AQS (Air Quality System) General Overview

Similar documents
Appendix 5-1: Attachment J.1 Pricing Table -1: IMS Ceiling Loaded Rates at Contractor Site

22ND CENTURY_J1.xls Government Site Hourly Rate

Data Review, Validation and Verification. All data should be considered VALID unless otherwise proven invalid

Working with Data sent to a Computer or Flash Stick

Comparing Apples to Apples: The Importance of a Primary Quality Assurance Organization from EPA s Perspective

CAMNAT CALIFORNIA AIR MONITORING NETWORK ASSESSMENT TOOLS. PQAO Training January 2015

User Guide for OSM users to Record Youth Data on the TSA Template to be Used for Uploading Youth Data to Compass

SPARE CONNECTORS KTM 2014

SPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN

Loop Qualification Bulk Loader

Parts List, Charging Chart, Wiring Diagrams

JUBILEE HOW-TO HANDBOOK

DETAIL SPECIFICATION SHEET

Parts List, Wiring Diagrams

EDI Import Interface Guide

CLASSIFICATION GRADE UNIT STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7

C-SMART Help: Monetary Contributions 3/4/2019 Page 1

CLASSIFICATION GRADE UNIT STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7

BOOK-IT 8.0. SIP2 implementation in the Z39.70 server

OPAL-RT FIU User Guide.

DOI: / Eng

Air Monitoring Directive Chapter 6: Ambient Data Quality


Air Monitoring Directive CHAPTER 6: AMBIENT DATA QUALITY for verification and validation of continuous ambient air quality data

SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information

SOCIAL ACCOUNTABILITY ACCREDITATION SERVICES

Annual Ambient Air Quality Monitoring Report 2015

Cabling a Data Center to TIA-942 Standard

Introduction This manual presents an overview of the Assembly and Test Cost and Price Model and the basic workings of the model.

Machine Vision Systems

ILOC is a suite of three hierarchical software tools. At the core, the Boundary Logic Engine (Losp) provides Boolean minimization of logic function

XLR3-11C (female) NK27-21C-R (female) + NK-AD1-R (barrel extension) NK27-22C-R (male) + NK-AD1-R (barrel extension)

Parts List, Charging Chart, Wiring Diagrams

New Opacity QC Procedures WRBA Conference

The framework of next generation automatic weather station in China

PARTS LIST AX-1200K AX-1200S MODELS SUPER STEAM OVEN CONTENTS

SIMATIC S plus TIA Portal

Parts List, Charging Chart, Wiring Diagrams

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Requirements (QASR) - Chapter 6. HYDRO-METEOROLOGIC and HYDRAULIC MONITORING

TECHNICAL BULLETIN. Thank you for your continued support of Mitsubishi integrated FA software MELSOFT series.

North Carolina Division of Air Quality. Quality Assurance Project Plan Volatile Organic Compounds (VOCs) by TO-15. Section 4.

MUC Archive - FTP Site Statistics. Top 20 Directories Sorted by Disk Space

Project DESIGN AND CONSTRUCTION OF 2000 LIVING UNITS AND PUBLIC BUILDINGS AL-KHOMS AL-MARQAB. Location District Building No PROCEDURE FOR CALIBRATIONS

DOCUMENT HISTORY. Initials Section/s Modified Brief Description of Modifications


DOCUMENT HISTORY. Date Modified. Brief Description of Modifications. Modified

PTVSxP1UP series. 600 W Transient Voltage Suppressor

2004 Gulf Jackson Lease Area, Levy County Quality Assurance/Quality Control (QA/QC) Log


EDI Import Interface Guide (v2)

SCC Inc. TS Series. Technical Instructions. Document No. TS-4000 March 10, TS-CE Combustion Enclosures with LMV5.

FAQ on Real Time Online Data connectivity to APPCB server

SIMATIC S7-200 PRICE LIST

Registry of General-Purpose Concatenated Elements

PRG FIBER OPTIC SYSTEMS

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

NRS STATE DATA QUALITY CHECKLIST

AWS-SCWI. American Welding Society Senior Certified Welding Inspector. Certification Programs for the Year 2018

W52P1J-15-D-0060 [ ] Honeywell CN70GQ5KN00G1A40

NetDMR National Installation. Regulatory Authority User Guide

Air Monitoring FY 2014

Sunset Beach Deluxe Lighted & Music Hardtop Bar w/ 4 stools. Product Code: D71 M20530 KSN: UPC Code: Date of purchase: / /

WHOIS Accuracy Reporting System (ARS): Phase 2 Cycle 1 Results Webinar 12 January ICANN GDD Operations NORC at the University of Chicago

IMPROVE Website Status and Great Things to Come

Time Series Data Management in Air Quality Monitoring. AQE 2013, Telford/UK. Edgar Wetzel, 14 March 2013

Written Event Online Submission Guidelines

SMAJ SERIES 400 Watts Suface Mount Transient Voltage Suppressor SMA/DO-214AC. RoHS. Features

SOP:11:VL:023:02:NIBT PAGE 1 of 9

ekey Error Codes Error Code Short Name Cause Message Resolution

BẢNG GIÁ PLC SIEMENS S7-200 Áp dụng từ 01/11/ Giá chưa bao gồm thuế VAT

Interline Service Agreement (ISA) Repository User Guide

CompTIA Continuing Education (CE) User Guide

The Role of Data Management in Quality Assurance of Ecological Restoration Data

Implementation of a PC-based data-logger software for air pollution monitoring networks

10 x 12 Hardtop with High Quality Audio and Galvalume. Product Code: D71 M20509 KSN: UPC Code: Date of purchase: / /

Staff Report City of Manhattan Beach

Midwest ISO Overview - ATC Customer Meeting. February 26, 2009

ARKANSAS HIGH COST FUND 2013 CARRIER REVENUE REPORT& SELF INVOICE INSTRUCTIONS

ENGINEERING INTEGRITY Asset Integrity & Corrosion Control Consultants

ENGINEERING INTEGRITY Asset Integrity & Corrosion Control Consultants

October Broward County Government Human Services Department. Community Partnerships Division FY2015 Provider Information

Page 1 of 8 Knowledgebase Technote ID # /18/2013

G3 UNIVERSAL GRIPS GRIPS. Internal View. Custom Mounting Adapters Available. Custom Terminations Available

SUB-PANEL SPREADSHEET GUIDE (SUB-PANELUG)

Data Upload and Evaluation Tool (DUET) User Guide

UL TEST REPORT AND PROCEDURE

CS Programming I: Arrays

ANNEX 1 Guidelines to fill DEVOTES Catalogue of Monitoring Networks

Digital Lighting Systems, Inc.

Getting Past the PM P Certification Qualifying Round

FREQUENTLY ASKED QUESTIONS

Appendix D. Lab Accreditations & Certifications. Regional Wet Weather Characterization Program Annual Monitoring Report Year 3

IT Specialist, Associate of Applied Science Outcomes Assessment Implementation Summary. Academic Year

CompTIA Continuing Education (CE) User Guide V13

CIS-331 Exam 2 Spring 2016 Total of 110 Points Version 1

Version certificate sampling

PTVSxS1UR series. 1. Product profile. 400 W Transient Voltage Suppressor. 1.1 General description. 1.2 Features and benefits. 1.

QAM-Q-104 Laboratory Data Entry and Review

DTrade Frequently Asked Questions (FAQs)

Transcription:

AQS (Air Quality System) General Overview CARB PQAO Training January 25, 2017 Jennifer Williams EPA Region 9 1

AQS (Air Quality System) Overview What is AQS? Database that contains: Ambient air pollution data Meteorological data Descriptive information about each monitoring station Data quality assurance /quality control information Who uses AQS? Data is collected and uploaded by: EPA State agencies Local agencies Tribes Data is extracted and used by: State / Local Agencies / Tribes EPA OAQPS (Office of Air Planning and Standards), EPA regional offices Researchers 2

AQS (Air Quality System) Overview What is AQS used for? Used by the Office of Air Planning and Standards (OAQPS) and other AQS users to: Assess air quality Assist in Attainment/Non-attainment designations Evaluate State Implementation Plans for Non- Attainment Areas Perform modeling for permit review analysis Other air quality management functions Who manages AQS? EPA OAQPS 3

AQS (Air Quality System) Overview There are over 17,000 monitors in Region 9 and over 102,000 monitors (including R9) in the country. 4

AQS Submission Requirements All data collected must be submitted to AQS no later than 90 days after the quarter in which the data was collected. When is data due? Oct. Dec. 2016 Mar. 31, 2017 Jan. Mar. 2017 Jun. 30, 2017 Apr. Jun. 2017 Sep. 30, 2017 Jul. Sep. 2017 Dec. 31, 2017 Oct. Dec. 2017 Mar. 31, 2018 When is data certification for 2016 data due? May 1, 2017 5

Data Submission to AQS https://www.epa.gov/sites/production/files/2016-01/loadingfilesaqs.swf 6

Data Submission to AQS AQS Users Guide: https://www.epa.gov/aqs/aqs-users-guide-0 The User Guide is designed to familiarize the user with: The look and feel of AQS Running AQS Batch Loading data Creating and modifying site and monitor descriptive information Generating output information encompassing user data 2016 National Ambient Air Monitoring Conference PowerPoints: https://www.epa.gov/aqs/naam-conference-2016 7

Monitoring Metadata Monitor metadata can be equally important as the ambient concentration data because incorrect metadata may lead to data issues or errors in data interpretation. Examples of important AQS monitor-level metadata fields: Agency roles Method code Parameter occurrence code Required sampling frequency and schedule Sampling period - start/close dates Type / scale / objective / network affiliation Primary monitor / QA collocation Distance to roadway / probe obstruction NAAQS exclusion https://www.epa.gov /aqs/aqs-code-list 8

Maintain Site: How to add a new monitor 9

Maintain Site: How to add a new monitor 10

Updating Monitor Metadata in AQS The Maintain Monitor Form 11

Example : New method installed at site 12

Example : New method installed at site 13

Example : Change Objective 14

AQS Reports AMP 390 Monitor Description Report AMP 430 Data Completeness Report AMP 300 Violation Day Count Report AMP 350NW Raw Data NAAQS Averages Report AMP 350 Raw Data Report AMP 450 QuickLook Report AMP 480 Design Value Report AMP 600 Data Certification Report 15

AMP 390 Monitor Description Report

AMP 350 Raw Data Report

AMP 430 Data Completeness Report

AMP 480 Design Value Report

which AQS report is right for you? Q: What AQS report would you use to find out if a monitor s method code has changed in the past five years? A: The Monitor Description Report AMP 390 20

which AQS report is right for you? Q: What AQS report would you use to find out the percent of PM 10 data that has been reported for a monitor in 2015? A: The Data Completeness Report AMP 430 21

which AQS report is right for you? Q: What AQS report would you use to find out when a QC check was performed on an instrument? A: The Raw Data Report AMP 350 22

Null data codes, qualifier codes and flags Null Data Codes Data is determined to be invalid Null data does count toward completeness AJ: Filter damage BL: QA Audit Qualifier Codes Data does not meet a particular criteria, but has been determined to be valid 2: Operational deviation SX: Does not meet siting criteria 23

Null data codes, qualifier codes and flags Informational Flags ( I series) Related to external environmental conditions J: construction IT: wildfire Request for Exclusion Flags ( r series) Formal request for data exclusion under the Exceptional Events Rule (EER) rj: high winds rt: wildfire 24

Null data codes, qualifier codes and flags AA BA BD AB AC AF BE AU AW MB AA BM BC AV BD BJ AZ DA AP AQ ST SA MC AM XX DL TS AI AN BH BL BM BN AD AE FI TC BI AH AG CS AR AS BK AX AK ST AT BD BR AB AY AN AJ AO AL BB BF BL XX AW AA SC BA AS BD AX AT DL AB BD AE DL SA BM FI AR AF AJ TC AB AB BA AA DA AY ST CS BH AV BE MC 25

Null data codes, qualifier codes, and flags Code/Flag Recommendations Always code missing data Use descriptive qualifier codes or informational flags Do not use Miscellaneous Void (AM) CONSISTENCY AQS coding should be part of data validation SOP Rationale for data code/flags should be supported by the appropriate DOCUMENTATION Station logbooks QC check & audit documentation Maintenance records Validation records 26

2015 PM 2.5 FRM null data code distribution [CATEGORY NAME]- Multi-Point Calibration [PERCENTAGE] [CATEGORY NAME] - Voided by Operator [PERCENTAGE] [CATEGORY NAME] - Abberant Data [PERCENTAGE] 2015 PM 2.5 (88101) Null Code Data [CATEGORY NAME] - Detection Limit Analysis [PERCENTAGE] [CATEGORY NAME] - Unable to Reach Site [PERCENTAGE] [CATEGORY NAME] - Precision/Zero/Span [PERCENTAGE] [CATEGORY NAME] - Poor QA Results [PERCENTAGE] [CATEGORY NAME] - Machine Malfunction [PERCENTAGE] [CATEGORY NAME] - Site Computer / Data Logger Down [PERCENTAGE] [CATEGORY NAME] - Calibration [PERCENTAGE] [CATEGORY NAME] - Maintenance / Routine Repairs [PERCENTAGE] [CATEGORY NAME] - Miscellaneous Void [PERCENTAGE] 27

AQS Data Coding Exercise DESCRIPTION: Audit team performs a semi-annual flow check on a PM 2.5 FEM BAM1020 POSSIBLE CODE/FLAGS: BC: Multi-Point Calibration AT: Calibration BL: QA Audit BM: Accuracy Check AM: Miscellaneous Void 28

AQS Data Coding Exercise DESCRIPTION: Site technician takes an ozone analyzer off-line and performs a one-point QC check POSSIBLE CODE/FLAGS: BD: Auto Calibration AY: QC Control Points (zero/span) BF: Precision/Zero/Span AC: QC Audit AX: Precision Check 29

AQS Data Coding Exercise DESCRIPTION: During a filter weighing session, the lab technician discovers that there is a fingerprint on the filter. POSSIBLE CODE/FLAGS: AJ: Filter Damage AQ: Collection Error AR: Lab Error BJ: Operator Error FI: Filter Inspection Flag 30

AQS Data Coding Exercise DESCRIPTION: An ozone probe is within 10 m of a tree dripline. POSSIBLE CODE/FLAGS: 3: Field Issue SX: Does Not Meet Siting Criteria QX: Does Not Meet QC Criteria SC: Sampler Contamination AM: Miscellaneous void 31

AQS Data Coding Exercise DESCRIPTION: A storm knocked out the power to the site. POSSIBLE CODE/FLAGS: AL: Voided by Operator BB: Unable to Reach Site AR: Lab Error AF: Scheduled but not Collected AV: Power Failure 32

AQS Data Coding Exercise DESCRIPTION: The data logger failed to upload the data. Upon arrival to the station it was found that the site s computer and data loggers were disconnected. POSSIBLE CODE/FLAGS: BC: Multi-Point Calibration AT: Calibration BK: Site Computer/ data logger down AQ: Collection Error AM: Miscellaneous Void 33

AQS Data Coding Exercise DESCRIPTION: Site operator does not lock the door to the monitoring site and leaves a sandwich on top of an ozone analyzer. A bear enters the site and destroys everything. POSSIBLE CODE/FLAGS: AW: Wildlife Damage AP: Vandalism BJ: Operator Error BK: Site Computer/ Data Logger Down 6: QAPP Issue 34

What s wrong with this AMP 350 Raw Data Report? 35

Top 10 issues with AQS 1. No monitor open/close date 2. Incorrect method codes 3. Incorrect sampling frequency (PM 2.5 /PM 10 ) 4. Incorrect use of null data codes 5. Late or missing data 6. Incorrect parameter code (i.e FEM monitors w/ non-regulatory codes) 7. Missing QA/QC data 8. Other monitor type 9. No designated primary monitor (affects collocation) 10. Outdated QAPPs 36

AQS Updates Support for Discoverer has already been dropped OAQPS is working on a Discoverer replacement Currently working on a PM 10 combined site report Update to allow for batch upload to monitor metadata fields Expansion of seasonal sampling for all pollutants Support for multiple/simultaneous file upload RSS Feed: https://www.epa.gov/feed/37577/rss.xml 37

AQS new user information New User: Register for a User ID and password Fill out and sign AQS User Registration and Security Guidelines forms Mail or FAX both sheets to EPA, NADG (919) 541-7674 or via email to EPACallCenter@epa.gov Once registered, you will be emailed an AQS User ID and password. Use your Java-enabled web browser to go to https://www.epa.gov/aqs 38

ARB Data Quality Reports ARB produces an annual Data Quality Report to assess data quality in relation to measurement quality objectives for each district. See where your district can improve AQS reporting. 39

Resources Region 9: Fletcher Clover 415.972.3991 clover.fletcher@epa.gov EPA Helpdesk 866.411.4372 epacallcenter@epa.gov 40