Process Historian Administration SIMATIC. Process Historian V8.0 Update 1 Process Historian Administration. Basics 1. Hardware configuration 2

Similar documents
SIMATIC. Process Historian 2014 SP2 SIMATIC Process Historian. Process Historian - Installation Notes 1. Process Historian - Release Notes

Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

Siemens Drives & PLCs

SIMATIC. Information Server 2014 SP2 SIMATIC Information Server. Information Server - Installation Notes 1. Information Server - Release Notes

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

PD PA AP How To Configure Maxum II TimeServer Access

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SFC Visualization (V8.0 SP1) SIMATIC. Process Control System PCS 7 SFC Visualization (V8.0 SP1) What's new in SFV? 1. SFC Visualization (SFV)

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0 Update 1) Security information 1. Preface 2. Basics 3

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC HMI. StoragePlus V1.3 SP1 / PCS 7 V7.1 MDM - Storage Plus Information System. StoragePlus Installation Instructions 1. StoragePlus Readme 2

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Maintenance COMOS. Platform Maintenance. Trademarks 1. Information on version change. Switching the licensing technique

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC. Process Control System PCS 7 Compendium Part D - Operation and Maintenance (V8.2) Security information 1. Preface 2

Optional package printer driver V1.4

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

COMOS. Lifecycle 3D Integration Operation. Publisher 1. COMOS PDMS Integration 2. Material management 3. COMOS 3D viewing 4.

Siemens Automation Products

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Configuration limits for products of the HARDNET-PB DP-Base 1

SIMATIC Industrial PC. Panel Drivers and Tools V1.3 PDT IFP Monitor Standard. Preface. Panel Drivers and Tools software. IPC Configuration Center

COMOS. Lifecycle 3D Integration Operation. COMOS PDMS Integration 1. Material management 2. COMOS 3D viewing 3. References 4.

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

Transcription:

Basics 1 Hardware configuration 2 SIMATIC Process Historian V8.0 Update 1 Management console 3 Process control messages 4 System Manual 04/2012 A5E03916798-02

Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the relevant information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Order number: A5E03916798-02 P 04/2012 Technical data subject to change Copyright Siemens AG 2012. All rights reserved

Table of contents 1 Basics... 5 1.1 Overview...5 1.2 Data structures...7 1.3 Segmentation...11 2 Hardware configuration... 13 3 Management console... 15 3.1 Overview...15 3.2 Process Historian Management dashboard...17 3.3 System structure dashboard...17 3.4 I/O systems dashboard...18 3.5 Diagnostics dashboard...19 3.6 Backup/Restore dashboard...20 3.6.1 Introduction...20 3.6.2 Creating segment backups...21 3.6.3 Restoring a segment...22 3.6.4 Deleting a segment...23 3.7 Configuring compression...24 3.8 Changing segment settings...25 3.9 Licensing dashboard...27 4 Process control messages... 29 System Manual, 04/2012, A5E03916798-02 3

Table of contents 4 System Manual, 04/2012, A5E03916798-02

Basics 1 1.1 Overview Introduction SIMATIC Process Historian is a central archiving system for storing process data, such as process values and messages. The Process Historian uses the Microsoft SQL Server 2008 R2 SP1, 64-bit, and archives historical data that originates from a PCS 7 Operator Station (OS) and SIMATIC Batch. The data can belong to different PCS 7 projects. Access to the historical data is transparent for the OS Clients. Services Process Historian employs four services for processing, storing and backing up data: SIMATIC Process Historian Server This service implements all functions the server needs to process and store data. Process Historian Maintenance Service This service implements all functions that are necessary to maintain the Process Historian database. The Maintenance Service handles tasks such as starting mirroring, mirror monitoring, restore functions, maintenance of the transaction log and suchlike. Process Historian Redundancy Service This service implements functions that are necessary for data exchange between two redundant server systems. Process Historian Discovery Service This service supports the search for connected Process Historian systems. The Discovery Service is essential for the functionality of the Process Historian. System Manual, 04/2012, A5E03916798-02 5

Basics 1.1 Overview Operating states You can use the shortcut menu of the icon in the system tray to switch the Process Historian to the following operating states: Starting Shutting down Starting restore The following table provides an overview of the operating states and the color coding of the associated icons in the system tray: Symbol Process Historian operating state Description Active In the "Active" operating state, the Process Historian archives data. You can query data from the OS Server or Information Server. Restoring Starting restore In the "Restoring" operating state, the Process Historian requests data from an OS Server for a recognized period of inactivity. The preceding and the subsequent operating state is "Active". This operating state starts "Restoring". Stopping restore This operating state terminates "ActiveRecovery" and is an intermediate state between "ActiveRecovery" and "Active". Deactivated Deactivate The Process Historian changes to the "Deactivated" operating state in the case of maintenance tasks where access to the database is limited. The maintenance tasks can include the creation or the backing up/restoring of segments. The system is offline in this operating state. Access via a network is not possible. "Deactivate" is the intermediate state between "Active" and "Deactivated". Error The "Error" operating state occurs when an error has been recognized or when no connection to the SIMATIC Process Historian service exists. Inactive Shutting down No data is archived in the "Inactive" operating state. In this operating state, you can carry out updates and maintenance work on the Process Historian PC or restart the PC. Intermediate state between "Active" and "Inactive" Starting Intermediate state between "Inactive" and "Active" Not defined Initial state for "Inactive" 6 System Manual, 04/2012, A5E03916798-02

Basics 1.2 Data structures 1.2 Data structures Time-variant value sequences The Process Historian operates with time-variant value sequences that include runtime data and configuration data in the form of context information. Each time-variant value sequence is identified by a sequence identifier that references the configuration data and runtime data for a time-variant value sequence. A Process Historian database can contain several time-variant value sequences for which the following properties may be different: Times for values Distances between values Number of values within a time period Data group Most time-variant value sequences are divided into groups in the Process Historian for better parallel processing. Each of these groups refers to a shared cluster of physical sources within the Process Historian and the Process Historian database. This makes for better parallelization of the groups. Time-variant value sequences are always assigned to a fixed data group for a specific point in time. Note You can distribute the data groups among the available hard disks in order to influence the performance and the scaling of the system used. Distribution is carried out using the Wizard when creating the database. System Manual, 04/2012, A5E03916798-02 7

Basics 1.2 Data structures Partition The amount of runtime data of a single time-variant value sequence is unlimited and grows constantly. The entire amount of data that is assigned to an individual time-variant value sequence or group must therefore be divided into several "partitions" using the time axis. A partition includes runtime data for one or several time-variant value sequences that are limited by time values. The limited time values within a certain partition are referred to as "partition limitations". Data groups are divided into partitions using the time axis. The following conditions apply to partitions: Each partition has a high and low limit for the time period. The time limits can be moved as required, but the high time limit must always be higher than the low one. The partitions of a data group should not overlap. It must always be possible to map each existing time value of a data group on an existing partition. There may be no time gaps with undefined partitions. 8 System Manual, 04/2012, A5E03916798-02

Basics 1.2 Data structures Segment of a runtime database A "segment" combines the data partitions of several data groups. System Manual, 04/2012, A5E03916798-02 9

Basics 1.2 Data structures A database segment S consists of the sum of partitions of all data groups that share the same high and low time limits. These groups correspond to the limits of the segment. The difference between the high and low time limit is referred to as the "time period" of the database segment. The time periods of all partitions within a segment must be aligned across all data groups. If there is a partition with the low and high time limits t1 and t2, there must also be a partition with the same time limits for each other data group. The time periods of segments do not have to be identical here. Each segment has a unique segment number. The start segment, the first segment created in a system, has the number 100,000. The segment whose low limit is equal to the high limit of segment n is referred to as segment n+1. The segment whose high limit is equal to the low limit of segment n is referred to as segment n-1. 10 System Manual, 04/2012, A5E03916798-02

Basics 1.3 Segmentation 1.3 Segmentation Introduction The Process Historian can process and manage very large amounts of data. The saved data is split up into segments so that performance is not impaired. Segments are defined by a time period with a high and low time limit. A segment contains the amount of data that was recorded during the defined time period. By default, segments are created with a segment size of one week when the Process Historian database is created. You can change this setting. You can find information on changing segment configurations under Changing segment settings (Page 25). You cannot retroactively reconfigure segments that already contain data. Segmentation configuration You can change the properties of segmentation on the "Segmentation" dashboard as Process Historian administrator. You can make the following settings: Anchor point of segmentation Time period of a segment Number of prepared segments Total number of runtime segments The following table provides an overview of the basic segmentation parameters: Parameter Value Description Anchor point of segmentation Time period of the segment Number of segments Date, time Week, month, quarter, year Prepared segments Total number of runtime segments Start time of the segment Segment size Total number of prepared segments Number of segments not yet archived and still in runtime The Process Historian continuously creates segments with the defined time period. To ensure that the entire period of possible times is covered, there is a high and a low "Catch all" segment. These segments collect all incoming data that lies outside the current runtime segment. The segments are called "Catch-all-upper" (CAU) and "Catch-all-lower" (CAL). The CAL and CAU segments exist permanently. They cannot be deleted, removed or set to offline. System Manual, 04/2012, A5E03916798-02 11

Basics 1.3 Segmentation Anchor point If you change the anchor point, it has to refer to a time after the last time stamp stored in the segment filled last. If you change the segmentation configuration, all segments whose anchor point refers to a time after the new anchor point are deleted. No data is lost when the segments are deleted, as only segments without content are deleted. Note If the last segment of the existing segmentation configuration ends before the anchor point of the new segmentation, an intermediate segment must be created. This intermediate segment starts with the end time of the last segment of the existing segmentation configuration and ends with the start time of the new segmentation configuration. A suitable anchor point is suggested to avoid the need for an intermediate segment. If you reject this suggestion, an intermediate segment is created automatically. If the anchor point of the new segmentation configuration is located before the end time of the segment currently being used and after the last value saved, the end time of the segment currently being used is specified as the new anchor point. A minimum safety time interval is set in the process. The required number of future segments is created according to the new segmentation settings. Segment types and segment statuses In the Process Historian, a distinction is made between segments of the "Runtime" and "Archive" types. Runtime segments are displayed on the "Segmentation" dashboard. They have the following properties: Data in runtime segments can be changed by the Process Historian system at any time Available in the quantity as configured under "Segmentation" Runtime segments cannot be compressed Runtime segments cannot be backed up Archive segments are displayed on the "Backup/Restore" dashboard. Archive segments are compressed or uncompressed, depending on the setting. The status of a segment is classified as "Online" or "Offline". Segments of the "Runtime" type always have the status "Online". Segments of the "Archive" type can have the status "Online" or the status "Offline". You can only read the contents of segments that are online. You cannot read data from archived segments that are offline. In order to read the contents of segments that are offline, you have to restore these segments. Information about restoring a segment is available under Restoring a segment (Page 22). 12 System Manual, 04/2012, A5E03916798-02

Hardware configuration 2 Overview The described hardware configurations refer to the SIMATIC Process Historian and the Information Server. The simple configuration of Process Historian provides a clear overview of the topology. The following figure illustrates a simple configuration: A sufficiently powerful PC system is capable of handling all tasks involved. This configuration is suitable for small-scale installations with corresponding quantity frameworks. System Manual, 04/2012, A5E03916798-02 13

Hardware configuration Hardware example for small quantity frameworks The example applies to a Process Historian computer on IPC base under the following conditions: Data from up to three OS Maximum archiving load of 1,000 values per second We recommend the following hardware equipment in this case: CPU RAM Hard disks Drives Core i7-610e (2C/4T, 2.53 GHz, 4 MB Cache, TB, VT-x, VT-d, EM64-T) 8 GB DDR3 SDRAM (2 x 4 GB), DIMM, ECC, Dual Channel 1 x 100 GB SSD SATA; internal for operating system and software RAID5 (3 x 1 TB, HDD SAS) in removable for transaction log and data frame, hot swap, on front, HW RAID controller PCIe X8 in PCIe X16 slots including battery backup unit (BBU) DVD±RW The described RAID5 system has a size of about 1.8 TB. All SAS hard drives are connected to the hardware RAID controller. The example configuration demonstrates the minimum hardware requirements. CPU performance, work memory, and the I/O systems may have to be expanded, depending on the data volume. Hardware example for larger quantity frameworks The following example describes the configuration of a PRIMERGY TX300 S6 with the following minimum equipment: CPU RAM Hard disk RAID controller Intel Xeon X5660 6C/12T 2.80 GHz 3 x 16 GB DDR3 1 x 300 GB HDD SAS for operating system and programs 1 x 300 GB HDD SAS for transaction log 4 x 900 GB HDD SAS RAID 10 for archive data SAS / 512 MB with BBU expansion The RAM and the number of processors and hard disks can be expanded with this configuration. Storage Area Network (SAN) is supported. 14 System Manual, 04/2012, A5E03916798-02

Management console 3 3.1 Overview The management console is included in the installation of the Process Historian. It is used for diagnostics and configuration of the Process Historian system and is automatically started upon logon. For a manual start, the management console is available under "Start > Programs > Siemens Automation > SIMATIC > Process Historian > Process Historian Management Console". The following table shows the dashboards of the management console and their tasks: Dashboard Process Historian Management Description Display of fundamental hardware indicators and performance indicators for the PC and operating system Display of basic indicators for the status and current activity of the Process Historian Server Display of the license status Changing the operating state System structure Display of connected projects Display of the OS Server systems Display of the PC name I/O systems Display of the available input and output devices Display of the memory space used Detailed information about the load Diagnostics Diagnostic messages of the Process Historian Messages from the event display of the operating system Backup/Restore Display of the segments of the "Archive" type Creating segment backups Restoring backed-up segments Compression Display of the compression state Turning on and turning off the post-compression Configuration of the number of uncompressed archive segments Segmentation Display of the current segmentation setting Changing the segmentation settings Licensing Display of the current license status of server and project System Manual, 04/2012, A5E03916798-02 15

Management console 3.1 Overview Note Process Historian does not archive data If the Process Historian does not archive data, check the MS Message Queuing and the databases. 16 System Manual, 04/2012, A5E03916798-02

Management console 3.2 Process Historian Management dashboard 3.2 Process Historian Management dashboard The "Process Historian Management" dashboard includes information about: Basic indicators for monitoring the PC: Processor utilization Free memory Hard drive utilization Basic indicators on Process Historian: Number of connected data sources Stored tags per second Stored messages per second Operating state of the Process Historian server License status of the Process Historian Changing the operating mode You can change the operating state of the Process Historian on the "Process Historian Management" dashboard. You can choose from the following operating modes: Start Shutting down Starting restore For this purpose, select the respective entry from the drop-down list in the "Process Historian Status" area. 3.3 System structure dashboard The "System structure" dashboard displays all projects that are currently integrated in the system. The following information on the project is displayed when you select a project: Name Type System Manual, 04/2012, A5E03916798-02 17

Management console 3.4 I/O systems dashboard 3.4 I/O systems dashboard The "I/O systems" dashboard displays the entire memory system to which there is read and write access and in which data is archived. The dashboard displays all hard drives integrated in the system. This includes hard drives that do not contain archive data. The "I/O systems" dashboard displays the following information on the storage system: Name and drive letter of the hard drives File system Total storage space Absolute available storage space Free storage space in percent Absolute storage space used The states of the input and output devices are graphically monitored by the system. If you select a drive, you receive the following detailed information on the selected drive: Idle time of the hard drive Average duration per transfer Average length of queue for read access Average length of queue for write access Reading speed in bytes per second Writing speed in bytes per second 18 System Manual, 04/2012, A5E03916798-02

Management console 3.5 Diagnostics dashboard 3.5 Diagnostics dashboard The upper area of the "Diagnostics" dashboard displays the last 1000 diagnostic messages from the Process Historian event log. The event log of the Process Historian contains the following information: Log entry ID Severity of the message Time stamp Name of application domain Process ID Message The lower section of the dashboard includes the last 100 entries from the event log for Windows applications. The following information is displayed: Time stamp Message Category Source System Manual, 04/2012, A5E03916798-02 19

Management console 3.6 Backup/Restore dashboard 3.6 Backup/Restore dashboard 3.6.1 Introduction Backup types The Process Historian saves process values and messages in temporally defined segments. Back up the contents of the Process Historian database correspondingly by segment. When an archive segment is backed up, the runtime data is stored in the backup file. The stored data includes: Process values Messages Configuration data 20 System Manual, 04/2012, A5E03916798-02

Management console 3.6 Backup/Restore dashboard 3.6.2 Creating segment backups Requirement The segment to be backed up has the "Archive" status. Note During backup or restore, the Process Historian switches to the "Deactivated" state up to two times. No runtime data is archived in this operating state. Your access to the database is limited. Procedure 1. Select the "Backup/Restore" dashboard in the navigation of the management console. 2. Select the segment you want to back up in the "Archive segment" area. 3. Click the "Backup" button to launch backup. Note If you activate the "Set segment offline after backup" option, the segment is deleted as soon as the backup has been successfully completed. You cannot access the data of a deleted segment with the "Offline" status until the segment has been restored. 4. Select the storage location for the backup file in the "Backup segment" dialog box that opens. Click "Backup." You can specify further identifiers and descriptions for the backup such as the name or number of the data medium. Result A backup is created and the date of the backup entered. The segment remains in the "Online" status and is not moved. If you have activated the "Set segment offline after backup" option, the selected segments are backed up and moved to the "Restore segment" section. System Manual, 04/2012, A5E03916798-02 21

Management console 3.6 Backup/Restore dashboard 3.6.3 Restoring a segment If you want to access data that is stored in an archived segment, you must restore the respective segments. When restoring a segment, the backup file corresponding to the segment is selected. Note During backup or restore, the Process Historian switches to the "Deactivated" state up to two times. No runtime data is archived in this operating state. Your access to the database is limited. Requirement The corresponding backup file for the segment to be restored is available. The Process Historian is in the "Active" operating state. Procedure 1. Select the "Backup/Restore" dashboard in the navigation of the management console. 2. Select the desired segment in the "Restore segments" section. 3. Click on the "Restore" button. 4. In the "Backup segment" dialog, select the corresponding backup file for the segment that is to be restored. 5. Click "Restore." Result You can access the data of the restored segment from the OS Server, OS Client or the Information Server. 22 System Manual, 04/2012, A5E03916798-02

Management console 3.6 Backup/Restore dashboard 3.6.4 Deleting a segment Requirement There is a valid backup for the segment that is to be deleted. Note You can only use the "Delete" button if a backup of the selected segment has already been created and this segment is marked as "valid". A segment is, for example, marked as "invalid" if additional runtime data for the segment has accumulated after the creation of a backup. In this case, create a backup of the relevant segment again. You can only delete segments individually. Procedure 1. Select the "Backup/Restore" dashboard in the navigation of the management console. 2. Select the segment you want to delete in the "Archive segments" area. 3. Click "Delete". Result The segment is deleted from the database. System Manual, 04/2012, A5E03916798-02 23

Management console 3.7 Configuring compression 3.7 Configuring compression On the "Compression" dashboard, you can see the current compression state as well as the current default number of uncompressed segments contained. The contained uncompressed segments are counted starting from the first archive segment. Note The archive segments are compressed automatically in the background. You can set the number of archive segments that are not to be compressed. The possible compression factor depends on additional influences, such as the number and archiving cycles of the process values. Procedure 1. Select the "Compression" dashboard in the navigation of the management console. 2. Enable the Activate option button. 3. Enter the number of uncompressed segments you want to keep in the "Configuration" area. 4. Click the "Update settings" button. Result The settings for the compression of archive segments have been modified. 24 System Manual, 04/2012, A5E03916798-02

Management console 3.8 Changing segment settings 3.8 Changing segment settings The "Segmentation" dashboard provides an overview of the current segmentation configuration. The segment states are color coded: Segment status Completed runtime segment Current segment Prepared segment Color Gray Green Blue You can modify the configuration of the segmentation in the "Settings" area. The "Database Installation Wizard" supports you during the installation of the Process Historian database. By default, the following presettings are made for the segmentation during installation: Segment size Total number of segments in runtime Number of prepared segments One week Eight Three Depending on the quantity structure, the amount of data per segment can be very large. This applies to all segments in runtime. When the segments are created, the estimated required memory space is reserved. The optimum settings for the segmentation are a compromise between the memory space used and the number of uncompressed data segments to be reserved. The Process Historian database is automatically switched to the "Deactivated" state to allow the segmentation of the Process Historian to be changed. After the settings have been made, the database changes back to the "Active" state automatically. Note The Process Historian database is switched automatically to the "Deactivated" state to allow changes to the segmentation to be carried out. After the settings have been accepted, the database changes back to the "Active" state automatically. System Manual, 04/2012, A5E03916798-02 25

Management console 3.8 Changing segment settings Procedure 1. Select the "Segmentation" dashboard in the navigation of the management console. 2. In the "Number of segments" area, select the required number of segments to be prepared continuously. 3. In the "Number of segments" area, select the required total number of runtime segments. 4. Click the "Accept settings" button. Result Segmentation of the Process Historian is configured. 26 System Manual, 04/2012, A5E03916798-02

Management console 3.9 Licensing dashboard 3.9 Licensing dashboard The "Licensing" dashboard gives you an overview of the licenses used and available in the system. The availability of the Process Historian license is displayed. You also obtain detailed information about the states of the tag licenses: Available Required Free When you select a project, you receive information on the project-specific license states with the following information: Project name Project type Number of tags System Manual, 04/2012, A5E03916798-02 27

Management console 3.9 Licensing dashboard 28 System Manual, 04/2012, A5E03916798-02

Process control messages 4 Overview Process Historian contains process control messages that visualize specific system states. These pre-defined messages only contain information about process control states and do not return process status data. The following table provides an overview of the process control messages generated in Process Historian: Message number Message text 1012500 PHRDY: Start recovery for Process Historian 1012501 PHRDY: Recovery for Process Historian is completed 1012502 PHRDY: Communication with Process Historian is not available 1012503 PHRDY: Communication with Process Historian faulty 1012504 PHRDY: Communication with Process Historian reestablished 1012505 PHRDY: Process Historian Server offline since @1%s@ 1012600 PH: Data memory occupied by @1%d@% 1012601 PH: System out of resources System Manual, 04/2012, A5E03916798-02 29

Process control messages 30 System Manual, 04/2012, A5E03916798-02