Managing VMAX. Summary of Steps. This chapter contains the following sections:

Similar documents
EMC Symmetrix VMAX and VMAX3

Cisco UCS Director EMC Symmetrix VMAX Management Guide, Release 5.3

Managing VMware Distributed Resource Scheduler

VPLEX Operations. System Requirements. This chapter contains the following sections:

Configuring Cisco UCS Server Pools and Policies

Managing VNX Block Storage

Managing VNX Block Storage

Multiple Disk VM Provisioning

Configuring Global Service Profiles

EMC ViPR Controller. Integration with VMAX and VNX Storage Systems Guide. Version REV 01

Creating Application Containers

Service Profiles. Service Profiles in UCS Manager

Configuring Cisco UCS Server Pools and Policies

VMWARE VREALIZE OPERATIONS MANAGEMENT PACK FOR. Dell EMC VMAX. User Guide

Securing Containers Using a PNSC and a Cisco VSG

Multiple Disk VM Provisioning

Managing the VM Lifecycle

Monitoring and Reporting for an ONTAP Account

Cisco UCS Director Tech Module Cisco UCS Manager (UCSM)

Managing System Administration Settings

Managing VMware vcenter Site Recovery Manager

Managing VMware Datastore Clusters

Managing Virtual Data Centers

Cisco SME Tape Configuration

Managing System Administration Settings

Cisco SME Tape Configuration

Creating Application Containers

Cisco UCS Director Tech Module EMC XtremIO

Securing Containers Using a PNSC and a Cisco VSG

Setting the Management IP Address

Cisco UCS Director Tech Module EMC VNX and VNX2

HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration

Configuring Server Boot

Server Pools. Server Pools. Creating or Editing a Server Pool

Configuring EMC Isilon

Monitoring Inventory. Inventory Management. This chapter includes the following sections:

Configuring Port Profiles

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Here is Your Customized Document

Managing NetApp Accounts

Creating Workflows. Viewing the Task Library. Creating a Workflow. This chapter contains the following sections:

Cisco UCS S3260 System Storage Management

Configuring Service Profiles

EMC VSI for VMware vsphere Web Client

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide

FlexFlash SD Card Support

Cluster Management Workflows for OnCommand System Manager

VMWARE VREALIZE OPERATIONS MANAGEMENT PACK FOR. NetApp Storage. User Guide

Cluster Management Workflows for OnCommand System Manager

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide

EMC ViPR Controller. Service Catalog Reference Guide. Version REV 02

Introduction to Dell SC Series: Part 1

EMC Solutions Enabler (SE) version 8.2 and Unisphere for VMAX version 8.2 provide array management and control.

Cluster Management Workflows for OnCommand System Manager

EMC Exam E VMAX3 Solutions and Design Specialist Exam for Technology Architects Version: 6.0 [ Total Questions: 136 ]

Chassis Profiles and Templates

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

Cisco UCS Director Tech Module IBM Storage Arrays. June 2016

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

EMC EXAM - E Symmetrix Solutions Specialist Exam for Technology Architects. Buy Full Product.

Embedded Management on PowerMax and VMAX All Flash

FlexArray Virtualization

UCS Director: Tenant Onboarding Cisco ACI & Microsoft HyperV. Dec. 2016

Service Profiles and Templates

Managing System Administration Settings

UDP Director Virtual Edition Installation and Configuration Guide (for Stealthwatch System v6.9.0)

Cisco UCS S3260 System Storage Management

Application Provisioning

UDP Director Virtual Edition

Lab Determining Data Storage Capacity

Configuring High Availability for VMware vcenter in RMS All-In-One Setup

Installing the Cisco Nexus 1000V Software Using ISO or OVA Files

EMC Simple Support Matrix

Overview of the Self-Service Portal

DELL EMC UNITY: DATA REDUCTION

Configuration of Microsoft Live Communications Server for Partitioned Intradomain Federation

10ZiG Technology. Thin Desktop Quick Start Guide

Creating Workflows. Viewing the Task Library. Creating a Workflow. This chapter contains the following sections:

WHAT S NEW WITH TIMEFINDER FOR EMC SYMMETRIX VMAX

Using a Virtual Machine for Cisco IPICS on a Cisco UCS C-Series Server

FlexArray Virtualization Implementation Guide for Third- Party Storage

Dell EMC Unity Family

Managing System Administration Settings

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

QNAP SMI-S Provider for System Center Virtual Machine Manager 2012

HP MSA 2300 Series Configuration Guide

Site Manager. Helpdesk/Ticketing

Starting the KVM Console

Active System Manager Version 7.5 User s Guide

Executing Workflows. Executing Workflows. Accessing Service Requests. This chapter contains the following sections:

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo

Quick Start Guide (SDN)

Tenant Onboarding. Tenant Onboarding Overview. Tenant Onboarding with Virtual Data Centers

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

Cisco UCS Director F5 BIG-IP Management Guide, Release 5.0

Preparing Virtual Machines for Cisco APIC-EM

Preparing Virtual Machines for Cisco APIC-EM

Executing Workflows. Executing Workflows. Accessing Service Requests. This chapter contains the following sections:

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware

Dell EMC SAN Storage with Video Management Systems

Transcription:

This chapter contains the following sections: Summary of Steps, page 1 VMAX Management, page 2 Thin Pools, page 2 Data Devices, page 3 Thin Devices, page 4 Meta Devices, page 6 Initiator Groups, page 7 Storage Groups, page 8 Port Groups, page 10 Masking Views, page 11 Summary of Steps Add the EMC VMAX account(s). After adding your account, you have a populated inventory for all reports, including drill-down reports for masking views, thin pools, initiator groups, port groups, storage groups, and devices. Manage the needed pools, groups, devices and views: a) Create the thin pools. b) Create all devices: data devices, thin devices, and meta devices. c) Create the initiator groups. d) Create the storage groups. e) Create the port groups. f) Associate FAST policies with the storage groups. g) Add devices to the storage groups. OL-30146-02 1

VMAX Management h) Create the masking views. VMAX Management In a Cisco UCS Director EMC VMAX account you manage the following pools, groups, devices, and views: Thin pools Create/delete, expand, bind/unbind, and view details Devices data devices, thin devices, and meta devices Initiator groups Create/delete, rename, add/remove initiator, replace initiator, set override flags, and view details Storage groups Create/delete, rename, add/remove device, associate/disassociate FAST policy, and view details Port groups Create/delete, rename, add/remove port, and view details Masking views Create/delete, rename, and view details Thin Pools A new thin pool requires a unique name. Click buttons on the Thin Pools tab for the following actions: Create Create a thin pool. Expand Bind Unbind Delete Expand a thin pool. Bind a thin pool. Unbind a thin pool. View detailed reports on a thin pool. Delete a thin pool. 2 OL-30146-02

Creating A Thin Pool Creating A Thin Pool An EMC VMAX thin pool is a collection of data devices that provide storage capacity for thin devices. On the Storage pane, choose the VMAX data center. Click the Thin Pools tab. In the Create Thin Pool dialog box, enter a name in the Thin Pool field. Click Submit. Data Devices A Symmetrix device is either a data device or a thin device. The Data Devices tab provides the following actions: Create Delete Create a data device. Delete a data device. View detailed reports on a data device. OL-30146-02 3

Creating a Data Device Creating a Data Device On the Storage pane, choose the VMAX system. Click the Data Devices tab. In the Create Data Device dialog box, complete the following fields: Device Count field Capacity (GB) field Emulation drop-down list Configuration field Disk Group field The data device count. The capacity, in gigabytes. Choose the Emulation type for the data device. Choose the Configuration for the data device. The disk group name. 0 Click Submit. What to Do Next You can select a device and click to see the drill-down report. Thin Devices A Symmetrix device is either a thin device or a data device. The maximum size of a VMAX thin device (TDEV) is ~240 GB. Note If you want to create a TDEV greater than this size, combine TDEVs to form a meta device. Each TDEV can be part of only one meta device. The Thin Devices tab provides the following actions: 4 OL-30146-02

Creating a Thin Device Create Delete Create a thin device. Delete a thin device. View detailed reports on a thin device. There is no Rename action for a TDEV. The device name is unique and remains the same even if the TDEV becomes a meta device, and vice versa. Creating a Thin Device On the Storage pane, choose the VMAX system. Click the Thin Devices tab. In the Create Thin Device dialog box, complete the following fields: Device Count field Capacity (GB) field Emulation drop-down list Bind to Thin Pool field Pre-allocate 100% check box The thin device count. The capacity, in gigabytes. Choose the Emulation type for the thin device. Continue to 0. Check this check box to pre-allocate 100% of storage for the thin device. 0 1 Choose either None, or choose a thin pool to bind this device to from the list. Click Submit. What to Do Next You can select a device and click to see the drill-down report. OL-30146-02 5

Meta Devices Meta Devices A meta device enables you to aggregate thin devices to increase device size. You can create a meta device with a thin device as the head, and other thin devices as members. The total meta device size is the combination of the head size, and all the member device sizes. Note There is no Delete action for a meta device. Removing the members from a meta device results in a thin device. The Meta Devices tab provides the following actions: Create Meta Create a new meta device. View detailed reports on a meta member device. Creating a Meta Device On the Storage pane, choose the VMAX system. Click the Meta Devices tab. Click Create Meta. In the Create Meta Device dialog box, complete the following fields: Select Head Thin Device field Meta Type drop-down list Select Member Device(s) field Click Select. Continue to 0. Choose the Meta Type type. Click Select. Continue to 1. 6 OL-30146-02

Initiator Groups 0 1 2 3 In the Select dialog box, choose the head thin device, and click Select. In the Select Items dialog box, click Check All, Check None, or check the boxes for individual devices. Click Select. In the Create Meta Device dialog box, click Submit. Initiator Groups A VMAX initiator group is a collection of host bus adapters (HBAs) that work together. Initiator groups that contain other initiator groups are considered cascaded initiator groups. You can add, replace, or remove host initiators for an initiator group. A new initiator group requires the following parameters: Initiator group type Initiator group name Initiator type Initiator name Consistent LUN (on/off) Click buttons on the Initiator Groups tab for the following actions: Create Rename Delete Add Initiator Replace Initiator Remove Initiator Override Flags Create an initiator group. Rename an initiator group. Delete an initiator group. Add a host initiator. Replace a host initiator. Remove a host initiator. Override flags for volume set addressing, common serial number, disable Q rest on UA, SPC2 protocol version, environment set, AS400, avoid reset broadcast, open VMS, SSCI support1, and SCS13. View detailed reports on an initator group. OL-30146-02 7

Creating an Initiator Group Creating an Initiator Group On the Storage pane, choose the VMAX system. Click the Initiator Group tab. In the Create Initiator Group dialog box, complete the following fields: Initiator Group Type drop-down list Initiator Group field Initiator Type drop-down list Initiator field Consistent LUN check box Choose the Initiator Group Type (Standard or Cascaded). Standard is the default initiator group type. If you chose Cascaded, continue to 0. The initiator group name. Choose the initiator type (iscsi or FCP). iscsi is the default initiator type. The initiator name. Check this check box if you want to use consistent LUN. Unchecked is the default. 0 For a cascaded initiator group, complete the following fields: Select Parent Initiator Group field Select Child Initiator Group field Select the parent initiator group. Select the child initiator group. 1 Click Submit. Storage Groups A VMAX storage group is a collection of Symmetrix logical volumes that are used by an application, a server, or a collection of servers. 8 OL-30146-02

Creating an Empty Storage Group Storage groups present storage to hosts and are also used for FAST policies. In Cisco UCS Director you can create VMAX storage groups that are either Empty or Cascaded. A cascaded group can be contained within a masking view to present storage resources to an entire cluster. The Storage Groups tab provides the following actions: Create Rename Delete Add Device Remove Device Associate FAST Policy Disassociate FAST Policy Create a storage group. Rename a selected storage group. Delete a storage group. Add a new device to a selected storage group. Remove a device from a storage group. Associate a FAST policy with a selected storage group. Disassociate a FAST policy from a selected storage group. View detailed reports on a storage group. Creating an Empty Storage Group On the Storage pane, choose the VMAX data center. Click the Storage Groups tab. In the Create Storage Group dialog box, complete the following fields: Storage Group Type drop-down list Storage Group field Accept the default option Empty Storage Group. The storage group name. Click Submit. OL-30146-02 9

Creating a Cascaded Storage Group What to Do Next Add devices and associate FAST policies to the storage group. Creating a Cascaded Storage Group A cascaded storage group can contain one or more child storage groups. On the Storage pane, choose the VMAX data center. Click the Storage Groups tab. In the Create Storage Group dialog box, complete the following fields: Storage Group Type drop-down list Select Parent Storage Group field Child Storage Group field Choose Cascaded Storage Group. Choose the parent storage group. Choose the child storage group. Click Submit. What to Do Next Add devices and associate FAST policies to the storage group. Port Groups A VMAX port group is a collection of front-end ports. The Port Groups tab provides the following actions: Create Rename Delete Create a new port group. Rename a port group. Delete a port group. 10 OL-30146-02

Creating a Port Group Add Port Remove Port Add a new port to a selected group. Remove a port from a group. View detailed reports on a selected port group. Creating a Port Group On the Storage pane, choose the VMAX data center. Click the Port Groups tab. In the Create Port Group dialog box, complete the following fields: Port Group field Select Port Group field The port group name. Click Select. Continue to. 0 1 In the Select Items dialog box, choose the VMAX port group. Click Select. In the Create Port Group dialog box, click Submit. Masking Views VMAX designates three types of auto-provisioning groups: storage groups, port groups, and initiator groups. These three groups work together as a masking view. The masking view ensures that the target initiators (in an initiator group) can access the target storage resources (in a storage group) by means of the target ports (in a port group). Masking views are also useful for making changes to storage presentation. Changes to groups that belong to a masking view, such as adding a device or port, are automatically reflected in the masking view. OL-30146-02 11

Creating a Masking View Click buttons on the Masking Views tab for the following actions: Create Rename Delete Create a masking view. Rename a masking view. View detailed reports on a masking view. Delete a masking view. Creating a Masking View Before You Begin You must create a storage group, initiator group, host LUN, and port group in the system. You must attach devices to the storage group. On the Storage pane, choose the VMAX data center. Click the Masking Views tab. In the Create Masking Views dialog box, complete the following fields: Masking View field Select Storage Group field Host LUN ID field Select Initiator Group field Select Port Group field The masking view name. Choose the Storage Group. The host LUN ID. Note If a LUN ID is not specified, the Host LUN ID is autogenerated. Choose the Initiator Group. Choose the Port Group. Click Submit. 12 OL-30146-02

Creating a Masking View OL-30146-02 13

Creating a Masking View 14 OL-30146-02