Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Similar documents
Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-HL 2-Pole Terminal Block Relay

ALLEN BRADLEY RELAY Bulletin 700-HF

Allen-Bradley 700-K40E-DJ

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

Allen-Bradley Drives

Bulletin 700-HA Tube Base Relay

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

Cat. No. (Spring Clamp. Input Voltage

CS7 Industrial Control Relays

Bulletin 817 Thermistor Protection Relay

CS8 Industrial Control Relays

CS7 Industrial Control Relays

Allen-Bradley Bulletin 100 Contactors

2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Control, Timing + Ice Cube Relays

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

3.7. Control Relays and Timers.

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description

Allen-Bradley 1492-RCDA4A40

78 Series Electromechanical Relay Selection Guide

Crane Control Contactors and Relays

PRODUCT SPECIFICATION. PC Board Relays. Series.

Ultra Slim Relays 24

Digital ac/dc (24V) Input Module

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Relay and Timer Specifications

800 T A 1 A. f (cont'd) d (cont'd) f (cont'd) Momentary Contact Push Button Devices, Non-Illuminated. Rockwell Automation Publication 800-TD009A-EN-P

Installation Instructions

WEG Contactors - CWM and CWME Series

TeSys IEC Contactors and Overload Relays

Motor protection relays

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

General Purpose Relays R2N/R4N Miniature Power Plug-in Relays

DeltaV Bulk Power Supplies

Micro Contactor MA Series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Mini Contactors & Overloads

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

K-Line Mini - Contactors, Overload Relays and Accessories

1492-SP Supplementary Protectors

Installation Instructions

02/11/2015

Digital ac/dc (24V) Input Module

Bulletin 1489 Circuit Breakers. Selection Guide

Control & Timing Relays

194E FA 32 E P11 P11 6

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Relays, Timers, & Temperature Controllers Table of Contents

TeSys contactors From 115 to 2750 A

MSR178DP. Description. Features. Specifications

Relays & Sockets RR Series Power Relays. Part Number Selection

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

Square D General Purpose Relays

Pico Accessories. Memory Modules. This section provides information on various accessories.

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

C 2 5 D N A A A

Large Frame IEC Contactors

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Not recommended for use in applications where there is high probability for exposure to liquid (e.g., cutting fluid) on the sensing surface area.

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

Complete UL/CSA Disconnect Switch Kits

Bulletin 871D Cylinder Position Inductive Style

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Electronic timer CT-ERS.21

Miniature Circuit Breakers and Supplementary Protectors. Contents

IEC Contactor Specifications

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

Magnetic Style Safety Interlock Switches

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM4JA01F current measurement relay RM4-J - range ma V AC

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Model Number Structure

Advantages of a Full Featured 700 Series Relay

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

CompactLogix Power Supplies Specifications

Model Number Structure

RUC industrial relays of small dimensions

RM4TA32 three-phase network control relay RM4-T - range V

R15 industrial relays of small dimensions

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-ARS.11

Contact protection relay

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

General-Purpose Photoelectric Sensor

[.050 (1.27mm) Density. D-Microminiature]

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Transcription:

Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. DC- P becomes Cat. No. DC-PZ. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. - - - - Z Z Z Z Z Z Z Z Z Z Z Z Z Electrically Held s Bulletin -PK Master Contact Cartridges AC-Operated s Rail Mount Type General Purpose Cat. No. Cat. No. -PK -PK -Pole -PK -PK -PK -PK -Pole -PK -PK -PK -PK -Pole -PK -PK AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.- PK becomes Cat. No.-PKA for V Hz. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Hz - - - - - - - - B B A B B B B B B B B A A A B A A A A A A A Optimized for V, Hz. Operates satisfactorily at V, Hz. Optimized for V, Hz. Operates satisfactorily at V, Hz. Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. s can be supplied with N.C. contacts. Overlap contacts: To order a relay containing one pair: Use Cat. No. -PZ. To order a relay containing two pairs: Use Cat. No. -PZ. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A, DC Ratings: P. Location of contacts in -pole relays. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. See Accessories on page - for NEMA Type, Type /X, and Type / enclosures available for field installation. - Publication A-CAA-EN-P

Bulletin -P NEMA Heavy-Duty Industrial Controls Overview/Product Selection -P Bulletin -P and -PK Direct Drive Convertible Contact Cartridge s NEMA and IEC ratings V maximum AC/DC Accessories for field installation: Adder Decks, time delay, latching, surge suppressors, mounting strip Contact Ratings: ( A) -CP, ( A) -CPM, ( A) -CPH, (Low Power) -CPR For machine tool and other heavy-duty applications Can accommodate ring tongue terminals Integral DIN Rail adapter on AC relays Finger-safe protection standard Table of Contents Accessories....... - Specifications..... - Approximate Dimensions....... - Standards UL CSA C., No. EN/IEC -, -- Certifications culus Listed (File No. E, Guide NKCR/NKCR) ABS Certified Description The Bulletin -P family of relays has four types of contact cartridges to meet your specific switching requirements. Different cartridges can be combined into one relay to yield a custom-tailored application solution. Time delay, latching attachments, overlapping, and logic reed contacts are available. Bulletin -P relays use standard ( A) contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent contact reliability and low-contact bounce, while the double-break contact design reduces the possibility of contacts welding and enhances the relay s ability to break DC circuits. These relays are supplied with a max. of contacts (max. N.C.). Bulletin -PK master control relays contain ( A) master contact cartridges with large single-contact pads on each side of the spanner for twice the current rating to control heavy loads and for master control of a system. The Bulletin -PK relay also has the same doublebreak design as the -P relay. These relays are supplied with a max. of contacts (max. N.C.). Time delay and latching attachments are available. Bulletin -P and -PK relays combine the advantages of convertible contacts with Direct Drive, a construction designed to maintain nonoverlap operation between N.O. and N.C. contacts (within published ratings). Bulletin -PH relays contain ( A) tandem contact cartridges. A jumper kit (Cat No. -CPH) allows two ( A) master contact cartrridges to be connected in parallel. A maximum of six poles are supplied, up to four of which can be normally closed. Time delay and latch attachments are available. Electrically Held s Bulletin -P Standard Contact Cartridge AC-Operated s Rail Mount Cat. No. -Pole -P -P -Pole -P -P -Pole -P -P AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. -P becomes Cat. No. -PA. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Hz - - - - - - - - B B A B B B B B B B B A A A B A A A A A A A Optimized for V, Hz. Operates satisfactorily at V, Hz. Optimized for V, Hz. Operates satisfactorily at V, Hz. Location of contacts in -pole relays. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. Location of contacts in -pole relays: -pole relay plus the two contacts indicated. Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. s can be supplied with N.C. contacts. Overlap contacts: To order a relay containing one pair: Use Cat. No. -PZ. To order a relay containing two pairs: Use Cat. No. -PZ. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A, DC Ratings: P. See Accessories on page - for NEMA Type, Type /X, and Type / enclosures available for field installation. Publication A-CAA-EN-P -

Bulletin -P Heavy-Duty Industrial s Specifications Contact Rating Continuous Ratings Make/Break Type -P, PL, PT -PK, PKL, PKT -PH Additional Contact Ratings for AC single-phase loads A @ V AC A @ V DC Electrical A @ V AC A @ V DC A @ V AC A @ V DC AC NEMA A x NEMA A x NEMA A DC NEMA P x NEMA P x NEMA P Hp @ V AC - N.O. Hp @ V AC - N.O./N.C. Hp @ V AC - N.O./N.C. A Resistive Heating to V AC A Tungsten Lighting Load to V AC Hp @ V AC - N.O. Hp @ V AC - N.O./N.C. Hp @ V AC - N.O./N.C. A General Use At. PF to V AC A Tungsten Lighting Load to V AC DC Current Ratings Make/Break Cartridge Cat. No. -CP Cartridge Cat. No. -CPM Cartridge Cat. No. -CPH Volts DC in Series W W W W W W DC Switching A. A. A. A. A. A A A. A. A. A. A A A. A. A. A. A A A A A. A. A A A A A. A. A A A A A. A. A A A. A. A A A A. A. A A A A. A. A A A. A. A A A A. A. A A A A. A. A AC % % % Coil Voltage DC % % % Range Battery Charging % % % Hz Hz Hz Hz Hz Hz Coil A Inrush VA VA VA VA VA VA Consumption C Sealed.VA VA. VA VA.VA VA P-PH-PK D Inrush.VA.VA.VA C Sealed.VA.VA.VA PLL - PKLL Inrush VA.VA VA.VA VA.VA AC Latch Unit Sealed.VA.VA.VA.VA.VA.VA PLL - PKLL Unlatch VA VA DC Latch Unit Intermittent W W Reset Time PT PKT ms ms Minimum Pulse PLL PKLL ms ms Mechanical Operating Time Mechanical Life Pickup Dropout DC ms DC ms Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) DC ms DC ms million operations Construction Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) DC ms DC ms Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) Contact Material Nickel Silver Silver Cadmium Oxide Silver Cadmium Oxide Mounting Environmental Temperature Operating + C ( F) + C ( F) + C ( F) Storage + C ( F) + C ( F) + C ( F) Certifications CSA Certified, CSA File #LR, UL Listed, UL File #E, Guide NKCR, CE Certified, ABS Standards UL, CSA C. No., EN/IEC -, -- Wire Terminations Wire size per UL/CSA # AWG () # AWG Tightening Torque lb in (.. N m) Temperature inside the panel. Average value for all coils within range. For values on a specific coil voltage, contact your local Rockwell Automation sales office or Allen-Bradley distributor. Publication A-CAA-EN-P -

Bulletin -P Heavy-Duty Industrial s Specifications Operating Coils Bulletin Bulletin -P-PH-PK s Bulletin -PLL-PKLL Mechanical Latch Attachments Coil Volts Bulletin -P, -PK -pole, Bulletin -PH -pole AC Bulletin -PLL PKLL AC Mechanical Latch Attachment Bulletin -P-PK -pole, Bulletin -PH -pole DC Hz Hz Hz Hz PA PA PL PL PD PD PA PA PL PL PD PA PL PD ( ) PA PL PA PL Bulletin -P Operating Coil PD PA PL PD PA PL PA PA PL PA PA PL PL PD PD PA PA PL PA PL PA PL Bulletin -PL Unlatch Coil and Magnet Assembly PA PL PA PL PD PA PL PD Coils for AC relays cannot be used in DC relays and vice versa. This coil is optimized for V, Hz applications and will operate satisfactorily at V, Hz. This coil is optimized for V, Hz applications and will operate satisfactorily at V, Hz. This coil is designed and marked for use at V DC. - Publication A-CAA-EN-P

Bulletin -P Heavy-Duty Industrial s Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Bulletin -P, -PH and -PK s. (-/). (-/) /. (/) - and -pole Bulletin -P, -PK -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb) AC. (-/). (/) - and -pole Bulletin -P or -PK or -pole Bulletin -PH with Pneumatic Time Delay Attachment Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/). (/) - and -pole Bulletin -P, or -PK -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/). (/) - and -pole Bulletin -P or -PK or -pole Bulletin -PH with Mechanical Latch Attachment Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb) Cat. No.. (/) - and -pole Bulletin -P, DIN Rail Adapter or -PK -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/) # Screws (Captive) Rail for Bulletin -P, -PH, -PK, -N, -NM, -R, -RM, -RT, -RTA s Secure the mounting strip with two screws at each end relay position. Use a minimum of one screw at the rd, th, th, etc., relay positions. Alternate between upper and lower horizontal slots. AC. (-/) DC (-/) -PS Timer Cat. No. -N, Type Enclosure for Bulletin -P, -PH, -PK, -RTC s Approximate Shipping Weight:. kg (. lb) Bulletin -PS Timer Mounted on a -pole Bulletin Bulletin -P or -PK or -pole Bulletin -PH Approximate Shipping Weight: AC. kg (. lb) without -PS, edc. kg (. lb) without -PS. (.). (/) (-/). (/). (/). (.). (.). (.) (-/). (.). (.). (.). (.) Cat. No. -DR DIN Mounting Rail Series B Cat. No. -DR DIN Mounting Rail Series B Has No Mounting Holes Publication A-CAA-EN-P DIN Rail Adapter -