Service & Support. Replacing the Parent Hardware Module with the Successor Hardware Module (Migration) CP443-1 (Advanced) FAQ July 2012

Similar documents
Cover. IP Address Assignment Using Primary Setup Tool (PST) Electrical Lean Switch. FAQ June Service & Support. Answers for industry.

SIMATIC NET. S7 CPs for Industrial Ethernet CP Version 3 or later (Firmware version V2.2) for SIMATIC S LED displays.

Setting up a secure VPN Connection between SCALANCE S and CP x43-1 Adv. Using a static IP Address. SCALANCE S, CP Advanced, CP Advanced

Setting up a secure VPN Connection between CP x43-1 Adv. and SOFTNET Security Client Using a static IP Address

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

FAQ about communication via IE

FAQ Communication over IE

FAQ about S7 communication via IE

1 What's new in SIMATIC imap STEP 7 AddOn?

Upgrade instructions for the SIMOTION I-Device (PROFINET) SIMOTION V4.1 V4.2 or higher. FAQ March Service & Support. Answers for industry.

Supplementary Components Network transitions

Service & Support. Data Communication between S7 Station and PC Station, using SIMATIC NET OPC Server SIMATIC S7. Function description March 2013

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Service & Support. MODBUS/TCP Communication over Integrated PROFINET Interface of S7-300 and S7-400 CPU. Modbus/TCP PN CPU.

Connecting a PC Station to an S using OPC

CP ADVANCED. Function

Applications & Tools. Communication between WinAC MP and a SIMATIC S7. Application for the PUT and GET Function Blocks of the S7 Communication

How Do You Replace a CPU 41x with the CPU 410-5H Process Automation? SIMATIC PCS 7 FAQ 01/2016

CP BACNET Function

Setting up a secure VPN Connection between CP x43-1 Adv. and M812-1 Using a static IP Address

Application on Communication

1 What's new in SIMATIC imap STEP 7 AddOn?

Service & Support. How can you transfer a WinCC (TIA Portal) project to an operator panel using Ethernet? WinCC (TIA Portal) FAQ February 2012

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

SIMATIC NET. S7-CPs for Industrial Ethernet CP Manual Part B3S. Release 02/2006 C79000 G8976 C201 03

Siemens Spares SIMATIC NET. Industrial Remote Communication - TeleControl TeleControl Server Basic. Preface. Application and functions

Short Description. Version

TeleService of a S station via mobile network

Supplementary Components WirelessHART products

How-To-Do. EtherCAT Communication with CPU 300S

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

SIMATIC NET. S7-CPs for Industrial Ethernet. CP Advanced. Manual Part B4A. Release 01/2007 C79000-G8976-C193-06


SIMATIC NET. S7-CPs for Industrial Ethernet CP IT / CP IT GX20. Version 1 and higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

FAQ Communication via IE

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

SIMATIC NET. Industrial Remote Communication TeleService TS Gateway. Preface. Application and properties. Installation, commissioning and operation 2

FAQ about Drive Technology

Accessing SINAMICS parameters via OPC server

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

FAQ about communication via IE

Table of Contents. Table of Contents

Cover sheet. Help for Planning Plants with PCS 7 OPC DA SIMATIC PCS 7 OPC DA. FAQ March Service & Support. Answers for industry.

FAQ about Communication

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Process automation with the SIMATIC PCS 7 CPU 410-5H controller

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support


SIMIT. Notes on Installation and Usage. Software disclaimer for simulation products. Security information

SIMATIC. Process Control System PCS 7 V7.0 SP1 Software Update With Utilization of New Functions (PCS 7 V6.x to V7.0 SP1) Preface.

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

Setting up a secure VPN connection between two SCALANCE S Modules Using a static IP Address

Service & Support. How do you create a communication of with an Industrial Thin Client SIMATIC ITC? Thin Client.

TIM DNP3 SIMATIC NET. Industrial Remote Communication - Telecontrol TIM DNP3. Preface. Uses and properties of the TIM

SIMATIC S Central processing units

SCE Training Curriculum


Application for Communication

CP Advanced (GX30) SIMATIC NET. S Industrial Ethernet CP Advanced (GX30) Preface. Properties and services 1. Performance data 2

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS.

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

Application for Process Automation

Application for Process Automation

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

Applications & Tools. Configuring RT communication between SIMATIC and SIMOTION (I-Device) SIMATIC & SIMOTION. Application Example June 2012

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

Department PAC-P3. Department PAC-P3. C h a n g e s. 1.0 (10)10A010 - initial version Müller Müller

FAQ Communication over PROFIBUS

SIMATIC NET CP Produktinformation Product Information Information produit Informazioni sul prodotto Información sobre producto

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

FAQ Communication over PROFIBUS


Setting up a secure VPN Connection between SCALANCE S and SSC Using a static IP Address. SCALANCE S, SOFTNET Security Client

Service & Support. How do I configure extended PROFIsafe on the CU240E-2?

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.


SCE Training Curriculum for the end-to-end automation solution Totally Integrated Automation (TIA)

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)


Operating system update with ProSave. ProSave. FAQ July Service & Support. Answers for industry.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

SIMATIC. Process Control System PCS 7 Getting Started Part 1. Preface, Contents. Requirements for Getting Started 1.

SIMATIC. PCS 7 process control system PCS 7 SMART (V9.0) Security information 1. Preface 2. System Requirements 3. Licenses 4

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

FAQ Communication over IE

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA)

ProfinetCommander User Manual 3.1 March 2010

SIMATIC PCS 7 Standard Architectures

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information


Applikationen & Tools. FETCH/WRITE service in an S7-300/400 CPU via the integrated Ethernet interface. Fetch/Write function block FB210/220

Applications & Tools. Setup and Configuration of a Redundancy via PRP and HSR SCALANCE X204 RNA, CP RNA, SOFTNET-IE RNA

Applications & Tools. System Architectures With SIMATIC PCS 7/OPEN OS SIMATIC PCS 7. Application Description November Answers for industry.

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

Transcription:

Cover Replacing the Parent Hardware Module with the Successor Hardware Module (Migration) CP443-1 (Advanced) FAQ July 2012 Service & Support Answers for industry.

Question This entry is from the Siemens Industry Online Support. The general terms of use (http://www.siemens.com/terms_of_use) apply. Clicking the link below directly displays the download page of this document. http://support.automation.siemens.com/ww/view/en/34894744 Caution The functions and solutions described in this article confine themselves predominantly to the realization of the automation task. Furthermore, please take into account that corresponding protective measures have to be taken in the context of Industrial Security when connecting your equipment to other parts of the plant, the enterprise network or the internet. Further information can be found in Entry ID 50203404. http://support.automation.siemens.com/ww/view/en/50203404 Question What do you have to watch out for when replacing the parent hardware module with the successor hardware module CP443-1 or CP443-1 Advanced? Answer The instructions and notes listed in this document provide a detailed answer to this question. 2 V2.0, Item ID: 34894744

Table of Contents Table of Contents 1 Introduction... 4 2 Upgrade (Exchange of Function-Compatible Modules)... 5 2.1 Definition... 5 2.2 CP443-1EX30... 5 2.3 CP443-1GX30... 5 2.4 CP443-1EX20... 6 2.5 CP443-1GX20... 6 3 Spare Parts Scenario... 8 3.1 Definition... 8 3.2 CP443-1EX30... 8 3.3 CP443-1GX30... 8 3.4 CP443-1EX20... 9 3.5 CP443-1GX20... 9 3.6 AUI/ITP Cabling... 10 4 Replacing Previous Product with CP443-1EX30 / CP443-1GX30 in the Hardware Configuration... 11 5 Replacing CP443-1EX11 with CP443-1EX20 in the Hardware Configuration... 12 5.1 Replacing CP443-1EX11 with CP443-1EX20 Firmware V1.0 in STEP 7 V5.4 SP3... 12 5.2 Replacing CP443-1EX11 with CP443-1EX20 Firmware V2.0 in STEP 7 V5.4 SP4... 12 6 Special Features When Using PCS 7 Versions Earlier Than V7.1 SP1... 13 7 Downloading Firmware... 14 8 History... 15 V2.0, Item ID: 34894744 3

1 Introduction 1 Introduction This document describes what you have to watch out for when upgrading from previous modules to the successor modules below. CP443-1 (6GK7443-1EX20-0XE0) CP443-1 (6GK7443-1EX30-0XE0) CP443-1 Advanced (6GK7443-1GX20-0XE0) CP443-1 Advanced (6GK7443-1GX30-0XE0) In the following, the Industrial Ethernet CPs will be referred to in their abbreviated forms as below. CP443-1 EX20 CP443-1 EX30 CP443-1 GX20 CP443-1 GX30 4 V2.0, Item ID: 34894744

2 Upgrade (Exchange of Function-Compatible Modules) 2 Upgrade (Exchange of Function-Compatible Modules) 2.1 Definition The case when the modules described here are implemented instead of a previous module insofar the configuration is changed. Here, the CP previously used in the configuration is replaced by the new CP. 2.2 CP443-1EX30 The following previous products can be upgraded to CP443-1 (6GK7443-1EX30-0XE0) firmware version V3.0. CP443-1EX20 CP443-1EX11 with CPUs firmware version 4.1 onwards CP443-1EX10 with CPUs firmware version 4.1 onwards When you upgrade one of the previous products to CP443-1EX30, pay attention to the following: The CP443-1EX30 is released only for CPUs with firmware version V4.1 and higher. The upgrade is not possible when you use a CPU with firmware version V4.0 and lower. You must upgrade CPUs with firmware V4.0 to firmware V4.1. When operating CP443-1EX30 with CPUs version V4.x, all the functions are supported that the CP443-1EX11 provided. Operation as PROFINET IO controller and SEND/RECV connections in the SPEED SEND/RECV mode are not supported. 2.3 CP443-1GX30 The following previous modules can be upgraded to CP443-1 Advanced (6GK7443-1GX30-0XE0) firmware version V3.0. CP443-1EX30 CP443-1EX20 CP443-1GX20 CP443-1EX41 with CPUs firmware version V4.1 onwards CP443-1EX40 with CPUs firmware version V4.1 onwards CP443-1GX11 with CPUs firmware version 4.1 onwards V2.0, Item ID: 34894744 5

2 Upgrade (Exchange of Function-Compatible Modules) When you upgrade one of the previous products to CP443-GX30, pay attention to the following: The CP443-1GX30 is released only for CPUs with firmware version V4.1 and higher. The upgrade is not possible when you use a CPU with firmware version V4.0 and lower. You must upgrade CPUs with firmware V4.0 to firmware V4.1. The modules CP443-1EX30 and CP443-1GX30 cannot be used as spare parts for each other (see chapter 3). However, you can upgrade CP443-1EX30 and CP443-1EX20 with CP443-1GX30 if you change the configuration. 2.4 CP443-1EX20 The following previous products can be upgraded to CP443-1 (6GK7443-1EX20-0XE0) firmware version V2.1. CP443-1EX20 firmware version V2.0 / V1.0 CP443-1EX11 with CPUs firmware version 4.1 onwards CP443-1EX10 with CPUs firmware version 4.1 onwards When you upgrade one of the previous products to CP443-1EX20, pay attention to the following: The CP443-1EX20 is released only for CPUs with firmware version V4.1 and higher. The upgrade is not possible when you use a CPU with firmware version V4.0 and lower. You must upgrade CPUs with firmware V4.0 to firmware V4.1. When operating CP443-1EX20 with CPUs version V4.x, all the functions are supported that the CP443-1EX11 provided. Operation as PROFINET IO controller and SEND/RECV connections in the SPEED SEND/RECV mode are not supported. 2.5 CP443-1GX20 The following previous products can be upgraded to CP443-1 Advanced (6GK7443-1GX20-0XE0) firmware version V2.1. CP443-1EX20 CP443-1GX20 firmware version V2.0 CP443-1EX40 with CPUs firmware version V4.1 onwards CP443-1EX41 with CPUs firmware version V4.1 onwards CP443-1GX11 with CPUs firmware version 4.1 onwards 6 V2.0, Item ID: 34894744

2 Upgrade (Exchange of Function-Compatible Modules) When you upgrade one of the previous products to CP443-1GX20, pay attention to the following: The CP443-1GX20 is released only for CPUs with firmware version V4.1 and higher. The upgrade is not possible when you use a CPU with firmware version V4.0 and lower. You must upgrade CPUs with firmware V4.0 to firmware V4.1. The modules CP443-1EX20 and CP443-1GX20 cannot be used as spare parts for each other (see chapter 3). However, you can upgrade CP443-1EX20 with CP443-1GX20 if you change the configuration. V2.0, Item ID: 34894744 7

3 Spare Parts Scenario 3 Spare Parts Scenario 3.1 Definition The case when an existing module can be replaced by the new module (remove/insert) without changing the configuration. 3.2 CP443-1EX30 The CP443-1 (6GK7443-1EX30-0XE0), firmware version V3.0, can be used as a spare part for the following predecessor products: CP443-1EX20 CP443-1EX11 with CPUs firmware version 4.1 onwards CP443-1EX10 with CPUs firmware version 4.1 onwards You must continue to order CP443-1EX11 as spare part for CPUs with firmware earlier than V4.0. You must upgrade CPUs with firmware V4.0 to firmware V4.1. In the case of H CPUs, you can use CP443-1EX30 as spare part for the CP443-1EX11, even together with H CPUs with firmware version V4.0. In the following chapters of the CP443-1EX30 manual you will find detailed information on replacing previous products with the CP443-1EX30. Replace previous modules: spare parts / upgrading Replace previous modules: CPs with configurable data content The manual is available at the following link: http://support.automation.siemens.com/ww/view/en/59187251 3.3 CP443-1GX30 The CP443-1 Advanced (6GK7443-1GX30-0XE0), firmware version V3.0, can be used as a spare part for the following predecessor products: CP443-1GX20 CP443-1EX41 with CPUs firmware version V4.1 onwards CP443-1GX11 with CPUs firmware version 4.1 onwards You must continue to order CP443-1EX11 or CP443-1EX41 as spare part for CPUs with firmware earlier than V4.0. You must upgrade CPUs with firmware V4.0 to firmware V4.1. 8 V2.0, Item ID: 34894744

3 Spare Parts Scenario In the following chapters of the CP443-1GX30 manual you will find detailed information on replacing previous products with the CP443-1GX30. Replace previous modules: spare parts / upgrading Replace previous modules: CPs with configurable data content The manual is available at the following link: http://support.automation.siemens.com/ww/view/en/59187252 3.4 CP443-1EX20 The CP443-1 (6GK7443-1EX20-0XE0), firmware version V2.1, can be used as a spare part for the following predecessor products: CP443-1EX20 firmware version V2.0 / V1.0 CP443-1EX11 with CPUs firmware version 4.1 onwards CP443-1EX10 with CPUs firmware version 4.1 onwards You must continue to order CP443-1EX11 as spare part for CPUs with firmware earlier than V4.0. You must upgrade CPUs with firmware V4.0 to firmware V4.1. In the case of H CPUs, you can use CP443-1EX20 as spare part for the CP443-1EX11, even together with H CPUs with firmware version V4.0. In the case of CPUs with firmware V4.1 and higher, you can remove the CP443-1EX11 and slot the CP443-1EX20 in replacement without having to change the hardware configuration. In the CP443-1EX20 manual, in the section entitled "Replacing older modules: spares / upgrading", you will find detailed information on replacing previous products with the CP443-1EX20. The manual is available at the following link: http://support.automation.siemens.com/ww/view/en/27013386 3.5 CP443-1GX20 The CP443-1 Advanced (6GK7443-1GX20-0XE0), firmware version V2.1, can be used as a spare part for the following predecessor products: CP443-1EX41 with CPUs firmware version V4.1 onwards CP443-1GX11 with CPUs firmware version 4.1 onwards You must continue to order CP443-1GX11 as spare part for CPUs with firmware earlier than V4.0. You must upgrade CPUs with firmware V4.0 to firmware V4.1. V2.0, Item ID: 34894744 9

3 Spare Parts Scenario In the CP443-1GX20 manual, in the section entitled "Replacing older modules: spares / upgrading", you will find detailed information on replacing previous products with the CP443-1GX20. The manual is available at the following link: http://support.automation.siemens.com/ww/view/en/28011203 3.6 AUI/ITP Cabling The following Industrial Ethernet CPs no longer have an AUI/ITP interface: CP443-1EX30 CP443-1EX20 CP443-1GX30 CP443-1GX20 If you used the AUI/ITP interface with the previous product, you can use the following AUI or ITP cabling method when replacing with the above-mentioned Industrial Ethernet CPs. AUI cabling Use a SCALANCE X101-1 AUI media converter (6GK5101-1BX00-2AA3) and the IE TP Cord RJ45/RJ45 0.5m (6XV1870-3QE50), for example. ITP cabling with RJ45 partner You can use the following cables to connect terminals with RJ45 interface to the ITP cabling system. Table 3-1 Cable Length Order number IE TP Converter Cord 15/RJ45 0.5m 6XV1850-2EE50 IE TP Converter Cord 15/RJ45 1m 6XV1850-2EH50 These cables are prefabricated with an RJ45 male connector and 15-pin Sub-D female connector. ITP cabling with a partner with 9-pin Sub-D female connector You can use the cable IE TP Cord 9/RJ45 10m (6XV1 850-2JN10), for example, to connect the above-mentioned Industrial Ethernet CPs to a partner with 9-pin Sub-D female connector. These cables are prefabricated with an RJ45 male connector and 9-pin Sub-D female connector. 10 V2.0, Item ID: 34894744

4 Replacing Previous Product with CP443-1EX30 / CP443-1GX30 in the Hardware Configuration 4 Replacing Previous Product with CP443-1EX30 / CP443-1GX30 in the Hardware Configuration Replace previous product with CP443-1EX30 The CP443-1EX30 can be configured as CP443-1EX30 with full range of functions as from STEP 7 V5.5 SP2 HF1 plus Hardware Support Package (HSP 1053). In STEP 7 Professional V11, the CP443-1EX30 can be configured as CP443-1EX20 with its range of functions. You can download the Service Pack 2 (SP2) for STEP 7 V5.5 in this entry: http://support.automation.siemens.com/ww/view/en/57026339 You can download the Hotfix 1 (HF1) for STEP 7 V5.5 SP2 in this entry: http://support.automation.siemens.com/ww/view/en/59216386 The Hardware Support Package is on the DVD included in the CP443-1EX30 delivery package. When due upgrading or installing a spare part in STEP 7 you replace the configured CP with CP443-1EX30, then the configured connections and data are applied as soon as drag the CP443-1EX30 from the hardware catalog and drop it on the module to be replaced in the hardware configuration. Replace previous product with CP443-1GX30 The CP443-1GX30 can be configured as CP443-1GX30 with full range of functions as from STEP 7 V5.5 SP2 HF1 plus Hardware Support Package (HSP 1054). In STEP 7 Professional V11, the CP443-1GX30 can be configured as CP443-1GX20 with its range of functions. You can download the Service Pack 2 (SP2) for STEP 7 V5.5 in this entry: http://support.automation.siemens.com/ww/view/en/57026339 You can download the Hotfix 1 (HF1) for STEP 7 V5.5 SP2 in this entry: http://support.automation.siemens.com/ww/view/en/59216386 The Hardware Support Package is on the DVD included in the CP443-1GX30 delivery package. When due upgrading or installing a spare part in STEP 7 you replace the configured CP with CP443-1GX30, then the configured connections and data are applied as soon as drag the CP443-1GX30 from the hardware catalog and drop it on the module to be replaced in the hardware configuration. V2.0, Item ID: 34894744 11

5 Replacing CP443-1EX11 with CP443-1EX20 in the Hardware Configuration 5 Replacing CP443-1EX11 with CP443-1EX20 in the Hardware Configuration 5.1 Replacing CP443-1EX11 with CP443-1EX20 Firmware V1.0 in STEP 7 V5.4 SP3 As from STEP 7 V5.4 SP3 plus Hardware Support Package (HSP), you can configure the CP443-1EX20 V1.0 as CP443-1EX20. The Hardware Support Package is available for downloading in this entry: http://support.automation.siemens.com/ww/view/en/23183356 If you replace the CP443-1EX11 with a CP443-1EX20 V1.0 in the Hardware Configuration, the following parameters are not transferred automatically: The configured MAC address, IP address and subnet mask. The information about which network the module is connected to. The fixed settings of the Ethernet ports for "Transfer medium / Duplex". Connection information of the S7 connections in NetPro. You must enter these parameters manually in the project. The following parameters are retained: Time interval for the keep-alive signal. Activated H profile. Activated IP access protection with the IP addresses entered. Connection information of the SEND/RECEIVE connections in NetPro. 5.2 Replacing CP443-1EX11 with CP443-1EX20 Firmware V2.0 in STEP 7 V5.4 SP4 You require STEP 7 V5.4 SP4 or higher for configuring the full scope of functions of the CP443-1EX20 V2.0. The full scope of functions of the CP443-1EX20 V2.0 is only available with CPUs with firmware version V5.2 or higher. If you upgrade or you replace the CP443-1EX11 with a CP443-1EX20 V2.0 in the Hardware Configuration, the following parameters are not transferred automatically and must be set manually: The fixed settings of the Ethernet ports for "Transfer medium / Duplex". 12 V2.0, Item ID: 34894744

6 Special Features When Using PCS 7 Versions Earlier Than V7.1 SP1 6 Special Features When Using PCS 7 Versions Earlier Than V7.1 SP1 System configuration On the Engineering Station (ES) a PCS 7 version earlier than V7.1 SP1 and a CP1613 A2 are used. Set the S7 online access point to CP1613 on the Engineering Station (ES) to access the AS from the ES over the CP443-1. If you use a CP443-1EX11 in the AS, then you can unrestrictedly use the "Accessible Nodes" and "Edit Ethernet Users" functions in the SIMATIC Manager to access the CP443-1EX11. If you use a CP443-1EX20 in the AS, then this is not displayed in the SIMATIC Manager by means of the "Accessible Nodes" and "Edit Ethernet Users" functions. Background CP443-1EX11 supports the CD7 protocol. CP443-1EX20 supports the DCP protocol. The drivers of the CP1613 A2 of the SIMATIC NET PC software integrated in a version of PCS 7 earlier than V7.1 SP1 only support the CD7 protocol and not the DCP protocol. Both the CD7 and the DCP protocol will be supported as from PCS 7 V7.1 SP1 with SIMATIC NET PC software V7.1 SP2 HF4. Remedy You have the following option to use the "Accessible Nodes" and "Edit Ethernet Users" functions in the SIMATIC Manager to display the CP443-1. Upgrade the PCS 7 to at least version PCS 7 V7.1 SP1. V2.0, Item ID: 34894744 13

7 Downloading Firmware 7 Downloading Firmware The following Industrial Ethernet CPs no longer have a mode selector: CP443-1EX20 CP443-1EX30 CP443-1GX20 CP443-1GX30 You can download the firmware when the CPU and CP are in RUN mode. No handling is necessary. The following entry provides you with information on how to download firmware. http://support.automation.siemens.com/ww/view/en/12213669 14 V2.0, Item ID: 34894744

8 History 8 History Table 8-1 Version Date Change V 1.0 15.06.2009 First edition V 1.1 09.07.2009 Definition extended for upgrading and spare parts replacement V 1.2 06.08.2009 on downloading the HSP added in section 4.1 V1.3 21.04.2010 Chapter 5 "Special Features When Using PCS 7 Versions Earlier Than V7.1 SP1" added V1.4 02.07.2010 Corrections to Chapter 5 "Special Features When Using PCS 7 Versions Earlier Than V7.1 SP1" V2.0 01.07.2012 Document extended for CP443-1EX30 and CP443-1GX30 V2.0, Item ID: 34894744 15