DVC-8 Vibration Controller

Similar documents
DVC-4 Vibration Controller

SRA V1.0 SHOCK INSTRUMENT

Brüel & Kjær Sound & Vibration Measurement A/S. Copyright All Rights Reserved. LASER USB Vibration Control System

VR9500. Advantages Ease of Use. Features

VIBbox 64-Channel Sound & Vibration Solution

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

Vibration Transducer Calibration System

m+p VibControl Random Vibration Control

MB Millenium Single- and Multi-Axis Vibration and Motion Control System

The Fourth Generation Vibration Control System

Portable vibration calibrator Model 28959G

Take. Control....with the industry s best controller.

SYSTEM DATA. VC-LAN Vibration Controller Types 7541 and Uses and Features

Portable and Online Condition Monitoring System

Advanced Test Equipment Rentals ATEC (2832)

VIBRATION CONTROL SYSTEM

SYSTEM DATA. VC-LAN Vibration Controller Types 7541 and Uses and Features

Compact 8 in 1 Multi-Instruments SF Series

DT Channel Analog Input USB DAQ Module. Key Features:

Engineering Data Management (EDM) Software

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

Vibration Analyzer, Data Collector & Dynamic Balancer

DT9837. High Performance USB Module for Sound & Vibration Analysis. DT9837 Features

Chapter 1 - Introduction

Features Summary. Input Ranges

Design Concepts For A 588 Channel Data Acquisition & Control System

VIBRATION TESTING Photo courtesy of Laser Zentrum Hannover e.v., Germany

CoCo-80X DYNAMIC SIGNAL ANALYZER

Damage Boundary Software

SPIDER-80X SCALABLE DYNAMIC MEASUREMENT SYSTEM

Analog Input Sample Rate

16-Bit A/D Converter (ENOB=14.1) 16-bit D/A. 16-bit D/A. Digital I/O (8/8) Counter/Timer (2)

SPIDER-81 HARDWARE SPECIFICATIONS (v6.0)

Advanced Test Equipment Rentals ATEC (2832)

CHAPTER 5 RANDOM VIBRATION TESTS ON DIP-PCB ASSEMBLY

m+p SO Analyzer Dynamic Signal Acquisition and Analysis

Real-time Vibration Analyzer Software

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

REVOLUTIONIZING Rotating Machinery Data Acquisition and Analysis...

ME scope Application Note 42 Multi-Input Multi-Output (MIMO) FRFs

VIBXPERT Two-Channel FFT Data Collector and Vibration Analyzer

107VF Vibration Analyzer User s Manual

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Agilent U8903A Audio Analyzer

A Walk Through the MSA Software Spectrum Analyzer Mode 12/12/09

Vibration Control System

Practical and Compact!

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

Shaker Control System Featuring USB 2.0 Connectivity

LMS Test.Lab Environmental

CMX18 FEATURES A 18-SLOT 3U PXI EXPRESS CHASSIS

Grayhill, Inc. La Grange, IL

CF-4210Z/4220Z. Personal FFT Analyzers

StrainSmart Data Acquisition System

high performance signal conditioner cards

Advanced Design System 1.5. Data Display

M7100 Pressure Transducer

RT4F-110V/25A RECTIFIER

U7100 Pressure Transducer

PXDAC4800. Product Information Sheet. 1.2 GSPS 4-Channel Arbitrary Waveform Generator FEATURES APPLICATIONS OVERVIEW

PQ ANALYZER PROCUREMENT SAMPLE SPECIFICATION

MULTIPLE SHAKER CONTROL IN EDM SOFTWARE

Solid State Battery Fuel Gauge

EDM 7.1 Engineering Data Management Software Release Notes

ReferenceMate portable reference source REF2500 operation manual

AGATE TECHNOLOGY AT-2040

power quality Models 8230 & 8220

Defining the Global Error of a Multi-Axis Vibration Test: An Application of MIL-STD-810G Method 527 Annex C

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels

DT3016. High-Speed, Multifunction PCI Data Acquisition Board. Overview. Key Features. Supported Operating Systems

6220 Ethernet-Based Voltage Measurement Module

M5100 Heavy Industrial Pressure Transducer

VIBRATION METERS VX-54WH. Hand-Arm Vibration VX-54WB. Whole-Body Vibration VX-54WS. Habitability on Ships. 3-Axis Vibration Meter VM-54

Data Sheet Version 1.0

VM2800 & VM3800 VIBRACHECK METERS Installation Manual

More Precision. optoncdt // Laser displacement sensors (triangulation)

Ultra-Accurate Measurement for Temperature and Voltage

More Precision. optoncdt // Laser displacement sensors (triangulation)

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

Vibration Analyzer Version 1.0.2

Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System

Introduction. Chapter 2

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

ST400C-NT USER S GUIDE. Table of Contents

DS-3000 Series Data Station Operation manual for Vibration Analysis

1 Technical Specification IM1-P

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Peak/Valley Hold Unit (PVHU) User Manual V3.00

4700 Series RAID-Enabled Industrial PCs DS _RAID(C)

Experiment 3. Getting Start with Simulink

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

GE Measurement & Control. from Bently Nevada * Asset Condition Monitoring

PRODUCT PROFILE. WINCAT SERIES 100, 150, and 200 SYSTEMS Including CAT, MiniCAT, LapCAT, and Upgrades.

Features. RoHS COMPLIANT 2002/95/EC

Morset Sound Development. User s Guide

Product Information Sheet PDA14 2 Channel, 14-Bit Waveform Digitizer APPLICATIONS FEATURES OVERVIEW

Digital Signal Conditioning and Control Unit

m+p VibControl Revision 2.14

Transcription:

DVC-8 Vibration Controller Swept Sine Random Classical Shock DVC-8 Features: Sine, Random, and/or Shock models. Established Reliability With 3-Year Warranty. Lifetime Free Software Upgrades and Demo Software. Use With Any Windows PC- Single PCI Slot Required. Easy to Install and Use- Ideal for Production Test and Small Systems. 8 Input Channels with Current Sources standard. Virtual Instrument Screen with Familiar Windows Functions. Remote Control via Hardware or Software. Software Calibration- no Trimpots; Calibration Procedure in Help File.

DVC-8 Vibration Control System For Sine, Random and Classical Shock testing The DVC-8 Vibration Control System was one of the first controllers to take advantage of the Windows Operating System, combining DSP hardware with the Windows interface. This has resulted in a vibration controller with unparalleled economics and easeof-use. The DVC-8 is fully compatible with Windows Xp/Vista, and is available with any or all of the above control modes enabled. Established Reliability As the logical successor to the DVC-4 and ISA slot DSC/DRC controllers, the DVC-8 has a 17- year history with Windows and DOS software and five with Windows; over 1000 systems are in the field, and it is backed with a 3-year warranty. Built-In Accelerometer Current Sources Simply connect the inputs to integrated accelerometers, turn on the current sources in the Inputs Menu, and run the test. The added expense and trouble of external charge-amps and power supplies are a thing of the past. Virtual Instrument Screen Your computer screen is turned into a virtual instrument, with plotting, LED style readouts, control buttons and status indicators all arranged in an easyto-read format. All of the setup details are hidden in drop-down menus. Common functions can be performed by either mouse, keyboard, or hardware or software remote control. In addition, the monitor status bar provides the user a view of all test parameters for the current test.

8-Channel Input Standard The sensitivity of each of the eight input channels can be defined and a label may also be assigned along with a transducer serial number for future reference. The controller can be set to any combination of control or measurement channels. Menu Setup All of the details of the test setup are managed in familiar Windows dropdown menus; users will appreciate the familiar menu arrangement and quickly master entering test parameters. Profile Setup The Modify Profile screen defines the random PSD reference spectrum or sine D,V,A test schedule. Breakpoints can be defined in English or metric units and freely converted back and forth; up to 32 breakpoints can be defined for each test.. Free Software Upgrades The software is typically updated twice/year and the upgrades are posted on the web-site for downloading- always for free. Combined with the extended warranty and no service contracts, the economical purchase price is the total cost except for a readily available computer. Demo Software Demo software is available on disk or on-line for training and product evaluation purposes; the working software can also be used in a demo mode for training purposes. Use With Any Computer Why be locked into an obsolete computer? Use the DVC-8 with any available PC and upgrade as technology moves foreword. The DVC-8 requires only one PCI card slot to interface with the control module. The software automatically resizes for use with any monitor. No ISA slots required! Ease of Installation and Use Operation of the DVC-8 controller can be mastered in minutes, without enduring the lengthy training period competitors require. The makes the DVC-8 well suited for production stress screening and small shops, where dedicated test labs and trained staff may not be present. Remote Control Common Start/Stop/Abort type functions can be controlled remotely by either logic signals or switch closures, or be software calls to the DLL, enabling the DVC-8 to be integrated into test chambers and automated test systems. Software Calibration There are no trimpots or adjustments; calibration is done in software. The calibration procedure is included in the help file. Manual Mode All three software packages can be operated in a manual mode, simulating sine and shaped random signal generators, and waveform generator in shock.

Software Package Specifications: Sine Vibration Control Software Package DSC Frequency : Range: 1 Hz to 10 KHz. Stability: +/= 100 ppm/ C, crystal controlled. Distortion: <0.50% thd, 0.25% typical. Limits: sweeps between programmed lower and upper limits. Sweep Mode: Linear, Logarithmic or MIL-167 Incremental. Sweep Rate: Entered in Oct/min, Hz/sec, Hz/step 0.1-99.9 Oct/Min or 0.1-99.9 Hz/sec. Control Method: Average, Extremal, or Manual. Control Channel: Any combination of channels may be used for control and/or measurement. Dynamic Range: Greater than 70 db. Reference Profile: Defined with any combination of Displacement, Velocity or Acceleration. Up to 32 breakpoints may be defined. Automatic crossover frequency calculation from Displacement, Velocity or Acceleration. Two dwells points can be programmed for a specified time at any desired frequency point. Test Article Protection: Automatic loop check for safety for open loop, low gain, over/under test and system limits. Displays: Interactive Windows displays, allowing for real time user display changes. Display types Include: Target Profile. Response of selected channel Alarm and abort limits. Test Documentation: Display Monitor Any of the above screens may be saved or printed out. The monitor bar displays the setup conditions, test status, and reference and current displacement, velocity and acceleration values. Random Vibration Control Software Package DRC Frequency Ranges: Spectral Resolution: Control Method: Control Channel: Dynamic Range: Loop Time: Equalization: Reference PSD: (Profile) Random Signal: Sigma Clipping: Pre-test: Filtering Analysis Windowing Test Article Protection Displays: Test Documentation Display Monitor 1.25-500, 2.5-1000, 5-2000, 10-4000 Hz. 200, 400, 800 or 1600 lines. Average, Extremal, or Manual. Any combination of channels may be used for control and/or measurement. Greater than 60 db. 500 msec @ 2,000 Hz and 400 lines of resolution. ±1 db typical Defined by G 2 /Hz or m/s 2 /Hz with up to 100 breakpoints. Separate alarm/abort limits defined for each segment or overall setting. True random signal of gaussian amplitude distribution. User selectable from 1.0 to 4.0 sigma. Settable from 1 to 20 Db below full test level. 8-pole anti-alias filters on all signal inputs and drive output. Rectangular, Hamming, Hanning or Blackman selectable. Automatic loop check for safety for open loop, low gain, spectral or over/under test and system limits. Interactive Windows displays, allowing for real time user display changes. Display types Include: Reference spectrum Response spectrum for each channel Drive output Alarm/abort limits Captured waveforms for each input channel Any of the above screens may be saved or printed out. The monitor bar displays the setup conditions, test status, and reference and current displacement, velocity and acceleration values.

Classical Shock Control Software Waveform: Pulse Width: Analyzing Time: Frequency Range: Equalization : Tolerance: Pulse Polarity: Pulse Modes: SRS Analysis: Pre/Post- Compensation: Parameters: Test Article Protection: Displays: Test Documentation: Display Monitor Common Features CSC Pre-defined waveforms: half sine, initial/terminal peak Saw tooth, triangular, quarter-sine, parabolic cusp, sine-burst or custom user-generated waveform. 0.1 to 100 msec for fixed waveform. 100 msec to 1 sec. 0.1 Hz to 10 KHz Low-level equalization on one channel (Remaining channels available for measurement). Alarm and abort, MIL 810, IEC + other standard limits. ±, Selectable. Single or repetitive pulses, with settable pulse count and rep rate. 1/1, 1/3, 1/6, 1/12 and 1/24 octave. Automatic optimization of pre- and post- shock pulses. Acceleration, velocity & displacement in English or metric units. Automatic loop check for safety for open loop, low gain, over/under test and system limits. Interactive Windows displays, allowing for real time user display changes. Display types Include: Time Trace: Test Profile Accelerometer Response Drive Waveform Alarm/Abort limits Shock Response Spectrum Any of the above screens may be saved or printed out. The monitor bar displays the setup conditions, test status, and reference and current displacement, velocity and acceleration values. Input Channels: 8 channel configuration standard Input Sensitivity: Settable from 5 to 1000 mv/g, 20 Vp-p maximum input each channel (BNC connectors). Current Sources: Four, 4 MA each input, 18 VDC compliance, software selectable. Output Channels: 1 Drive channel, 1 COLA output. Output Level: 16 Vp-p or 5 Vrms maximum (BNC connector). Units English or Metric with auto-conversion of all setup parameters. Operating System: Microsoft Windows NT/2000/Xp/Vista compatible. Display: Re-sizes automatically for all common screen resolutions. Hard Copy Any printer supported by the Windows Operating System; color or black & white printouts. Remote Control: Remote Start/Stop/Abort with external logic signal, switch closure, or by DLL calls for software control. Export of Data Industry standard EXCEL file format or clipboard. Computer Requirements: Pentium 1Gb or better; uses 20 mb memory and 1 PCI card slot. Size 2.5 H x 7.25 W x 10 D

DVC-8 PLUS: The DVC-8 is being introduced in the basic format with all of the above features; during 2009 the following list of features are being added, and the product offering all those features is called the DVC-8 Plus. Features being added are: Up to 1600 Lines of resolution in Random: User choice of 200 or 400 lines for faster loop times or 800 or 1600 lines for highest resolution. Sine Resonance Search & Dwell: In Sine control mode, the controller will sweep over a specified band and locate a resonance and dwell at that resonance point. Sine-on-Random : Sine-On-Random, or S-O-R mode is the process of adding a group of sine waves to a random noise background; this is done to more faithfully replicate situations like helicopters, where there is a lot of noise, but also a dominant vibration from the rotor and it s harmonics. Up to ten sine tones can be entered into the setup table along with their control and abort parameters; these tones will be added to the random background when the S-O-R function is enabled. Random-on-Random: : Random-On-Random, or R-O-R mode is the process of adding a group of narrow-band random peaks to a random noise background; this is done to more faithfully replicate situations like helicopters, where there is a lot of noise, but also a dominant vibration from the rotor and it s harmonics. Up to ten narrow-band random tones can be entered into the setup table along with their control and abort parameters; these tones will be added to the random background when the R-O-R function is enabled. Field Data Recording: Field data replication is the process of recording real-time acceleration data from a test situation; the DVC-8 can do that, taking advantage of the built-in signal conditioning and current sources. Recording time is limited only by computer memory. Field Data Replication: Field data replication is the process of recording real-time data from a test situation and then playing back the recorded data through the shaker system with the controller making the necessary corrections so as to faithfully reproduce the desired test results. To accomplish this task the controller needs a source file to take data from; field acceleration data can either be recorded using the DVC-8 or previously saved files can be imported. Common data formats can be converted and short data can be looped indefinitely. The data is played back through the DVC-8, applying necessary corrections to duplicate real-world situations a previously saved equalization curve is applied to the data stream to for correction for the anomalies of the complete shaker system so that the test result faithfully duplicated the recorded environment.. DYNAMIC SOLUTIONS, LLC P.O. BOX 7963 NORTHRIDGE, CA 91327 P: 818.831.0832 F: 818.831.0842 WWW.DYNSOLUSA.COM SALES@DYNSOLUSA.COM Rev. 5/19/09