P2M2HBVL12400xxx USER MANUAL.

Similar documents
Operating instructions Memory plug E /02 11/2011

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

Manual LioN-P - IO-Link Device - I/O Hub

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

G3 Series DeviceNet TM Technical Manual

AXL E IOL AO1 U M12 R

Online data sheet STR1-SAFM03P5 STR1 NON-CONTACT SAFETY SWITCHES

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

1. Installation DEVICENET INTERFACE. Install the DeviceNet Interface using the following procedure:

Compact Multiprotocol I/O Module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

GEMÜ 1235 Electrical position indicator

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Manual Control Unit GFC 32

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

Operating instructions. Switching amplifier DN0210 DN / / 2015

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

Valve island VM10 with PROFINET Interface 8, 10, 12 or 16 stations. Operation & Service Manual

Power Amplifiers for PVH-EDC Pumps

Absolute Encoders Multiturn

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

TECHNICAL PRODUCT DATASHEET

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Copyright: December 2017 Nidec Issue: E

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

ValveExpert Checker. Manual. Version 2.3

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

SK TU4-IOE-M12-C Part Number

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Valve island VS18/VS26 with PROFINET Interface. Operation & Service Manual

SafeC S to MSR127 Conversion

Page 1. Version: V Release date: Copyright / 0x0136 Bytes: / 0x01 0x / 0x00037C Bytes: C / 0x00 0x3 0x7C

Compact Multiprotocol I/O Module for Ethernet 8 IO-Link Master Channels 4 Universal Digital PNP Channels, 2 A, Channel Diagnostics TBEN-L5-8IOL

Solid State Remote Power Controller E /627

Manual Simatek Control Unit GFC 32

Ethernet Spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-L5-EN1

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Model 3750 Multifunction I/O Card

01325T -- Robot Welder

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

System manual AS-i safety monitor AC041S /00 05/2013

Device manual AS-i PowerSwitch ZB0028 ZB0040

SS2200 Remote Controller

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

PAC BI-DP BIM and 8701-CA-BI Carrier

CPU ONE PLC PLC USER S MANUAL

Priva Blue ID Analogue output module with manual override AO2m/AO4m

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

Diagnostics (Logical) Diagnostics (Physical)

IO-Link System Description Technology and Application

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

E1 Plus Electronic Overload Relay

Pluto AS-i. Safety PLC. Approvals: Control of: Features:

EL731 PROFIBUS INTERFACE

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Original operating instructions Safety relay with relay outputs G1501S / / 2016

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

BNI IOL-104-S01-Z012-C02

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

SMARTSCAN INFORMATION

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SK CU4-EIP-C Part number:

Diagnostics (Physical)

Install the DeviceNet Module using the following procedure:

MICRO-SCREEN DIN Controllers with DeviceNet Trip Output

VersaMax IP Input Module

Type code. TBEN-S2-4IOL Ident no Supply. Total current max. 4A per voltage group

AI-917-A0. Analogue Input Module (4x 0-20 ma)

Powered Roller Controller for DeviceNet

Products and solutions for IO-Link

2005/2012 Series Profibus DP Technical Manual

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Ethernet Spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-L5-EN1

QCPort Cover Control Trouble Shooting Guide

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

Manual ICA-16DI-G60A-IO, ICA-10DI6DO-G60A-IO. I/O Hub with IO-Link

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

IO-Link System Description. Technology and Application

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

02/11/2015

Transcription:

Moduflex Modules P2M2HBVL12400xxx USER MANUAL www.comoso.com

Page 2/14

Product General Overview 04 Purpose of the Moduflex IO Link Module 04 Module assembly / disassembly 04 Technical Data 05 IO Link module electrical specifications 05 Auxiliary Power supply determination 05 Page Solenoid Pilots addressing and Process mapping 06 to 07 IO Link Module addressing used with Moduflex Valve System 06 IO Link Module addressing used with H Micro Valve Series 06 IO Link Module addressing used with H ISO Series 15407 2 07 IO Link Module addressing used with H ISO Series 5599 2 07 IO Link module connection 08 IO Link and Auxiliary power connection 08 IO Link module connected to SAFE power for valve control 08 Configuration IODD File 09 Diagnostic 09 Local diagnostic 09 Network diagnostic 09 Aux power management 10 Power supply diagnostic through LED 10 Power supply diagnostic thought IO Link and process mapping 10 Default values 10 Auxiliary power supply range adjustment 10 Switching cycle counter management 11 Over current or over temperature management 11 System Commands 12 Events 12 Page 3/14

Product general overview Purpose of the Moduflex IO Link Module P2M2HBVL12400 The Moduflex IO Link module has been designed to be connected to either an IO Link Master Class A or Class B It can be used with either the Moduflex Valve System, H Micro or H ISO 15407 2 and 5599 2ValvesSeries It can controls up to 24 pilot solenoids valves depending on the valve series it is connected to, as shown on the illustration below: Class A Moduflex Valve Up to 19 pilots H Micro Up to 24 pilots P2M2HBVL12400A13 P2M2HBVL12400A42 P2M2HBVL12400A43 Class B H ISO 15407-2 Sizes 02 & 01 Up to 24 pilots P2M2HBVL12400B25 Module assembly / disassembly H ISO 5599-2 Sizes 1, 2 & 3 Up to 24 pilots 3/5 2 4 1 For details on appropriate valve adaptor to use, please refer to the respective valve series technical catalogue and instruction sheets. To disassembly, follow steps backward Page 4/14

Technical Data IO Link module electrical specifications Description Value IO Link power supply According to IO Link standard Speed communication Com 2 38 kbd Auxiliary power supply 20,4 Vdc to 26,4 Vdc Current limit per channel 150 ma Max. current limit 4 A Polarity inversion protection YES Short circuit protection YES Operating temperature 0 C to +55 C Storage temperature 25 C to +70 C Shock According to IEC 60068 2 27:2008 Vibration According to IEC 60068 2 6:2007 EMC According to EN 55011 & EN 61000 4 2 up to 4 6 Auxiliary power consumption calculation Depending on the valve range the module is connected to, pilot solenoids have not the same power consumption. In order to determine the minimum required power to supply, you can use the table below: Valve Range Number of Pilots simultaneously powered Power Total Moduflex Valve System x 40 ma ma H Micro x 40 ma ma H ISO 15407 2 Sizes 02 & 01 x 40 ma ma H ISO 5599 2 Sizes 1, 2 & 3 x 133 ma ma Total : ma Page 5/14

Solenoid Pilots addressing and Process mapping IO Link Module addressing used with Moduflex Valve System The Moduflex IO Link module used with Moduflex Valve System can handle up to 19 pilot solenoid valves. ing will be done as shown below: EV01 EV02 EV03 EV04 EV05 EV06 EV07 EV08 EV09 EV10 EV11 EV12 EV13 EV14 EV15 EV16 EV17 EV18 EV19 PLC Process outputs data mapping 7...... 3 2...... 0 Byte 0 EV08.............. EV01 Byte 1 EV16.............. EV09 Byte 2* EV24..... EV20 EV19... EV17 * Byte 2 / Bits 3 to 7 are not connected to valves with Moduflex Valve Range IO Link Module addressing used with H Micro Valve Series The Moduflex IO LinkmoduleusedwithHMicroValveSeriescanhandleupto24pilotsolenoidvalves. ing will be done as shown below: Single Single EV01 EV02 EV05 EV06 EV09 EV11 EV13 EV15 EV17 EV18 EV21 EV22 EV04 EV03 EV08 EV07 EV10 EV12 EV14 EV16 EV20 EV19 EV24 EV23 PLC Process outputs data mapping Byte 0 Byte 1 Byte 2 7..................... 0 EV08.............. EV01 EV16.............. EV09 EV24.............. EV17 Page 6/14

IO Link Module addressing used with H ISO Series 15407 2 The Moduflex IO Link module used with H ISO Series 15407 2 sizes 02 & 01 can handle up to 24 pilot solenoid valves. ing will be done as shown below: Single Single EV01 EV03 EV05 EV07 EV09 EV10 EV15 EV16 EV11 EV13 EV17 EV19 EV21 EV23 EV02 EV04 EV06 EV08 EV12 EV14 EV18 EV20 EV22 EV24 PLC Process outputs data mapping Byte 0 Byte 1 Byte 2 7..................... 0 EV08.............. EV01 EV16.............. EV09 EV24.............. EV17 IO Link Module addressing used with H ISO Series 5599 2 The Moduflex IO Link module used with H ISO Series 5599 2 sizes 1, 2 & 3 can handle up to 24 pilot solenoid valves. ing will be done as shown below: Single Single Single EV01 EV03 EV05 EV06 EV08 EV09 EV11 EV22 EV23 EV02 EV04 EV07 EV10 EV12 EV24 PLC Process outputs data mapping Byte 0 Byte 1 Byte 2 7..................... 0 EV08.............. EV01 EV16.............. EV09 EV24.............. EV17 Page 7/14

IO-Link module connection P2M2HBVL12400 IO-Link and Auxiliary power connection Standard male M12 type A Use of standard manufactured cables available from usual electrical supplier is recommended. Notes: Auxiliary power for solenoids can be wired allowing to turn outputs OFF while communications remaining active. 3 Class A variants ( A13, A42 & A43) are available to follow different M12 supplier connections using standard cable. Class B Class A Legend Symbol Description L+ IO Link Power Supply "+" L IO Link Power Supply " " C/Q IO Link communication Aux + Auxiliary Power Supply 24 Vdc Aux Auxiliary Power Supply Class B Class A Class A M12 5 Pin s 3 Pin s 3 Pin s 5 Pin s Pin s P2M B.. P2M A.. P2M A13 P2M A43 P2M A42 L+ L+ 1 Aux + not used not used Aux + 2 Aux L L 3 Aux Aux not used C/Q C/Q 4 not used Aux + Aux + Aux 5 not used IO-Link module connected to SAFE power for valve control The Moduflex IO Link Module can be powered from a SAFE 24Vdc auxiliary source in PP or PM mode as grounds are isolated. Aux Power PP Cabling Class A P2M2HBVL12400A13 Aux Power PM Cabling L+ C/Q L Aux Power PP Cabling Class B P2M2HBVL12400B25 L+ C/Q L Aux Power PM Cabling Aux Power PP Cabling Class A P2M2HBVL12400A43 Aux Power PM Cabling Aux Power PP Cabling Class A P2M2HBVL12400A42 Aux Power PM Cabling Note: Usage of this module with OSSD test pulsed as power source could not be possible unless the pulse can be adjusted to longer than 8ms. For additional guidance for this case of use, please contact your PARKER customer service. Note : Please check max. power available from the source. Refer to the Auxiliary power consumption calculation section Page 8/14

Configuration IODD File IODD file can be downloaded from IODD Finder or the Moduflex IO Link web site: https://ioddfinder.io link.com www.parker.com/pde/io link Diagnostic Local diagnostic through LED: The Moduflex IO Link module offers a local diagnostic through 4 LED s status with interpretation described in the table below: Green LED Red LED Red LED Green LED LED Status OFF Description IO Link L+ / L line not powered Solving Check IO Link power supply from IO Link Master (pin's 1 & 3) LED Status OFF Description Standard mode (No error active) Solving LED Status Description N/A OFF Standard mode (No error active) Solving LED Status Description N/A OFF Auxiliary power failure < 18V or > 28,5V Solving Check Auxiliary Power Supply ON IO Link L+ / L line powered IO Link master port set as SIO mode Blinking IO Link communication active 90% Set IO Link master channel in IO Link mode N/A ON 24 Vdc Auxiliary Check Auxiliary power missing or any power supply. active malfunction If auxiliary power supply OK, module must be replaced Module Diagnostic ON Any outputs driver error (Auxiliary power error, overload, short circuit, over temperature, ) If auxiliary power OK (see Power LED status), check error messages and related troubleshooting Outputs (valves) Diagnostic ON Standard mode (Auxiliary power within normal range 20,4V* to 26.4V*) Blinking Auxiliary Power out of range (Warning level*) 50% 50% N/A Check Auxiliary Power Supply Check/reset adjusted values 1s IO Link Communication 1s *): Warning level values could have been modified by the user! Default values can be restored at any time (please refer to "Aux power management" section) Auxiliary Power Supply Diagnostic through network via process inputs data: The Moduflex IO Link module offers diagnostic data transmitted to the PLC as inputs process data through the IO Link master: Diag bit Error message Detail Diag 0 Fail Safe Status Acknowledgment Required Diag 1 Auxiliary Voltage Warning Auxiliary Voltage Out of range. Check Auxiliary Power line Diag 2 Auxiliary Voltage failure Auxiliary Voltage Out of order. Check Auxiliary Power source Diag 3 Module Failure Switch OFF / ON auxiliary power. If error message persists, replace the module Diag 4 Module Over Temperature Switch OFF / ON auxiliary power. If error message persists, replace the module Diag 5 Module Over Load Check overall Pilot Solenoid valves. If error message persists, replace the module Diag 6 Pilot Solenoid(s) Short Circuit Check faulty pilot solenoid valve(s), replace if necessary Diag 7 Outputs Stage Failure Switch OFF / ON auxiliary power. If error message persists, replace the module Errors caused by solenoid(s) must be fixed first and then the error must be acknowledged: by switching OFF/ON Auxiliary power supply (once error is fixed) by sending the Acknowledge command: Command Name Description 0xA0 Acknowledge PLC Process input data mapping 7...................... 0 Byte 0 Diag 7............. Diag 0 If no error is pending, the failsafe state on the device is left and the outputs are switched according to process data Page 9/14

Aux power management P2M2HBVL12400 Power supply diagnostic through LED The Moduflex IO Link module monitors the auxiliary power supply voltage and manages two levels of diagnostic; failure or out of normal range. The normal range can be modified through parameter data. Auxiliary Power Supply Green LED LED Status OFF Description Auxiliary power failure < 18V or > 28,5V Solving Check Auxiliary Power Supply ON Standard mode (Auxiliary power within normal range 20,4V* to 26.4V*) N/A To restore default value (factory setting), please refer to System Commands section LED function details: Auxiliary power error is active from 0 to 18 Vdc or > 28,5 Vdc When Auxiliary power error is active, LED is solid red Power supply diagnostic thought IO Link and process data mapping PLC mapping Process input 7 6 5 4 3 2 1 0 Byte 0 Diag 7... Diag 0 Blinking Auxiliary Power out of range (Warning level*) 50% 50% Check Auxiliary Power Supply Check/reset adjusted values 1s *): Warning level values could have been modified by the user! Default values can be restored at any time (please refer to "Aux power management" section) Diag 1 : Auxiliary Voltage out of range, Alarm. Range can be set via parameter data Diag 2 : Auxiliary Voltage failure. < 18 V or > 28,5 V. Acknowledge is required (Diag 0) Default values Normal auxiliary power supply range is set as 20,4V < Aux power supply < 26,4V Auxiliary power supply range adjustment Aux power supply range is adjustable using output parameters and value is available as parameter input. Index Sub index Data Type Bit length Access Name Description 67 0 Uint16 16 Read Current Aux. voltage value Aux voltage, unit is mv 70 0 Record 32 Read / Write Aux. voltage warning levels Levels for AUX voltage warning Unit is mv First 16 bits: Low level value (default 20400) Second 16 bits: High level value (default 26400) Restore default values Default values can be sestored by using the system command below: Commande Nom Description 0x82 Restore factory setting Reset parameters to default values Page 10 /14

Switching cycle counters management The Moduflex IO Link module manages 24 counters, one for each output, to provide solenoid s switching cycle. Those counters are automatically stored onto an EEPROM every 30 minutes. In case of IO Link power supply turned to OFF, the current counters value will be lost and the latest stored values onto the EEPROM will be restored as current values at next start up. To prevent this, before an IO Link power off between two automatic savings, the command below allows to force the storage of the current counters value Command Name Description 0xA1 Store switching cycles Counters values are available through input parameters When this command is executed, the current values of the 24 switching cycle counters are stored into EEPROM. Index Sub index Data Type Bit length Access Name Description 64 1 to 24 Array of Uint32 24 x 32 = 768 Read Counters values can be individually reset to 0 Switching Cycles Switching cycle counter: Sub index 1 refers to cycle counter of the first output Sub index 24 refers to the cycle counter of the 24th output Index Sub index Data Type Bit length Access Name Description 65 0 Uint24 24 Write Clear Switching Cycles Over current or over temperature management Clear the switching cycle counters. For every bits set in this parameter, the according counters are set to zero. The least significant bit refers to the first output (EV01) Values stored onto the EEPROM are automatically reset too The Moduflex IO Link module monitors the current & temperature values of the 24 outputs. As soon as a short circuit or over temperature is detected, the module switches to failsafe mode and all outputs are switched off. Channel(s) responsible for this output error can be read in the input parameter. Index Sub index Data Type Bit length Access Name Description 66 0 Uint32 32 Read Channel Error If an error occurred, this parameter shows which channel(s) caused the error. The least significant bit refers to the first output (EV01) Errors caused by solenoid(s) must be fixed first and then the error must be acknowledged: by switching OFF/ON Auxiliary power supply (once error is fixed) by sending the Acknowledge command: Command Name Description 0xA0 Acknowledge If no error is pending, the failsafe state on the device is left and the outputs are switched according to process data Page 11 /14

System Commands P2M2HBVL12400 Command Name Description 0xA0 Acknowledge If no error is pending, the failsafe state on the device is left and the outputs are switched according to process data 0xA1 Store switching cycles When this command is executed, the current values of the switching cycle counters are stored into EEPROM. 0x82 Restore factory setting Reset parameters to default values. Cycles counters are not reset. Events Event Code Name Type Description Required user/plc inter action 0x4000 Temperature fault Error Outputs were switched off due to over temperature warning. Check the parameter Channel Error to see which output driver triggered this error. Check load. Acknowledge required 0x5000 Output error Error This event occurs when controlling the outputs is not possible. Switch OFF / ON auxiliary power. If event persists, replace the module 0x8CA0 Output driver channel Error Error Output drivers are switched off due to over current or over temperature of at least one channel. All outputs are switched off.. Check parameter to see which channel triggered this error. Fix solenoid issue. Acknowledge required 0x8CA1 Current overload Error Polyfuse of at least one out put driver tripped. Check parameter to see which channel triggered this error. Fix solenoid issue. Acknowledge required 0x8CA3 Module error Error Internal communication failed Switch OFF / ON auxiliary power. If event persists, replace the module 0x8CA4 Aux power supply voltage warning Warning AUX voltage is out of range Check power supply. 0x8CA5 Aux power supply voltage error Error AUX voltage failed Check power supply. Acknowledge required Page 12 /14

Notes:........................................................ Page 13 /14

PARKER Hannifin Manufacturing France SAS Europe Parc d'activités de la Forêt BP 3124 534, rue Henri Becquerel 27031 EVREUX CEDEX FRANCE www.comoso.com Moduflex Modules UK Release May 2017