bulletin for safety, regulatory, and other product marking information. www.ets-lindgren.com v

This page intentionally left blank. vi www.ets-lindgren.com

1.0 Introduction The ETS-Lindgren Model 3816/2 Line Impedance Stabilization Network (LISN) is a two-channel low pass filter network designed to isolate the Equipment Under Test from an external power source while steering any radio frequency signals from the power line to a 50-ohm port. Model 3816/2 Front View The conducted emissions measurements may be made in accordance with regulatory compliance standards. Data Characterizations for each measurement port of the Model 3816/2 Line Impedance Stabilization Network (LISN) are included with the unit. The graphs provide individual plots of both impedance and insertion loss data. A Certificate of Calibration Conformance is provided with each Model 3816/2. www.ets-lindgren.com Introduction 7

ETS-Lindgren Product Information Bulletin See the ETS-Lindgren Product Information Bulletin included with your shipment for the following: Warranty information Safety, regulatory, and other product marking information Steps to receive your shipment Steps to return a component for service ETS-Lindgren calibration service ETS-Lindgren contact information 8 Introduction www.ets-lindgren.com

2.0 Maintenance Only trained service personnel should perform adjustments and/or service procedures. Inside the Model 3816/2 are LETHAL voltages with which you could come into contact. Capacitors inside the unit may still be CHARGED even when the unit is disconnected from power. Before performing any maintenance, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. WARRANTY Maintenance of the Model 3816/2 is limited to external components such as cables or connectors. Clean the exterior of the cabinet using a damp cloth and mild cleaner. Always unplug the unit before cleaning. To prevent electrical shock, do not remove cover. If you have any questions concerning maintenance, contact ETS-Lindgren Customer Service. www.ets-lindgren.com Maintenance 9

Service Procedures For the steps to return a system or system component to ETS-Lindgren for service, see the Product Information Bulletin included with your shipment. 10 Maintenance www.ets-lindgren.com

3.0 Specifications Electrical Specifications Frequency Range: 9 khz 30 MHz (VDE 0876 specified curve ± 20% Network Inductance: 50 µh / 250 µh Network Impedance: Power Line Frequency: Maximum Current: 50 Ω DC: 60 Hz 15 (16) amperes (as supplied) Maximum Voltage Line-to-Line Line-to-Ground 460 volts AC RMS 250 volts AC RMS Maximum AC Voltage 3810/2NM: 3810/2BR: 3810/2SH: 3810/2AS: 125 VAC 60 Hz 250 VAC 50 Hz 250 VAC 50 Hz 250 VAC 50 Hz Output Connectors 3810/2NM: NEMA 5-15R 3810/2BR: British BS1363 3810/2SH: Schuko CEE 7/7 3810/2AS: AS 3112 Input Connector: IEC-320 Type 3-wire Inlet www.ets-lindgren.com Specifications 11

Environmental Installation: Altitude: Temperature: Relative Humidity: Indoor use only 15000 ft (4572 m) max 0 C to 40 C (32 F to 104 F) 80% up to 31 C (87.8 F) decreasing linearly to 50% at 40 C (104 F) Physical Specifications Height: Width: Depth: Weight: 124 mm (4.9 in) 218 mm (8.6 in) 381 mm (15.0 in) 5.4 kg (12.0 lb) 12 Specifications www.ets-lindgren.com

4.0 Installation and Application Before connecting any components, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. The Model 3816/2 is provided with resistors to help bleed off high voltage transients, but it is advisable to connect the input and output connectors to their proper power lines and loads before connecting the monitor port to the measurement instrumentation; otherwise, power surges or transients can damage the test instrumentation mixers or attenuators. The Model 3816/2 Line Impedance Stabilization Network (LISN) is nominally designed for a 15-ampere current capacity, this rating may be increased to 16 amperes provided that the input and output connections are configured for these currents. Maximum line-to-line voltage must not exceed the 460 volts AC RMS. Maximum line-to-ground voltage must not exceed 250 volts AC RMS. The safety ground should be connected first and disconnected last on the input side of the unit. An RF ground stud is provided on the front panel and rear panel for bonding to the ground plane. www.ets-lindgren.com Installation and Application 13

The input power connection is made through a three-wire power cord utilizing the accepted international color code. The input power cord opening is sized to accept a standard electrical conduit fitting or strain relief (supplied). An internally-mounted terminal strip provides the input connection point. When connecting the conduit, disconnect the power cord from the terminal strip and remove it. Front Panel Connectors and Controls BNC CONNECTOR Connect the Model 3816/2 to the spectrum analyzer or EMI receiver through the BNC connector. RF GROUND The Model 3816/2 is provided with an RF bonding stud on both the front and rear panels. The unit should be bonded to a ground plane in normal operation. EARTH LINE CHOKE SWITCH The safety ground isolation choke selector switch switches the 1.6 mh earth line choke IN and OUT of the safety ground circuit. The ground choke is designed and manufactured with sufficient capacity to conduct the maximum current rating of the Model 3816/2 and at no time is the safety ground of the unit compromised. The earth line choke avoids a double RF ground connection (safety ground and measurement ground) in the conducted emissions test setup. ARTIFICIAL HAND In conformance with EN55014 and BS800, the artificial hand connection is used to test handheld equipment that is provided without earth connections. 14 Installation and Application www.ets-lindgren.com

LINE SELECT SWITCH Select the line to be monitored by the three-position selector switch. The line not selected is internally terminated into 50 ohms. When using the remote (center) position, connect the monitored line to the 9-pin connector on the rear panel. Control signals are low-level 5 volt DC. To monitor Line L1, apply +5VDC to pin 1 of the 9-pin connector. To monitor L2, apply +5VDC to pin 3. Should +5VDC be applied to both pins, the first pin to receive the control signal will be selected. As with manual selection, the line not selected is terminated into 50 Ω. Pin 2 of the 9-pin connector is control common. Although the unit is provided with resistors to help bleed off high voltage transients, connect the input and output connectors to their proper power lines and loads before connecting the monitor port to the measurement instrument. Otherwise, you may damage the mixers or attenuators of the test instrumentation due to power surges or transients. Switching between the two lines will not generate transients. Remove the power source first when disconnecting power. www.ets-lindgren.com Installation and Application 15

Back Panel Connectors POWER INPUT The input power connection is made through a jacketed three-conductor power cable. This three-conductor power cable is rated at 16 amperes maximum. In case of emergency, power can be removed from the unit by disconnecting the Model 3816/2 input power plug from the power mains. Alternately, a properly rated circuit breaker or switch which removes mains power from the unit can be installed in proximity to the unit. RF GROUND See description on page 14. 16 Installation and Application www.ets-lindgren.com

5.0 Schematic Resistance values shown in ohms. Ground choke select switch (S1) shown in the IN position. Line monitor select switch (S2) shown in the L2 (NTL) position. NEMA type output connector shown. www.ets-lindgren.com Schematic 17

18 Schematic www.ets-lindgren.com

Appendix A: Warranty See the Product Information Bulletin included with your shipment for the complete ETS-Lindgren warranty for your Model 3816/2. DURATION OF WARRANTIES FOR MODEL 3816/2 All product warranties, except the warranty of title, and all remedies for warranty failures are limited to two years. Product Warranted Model 3816/2 Line Impedance Stabilization Network (LISN) Duration of Warranty Period 2 Years www.ets-lindgren.com Warranty 19

This page intentionally left blank. 20 Warranty www.ets-lindgren.com

Appendix B: EC Declaration of Conformity www.ets-lindgren.com EC Declaration of Conformity 21