Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet

Similar documents
Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack

Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack

SER8300 Room Controller

SmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with

SE8300 Room Controller

VT8300 Room Controller

Room Controllers. SC3000 Relay Pack

Room Controller. SE8300 Low Voltage Fan Coil Controller and Zone Controller

VZ7000 Series. BACnet Commercial Zoning System

The Bard BrightStat Room Controllers

SEZ7000 Series. Wireless Commercial Zoning System

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

SE7600E Series Application Guide

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

VTR8300 User Interface Guide VTR8300 Room Controller Series

Application Guide. Fan Coil (FCU) Application Guide. VTR8000 Series Room Controllers. Control Performance Energy savings Better building management

TC-9102 Terminal Controller

SER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide

VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications

SER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide

SE7600E Series Application Guide

VTR8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications

SE8300 User Interface Guide SE8300 Series Room Controller

Modbus Integration Integration for Modbus Functionality for VTR8300 Series

VT8600 Series Installation Guide. Rooftop Unit, Heat Pump and Indoor Air Quality Controller

CENTRALISED CONTROL SYSTEMS. Operation with various functions from a CZ-RWSD2 CZ-RWST3N CZ-RWSK2 CZ-64ESMC3

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Smart Equipment Controls (SEC)

Firmware Upgrade Release Notes. Release Notes for VT8000 Series Room Controllers

Features BACnet/IP over Wi-Fi, BACnet MS/TP, Delta LINKnet communication. EnOcean wireless for zone-level control, including sensors and outputs

Allure EC-Smart-Comfort Series

Field selectable application type and room module series, via dip-switches on controller

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Fan coil (FCU) application guide

VT8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

Viconics VT7682S Wireless Central Manager Application Guide

CONTENTS. Installation Guide. PIR Ready VT7200 Series 24 VAC Low Voltage Zoning Terminal Equipment Controller

Allure EC-Smart-Comfort Series

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

SmartX Living Space Sensors

System Controls Suggested Specification

SmartStruxure Lite solution Get Control. Get Efficient. Get Value.

Submittal Data Sheet intelligent Touch Manager DCM601A71

SE8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications

Pro. LCN1840/05 Wireless gateway. Specification sheet. Connected lighting. Find out more about Interact

VTR8300 / VT8300 Series BACnet Integration Terminal Equipment Controller

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

Specification Sheet For electronically commutated motors

BACnet Integration Manual ITG-VWG-50-BAC-E01.doc ( R1 Issue Date: January 10 th, 2012)

Multiple Channel Approach. Marc Bertolin Regional Account Manager - Products

SE8000 Series BACnet Integration

Siemens BACnet Programmable TEC Unit Conditioner Controller

Overview. Integrated fail-safe mode in case of communication or power failure to comply with most regulation requirements

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Room controller STRA-17

SER8300 User Interface Guide SER8300 Series Room Controller

TM-2100 Series Room Command Module

Medium User Interface (MUI) Version 3

FXVMA Variable Air Volume (VAV) Box Controller

TM-2100 Series Room Command Module

clarity 3 Programmable Controller

Room unit with PPS2 interface

AIR HANDLING UNIT CONTROLS

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal.

BACnet. b3810 Series Local Controllers

FX Input/Output (I/O) Modules XM07 and XM14

VTR8300 / VT8300 Series BACnet Integration Terminal Equipment Controller

March 13 th, 2012 / R2

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

Modular Room Control (MRC) Series Expansion Board

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Pre-programmed room controller with display and communication

Siemens BACnet Programmable TEC Constant Volume

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

HARDWARE GUIDE. VAV Zone Controller C1000 Series. Specifications and Operational Guide

Hotel Room Controller

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Andover ContinuumTM. b3850 Series Terminal Controllers

SmartStruxure Lite Solution

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

THERMOSTATS & CONTROLLERS

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

Product Comparison Guide. SmartStruxure Lite solution and Wireless Devices for SmartStruxure Solution

5AMP Power Pack. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALPP 5ACC or ALPP 5A Part #: or

Siemens BACnet Programmable TEC Unit Vent Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

SYSTIUM MODEL 526EX UATX

SE8000 Series BACnet Integration

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

TC-8900 Controller Units with PM-8900 Power Modules

Transcription:

Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet Application specific room controller with customizable screen colors. The VTR8300 is a line-voltage fan coil terminal equipment controller with relay pack. Suitable for both commercial and high end hospitality markets.

2 The perfect balance between simplicity and sophistication. An elegantly simple casing combines with configurable screen colors to match decor. Display your own logo and custom messages on screen to reinforce your brand and provide a more enjoyable occupant experience. Introduction This two component retrofit option consists of the VTR8300 room controller and the VC3000 relay pack. Together, they provide an easy solution for retrofitting fan coil unit thermostats without requiring other components such as relays, transformers, controllers, sensors, and network wiring to be upgraded. Existing line voltage wiring between the fan coil unit and room controller can be reused to further minimize overall labor and installation costs for both retrofit and new construction control projects. Additional flexibility and energy savings can be achieved with optional wireless door and window switches. AT A GLANCE Custom design Touch screen with customizable user experience 5 selectable screen colors out of the box Supports the upload of a custom standby screen Supports the display of custom messages when integrated to a BACnet system English, French, Spanish, Chinese and other languages selectable out of the box One touch changes C / F Options and accessories VC3000 relay pack to interface with line-voltage fan coil On-board PIR occupancy sensor (optional) Application specific and programmable The VTR8300 room controllers are both application-specific AND programmable. This enables the modification of pre-configured control sequences, or the creation of entirely new control sequences for HVAC, lighting and other applications. The room controllers are specifically designed to provide exceptional temperature control of multi-speed fan coil units. When compared to traditional building automation room controllers, the VTR8300 series fan coil room controllers provide unmatched return on investment. Touch screen with customizable user experience The touch screen of the VTR8300 offers a customizable user experience with selection of languages, units, buttons, and screen colors. It also supports the upload of an image or logo that becomes the default standby screen of the device. Custom messages can also be displayed on-screen using BACnet objects when the VTR8300 is integrated to a BACnet system. Optional passive infrared motion sensor All models can be equipped with a discrete optional Passive Infrared (PIR) motion sensor. With the embedded sensor, the VTR8300 uses advanced occupancy routines to generate automatic energy savings during occupied and unoccupied periods without sacrificing occupant comfort. RH sensor with dehumidification control (optional) Can be used with ZigBee Pro wireless sensors Free downloadable Uploader VT8000 tool for the upload of Lua Scripts, standby screen images, and firmware upgrades, using a USB/ Micro-USB cable Integration Multiple options for integration to Building Management Systems (BMS)

3 Product highlights Suitable for both commercial and hospitality markets and systems Customizable color digital touch screen interface with multi-language support Fully programmable control sequences using scripting Humidity sensor with on-board dehumidification strategy (model dependent) Optional occupancy sensor cover Advanced occupancy functions for commercial and lodging applications Optional wireless door and window switches available for wireless communicating models only Configurable fan sequence of operation On board configuration interface utility Configurable scheduler Change of value (COV) function for BMS integration INTEGRATION VTR8300 ZigBee Pro BACnet MS/TP ZigBee gateway device Automation Server Networking between VTR8300 ZigBee PRO wireless mesh network (P) BACnet MS/TP (B) Integration to BMS systems VTR8300 can be integrated with Building Management Systems Direct wired integration to BACnet MS/TP ZigBee Pro integration to ZigBee gateway device ZigBee gateway device integration to BACnet IP, obix, and EWS CUSTOM STANDBY SCREEN & MESSAGES > Custom standby screen > Custom BACnet MS/TP messages VC3000 For VC3000 relay pack features consult the VC3000 datasheet. Architects and designers can match their decor Five screen colors are selectable through the interface Customizable standby screens and messages > 5 configurable screen colors

4 Programming the VTR8300 with Lua The VTR8300 room controllers are programmable using the open programming language Lua. Although building management systems often use open protocols and standards, their program BACnet objects and scripting features remain proprietary and incompatible with third party devices. The VTR8300 use of an open language enables interopreability with all systems. Programming with BMS integration When integrated into a BACnet MS/TP building management system, the VTR8300 offers 10 Program BACnet objects, each able to contain 480 characters. No special software, license or tool is required. BACnet MS/TP integration into BMS 10 Program BACnet objects (Lua scripts) Each object can contain 480 characters max Programming without integration When there is no BACnet MS/TP integration, a Lua script can be uploaded directly to the VTR8300 using the Uploader VT8000 tool. Unlike the 10 PG objects used when the unit is integrated via BACnet MS/TP, there is only one script, which can contain up to 16KB. No BACnet MS/TP integration 1 Lua script of 16KB max Uploader VT8000 to upload scripts using PC software tool and a USB/Micro-USB cable HVAC applications and beyond Programming can be used to go beyond the pre-configured control sequences of the VTR8300 to create customized HVAC applications. It can also be used to comply with specific project requirements and manage other applications, such as lighting and other equipment. Using Lua scripts enables you to take advantage of the extra inputs and outputs of the VTR8300 to manage other devices, such as sensors and relays. Uploader VT8000 Lua scripts, standby screen images and firmware upgrades can be loaded to the VTR8300 using the Uploader VT8000 tool and a USB/Micro-USB cable. > PG objects of the VTR8300 viewed through a BMS > PG objects of the VTR8300 viewed through its touchscreen display

5 Line Voltage Fan Control Units The VTR8300 is configured to manage up to 10 different VC3000 relay packs, each controlling a line voltage fan coil installation. The diagram below shows an example of a typical line voltage fan coil application and how it would be wired to the relay pack controlled by the VTR8300. TYPICAL APPLICATION 3 Speed fan Cooling coil Heating coil Return air Supply air Filter status switch Fan status switch Existing field wires VC3504E5000 Optional Wireless ZigBee Communication or Optional Wired Bacnet Communication VTR8300 FanCoil Terminal Equipment Controller Optional Wireless Accessories ZigBee Pro Optional wireless communication SED-WDS Door & Window Switch SED-CMS Ceiling Mounted Motion Sensor SED-WMS Wall Mounted Motion Sensor

VTR8300 Room Controller and VC3000 Relay Pack Specifications VTR8300 and VC3000 Dimensions Height: 12cm/4.72in Width: 8.6cm/3.39in Depth: 2.7cm/1.06in VC3000 Power Requirements 90-277 Vac universal, 50/60Hz VTR8300 Power Requirements (supplied by VC3000) 7 Vdc 2.4 watts minimum Operating Conditions 0 C - 50 C ( 32 F - 122 F ) 0% - 95% R.H. non-condensing Storage Conditions -30 C - 50 C ( -22 F - 122 F ) 0% - 95% R.H. non-condensing Temperature Sensor Local 10 K NTC type 2 thermistor Temperature Sensor Resolution ± 0.1 C ( ± 0.2 F ) Temperature Control Accuracy ± 0.5 C ( ± 0.9 F ) @ 21 C ( 70 F ) typical calibrated Humidity Sensor and Calibration Single point calibrated bulk polymer type sensor Humidity Sensor Precision Reading range from 10-90 % R.H. noncondensing 10 to 20% precision: 10% 20% to 80% precision: 5% 80% to 90% precision: 10% Humidity Sensor Stability Less than 1.0 % yearly (typical drift) Dehumidification Setpoint Range 30% - 95% R.H. Occ, Stand-By and Unocc Cooling Setpoint Range 12.0-37.5 C ( 54-100 F ) Occ, Stand-By and Unocc Heating Setpoint Range 4.5 C - 32 C ( 40 F - 90 F ) Room and Outdoor Air Temperature Display Range -40 C - 50 C ( -40 F - 122 F ) Proportional Band for Room Temperature control Cooling & Heating: Default: 1.8 C ( 3.2 F ) Binary Inputs Dry contact across terminal BI1, BI2 and UI3 to Scom Wire Gauge Power supply: 18 gauge or larger, Communications: 24 gauge or larger Fan Line Voltage Contact Electrical Ratings Brown, Blue, Red wires 1/2 HP or 13A maximum. Approximate Shipping Weight 0.34 kg (0.75 lb) Main Heat Voltage Electrical Ratings Orange wire, 10A maximum Cool Line Voltage Electrical Ratings Yellow wire, 5A maximum Output Ratings Fan: Brown, Blue, Red wires 1/2 HP or 13A at 277Vac maximum. Safety Standards All Models UL 61010-1 (3rd edition) CSC 61010-1 (3rd edition) IEC 61010-1 (3rd edition) EMC Standards All Models EMC Directive 2004/108/EC IEC 61326-1:2005 FCC 15 Subpart B ICES-003 Radio Standards (Wireless Models) R&TTE Directive 1999/5/EC IEC 61326-1:2005 EN 301 489-1 V1.9.2 EN 301 328 V1.8.1 FCC 15 Subpart C RSS 210 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFER- ENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Check with your local government for instruction on disposal of these products. 5 Dimensions 27mm (1.06 ) 120mm (4.72 ) 86mm (3.39 )

VTR8300 Room Controller and VC3000 Relay Pack 6 Ordering information VTR83 5 0 A5 5 00 B RH sensor and control -00 = No RH sensor or control -50 = RH sensor with dehumidification control PIR: -0 = No PIR -5 = PIR on board Network -B = BACnet MS/TP (ZigBee Pro communication module available separately) ZigBee Pro communication module (ordered separately) VCM8000V5000P Part numbers VTR8300 Part numbers VTR8300A5000B VTR8350A5000B VTR8300A5500B RH sensor & control x PIR motion sensor VTR8350A5500B x x VTR8300A5000BLTD x Part numbers ZigBee Wireless Communication Modules VC3000 Relays Consult their respective datasheets for the latest available part numbers and features Viconics Technologies Inc. 9245 Langelier Blvd. St.-Leonard Quebec Canada H1P 3K9 Tel: (514) 321-5660 Fax: (514) 321-4150 028-0453-02 www.viconics.com sales@viconics.com April 2015 2015 Viconics Technologies Inc. All rights reserved.