Fisher i2p-100 Electro-Pneumatic Transducer

Similar documents
Type i2p-100 Electro-Pneumatic Transducer

Fisher i2p-100 Electro-Pneumatic Transducer

Fisher i2p-100 Electro-Pneumatic Transducer

DVC2000 Series FIELDVUE Digital Valve Controllers

Fisher FIELDVUE DVC2000 Digital Valve

Fisher FIELDVUE DVC2000 Digital Valve

Fisher FIELDVUE DVC6200 HW2 Management of Change Guide

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

Series 3730 Type Electropneumatic Positioner

General Specifications

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

General Specifications

Baumann Little Scotty Bronze Control Valve

Explosion Proof I/P Transducer

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

TopWorx 4310 Wireless Position Monitor

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

M5100 Heavy Industrial Pressure Transducer

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide

Series 3730 Electropneumatic Positioner Type

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Series 3730 Type Electropneumatic Positioner

Miniature I/P, E/P Transducer

PROFIBUS-PA Positioner Type 3785

NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Supplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual

Digital Positioner 8049

VALVE ACCESSORIES & CONTROLS V100 POSITIONER VAC V100 SERIES POSITIONER SIMPLE DURABLE RELIABLE

SIY. Features. PC-Programmable Signal Isolator/Converter

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

CHRONOS IDP INTEllIGENT DIGITAl POSITIONER FOR CONTROl VAlVES

General Specifications

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

DeltaV Bulk Power Supplies

Type 330SA High-Performance Electric Actuator

Smart Wireless THUM Adapter

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Rosemount 248 Wireless Temperature Transmitter

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

BA414DF Fieldbus indicator Single variable

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

DeltaV Bulk Power Supplies

M7100 Pressure Transducer

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

U7100 Pressure Transducer

Series Panel Mounted Control Devices

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

T EN TROVIS Electropneumatic Positioner

NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

Fisher FIELDVUE DVC6200p Digital Valve

Material pressure (bar) (Cv (US) kv x 1,2 Seat

General Specifications

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Lead Wire Type, 1/2-20

FloBoss 107 IEC Interface

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

AS-interface Network Card

FLEX Ex Spring Clamp Terminal Base

JT400 Multivariable Transmitter

NELES ND7000 DIGITAL VALVE CONTROLLER

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Installing ValveLink DTM Software

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Electropneumatic Positioner Type and Type with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Technical Information Promonitor NRF560

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm)

Series 3730 Electropneumatic Positioner Type and Type with HART communication

1756 ControlLogix Chassis Specifications

SCADAPack Modbus multivariable transmitter

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

General Specifications

SIY. New. Features! Features. PC-Programmable Signal Isolator/Converter

FICHA TÉCNICA DE PRODUTO

SFY Functional Safety Frequency-to-DC Transmitter with Display

TPE 1464 Series Pressure Transducer

SCADAPack Modbus multivariable transmitter

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

Supplementary Components WirelessHART products

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

TopWorx 4310 Wireless Position Monitor with On/Off Control Option

3420 Fieldbus Interface Module (FIM) Contents

SideControl Positioner

3200IQ Digital Positioner

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

CompactBlock Guard I/O EtherNet/IP Safety Modules

Transcription:

i2p-100 Transducer Product Bulletin Fisher i2p-100 Electro-Pneumatic Transducer The Fisher i2p-100 electro-pneumatic transducer, uses a converter module that converts a milliampere input to a proportional pressure output. Both the current input and pressure output range are user-configurable in the field. The converter module uses small parts of minimum mass, which are balanced symmetrically around a pivot point at the center of the mass. This balanced arrangement results in a high performance instrument that reduces sensitivity to vibration. An integral pneumatic relay provides the high capacity necessary to drive pneumatic control valve/actuator assemblies without additional boosters or positioners. The transducer also provides stable, accurate operation when its output is transmitted to small volume chambers, such as a pneumatic positioner or other pneumatic instrument. Reduced sensitivity to vibration, combined with high capacity and first order lag characteristics, make the i2p-100 transducer suitable for direct mounting on control valve/actuator combinations. INTEGRAL PNEUMATIC RELAY W8710 REPLACEABLE FILTER WITH REMOVABLE ORIFICE VENT High Output Capability and Rangeability The integral output relay volume of the transducer is adequate to drive valve/actuator combinations without requiring a positioner or volume booster. Selectable user field-configurable dip switch setting for output range of 0.14 to 2.3 bar (2 to 33 psi). Split Range Selectable user field-configurable two-way split range, using either half of the standard input signal. Features Low Pneumatic Supply Consumption The transducer has low pneumatic supply consumption which lowers operating costs. Approved for use with Natural The i2p-100 is approved for use with natural gas as the pneumatic supply. Single Sealed Device The i2p-100 has been tested in accordance with ANSI/ISA Standard 12.27.01 (Requirements for Process Sealing Between Electrical Systems and Flammable or Combustible Process Fluids) as a single sealed device. Corrosion Resistant Separate housing compartments isolate the electronics from the pneumatic process. The electronics module is encased in a rugged plastic shell which helps to prevent damage to the electronics. The printed wiring board and dip switches are conformal coated to help prevent corrosion. Converter module coils have corrosion resistant coating and all flexures are gold plated to provide protection from hostile environments. Tolerant of Dirty Supply Medium Free-flow pilot stage design and large internal air passages provide excellent tolerance to dirty pneumatic supply, by reducing the effects of contaminant buildup and erosion. The removable primary orifice and replaceable 5 micron filter are easy to remove for service and maintenance. www.fisher.com

Product Bulletin i2p-100 Transducer Figure 1. Fisher i2p-100 Electro-Pneumatic Transducer Mounted on a Rotary Actuator Figure 3. Fisher i2p-100 Electro-Pneumatic Transducer Mounted on a Sliding-Stem Actuator W8693-1 W8723-1 Figure 2. Output-Time Relationships OUTPUT (% OF i2p-100 OUTPUT SPAN) A6815 100 90 80 70 60 50 40 30 20 10 LOADING EXHAUSTING 0 0 10 20 30 40 50 60 70 80 90 100 TIME (%) Easy Maintenance Modular electronics and converter modules contained in separate housing compartments, isolating the electronics from the process, allow for easy replacement in the field for reduced maintenance time and costs. Vibration Resistance The transducer, used in a standard valve/actuator mounted application, exhibits an output shift of less than 1 percent of span when tested to ISA S75.13. Valve Stroking Time Figure 2 shows relative times for loading and exhausting an actuator. Stroking time depends upon the size of the actuator, travel, relay characteristics and the magnitude and rate of change of the input signal. If stroking time is critical, contact your Emerson Process Management sales office. Installation Refer to figure 5 for location of standard mounting holes in the housing. See figures 1 and 3 for typical mounting configurations. Standard mounting hardware is provided for mounting on the actuator, a pipestand, or surface mount. Field wiring connections are made to the terminal block accessible under the housing cap, via the 1/2 NPT conduit connection. Dimensions are shown in figures 5, 6, 7, and 8. Ordering Information To determine what ordering information is required, refer to the Specifications table. Carefully review the description of each specification. Specify the desired choice whenever there is a selection available. Also, specify options that are applicable to the application. 2

i2p-100 Transducer Product Bulletin Specifications Input Signal Available as standard with 4-20 ma. User configurable by dip switch for split ranging, see table below. Output Signal Available as standard 0.2 to 1.0 bar (3 to 15 psig), 0.4 to 2.0 bar (6 to 30 psig), or 0.14 to 2.3 bar (2 to 33 psig). User configurable by dip switch selection and zero and span potentiometer adjustment, see table below. OUTPUT PRESSURE INPUT SIGNAL Bar Psig 0.2 to 1.0 3 to 15 4 to 20 ma DC 0.4 to 2.0 6 to 30 0.14 to 2.3 2 to 33 4 to 12 ma DC 0.2 to 1.0 3 to 15 12 to 20 ma DC 0.2 to 1.0 3 to 15 Equivalent Circuit The i2p-100 equivalent circuit is a series circuit consisting of a constant voltage drop (battery) of approximately 4 VDC and a total resistance of 40 ohms. Input is shunted by two 6.8 V zener diodes (see figure 4). Supply Pressure (1) Recommended: 0.34 bar (5 psi) higher than upper range limit of output signal Maximum: 3.4 bar (50 psig) Medium: Air or Natural (2) Average Steady-State Air Consumption (3)(4) 0.12 m 3 /hr (4.22 scfh) at 1.4 bar (20 psig) supply pressure Maximum Output Air Capacity (4) 8.04 m 3 /hr (300 scfh) at 1.4 bar (20 psig) supply pressure Independent Linearity: ±0.75% of full scale output span Hysteresis: 0.4% of full scale output span Frequency Response: Gain is attenuated 3 db at 6 Hz with transducer output signal piped to a typical instrument input Temperature Effect: 0.14% per degrees Celsius ( 0.075 per degrees Fahrenheit) of span Supply Pressure Effect: 0.2% of full scale output span per psi supply pressure change) Vibration Effect: Less than 1% of full scale output span when tested to ISA S75.13 Electromagnetic Compatibility Meets EN 61326-1 (First Edition) Immunity Industrial locations per Table 2 of EN 61326-1 Standard. Performance is shown in table 1 below. Emissions Class A ISM equipment rating: Group 1, Class A Operating Ambient Temperature Limits (1) -40 to 85 C (-40 to +185 F) Electrical Seal Single sealed device per ANSI/ISA 12.27.01 Electrical Classification Hazardous Area: CSA Intrinsically Safe, Explosion proof, Type n, Dust Ignition proof FM Intrinsically Safe, Explosion proof, Type n, Non incendive, Dust Ignition proof ATEX Intrinsically Safe & Dust, Flameproof & Dust, Type n & Dust IECEx Intrinsically Safe, Flameproof, Type n Refer to tables 2, 3, 4, and 5 for specific approval information. Approved for use with natural gas (2). Electrical Housing: Performance (5) Reference Accuracy: ±1.0% of full scale output span; includes combined effects of hysteresis, linearity, and deadband When Remotely Vented CSA Type 4X Encl. FM NEMA 4X ATEX IP66 IECEx IP66 No Remote Venting CSA Type 3 Encl. FM NEMA 3 ATEX IP64 IECEx IP64 -continued- 3

Product Bulletin i2p-100 Transducer Specifications (continued) Other Classifications/Certifications INMETRO Brazil Contact your Emerson Process Management sales office for classification/certification specific information Construction Materials Housing: Low-Copper aluminum with polyurethane paint O-rings: Nitrile Diaphragms: Nitrile Adjustments (6) Zero and Span: Trim potentiometers (20 turn) for zero and span adjustments are located under the housing cap. Switch: Allows input signal split range and user-configurable 0.14 to 2.3 bar (2 to 33 psig) output. Connections Supply and Output Pressure: 1/4 NPT internal connection Vent: 1/4 NPT internal Electrical: Standard 1/2 NPT Wire Size: 18 to 22 AWG Mounting Position Actuator pipestand or surface Approximate Weight 2.5 kg (5.5 lbs) Options Output pressure gauge M20 or PG13 conduit adapter NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology 1. The pressure and temperature limits in this document and any applicable standard or code limitation should not be exceeded. 2. This product is approved for use with natural gas. 3. Average flow rate determined at 12 ma and 0.6 bar (9 psig) output. 4. Normal m 3 /hour--normal cubic meters per hour (0 C and 1.01325 bar, absolute). Scfh--Standard cubic feet per hour (60 F and 14.7 psig). 5. Performance values are obtained using a transducer with a 4 to 20 ma DC input signal and a 0.2 to 1.0 bar (3 to 15 psig) output signal at an ambient temperature of 24 C (75 F). 6. For other ranges, zero and span adjustments needed. Table 1. EMC Summary Results Immunity Port Phenomenon Basic Standard Test Level Performance Criteria (1) Electrostatic discharge (ESD) IEC 61000-4-2 4kV Contact 8kV Air A Enclosure 80 to 1000 MHz @ 10V/m with 1 khz AM at 80% Radiated EM field IEC 61000-4-3 1400 to 2000 MHz @ 3V/m with 1 khz AM at 80% A 2000 to 2700 MHz @ 1V/m with 1 khz AM at 80% Burst (fast transients) IEC 61000-4-4 1 kv A I/O signal/control Surge IEC 61000-4-5 1 kv (line to ground only, each) A Conducted RF IEC 61000-4-6 150 khz to 80 MHz at 3 Vrms A Specification limit = ±1% of span 1. A=No degradation during testing. B = Temporary degradation during testing, but is self-recovering. Figure 4. Equivalent Circuit 4-20 ma 6.8V 6.8V 4V 40 Ohm 4

i2p-100 Transducer Product Bulletin Figure 5. Dimensions 58.7 (2.31) 1/2 14 NPT CONDUIT CONNECTION 22.3 (0.88) 74.2 (2.92) 36.3 (1.43) 34.7 (1.37) 103.9 (4.09) 103.9 (4.09) 81.6 (3.21) GE06439 (sheet 1 of 4) 67.8 (2.67) 33.3 (1.31) 55.7 (2.19) 98.7 (3.89) 1/4 18 NPT SUPPLY CONNECTION 1/4 18 NPT VENT OR PIPE-A-WAY CONNECTION 1/4 18 NPT OUTPUT CONNECTION 67 (2.62) CAP REMOVAL 22.9 (0.90) 33.3 (1.31) 75.2 (2.96) 33.3 (1.31) 75.7 (2.98) 1/4 18 NPT OUTPUT CONNECTION 67 (2.62) CAP REMOVAL mm (INCH) Figure 6. Dimensions with Optional Fisher 67 Filter-Regulator (Yoke/Bracket Mounted) 67 (2.62) COVER REMOVAL (BOTH COVERS) 238.1 (9.37) 69.9 (2.75) 8.6 (0.34) 74.2 (2.92) 6.4 (0.2 5) 126.3 (4.97) 57.2 (2.25) 50.8 (2.00) 170.8 (6.72) 101.1 (3.98) GE06439 (sheet 2 of 4) 240 (9.45) 204.8 (8.06) mm (INCH) 5

Product Bulletin i2p-100 Transducer Figure 7. Dimensions with Optional Fisher 67 Filter-Regulator (Surface/Wall Mounted) 146.1 (5.75) 67 (2.62) COVER REMOVAL (BOTH COVERS) 146.1 (5.75) 91.1 (3.59) GE06439 (sheet 3 of 4) 209.6 (8.25) mm (INCH) Figure 8. Dimensions with Optional Fisher 67 Filter-Regulator (Pipestand Mounted) 67 (2.62) COVER REMOVAL (BOTH COVERS) 238.1 (9.37) 60.5 (2.38) 50.8 (2.00) 74.2 (2.92) 170.8 (6.72) GE06439 (sheet 4 of 4) 240 (9.55) 243.2 (9.58) mm (INCH) 6

i2p-100 Transducer Product Bulletin Table 2. Hazardous Area Classifications CSA (Canada) Certification Body Certification Obtained Entity Rating Temperature Code Enclosure Rating CSA *When remotely vented. Intrinsically Safe Ex ia IIC T3/T4/T5 per drawing GE07471 Ex ia Intrinsically Safe Class I, II, III Division 1 GP A,B,C,D,E,F,G per drawing GE07471 Explosion Proof Ex d IIC T5/T6 Class I, Division 1 GP, A,B,C,D T5 Type n Ex nc IIC T5/T6 Class I, Division 2, GP A,B,C,D T5 Class II, Division 1 GP E,F,G T5 Class II, Division 2, GP F,G T5 Class III Table 3. Hazardous Area Classifications FM (United States) Vmax = 30 VDC Imax = 150 ma Pi = 1.0 W Ci = 0 uf Li = 0 uh T3 (Tamb 85 C) T4 (Tamb 81 C) T5 (Tamb 46 C) CSA Type 4X Encl.* CSA Type 4X Encl.* CSA Type 4X Encl.* CSA Type 4X Encl.* Certification Body Certification Obtained Entity Rating Temperature Code Enclosure Rating FM *When remotely vented. Intrinsically Safe Class I Zone 0 AEx ia IIC T3/T4/T5 per drawing GE07470 Class I, II, III Division 1 GP A,B,C,D,E,F,G per drawing GE07470 Explosion Proof Class I Zone 1 AEx d IIC T5/T6 Class I, Division 1, GP A,B,C,D T5/T6 Type n Class I Zone 2 AEx nc IIC T5/T6 Class I, Division 2, GP A,B,C,D T5/T6 Class II, Division 1 GP E,F,G T5/T6 Class II, Division 2, GP F,G T5/T6 Class III Table 4. Hazardous Area Classifications ATEX Vmax = 30 VDC Imax = 150 ma Pi = 1.0 W Ci = 0 uf Li = 0 uh T3 (Tamb 85 C) T4 (Tamb 81 C) T5 (Tamb 46 C) NEMA 4X* NEMA 4X* NEMA 4X* NEMA 4X* Certificate Certification Obtained Entity Rating Temperature Code Enclosure Rating ATEX *When remotely vented. Intrinsically Safe II 1 GD Ex ia IIC T3/T4/T5 Dust T95 C (Tamb 85 C) Flameproof II 2 G D Ex d IIC T5/T6 Dust T95 C (Tamb 85 C) Type n II 3 G D Ex nc II T5/T6 Dust T95 C (Tamb 85 C) Ui = 30 VDC Ii = 150 ma Pi = 1.0 W Ci = 0 nf Li = 0 mh T3 (Tamb 85 C) T4 (Tamb 81 C) T5 (Tamb 46 C) 7

Product Bulletin i2p-100 Transducer Table 5. Hazardous Area Classifications IECEx Certificate Certification Obtained Entity Rating Temperature Code Enclosure Rating IECEx *When remotely vented. Intrinsically Safe Ex ia IIC T3/T4/T5 Flameproof Ex d IIC T5/T6 Type n Ex nc IIC T5/T6 Ui = 30 VDC Ii = 150 ma Pi = 1.0 W Ci = 0 uf Li = 0 uh T3 (Tamb 85 C) T4 (Tamb 81 C) T5 (Tamb 46 C) Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 8 2004, 2012 Fisher Controls International LLC. All rights reserved.