Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. DC- P becomes Cat. No. DC-PZ. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. - - - - Z Z Z Z Z Z Z Z Z Z Z Z Z Electrically Held s Bulletin -PK Master Contact Cartridges AC-Operated s Rail Mount Type General Purpose Cat. No. Cat. No. -PK -PK -Pole -PK -PK -PK -PK -Pole -PK -PK -PK -PK -Pole -PK -PK AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.- PK becomes Cat. No.-PKA for V Hz. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Hz - - - - - - - - B B A B B B B B B B B A A A B A A A A A A A Optimized for V, Hz. Operates satisfactorily at V, Hz. Optimized for V, Hz. Operates satisfactorily at V, Hz. Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. s can be supplied with N.C. contacts. Overlap contacts: To order a relay containing one pair: Use Cat. No. -PZ. To order a relay containing two pairs: Use Cat. No. -PZ. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A, DC Ratings: P. Location of contacts in -pole relays. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. See Accessories on page - for NEMA Type, Type /X, and Type / enclosures available for field installation. - Publication A-CAA-EN-P
Bulletin -P NEMA Heavy-Duty Industrial Controls Overview/Product Selection -P Bulletin -P and -PK Direct Drive Convertible Contact Cartridge s NEMA and IEC ratings V maximum AC/DC Accessories for field installation: Adder Decks, time delay, latching, surge suppressors, mounting strip Contact Ratings: ( A) -CP, ( A) -CPM, ( A) -CPH, (Low Power) -CPR For machine tool and other heavy-duty applications Can accommodate ring tongue terminals Integral DIN Rail adapter on AC relays Finger-safe protection standard Table of Contents Accessories....... - Specifications..... - Approximate Dimensions....... - Standards UL CSA C., No. EN/IEC -, -- Certifications culus Listed (File No. E, Guide NKCR/NKCR) ABS Certified Description The Bulletin -P family of relays has four types of contact cartridges to meet your specific switching requirements. Different cartridges can be combined into one relay to yield a custom-tailored application solution. Time delay, latching attachments, overlapping, and logic reed contacts are available. Bulletin -P relays use standard ( A) contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent contact reliability and low-contact bounce, while the double-break contact design reduces the possibility of contacts welding and enhances the relay s ability to break DC circuits. These relays are supplied with a max. of contacts (max. N.C.). Bulletin -PK master control relays contain ( A) master contact cartridges with large single-contact pads on each side of the spanner for twice the current rating to control heavy loads and for master control of a system. The Bulletin -PK relay also has the same doublebreak design as the -P relay. These relays are supplied with a max. of contacts (max. N.C.). Time delay and latching attachments are available. Bulletin -P and -PK relays combine the advantages of convertible contacts with Direct Drive, a construction designed to maintain nonoverlap operation between N.O. and N.C. contacts (within published ratings). Bulletin -PH relays contain ( A) tandem contact cartridges. A jumper kit (Cat No. -CPH) allows two ( A) master contact cartrridges to be connected in parallel. A maximum of six poles are supplied, up to four of which can be normally closed. Time delay and latch attachments are available. Electrically Held s Bulletin -P Standard Contact Cartridge AC-Operated s Rail Mount Cat. No. -Pole -P -P -Pole -P -P -Pole -P -P AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. -P becomes Cat. No. -PA. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Hz - - - - - - - - B B A B B B B B B B B A A A B A A A A A A A Optimized for V, Hz. Operates satisfactorily at V, Hz. Optimized for V, Hz. Operates satisfactorily at V, Hz. Location of contacts in -pole relays. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. s can be supplied with N.C. contacts. Overlap contacts: To order a relay containing one pair: Use Cat. No. -PZ. To order a relay containing two pairs: Use Cat. No. -PZ. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A, DC Ratings: P. See Accessories on page - for NEMA Type, Type /X, and Type / enclosures available for field installation. Publication A-CAA-EN-P -
Bulletin -P Heavy-Duty Industrial s Specifications Contact Rating Continuous Ratings Make/Break Type -P, PL, PT -PK, PKL, PKT -PH Additional Contact Ratings for AC single-phase loads A @ V AC A @ V DC Electrical A @ V AC A @ V DC A @ V AC A @ V DC AC NEMA A x NEMA A x NEMA A DC NEMA P x NEMA P x NEMA P Hp @ V AC - N.O. Hp @ V AC - N.O./N.C. Hp @ V AC - N.O./N.C. A Resistive Heating to V AC A Tungsten Lighting Load to V AC Hp @ V AC - N.O. Hp @ V AC - N.O./N.C. Hp @ V AC - N.O./N.C. A General Use At. PF to V AC A Tungsten Lighting Load to V AC DC Current Ratings Make/Break Cartridge Cat. No. -CP Cartridge Cat. No. -CPM Cartridge Cat. No. -CPH Volts DC in Series W W W W W W DC Switching A. A. A. A. A. A A A. A. A. A. A A A. A. A. A. A A A A A. A. A A A A A. A. A A A A A. A. A A A. A. A A A A. A. A A A A. A. A A A. A. A A A A. A. A A A A. A. A AC % % % Coil Voltage DC % % % Range Battery Charging % % % Hz Hz Hz Hz Hz Hz Coil A Inrush VA VA VA VA VA VA Consumption C Sealed.VA VA. VA VA.VA VA P-PH-PK D Inrush.VA.VA.VA C Sealed.VA.VA.VA PLL - PKLL Inrush VA.VA VA.VA VA.VA AC Latch Unit Sealed.VA.VA.VA.VA.VA.VA PLL - PKLL Unlatch VA VA DC Latch Unit Intermittent W W Reset Time PT PKT ms ms Minimum Pulse PLL PKLL ms ms Mechanical Operating Time Mechanical Life Pickup Dropout DC ms DC ms Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) DC ms DC ms million operations Construction Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) DC ms DC ms Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) Contact Material Nickel Silver Silver Cadmium Oxide Silver Cadmium Oxide Mounting Environmental Temperature Operating + C ( F) + C ( F) + C ( F) Storage + C ( F) + C ( F) + C ( F) Certifications CSA Certified, CSA File #LR, UL Listed, UL File #E, Guide NKCR, CE Certified, ABS Standards UL, CSA C. No., EN/IEC -, -- Wire Terminations Wire size per UL/CSA # AWG () # AWG Tightening Torque lb in (.. N m) Temperature inside the panel. Average value for all coils within range. For values on a specific coil voltage, contact your local Rockwell Automation sales office or Allen-Bradley distributor. Publication A-CAA-EN-P -
Bulletin -P Heavy-Duty Industrial s Specifications Operating Coils Bulletin Bulletin -P-PH-PK s Bulletin -PLL-PKLL Mechanical Latch Attachments Coil Volts Bulletin -P, -PK -pole, Bulletin -PH -pole AC Bulletin -PLL PKLL AC Mechanical Latch Attachment Bulletin -P-PK -pole, Bulletin -PH -pole DC Hz Hz Hz Hz PA PA PL PL PD PD PA PA PL PL PD PA PL PD ( ) PA PL PA PL Bulletin -P Operating Coil PD PA PL PD PA PL PA PA PL PA PA PL PL PD PD PA PA PL PA PL PA PL Bulletin -PL Unlatch Coil and Magnet Assembly PA PL PA PL PD PA PL PD Coils for AC relays cannot be used in DC relays and vice versa. This coil is optimized for V, Hz applications and will operate satisfactorily at V, Hz. This coil is optimized for V, Hz applications and will operate satisfactorily at V, Hz. This coil is designed and marked for use at V DC. - Publication A-CAA-EN-P
Bulletin -P Heavy-Duty Industrial s Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Bulletin -P, -PH and -PK s. (-/). (-/) /. (/) - and -pole Bulletin -P, -PK -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb) AC. (-/). (/) - and -pole Bulletin -P or -PK or -pole Bulletin -PH with Pneumatic Time Delay Attachment Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/). (/) - and -pole Bulletin -P, or -PK -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/). (/) - and -pole Bulletin -P or -PK or -pole Bulletin -PH with Mechanical Latch Attachment Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb) Cat. No.. (/) - and -pole Bulletin -P, DIN Rail Adapter or -PK -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/) # Screws (Captive) Rail for Bulletin -P, -PH, -PK, -N, -NM, -R, -RM, -RT, -RTA s Secure the mounting strip with two screws at each end relay position. Use a minimum of one screw at the rd, th, th, etc., relay positions. Alternate between upper and lower horizontal slots. AC. (-/) DC (-/) -PS Timer Cat. No. -N, Type Enclosure for Bulletin -P, -PH, -PK, -RTC s Approximate Shipping Weight:. kg (. lb) Bulletin -PS Timer Mounted on a -pole Bulletin Bulletin -P or -PK or -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb) without -PS, edc. kg (. lb) without -PS. (.). (/) (-/). (/). (/). (.). (.). (.) (-/). (.). (.). (.). (.) Cat. No. -DR DIN Mounting Rail Series B Cat. No. -DR DIN Mounting Rail Series B Has No Mounting Holes Publication A-CAA-EN-P DIN Rail Adapter -