Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

Similar documents
Assembly Instructions

WorkZone. Desking System. Beautifully designed Highly adaptable Surprisingly affordable. Desking solutions for dynamic environments.

PRODUCT SPECIFICATIONS Pillar Table

Power/Data Instructions. Genius. Movable Walls. September

KI WIREWORKS WIRE ELECTRICAL SYSTEM INTRODUCTION INFORMATION

ALLOY BENCHING PRODUCT SPECIFICATIONS

DOCKING STATION SPECIFICATIONS

T A B L E O F C O N T E N T S

January 3, 2011 Updated January 2,

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

Haworth Power Technical Sheets January 2018

Morrison, Currents and Reff Raceways Morrison, Currents and Reff Raceways

PRODUCT PRICING GUIDE US & Canada

dewey statement of line

lighting, electrics & communications

Powered Tables Price List. July 24, 2006 Updated October 24,

Electrical Accessories

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Rumble Seat and Hoodie

Pricing & Specification Guide United States April 1, 2018

Trig Planning Guide. December 2012

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com

lighting, electrics & communications

Emerald Cubicle System. Spec Sheet. Emerald 39,52, 65 H. skutchi.com cubicles.cc. Vol DESIGNS. inc.

DESCRIPTION PRODUCT CODE LIST PRICE DIMENSIONS/INCHES H L D

Product Profile. Links to PROJECT PHOTOS & OPTIONS ALBUMS Inside COMPLETE CONSOLE FURNITURE SOLUTIONS MODULAR UNIT DESIGN CUSTOM COLORS

XSEDE HEIGHT ADJUST. Table of Contents. Xsede Height Adjust Kimball Benching. Price List Effective Dates: Pricing Revision

MERIT SERIES. For Today's Sensible Buyer MANUFACTURED IN THE USA

FOUNDATION DESKS FOUNDATION. Foundation Executive Workstation.

Power Base AI. Power Base AI. Technical Sheets

lighting, electrics & communications

U-SERIES SPECIFICATION GUIDE

Smartspace Benching System

Flex Insight Desk. Technical Specifications. Color Options. 36 W x 24 D Single desk. 42 W x 30 D Single ADA desk. 36 W x 30 D Single desk

lighting, electrics & communications

XSEDE POWER BEAMS and PANELS

TechCart Mobile furniture designed for a wide variety of work environments

AnthroCart 2. Our Most Popular AnthroCart2 Features. Anthro Only Gets Better With Age! Strong. Flexible. Easy to Assemble. Mobile.

electrics PRODUCT MAP / TABLE OF CONTENTS ELECTRICS & COMMUNICATIONS OVERVIEW POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS..

T A B L E O F C O N T E N T S

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

lighting, electrics & communications

P R O D U C T C A T A L O G

E-SOC CONTROL STATION. TEL: WEB: winsted.com

STORAGE & ACCESSORIES

TechCart TM. quality mobile furnishings designed for a wide variety of work environments

Flexstation WASHINGTON STATE CORRECTIONAL INDUSTRIES

ViewPoint Monitoring Console System

RDM Industrial Products Inc.

CNC Tool Storage Solutions

Care Exchange. Workstations

Flex Insight Desk. Technical Specifications. Color Options. with lock(s)

CNC Tool Storage Solutions

ACCESSORIES price list effective January 1, 2018

LapTop Cart Owner s Manual

EDUCATION & TRAINING. Engaged in Teaching & Learning MANUFACTURED IN THE USA

SM (SURFACE MOUNTED) WIREWAY: I SERIES

Information Technology. Furniture

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

Vertiv VR Rack 1.0 GENERAL

Passage Desking System

ACCESSORIES ACCESSORIES ACCESSORIES NATIONAL OFFICE FURNITURE TABLES 519

lighting, electrics & communications

WORKCENTER ACCESSORIES

VTC Series. features: specifications: options: video cart. what great systems are built on.

Modular Workstations. Dimension 4 : Your Smart Choice for Versatile and Adaptable Workstations. Building Blocks for Infinite Productivity Solutions

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

The Solid Wood Standing Desk that Hides your Wires and Cables

Two Circuit Track Power System IS24 / IS26 / IS28

Sovella Concept Workstation. Solutions A to Z DEDICATED TO HUMAN WORKSPACE.

GSA Powered Tables Price List. May 2, 2011 Updated June 10,

ACCESSORIES BROCHURE

UPLIFT 2-Leg Height Adjustable Standing Desk (Version v4 Control Box)

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Electrak quick fit floor service outlet boxes

ALL-FLEX ELECTRIC TABLE BASE

Elements of the educational environment. Computer Lab.

For (2) Single Receptacles: dia. Hole Standard Depth

PRESTIGE SIGHT-LINE CONSOLES PRESTIGE. Sight line

LD Series. features: options: specifications: monitoring / command desk. what great systems are built on.

TV & Office Solutions by equip solutions with a high value of benefit

Model 7416LED

PRODUCT FEATURES AND HIGHLIGHTS

electrical evolvefurnituregroup.com 125

25DTP412 12'5" Tele-Powr Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

PRESTIGE ASCEND CONSOLES PRESTIGE

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Media Director V2 Lectern

Updated Pricing and Content as of July 1, 2018

CONSOLE FURNITURE OPTIONS

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

BUSINESS FURNITURE PARTS LIST & SPECIFICATIONS EFFECTIVE: JANUARY 1, 2012

POKE-THRU FINISHES. Black Painted Flange with Nonmetallic Black Cover. Brass Flange with Nonmetallic Brass Cover. Brass Painted Flange and Cover

Meter Enclosure and Equipment Standards

25DTP4DG Tele Power Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

MODEL 3312 LED

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

Sit-Stand Monitor Arm

CI/SfB 62 (x) Publication No Quick Fit Floor Service Outlet Boxes & Grommets

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories

Transcription:

Flat Screen Garage Table System Planning Guide ORKING FOR YOU

Introduction Bring a new level of performance to any room with KI s Flat Screen Garage. This versatile system does double duty to make the most of your time and space. The Flat Screen Garage is designed to save time. hen you need high-tech access, just press the button...the work surface transforms into a computing center in seconds. The motorized lift conveniently opens the security door, and raises the flat screen display. Another touch lowers it until it s needed again. So whether it s used in training areas, resource centers, or meeting rooms, it will make every second a productive one. The Flat Screen Garage brings a new level of flexibility to any area. A multiple-use table means people can use a room for a variety of applications, to maximize its efficiency. Designed with durability in mind, the Flat Screen Garage easily handles the rigorous challenges posed by educational, training and other multiple-user environments. Valuable equipment remains locked and safe until it s needed again. ith the help of this Planning Guide, you can provide solutions to meet your client s needs. Figure 1 Rectangular worksurface End-of-run/left beam assembly Middle beam assembly "C" leg (shared) "C" leg End-of-run/right beam assembly

1 Table of Contents Privacy screens orksurface Planning...............2 BASIC ORKSURFACE CONSTRUCTION..2 ORKSURFACES...............3 Beam Planning......................7 Leg Planning........................8 Electrical Planning..................10 Divider and Privacy Screen Planning....14 Accessories Planning................16 Flat Screen Garage Planning Review.....17 Flat Screen Garage Specifications......18 Middle divider screen End divider screen Rectangular worksurface Grommet Stand alone beam assembly "C" leg

2 orksurface Planning BASIC ORKSURFACE CONSTRUCTION orizontal worksurfaces are constructed of 1 1 /8" thick 45# density particleboard with.030 thick high-pressure laminate and.030 thick high-pressure backing sheet. Post-formed (PL) edge worksurfaces have elliptical front edge. Rear and side edges are covered in matching flat.024" PVC edge banding. Urethane (ME) edge worksurfaces have elliptical molded front edge. Rear and side edges molded in 1 /4" flat urethane (Figure 2). orksurfaces have one or two cutouts, which accept Flat Screen Garage unit(s). Garage units included in price of worksurface. Door edges are sealed and painted black. A single grommet or PowerUp module may be placed in most worksurfaces. Grommets are standard 5 3 /4" x 2 1 /4" and have a flip-up receding door. Grommets are the same size as PowerUp modules to allow for retrofitting. The grommet or PowerUp will be placed in the upper left corner above the beam for worksurface widths of 42", 48" and 54", centered between the doors above the beam for 66" and 72" double units. Each worksurface has threaded steel inserts for the attachment of legs to the worksurface. The 60", 66" and 72" wide worksurfaces have threaded inserts for the attachment of middle dividers. orksurfaces with PowerUp Modules A PowerUp module can be specified in place of any grommet. The length of the cord on the PowerUp modules will be determined by the beam type (non-powered beam applications will receive a 108" cord; powered beam applications will receive a 22" cord). ADA Tables Single unit ADA tables may be ordered. Specify a 32" deep worksurface, ADA legs with casters, and a non-powered beam of chosen width. Finished height with casters, 32". Knee clearance with 32" deep worksurface, 19". ME edge not available on ADA tables. Figure 2.030" high-pressure laminate top 1-1/4" overall.030" high-pressure backer Flat PVC side and rear edge Elliptical post-formed laminate edge.030" high-pressure laminate top 1-1/4" overall.030" high-pressure backer 1/4" molded urethane side and rear edge Molded urethane edge

3 ORKSURFACES Rectangular post-formed laminate worksurfaces are available in the following sizes: Single unit size with Single unit size with Single unit ADA top with Single Unit ADA top with no grommet grommet (optional) no grommet grommet (optional) 30" Deep x 36" ide 30" Deep x 42", 48", 54" ide 32" Deep x 36" ide 32" Deep x 42", 48", 54" ide D D D D Double unit size with Double unit size with no grommet grommet (optional) 30" Deep x 60" ide 30" Deep x 66" or 72" ide D D Rectangular urethane edge worksurfaces are available in the following sizes: Single unit size with Single unit size with no grommet grommet (optional) 30" Deep x 36" ide 30" Deep x 42", 48" ide D D Double unit size with Double unit size with no grommet grommet (optional) 30" Deep x 60" ide 30" Deep x 72" ide D D

5 ORKSURFACES Cutout Locations Figure 5 36" ide 5.00" 6.28" 42" ide 48" ide 54 " ide 4.50" 5.00" 4.75" 7.28" 14.28" 17.28" 60" ide 5.00" 6.28" 66" ide 72" ide 5.00" 6.28" 6.28"

6 orksurface Planning ORKSURFACES Underside orksurface Clearance Figure 6 Stand-alone worksurface underside worksurface clearance orksurface width 4.50" orksurface width minus 9.00" = 4.50" available space orksurface width 4.50" orksurface width minus 9.00" = 4.50" available space orksurface depth orksurface depth 17" Clearance on 30" deep table orksurface depth minus 13.00" = available space Single Double Shared worksurfaces underside worksurface clearance 4.50" orksurface width minus 6.50" = available space 2" 2" orksurface width minus 4.00" = available space 2" 2" 4.50".50" 25.50" (30" deep) 25.50" (32" deep) End leg Double Double Shared leg End leg Single

7 Beam Planning BEAM ASSEMBLY The beam, a single piece of formed steel, extends the entire width of the worksurface. The beam allows all cords to be stored within. The front side of the beam is partially covered by the garage and its components with minimum accessibility from the user side. Beams for the Flat Screen Garage must be specified as standalone, left, middle, or right. Standalone beam will be shipped with two end caps; left or right will be shipped with one. Middle beams will not include any end caps. Standalone beams cannot use shared legs. Note: In back-to-back configurations, tables must be completely assembled and IT work completed before moving tables into configuration. Beams are sturctural and attached to table with no accessibility when tables are placed back-to-back. End-of-Run/Stand-Alone Beams End-of-run beams are placed at the ends of a run of worksurfaces. Electrical components for the powered single unit beams contain (1) wireway with (2) duplex receptacles. Double tables come with (2) separate wireways, each containing (2) duplex receptacles. Beam end caps are included on end-of-run and stand-alone beams for left and/or right installation. Middle Beams Middle beams are used in the middle between end-of-run beams. Middle beams have the same features as end-of run beams except they do not include end caps. Figure 7 Middle beam assembly End-of-run/right beam assembly End-of-run/left beam assembly Single units shown

8 Leg Planning SUPPORT LEGS orksurfaces are supported by C legs. Once you have determined the worksurface layout, you can start at one end of the layout and specify the proper leg for the application (Figure 8). All standard legs are available with 1 1 /4" vertical glide adjustment in a 29" height. The C leg is also available 38" high for stand-up applications. Vertical leg tube measures 2" x 5" and is constructed of 14-gauge formed steel. All legs have vertical wire management capabilities. A vertical wireway is standard with each leg. Steel trim and liquid-tight fittings are available for power infeeds at the bottom of any leg. All C legs can be used as either end legs or shared legs. Flat Screen Garage legs are not interchangeable with InTandem C legs. An ADA leg is available, which is provided with 3" casters so as to allow for a finished height of 32". The ADA castered leg can not be ganged with non-castered rows. Figure 8 "C" leg (shared) "C" leg ADA "C" Leg with 3" casters

9 C Legs The C leg can be used as either an end leg or a shared leg. The C legs have a vertical wireway with an opening for data cables to enter from the floor. A separate cover for entry of the power infeed is included with the power infeed kit. Power and data cannot be run up the same leg. Figure 8 Back (Instructor) Side of Leg 1.375".875" Dia. 2.125" 3.625" 3.750" ireway cover for data cable entry (included on all legs) ireway cover showing power infeed location orksurface Clearance 30" orksurface 32" orksurface 17" 9.80" 19" 9.80" 3.875" 5.875" 8" 1" 8" 1" 25.50" 25.50"

10 Electrical Planning FLAT SCREEN GARAGE ELECTRICAL Flat Screen Garage 8-wire electrical installations are simple and fast. Figure 9 shows an application that includes all of the components of the 8-wire power system, the only power system available for Flat Screen Garage Systems. Floor or overhead infeeds supply power to the beams. The beams are specified with power where needed. orksurface-to-worksurface power connectors are specified to continue the power from one beam to another. A general rule for the planning of circuits and infeeds is to plan no more than six dual flat screen garage tables per row on one (4) 20 amp per circuit infeed. Each table would have a #4 receptacle (single, hot, neutral and ground wires) to power the motorized lifts. Each of the three ciruits #1, #2 and #3 (sharing one oversized neutral and a common ground) would be specified to power the CPU s, monitors, etc. on two tables per circuit. Verify electrical requirements with customer. Figure 10 One double unit and two single units shown. End-of-run/right beam - 8 ire Middle beam - 8 ire orksurface-to-orksurface - 8 ire Connector End-of-run/left beam - 8 ire Double Unit Floor Infeed Receptacle

11 Floor Infeeds A floor infeed is available to bring power from the floor to the beam electrical. The 8-wire infeed is pre-wired for attachment to the 8-wire power in the beam. The hard-wired infeed provides conduit for the field installed wires. A removable vertical wire manager attaches to the leg and provides for the conduit entry. Infeeds are specified in sizes to match the heights of the corresponding C legs. It is not possible to run power and data up the same leg (Figure 9). Overhead Infeeds Two types of overhead infeeds are available to bring power and communications cables from the ceiling to the worksurface beam. Both types include a 10' long aluminum pole with separate channels for electrical and data entry. The 8-wire infeed includes pre-wired connectors and flexible steel conduit for attaching to the power in the 8-wire beam. The ceiling feed for hard-wired applications is just the pole for field installation of the electrical. hen specifying the overhead infeed, you must specify the worksurface that will be used for the infeed location. orksurface-to-orksurface 8-ire Connector The worksurface-to-worksurface 8-wire connector is used to transfer power from table-to-table. The 18" long connector plugs into the ends of the distribution harnesses to continue power from beam-to-beam. One connector must be specified for each table-to-table connection. Electrical Strip The electrical strip is an optional source of power for non-powered beams and the freestanding frames with casters. The electrical strip is a surge protected, six outlet,110-volt power strip with a 6' cord and plug.

12 Electrical Planning Receptacles Receptacles are available for accessing the 4-circuits of the 8-wire electrical system. Three of the receptacles are black in color and are available to access circuits 1, 2 or 3. These are convenience circuits and share a common neutral and ground. The fourth receptacle is a dedicated circuit with its own neutral and ground. It is orange for easy identification. Beam Receptacle Requirements Eight-ire Duplex in Beam Length front of beam 36" 2 42" 2 48" 2 54" 2 60" 4 66" 4 72" 4 Y-Block The Y-Block allows power to be distributed from the middle of a table series. One end of the Y-Block plugs into the table s power distribution unit. The other end of the Y-Block has two female connectors one for the 8-wire infeed from the building power source and the other for an 8-wire connector. Infrared Receiver The Infrared Receiver works with and must be ordered with an infrared remote control unit to lock down or unlock a room of tables featuring Flat Screen Garage units. One receiver is attached to each table, and can receive a signal for up to two garage units. Infrared Remote Control Unit The Infrared Remote Control Unit sends locking and unlocking signals to receivers and can also be used to raise and lower multiple units at once.

13 Eight-ire Power Infeed - Floor The eight-wire power infeed shall bring power from the building power source up to the beam electrical via the vertical wire manager on the leg. The floor infeeds are specified in sizes to match the leg height. The infeed is pre-wired for attachment to the eight-wire power in the beam. The infeed includes a vertical wire manager that attaches to the leg with a 7 /8" hole for power entry. The infeed kit includes a 90 degree pulling elbow, a liquid tight connector, and 6 feet of liquid tight conduit enclosing the wires. iring connections to the building power source must be made by a certified electrician. Figure 11 Eight-ire Installation 120/240V Delta Single Phase CIR. 1 CIR. 4I Power Infeed to Building Connections ave a certified electrician hardwire the power infeed to the building power source according to the National Electrical Code and any other applicable local codes. See the chart for proper wiring connection to available power. PINK BLACK ITE#2 GREEN/YELLO GREEN ITE#1 DO NOT USE RED BLUE DEAD METAL Receptacles ires to Gauge of Energized be Used ire Receptacle Black 12 1 hite #1 10 Green 12 Receptacle Red 12 2 hite #1 10 Green 12 120/240V Open Delta Single Phase CIR. 1 PINK BLACK ITE#2 GREEN/YELLO GREEN ITE#1 DO NOT USE RED BLUE CIR. 3 CIR. 4I DEAD METAL Receptacle Blue 12 3 hite #1 10 Green 12 120/240V Single Phase CIR. 1 CIR. 3 CIR. 4I Receptacle Pink 12 4l hite #2 10 Green/Yellow 12 Note: hite #1 has black lettering hite #2 has red lettering PINK BLACK ITE#2 GREEN/YELLO GREEN ITE#1 DO NOT USE RED BLUE CIR. 3 DEAD METAL CONNECTION DIAGRAM Risk of fire or electrical shock. Do not electrically connect table to more than one supply source. Always determine that the table is electrically connected to one and only one source of supply. 120/208V YE Three Phase CIR. 1 PINK BLACK ITE#2 GREEN/YELLO GREEN ITE#1 RED BLUE CIR. 4I DEAD METAL CIR. 3 CIR. 2

14 Divider and Privacy Screen Planning PRIVACY and DIVIDER SCREENS The Flat Screen Garage Table System offers varying degrees of seated privacy with divider and privacy screens. Screens and dividers have.030" thick high-pressure laminate as standard. All edges are banded with PVC edging (Figure 12). Privacy screen brackets are unique to this table. Privacy screens Figure 12 Middle divider screen End divider screen Privacy screens are available in the following sizes: 11" igh x 36", 42", 48", 54" ide 11" igh x 60", 66", 72" ide (Two-piece screen) 17" igh x 36", 42", 48", 54" ide 17" igh x 60", 66", 72" ide (Two-piece screen) 23" igh x 36", 42", 48", 54" ide 23" igh x 60", 66", 72" ide (Two-piece screen)

15 Stand-alone privacy screens are available in the following sizes: 11" igh x 36", 42", 48", 54" ide 11" igh x 60", 66", 72" ide (Two-piece screen) 17" igh x 36", 42", 48", 54" ide 17" igh x 60", 66", 72" ide (Two-piece screen) Divider screens are available in the following sizes: 11" igh x 30" Deep 17" igh x 30" Deep 23" igh x 30" Deep D D D orksurface Privacy Screens orksurface privacy screens offer three levels of privacy; a low screen that is 11" high, a mid-height screen that is 17" high and a high screen that is 23" high. These three heights are not designed to be used together within the same workstation. Privacy screens are available in lengths to match the worksurface widths from 36" to 72" and are 3 /4" thick. 60", 66" and 72" wide screens are made up of two equal size screens. Specify screens based on worksurface width. orksurface privacy screens must be used with divider screens. For standalone applications, specify the stand-alone privacy screens. orksurface Divider Screens orksurface divider screens are used to divide a wide worksurface into two work areas or to separate worksurfaces side-to-side. Divider screens are available in three heights to match the regular privacy screens. Screens must be specified for their location end or middle and can only be used with privacy screens. Divider screens must be the same height as the privacy screens to which they attach. Stand-Alone Privacy Screens Stand-alone privacy screens, for use without divider screens, are available 11" and 17" high and attach to the back underside of rectangular worksurfaces. Screens are available in lengths to match the worksurface widths from 36" to 72" and are 3 /4" thick. 60", 66" and 72" wide screens are made up of two equal size screens. Stand alone privacy screens are not available in 23" height.

16 Accessories Planning CPU Slings The CPU sling attaches under a 30" deep worksurface to provide vertical storage of a CPU with a maximum circumference of 65". The sling provides 5 1 /2" of travel and 359 swivel for easy access to the CPU. The straps, with positive locking clamps, provide a maximum weight capacity of 75 pounds. Note: 60" worksurfaces cannot accommodate the CPU sling plate. A special order must be requested to shorten the CPU track to 11" and replace the mounting hole. Figure 13

17 Flat Screen Garage Planning Review hen specifying a Flat Screen Garage workstation, the following items must be included: 1. orksurface with Flat Screen Garage 2. Beam (Same size as worksurface, powered or unpowered) 3. Legs (Shared legs at worksurface connections) If tables are to be powered with 8-wire electrical system, these three items are required: (along with powered beam - above) 1. Infeed 2. orksurface-to-worksurface 8-wire connectors (at every table joint) 3. Receptacles (2) per Flat Screen Garage unit The following should be considered and reviewed when specifying: Always use the largest worksurface top possible. A 72" wide top is more economical than two 36" tops. If desired, grommets or PowerUps must be specified. One PowerUp or grommet per table is available. PowerUp and grommets not available on all table sizes. PowerUp modules may take the place of grommets. See orksurface Planning section page 2 for PowerUp availability. Beams must be specified separately. Beam length must correspond with worksurface width. Two (2) receptacles should be specified per Flat Screen Garage single table and four (4) receptacles should be specified per dual Flat Screen Garage table. One infeed is recommended per 12 Flat Screen Garage units. See Electrical Planning secion page 10. hen more than one infeed is used per row, worksurface-to worksurface connectors are not used at the power split location. Overhead infeeds cannot be specified on ADA tables. Divider screens cannot be used without privacy screens. If privacy screens are used without dividers, you must specify the Stand-Alone Privacy Screens. Product ships KD (knocked down). Refer to assembly instructions for assembly details.

You make the rules. e make the rest. Of course KI solutions work better for you. They re made for you. No one pays more attention to customer needs than we do. e don t design our furniture to win awards (even though it does). e don t rely on one-size-fits-all solutions (even though they would make our life easier). e find out what the market needs. And, we make it. The same applies to our service, distribution everything we do. KI solutions work, because we re working for you. KI 1330 Bellevue Street P.O. Box 8100 Green Bay, I 54308-8100 1-800-424-2432 www.ki.com KI and orking For You are registered trademarks of Krueger International, Inc. 2007 KI All Rights Reserved. Litho in USA. KI-61885/TMI/PDF/807